• Title/Summary/Keyword: Resistive Load

Search Result 108, Processing Time 0.024 seconds

Resistive Current Mode Control for the Solar Array Regulator of SPACE Power System (인공위성 시스템을 위한 태양전지 전력조절기의 저항제어)

  • Bae, Hyun-Su;Yang, Jeong-Hwan;Lee, Jae-Ho;Cho, Bo-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.535-542
    • /
    • 2006
  • A large signal stability analysis of the solar array regulator system is performed to facilitate the design and analysis of a Low-Earth-Orbit satellite power system. The effective load characteristics of every controllable method in the solar array system are classified to analyze the large signal stability. Then, using the state plane analysis technique, the stability of various equilibrium points is analyzed. A nonlinear transformation algorithm, which changes the effective load characteristic of the solar array regulator as constant resistive load, is also proposed for the large signal stability. The proposed resistive current mode control system can control the solar array output for purposes such as peak power tracking control and battery charging control. For the verification of the proposed large signal analysis and resistive current mode control, a solar array regulator system consisting of two 100W parallel module buck converters has been built and tested using a real 200W solar array.

Wireless Parallel Operation of a Three-phase Modular UPS Inverter using Resistive Droop Control (저항성 수하 제어를 적용한 3상 모듈형 UPS 인버터의 비통신선 방식 병렬 운전)

  • Kim, Seon-Tae;Ji, Jun-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1672-1681
    • /
    • 2016
  • This paper proposes a wireless parallel operation method of three-phase modular UPS inverter using resistive droop control. Furthermore, it applies a virtual resistor to droop control so that the output impedance of UPS inverter gets closer to resistive. It makes resistive droop control effective. The simulation using PSIM was performed in order to verify the validity of proposed algorithm. After consisting two-parallel system with three-phase modular UPS inverter, the experiment according to resistive load was conducted. It demonstrated the performance of current sharing and power sharing.

Analysis of Resistive Exercise Characteristics for Newly Developed Sonic Vibration Leg Press (새로이 개발된 음파 진동 레그프레스의 저항 운동 특성 분석)

  • Cho, Young-Kuen;Hwang, Sun-Hong;Kim, Hyun-Dong;Kim, Young-Ho;Min, Jin-Young;Kim, Han-Sung;Lim, Do-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1704-1708
    • /
    • 2008
  • Many studies have emphasized the importance of resistive exercise to maintain a healthy human body, particular in prevention of weakening of physical strength. Recently, some studies advocated that an application of vibration as a supplementary means in a regular training was effective in encouraging physical strength. Aim of the current study was, therefore, to identify if an application of vibration in a resistive exercise was effective in encouraging physical strength as that in a regular training. A 3-dimensional virtual lower extremity model for a healthy male and virtual leg-press model were generated and synchronized. Dynamic leg-press exercises on a slide machine with/without extra load and on a footboard with vibration as well as on a slide machine with extra load were analyzed. The results of the current indicated that the application of the vibration on the dynamic leg-press exercise might be not greatly effective in encouraging physical strength, compared with the dynamic leg press exercise with extra load. It was, however, thought that the application of the vibration might be helpful to elderly individuals because the reduced maximum muscle strength appeared by the effect of the vibration may avoid a muscular spasm, which can be driven from a high muscle strength sometimes produced during the leg-press exercise with extra load.

  • PDF

A Study on the Oscillation Region and the Variation of Negative Resistance in Transistor Oscillators (트란지스터 발진기의 발진영역과 부저항의 변화에 관한 연구)

  • 이종각
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.3
    • /
    • pp.15-26
    • /
    • 1971
  • The paper presents a new method for analyzing oscillation regions of transistor oscillators. In transistor feedback oscillators oscillation region appears as a circle in feedback impedance complex plane. When the resistive component of feedback impedance is fixed and the reactive component of feedback impedance is varied or vice versa, the locus of maximum negative output conductance becomes hyperbola. In transistor crystal oscillators oscillation region is determined by two circles which make real part and imaginary part of input impedance zero in load impedance complex plane. When the resistive compoment of load impedance is fixed and the reactive colnponent of load impedance is varied or vice versa, the loci of maximum or minimum resistive component of input impedance become straight lines.

