• Title/Summary/Keyword: Resolution improvement

Search Result 826, Processing Time 0.023 seconds

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

A Study on Improvement Technology of Image Resolution using Mobile Camera (이동 카메라를 이용한 사진 해상도 향상 기술 연구)

  • Buri Kim;Jongtaek Oh
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.93-98
    • /
    • 2023
  • Recently, as the size of display devices tends to increase and taking pictures with smart phones has become commonplace, the need for taking high-resolution pictures with smart phones is increasing. However, when the lens size of a camera is limited, such as in a smartphone, there is a physical limit to increasing the resolution of a photo. This paper is about a technique for increasing the resolution of a picture even when using a small-sized lens like a smartphone camera. It is to take multiple pictures while moving the smartphone, and to increase the resolution by combining these pictures into one picture. First of all, two pictures were taken while moving the smartphone horizontally for the 2D picture. Processes such as camera matrix estimation, and homograph inverse transformation were performed using OpenCV, and the resolution was improved by synthesizing one picture. It was confirmed that the resolution was improved in parts such as oblique lines or arcs on several test pictures.

Design of Gamma Camera with Diverging Collimator for Spatial Resolution Improvement (공간분해능 향상을 위한 확산형 콜리메이터 기반의 감마카메라 설계)

  • Lee, Seung-Jae;Jang, Yeongill;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.661-666
    • /
    • 2019
  • Diverging collimators is used to obtain reduced images of an object, or to detect a wide filed-of-view (FOV) using a small gamma camera. In the gamma camera using the diverging collimators, the block scintillator, and the pixel scintillator array, gamma rays are obliquely incident on the scintillator surface when the source is located the periphery of the FOV. Therefore, the spatial resolution is reduced because it is obliquely detected in depth direction. In this study, we designed a novel system to improve the spatial resolution in the periphery of the FOV. Using a tapered crystal array to configure the scintillation pixels to coincide with the angle of the collimator's hole allows imaging to one scintillation pixel location, even if events occur to different depths. That is, even if is detected at various points in the diagonal direction, the gamma rays interact with one crystal pixel, so resolution does not degrade. The resolution of the block scintillator and the tapered crystal array was compared and evaluated through Geant4 Application for Tomographic Emission (GATE) simulation. The spatial resolution of the obtained image was 4.05 mm in the block scintillator and 2.97 mm in the tapered crystal array. There was a 26.67% spatial resolution improvement in the tapered crystal array compared to the block scintillation.

Video Rate Image Signal Processing for Optical Coherence Tomography (광학 영상기를 위한 실시간 영상 신호 처리에 관한 연구)

  • 나지훈;이병하;이창수
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.239-248
    • /
    • 2004
  • Optical coherence tomography(OCT) is high resolution imaging system which can see the cross section of microscopic organs in the living tissue. In this paper, we analyze the relation between the light source and the resolution of modulated signal in Michelson interferometer. We construct 1-D OCT signal processing hardware such as amplifiers, filters, and demodulate electronic signals from the photo detector. In order to get 2-D OCT image, the synchronization among optical delay line, sample stage and A/D converter is dealt with. In experiments, we verify analog and digital signal processing blocks which apply to the stacks of glasses. Finally we aquire high resolution 2-D OCT image with respect to the onion tissue. We expect that this result can be applied to the medical instrument through performance improvement.

Design of Low Power Capacitive Sensing Circuit with a High Resolution in CMOS Technology

  • Jung, Seung-Min
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.3
    • /
    • pp.301-304
    • /
    • 2011
  • This paper describes the possibility of a low-power, high-resolution fingerprint sensor chip. A modified capacitive detection circuit of charge sharing scheme is proposed, which reduces the static power dissipation and increases the voltage difference between a ridge and valley more than conventional circuit. The detection circuit is designed and simulated in 3.3V, 0.35${\mu}$m standard CMOS process, 40MHz condition. The result shows about 27% power dissipation reduction and 90% improvement of difference between a ridge and valley sensing voltage. The proposed circuit is more stable and effective than a typical circuit.

