• 제목/요약/키워드: Resolution recovery

검색결과 187건 처리시간 0.025초

지반투과 레이더 시스템을 위한 SRD 임펄스 발생기 및 안테나의 설계 및 제작에 관한 연구 (A Study on Design and Fabrication of SRD Impulse Generator and Antenna for Ground Penetrating Radar System)

  • 김형종;신석우;최길웅;최진주;신상열
    • 한국군사과학기술학회지
    • /
    • 제14권3호
    • /
    • pp.509-516
    • /
    • 2011
  • In this paper, a ground penetrating radar(GPR) system is implemented for landmine detection. The performance of the GPR system is associated with the characteristics of local soil and buried target. The choice of the center frequency and the bandwidth of the GPR system are the key factors in the GPR system design. To detect a small and shallow target, the higher frequencies are needed for high depth resolution. We have been designed, fabricated and tested a new impulse generator using step recovery diodes. The measured impulse response has an amplitude of 6.2V and a pulse width of 250ps. The implemented GPR system has been tested real environmental conditions and has proved its ability to detect a small buried target.

Determination of L-Carnitine in Infant Powdered Milk Samples after Derivatization

  • Park, Jung Min;Koh, Jong Ho;Kim, Jin Man
    • 한국축산식품학회지
    • /
    • 제41권4호
    • /
    • pp.731-738
    • /
    • 2021
  • Herein, a novel analytical method using a high-performance liquid chromatography-fluorescence detector (HPLC/FLD) is developed for rapidly measuring an L-carnitine ester derivative in infant powdered milk. In this study, solid-phase extraction cartridges filled with derivatized methanol and distilled water were used to effectively separate L-carnitine. Protein precipitation pretreatment was carried out to remove the protein and recover the analyte extract with a high recovery (97.16%-106.56%), following which carnitine in the formula was derivatized to its ester form. Precolumn derivation with 1-aminoanthracene (1AA) was carried out in a phosphate buffer using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) as the catalyst. Method validation was performed following the AOAC guidelines. The calibration curves were linear in the L-carnitine concentration range of 0.1-2.5 mg/L. The lower limit of quantitation and limit of detection of L-carnitine were 0.076 and 0.024 mg/L, respectively. The intra- and interday precision and recovery results were within the allowable limits. The results showed that our method helped reduce the sample preparation time. It also afforded higher resolution and better reproducibility than those obtained by traditional methods. Our method is suitable for detecting the quantity of L-carnitine in infant powdered milk containing a large amount of protein or starch.

Analysis of Hypoxia-Inducible Factor Stabilizers by a Modified QuEChERS Extraction for Antidoping Analysis

  • Kim, Si Hyun;Lim, Nu Ri;Min, Hophil;Sung, Changmin;Oh, Han Bin;Kim, Ki Hun
    • Mass Spectrometry Letters
    • /
    • 제11권4호
    • /
    • pp.118-124
    • /
    • 2020
  • An analytical method was developed for hypoxia-inducible factor (HIF) stabilizers based on QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) sample preparation and liquid chromatography-high resolution mass spectrometry analysis. HIF stabilizers potentially enhance the performance of athletes, and hence, they have been prohibited. However, the analysis of urinary HIF stabilizers is not easy owing to their unique structure and characteristics. Hence, we developed the QuEChERS preparation technique for a complementary method and optimized the pH, volume of extraction solvent, and number of extractions. We found that double extraction with 1% of formic acid in acetonitrile provided the highest recovery of HIF stabilizers. Moreover, the composition of the mobile phase was also optimized for better separation of molidustat and IOX4. The developed method was validated in terms of its precision, detection limit, matrix effect, and recovery for ISO accreditation. To the best of our knowledge, this is the first demonstration of the application of the QuEChERS method, which is suitable as a complementary analytical method, in antidoping.