  • PDF

Modeling of Load Element for a Low Voltage DC Distribution System (저전압 DC 배전시스템 구성요소의 부하 모델링)

  • Gwon, Gi-Hyeon;Han, Joon;Oh, Yun-Sik;Kim, Eung-Sang;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.113-121
    • /
    • 2014
  • At the end of the 19th century, a battle known as the War of the Currents was fought over how electricity would be generated, delivered, and utilized. In this day and age, there has been a growing interest in Green Growth policies as countermeasures against global warming. As a result of these policies, the use of new and renewable energy needed a power converter to replace fossil fuels has expanded. To reduce power consumption through high efficiency of conversion, Low Voltage DC (LVDC) distribution systems are suggested as an alternative. In a DC distribution system, DC loads are very efficient due to decrease the stages of power conversion. If the LVDC distribution system is adopted, not only DC load but also existing AC loads should be connected with LVDC system. Thus, the modeling of two loads is needed to analyze the DC distribution system. This paper, especially, is focused on the modeling of resistive load and electronic load including power electronic converters using ElectroMagnetic Transient Program (EMTP) software.

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.

Evaluation on Blast Resistance Performance of Reinforced Concrete Wall Strengthened by FRP Sheet (FRP 시트로 보강된 철근콘크리트 벽체의 방호성능 평가)

  • Lee, Kun-Ho;Kim, Jae-Min;Kim, Jae Hyun;Lee, Sang-Hoon;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.151-160
    • /
    • 2022
  • Owing to the recent increase in the frequency of explosion accidents, blast resistive design has garnered attention to reduce the damage of important structural elements. However, domestic research on the blast resistive structures is still insufficient, and domestic design guideline against blast loads are not documented yet. In this study, a numerical study on the RC blast resistive walls, where the test variable was the presence of FRP sheet, was performed using LS-DYNA program. Based on the numerical results, displacement-time hysteretic curve, pressure-impulse diagram, and fragility curve of the test specimens were derived. It was shown that the FRP sheet strengthening method is efficient to improve the blast resistive performance of the RC wall. Also, the strengthening effect of FRP sheet on the RC wall was stronger when the magnitude of the blast load was greater.

A Study on Load Cell Development by means of a Nano-Carbon Piezo-resistive Composite and 3D printing (탄소나노튜브 복합소재 전왜 특성과 3D 프린팅을 활용한 로드셀 개발 연구)

  • Kang, Inpil;Joung, Kwan Young;Choi, Beak Gyu;Kim, Sung Yong;Oh, Gwang Won;Kim, Byung Tak;Baek, Woon Kyung
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.97-102
    • /
    • 2020
  • This paper presents the basic research for the design and fabrication of a 3D-printed load cell made of NCPC (nano-carbon piezo-resistive composite). We designed a structure that can resonate at a low frequency range of about 5-6 Hz with ANSYS using sensitivity analysis and a response surface method. The design was verified by fabricating the device with a low-quality commercial 3D printer and ABS filament. We conducted a feasibility test for a commercial sensor using 1000 cyclic load tests at 0.3 Hz in a material testing system. A manufacturing process for the 3D printer filament based on the NCPC was also developed using the nano-composite process.

Researching of the Tesla's Bifilar Coils, as a Sources of Electrical Energy

  • CHERVINSKY, L.;USENKO, S.;SPODOBA, M.
    • The Korean Journal of Food & Health Convergence
    • /
    • v.5 no.4
    • /
    • pp.19-23
    • /
    • 2019
  • In recent years, the Internet was a lot of information on the use of Tesla coils bifilar [1] in conjunction with induction cooker, for "free" electricity during power resistive load, including different incandescent lamps. With the development of scientific and technological progress, the demand for electricity in each year is increasing, and at the same time, the need to increase the capacity of electricity production, which entails large investments and, consequently, increase of prices for consumers. As before today, the search for free electric energy is an up-to-date and still open topic. The purpose of research - simplification of information on the possibility of using bifilar coils as an electric current source in conjunction with induction cooker. Consequently, it can be concluded from the above that the use of Tesla coils in combination with induction cooker has very low k.k.d. and it is not possible to obtain excessive electric energy using the Tesla coil under the connection schemes considered.

Increasing the performance of energy harvesting in vibration mode shapes

  • Jabbari, Majid;Ghayour, Mostafa;Mirdamadi, Hamid Reza
    • Advances in Computational Design
    • /
    • v.1 no.2
    • /
    • pp.155-173
    • /
    • 2016
  • This paper presents a method of design for the energy harvesting of a piezoelectric cantilever beam. Vibration modes have strain nodes where the strain distribution changes in the direction of the beam length. Covering the strain nodes of the vibration modes with continuous electrodes effects a cancellation of the voltages outputs. The use of segmented electrodes avoids cancellations of the voltage for multi-mode vibration. The resistive load affects the voltage and generated power. The optimum resistive load is considered for segmented and continuous electrodes, and then the power output is verified. One of the effective parameters on energy harvesting performance is the existence of concentrated mass. This topic is studied in this paper. Resonance and off-resonance cases are considered for the harvester. In this paper, both theoretical and experimental methods are used for satisfactory results.