• Title/Summary/Keyword: Resonance method

Search Result 2,472, Processing Time 0.026 seconds

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

Development of induction heating superheater system using new heat exchanging method (새로운 열교환 방식을 이용한 유도가열 과열증기 발생장치 개발)

  • Sul, Yong-Tae;Lee, Eui-Yong;Kwon, Hyuk-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.740-746
    • /
    • 2009
  • Two step serial load induction superheater has been proposed using resonance type induction heat method in this paper. Heat method is a type of flowing the electron induction and current to special alloy heater in body from external heat coil with non-contact method. Inverter was a full bridge serial load resonance type and inductor was used as load in LC resonance design to maximize the efficiency. The developed system is a new heat exchanging method combined with electromagnetic induction heater and fluid movement, ana very accurate to control of heating the gas, liquid and evaporated mass, so on without combustion process.

Nonlinear response of a resonant viscoelastic microbeam under an electrical actuation

  • Zamanian, M.;Khadem, S.E.;Mahmoodi, S.N.
    • Structural Engineering and Mechanics
    • /
    • v.35 no.4
    • /
    • pp.387-407
    • /
    • 2010
  • In this paper, using perturbation and Galerkin method, the response of a resonant viscoelastic microbeam to an electric actuation is obtained. The microbeam is under axial load and electrical load. It is assumed that midplane is stretched, when the beam is deflected. The equation of motion is derived using the Newton's second law. The viscoelastic model is taken to be the Kelvin-Voigt model. In the first section, the static deflection is obtained using the Galerkin method. Exact linear symmetric mode shape of a straight beam and its deflection function under constant transverse load are used as admissible functions. So, an analytical expression that describes the static deflection at all points is obtained. Comparing the result with previous research show that using deflection function as admissible function decreases the computation errors and previous calculations volume. In the second section, the response of a microbeam resonator system under primary and secondary resonance excitation has been obtained by analytical multiple scale perturbation method combined with the Galerkin method. It is shown, that a small amount of viscoelastic damping has an important effect and causes to decrease the maximum amplitude of response, and to shift the resonance frequency. Also, it shown, that an increase of the DC voltage, ratio of the air gap to the microbeam thickness, tensile axial load, would increase the effect of viscoelastic damping, and an increase of the compressive axial load would decrease the effect of viscoelastic damping.

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

Evaluation of Effects on Impact Resonance Test for Determining Modulus of Asphalt Concrete (아스팔트 콘크리트 탄성계수 결정을 위한 충격공진시험 영향요소 평가)

  • Kweon, Gi-Chul;Lee, Jae-Hoan
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.89-99
    • /
    • 2007
  • The stiffness of the asphalt concrete is represented by the complex modulus $E^*$, which is very important properties in the mechanistic design of flexible pavement system. The moduli of asphalt concrete were generally determined by dynamic modulus test. However, the dynamic modulus testing method is too complex, expensive, and time consuming to be applicable on a production basis. The IR(Impact Resonance) method has been shown to be a truly simple nondestructive testing method which produces very repetitive, consistent results. The major object of this study was to estimate of the effects on IR tests for determining modulus of asphalt concrete including impact position, specimen support condition, impact steel ball size and sampling rate. The variations of IR test results with various testing conditions are within ${\pm}2.7%$.

  • PDF

A Study on Neutron Resonance Energy of Tantalum by 46-MeV Electron Linac TOF Method (46-MeV 전자선형가속기의 TOF 방법을 이용한 탄탈의 중성자 공명 에너지 분석에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.245-249
    • /
    • 2013
  • Neutron sources from photonuclear reaction with 46-MeV electron linear accelerator at Research Reactor Institute, Kyoto University used for resonance energy measurement of natural tantalum. BGO($Bi_4Ge_3O_{12}$) scintillation detectors used for measurement of the prompt gamma ray from the natural tantalum sample. The BGO spectrometer was composed geometrically as total energy absorption detector. The electric signal from the spectrometer was analyzed for TOF(Time-of-Flight) spectrum which is used identification of neutron capture resonance energy. In this study, the neutron energy region is from 1 to 200 eV, because of strong X-ray effect produced photonuclear reaction in Ta target, the measurement was performed to below 1 keV energy region. The resonance energy was compared with the evaluated values(ENDF/B-VI, Mughabghab). All of the resonances from 4.28 ~ 200 eV were seen in the present measurement except 144.3 eV resonance.

Performance and analysis of wireless power charging system from room temperature to HTS magnet via strong resonance coupling method

  • Chung, Y.D.;Lee, C.Y.;Lee, S.Y.;Lee, T.W.;Kim, J.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.41-45
    • /
    • 2016
  • The technology of supplying the electric power by wireless power transfer (WPT) is expected for the next generation power feeding system since it can supply the power to portable devices without any connectors through large air gap. As such a technology based on strongly coupled electromagnetic resonators is possible to deliver the large power and recharge them seamlessly; it has been considered as a noble option to wireless power charging system in the various power applications. Recently, various HTS wires have now been manufactured for demonstrations of transmission cables, motors, MAGLEV, and other electrical power components. However, since the HTS magnets have a lower index n value intrinsically, they are required to be charged from external power system through leads or internal power system. The portable area is limited as well as the cryogen system is bulkier. Thus, we proposed a novel design of wireless power charging system for superconducting HTS magnet (WPC4SM) based on resonance coupling method. As the novel system makes possible a wireless power charging using copper resonance coupled coils, it enables to portable charging conveniently in the superconducting applications. This paper presented the conceptual design and operating characteristics of WPC4SM using different shapes' copper resonance coil. The proposed system consists of four components; RF generator of 370 kHz, copper resonance coupling coils, impedance matching (IM) subsystem and HTS magnet including rectifier system.

Quality Characteristics of Korean Rice Cake by Freezing Methods (냉동 방법에 따른 떡의 품질특성 변화)

  • Lee, Hye-Jin;Ku, Su-Kyung;Choi, Hee-Don;Park, Jong-Dae;Sung, Jung-Min;Kim, Young-Boong;Choi, Hyun-Wook;Choi, Yun-Sang
    • Korean journal of food and cookery science
    • /
    • v.33 no.2
    • /
    • pp.148-154
    • /
    • 2017
  • Purpose: Frozen Korean traditional rice cakes (Sulgitteok and Garaetteok) were evaluated different conditions ($-20^{\circ}C$ and $-10^{\circ}C$) freezing (magnetic resonance quick freezing and air blast freezing) to study differences in quality characteristics. Methods: Experiments analyze Korean rice cakes for water content, water activity, color, textural properties, and sensory characteristics. Results: Moisture content showed high value at $-20^{\circ}C$ freezing regardless of freezing method. Water activity was higher at $-20^{\circ}C$ than $-10^{\circ}C$, and water activity higher magnetic resonance quick freezing than air blast freezing. The lightness values were higher $-20^{\circ}C$ freezing temperature compare to $-10^{\circ}C$ freezing temperature. Hardness and chewiness were the lowest $-20^{\circ}C$ magnetic resonance quick freezing. sensory evaluation both Sulgitteok and Garaetteok showed better overall acceptability at $-20^{\circ}C$ magnetic resonance quick freezing. Conclusion: Therefore, the $-20^{\circ}C$ magnetic resonance quick freezing method resulted in favorable textural properties and sensory characteristics.