Alternative Sample Preparation Techniques in Gas Chromatographic-Mass Spectrometric Analysis of Urinary Androgenic Steroids

  • Cho, Young-Dae;Choi, Man-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권9호
    • /
    • pp.1315-1322
    • /
    • 2006
  • The following study describes the gas chromatography-mass spectrometry (GC-MS) based screening and confirmation analysis of urinary androgenic steroids. Four commercially available solid-phase extraction (SPE) cartridges, Serdolit PAD-1, Sep-pak $C_{18}$, amino-propyl, and Oasis HLB, and three different extractive organic solvents, diethyl ether, methyl tert-butyl ether (MTBE), and n-pentane, were tested for sample preparation. Overall, Oasis HLB combined with MTBE extraction provided the highest recoveries in 39 of 46 total androgenic steroids examined and it showed a good extraction yield (>82.1%) for polar steroids, such as metabolites of fluoxymesterone, oxandrolone, and stanozolol, which gave a poor recovery in both n-pentane (9.2-64.3%) and diethyl ether (22.2-73.6%) extractions. All SPE sorbents tested showed potential, because they were efficient in extraction for most or selective steroids. When applied to positive urine samples based on the results obtained, the present method allowed selective and sensitive analysis for detection of urinary androgenic steroids. The experiments showed that the high-resolution MS method is clearly more efficient than the low-resolution MS technique for the detection of many urinary steroids. However, comprehensive sample clean-up procedures also might be needed especially in confirmation analysis to increase detectability.

POLAR EXPONENTIAL GRID와 장방형격자 영상시스템의 영상분해도 및 영상처리능력 비교 (A Comparison of System Performances Between Rectangular and Polar Exponential Grid Imaging System)

  • Jae Kwon Eem
    • 전자공학회논문지B
    • /
    • 제31B권2호
    • /
    • pp.69-79
    • /
    • 1994
  • The conventional machine vision system which has uniform rectangular grid requires tremendous amount of computation for processing and analysing an image especially in 2-D image transfermations such as scaling, rotation and 3-D reconvery problem typical in robot application environment. In this study, the imaging system with nonuiformly distributed image sensors simulating human visual system, referred to as Ploar Exponential Grid(PEG), is compared with the existing conventional uniform rectangular grid system in terms of image resolution and computational complexity. By mimicking the geometric structure of the PEG sensor cell, we obtained PEG-like images using computer simulation. With the images obtained from the simulation, image resolution of the two systems are compared and some basic image processing tasks such as image scaling and rotation are implemented based on the PEG sensor system to examine its performance. Furthermore Fourier transform of PEG image is described and implemented in image analysis point of view. Also, the range and heading-angle measurement errors usually encountered in 3-D coordinates recovery with stereo camera system are claculated based on the PEG sensor system and compared with those obtained from the uniform rectangular grid system. In fact, the PEC imaging system not only reduces the computational requirements but also has scale and rotational invariance property in Fourier spectrum. Hence the PEG system has more suitable image coordinate system for image scaling, rotation, and image recognition problem. The range and heading-angle measurement errors with PEG system are less than those of uniform rectangular rectangular grid system in practical measurement range.

  • PDF

Reservoir Characterization using 3-D Seismic Data in BlackGold Oilsands Lease, Alberta Canada

  • Lim, Bo-Sung;Song, Hoon-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2009년도 특별 심포지엄
    • /
    • pp.35-45
    • /
    • 2009
  • Reservoir Characterization (RC) using 3-D seismic attributes analysis can provide properties of the oil sand reservoirs, beyond seismic resolution. For example, distributions and temporal bed thicknesses of reservoirs could be characterized by Spectral Decomposition (SD) and additional seismic attributes such as wavelet classification. To extract physical properties of the reservoirs, we applied 3-D seismic attributes analysis to the oil sand reservoirs in McMurray formation, in BlackGold Oilsands Lease, Alberta Canada. Because of high viscosity of the bitumen, Enhanced Oil Recovery (EOR) technology will be necessarily applied to produce the bitumen in a steam chamber generated by Steam Assisted Gravity Drainage (SAGD). To optimize the application of SAGD, it is critical to identify the distributions and thicknesses of the channel sand reservoirs and shale barriers in the promising areas. By 3-D seismic attributes analysis, we could understand the expected paleo-channel and characteristics of the reservoirs. However, further seismic analysis (e.g., elastic impedance inversion and AVO inversion) as well as geological interpretations are still required to improve the resolution and quality of RC.