Resolution Improvement of Ultrasound Signal Using Kalman Filter (칼만 필터를 이용한 초음파 신호의 해상력 향상)

  • Woo, Kwang-B.;Nam, Sang-E.;Shin, Dong-H.;Chin, Young-M.;Lee, Sung-M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1985 no.06
    • /
    • pp.15-19
    • /
    • 1985
  • This study deals with a kind of signal processing, Kalman filtering techniques, which are applied to ultrasound signal to improve resolution capability. The main advantage of Kalman filter algorithm for the analysis of reflected ultrasound signal is its recursive structure which can be easily adapted to time-varing system. In state-space description of the system, the 6th order system produces the best spectral approximation to the source pulse. As a result of spectrum analysis, 6th order estimator for two closely spaced (0.5mm) reflectors enhance resolution by 4dB - 10dB. By using this result, the possibility to detect even minute tumor is found.

  • PDF

A Study on the improvement a Resolution of the Ultrasound Imaging System (초음파 영상장치에서 해상도 향상에 관한 연구)

  • Lee, Hoo-Jeong;Kim, Young-Kil;Lee, Haing-Sei
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1235-1238
    • /
    • 1987
  • In this paper, a new focusing method, to be called the sampled delay focusing (SDF), is proposed. This method improves the lateral resolution in ultrasound imaging system. In SDF, the analog delay lines are no longer necessary because sampling sum process can replace the conventional delay sum process. Also, this method offers continuous dynamic focusing on the resolution pixel basis if the maximum delay time is less than the sampling interval. Second order sampling is adopted in order to extend the sampling interval.

  • PDF

Capacitive Sensing Circuit for Low Power and High Resolution

  • Jung, Seung-Min;Yeo, Hyeop-Goo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.692-695
    • /
    • 2011
  • This paper describes the possibility of a low-power, high-resolution fingerprint sensor chip. A modified capacitive detection circuit of charge sharing scheme is proposed, which reduces the static power dissipation and increases the voltage difference between a ridge and valley more than conventional circuit. The detection circuit is designed and simulated in 3.3V, $0.35{\mu}m$ standard CMOS process, 40MHz condition. The result shows about 35% power dissipation reduction and 90% improvement of difference between a ridge and valley sensing voltage. The proposed circuit is more stable and effective than a typical circuit.

  • PDF

Improvement of Microstep Characteristics in Hydrostatic Table with Ballscrew (볼스크류로 구동되는 유정압테이블의 미소이송특성 향상)

  • 황주호;박천홍;이찬홍;이후상
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 1998
  • Microstep characteristics largely depends on the variation of friction force induced by the geometric accuracy of ballscrew, guide rail and the control characteristics of servo unit. In this paper, for improving the microstep characteristics of hydrostatic table with ballscrew, microstep resolution according to the control mode of servo amplifier and response characteristic by the variation of integral gain are tested and compared. Relationship between micro motion behavior of hydrostatic table and the output torque is also tested for acquiring the effective variables on control characteristics. From the results. it is confirmed that the torque control mode has a advantage in microstep resolution, and more stable than velocity control mode in low feed rate, and by the increase of integral gain in the elastic motion realm, response characteristics can be improved.

  • PDF

Improvement of Dynamic encoding algorithm with history information (동부호화 최적화 기법의 성능개선을 위한 과거 검색정보의 활용)

  • Park, Young-Su;Kim, Jong-Wook;Kim, Yeon-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.111-113
    • /
    • 2006
  • DEAS is an direct searching and optimization method that based on the binary code space. It can be classified as an direct hill climbing searching. However, because of binary code space based searching, the searching in low resolution has random property. As the resolution of code increases during the search, its property of searching changes like that of hill climbing search. This paper propose a method for improving the performance of minimum seeking ability of DEAS with history information. The cost evaluation is increased. However the minimum searching ability of DEAS is improved along the same starting resolution.

  • PDF