  • PDF

어깨 통증 양상으로 나타난 급성 경추부 신경뿌리병증 환자의 침도치료를 중심으로 한 한의치료 1례 (A Case Report of Korean Medicine Treatment Focused on Acupotomy Therapy for Acute Cervical Radiculopathy Presenting with Shoulder Pain)

  • 김태형;박다솔;임정태;최가원
    • Korean Journal of Acupuncture
    • /
    • 제41권2호
    • /
    • pp.51-57
    • /
    • 2024
  • This case report aims to illustrate the diagnostic challenge and effective management of acute cervical radiculopathy presenting as shoulder pain, differentially diagnosed through physical examinations, and subsequently treated with acupotomy. A male patient in his late 20s with no significant medical history or comorbidities reported acute left shoulder pain upon awakening, rated at a severity of 7 on the numeric rating scale (NRS). Initial physical evaluations of the shoulder assembly revealed no abnormalities, but a positive Spurling test, relief with cervical distraction, and diminished sensation across the left C5~C8 dermatomes pointed towards a cervical spine origin. Immediate acupotomy at identified tender points significantly reduced pain, with additional therapies enhancing recovery. Pain was eliminated after the second treatment, and this resolution was sustained at the 4-week follow-up, confirming the treatment's effectiveness and verifying the absence of adverse effects. This case presents the critical need for precise diagnosis in cases of neck and shoulder pain. Additionally, the employment of acupotomy provided a swift and effective resolution of symptoms in acute cervical radiculopathy, showing its value in clinical practice.

역상 액체 크로마토그래피에서 페놀류의 분리 최적화 및 미량 페놀류의 농축-분리에 관한 연구 (A Study on Optimization for Separation of Phenols and Preconcentration-Separation of Trace Phenols in Reversed-Phase Liquid Chromatography)

  • 이대운;이성원;소민정;조병련
    • 대한화학회지
    • /
    • 제37권5호
    • /
    • pp.513-522
    • /
    • 1993
  • 본 연구는 역상 액체 크로마토그래피에서 25가지 페롤류를 분리-분석하기 위한 용매의 최적 조건을 결정하고, 미량의 페놀류를 농축-분리하는데 그 목적을 두었다. 페놀류를 클로로 페놀, 메틸 페놀과 니트로 페놀로 분류하고 각각을 사성분 혼합 용매 시스템을 도입하여 최적 분리조건을 결정하였다. 분리 최적화는 통계적인 심플렉스 방법으로 overlapping resolution maps(ORM)를 사용하여 최적 용매조성을 결정하였으며, pH와 온도의 최적화 효과도 알아보았다. 또한 분리도를 향상시키고 분석시간을 줄이기 위해서 ORM-Prism 방법을 사용한 등선택성 다성분 기울기 용리 시스템을 도입하였다. 환경 오염수로부터 미량의 페놀류를 농축-분리하기 위해서 비극성 흡착제인 XAD-2와 강음이온교환 수지인 Dowex 1-X8로 구성되는 직렬 컬럼을 사용하여 그 농축-분리 성능을 평가하였다. 농축 효율을 평가하기 위해서 시료용액의 부피를 1L까지 증가시켰을 때 페놀을 제외한 모든 페놀류는 90% 이상의 회수율을 나타내었고, 검출 한계는 5ppb이었다. 한편 시판의 C18 카트리지법과 비교한 결과 XAD-2/Dowex 1-X8 법의 농축 효율과 선택성이 좋음을 알았다.

  • PDF

Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가 (The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery)

  • 김지현;손현수;이주영;박훈희
    • 핵의학기술
    • /
    • 제21권2호
    • /
    • pp.55-64
    • /
    • 2017
  • 최근 SPECT/CT의 보급과 함께 다양한 영상보정 방법들을 빠르고 정확하게 적용할 수 있게 되면서, 영상품질 향상과 더불어 정량적 정확성까지 기대할 수 있게 되었다. 그중 Collimator Detector Response (CDR) 회복(recovery)은 검출기면의 거리로부터 발생된 blurring 효과를 보상하여 분해능 회복을 목적으로 하는 보정방법이다. 본 연구에서는 SPECT/CT 영상에서 CDR recovery 가 적용되었을 때 검출거리 변화에 따른 정량적 변화를 알아보고자 하였다. 검출거리의 변화에 따른 획득 계수의 차이를 알아보고자 검출거리를 궤도방식(obit type)에 따라 Circular는 X, Y축 반경 30 cm, Non-Circular는 X, Y축 반경 21 cm, 10 cm, Non-Circular Auto(=Auto Body Contouring_ ABC, spacing limit 1 cm)로 설정하였고, 재구성 방법은 CDR recovery(CDRr)의 사용 유/무에 따른 계수 회복 차이를 알아보고자 OSEM (w/o CDRr)와 Astonish(3D-OSEM with CDRr)로 구분하여 적용하였다. 이 때 감쇠, 산란, 붕괴 보정은 모든 영상에 공통 적용하였다. 정량적 평가를 위해 교정인자(calibration factor_CF) 산출을 목적으로 교정영상(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, 물 9293 ml)을 획득하였고, 팬텀 실험을 위하여 50 cc 주사기에 물 31 ml를 채우고 $^{99m}TcO_4$ 123.3 MBq를 설정하여 팬텀영상을 획득하였다. 팬텀 영상에서 주사기 전체 체적에 VOI(volume of interest)를 설정하여 각 조건별로 총 계수 값을 측정하였고, CF를 적용시켜 설정된 참값 대비 추정값의 오차를 구하여 보정에 따른 정량적 정확성을 확인하였다. 산출된 CF는 154.27 (Bq/ml/cps/ml)이며, 각 조건별 영상에서 참값 대비 추정값은 OSEM에서 Circular 86.5%, Non-Circular 90.1%, ABC 91.3% Astonish에서 Circular 93.6%, Non-Circular 93.6%, ABC 93.9%으로 분석되었다. OSEM은 검출거리가 가까울수록 정확성이 높아졌으며, Astonish의 경우에는 거리와 상관없이 거의 유사한 값을 나타내었다. 오차는 OSEM Circular(-13.5%)에서 가장 크고, Astonish ABC(-6.1%)에서 가장 적었다. SPECT/CT영상에서 CDR recovery 적용을 통한 거리보상이 이루어 졌을 때 검출거리가 먼 조건에서도 근접검출과 거의 동일한 정량적 정확성을 보였고, 검출거리의 변화에 영향을 받지 않고 정확한 보정이 가능한 것을 확인 할 수 있었다.

  • PDF

IT재해복구 연관 프레임워크 비교분석을 통한 ISMS의 통합관리방안 (Research on Integrated Management of ISMS : Comparative Analysis of IT Disaster Recovery Framework)

  • 박유림;김병기;윤오준;길아라;신용태
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제23권3호
    • /
    • pp.177-182
    • /
    • 2017
  • 정보화 사회는 컴퓨터 및 통신이 발달하여 데이터를 수동으로 관리하기 어려운 정도로 데이터양이 방대해져서 데이터 관리에 어려움을 느끼고, 자연재해 및 해커의 공격 등으로 인해 데이터 손실, 서비스 이용 불가 등 다양한 IT 관련 보안사고가 발생하여 이를 원래대로 복구하기 위한 정보보호 관리체계가 필요하다. 정보보호 관리체계는 다양한 프레임워크들이 존재하는데, IT재해에 의해서 발생한 피해를 복구하기 위한 프레임워크는 Cyber Security Framework, Risk Management Framework, ISO/IEC 27001, COBIT 5.0이 존재하며, 각각의 프레임워크들 중에서 IT재해복구에 해당하는 항목들을 비교분석하고, IT재해가 발생한 경우 신속하게 해결하기 위한 하나의 통합적인 관리 방안에 대해 설명한다.