• Title/Summary/Keyword: Resistant performance

Search Result 673, Processing Time 0.027 seconds

Evaluation of Fire-Resistant Performance for Polypropylene Fiber-Mixed Mortar (폴리프로필렌 섬유 혼입 모르타르의 내화성능 평가)

  • Lee, Chan-Young;Shim, Jae-Won;Ahn, Tae-Song;Lim, Chae-Hyeok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.473-476
    • /
    • 2006
  • In this study, evaluation of fire-resistant performance for polypropylene fiber-mixed mortar was performed to establish specification for stability of tunnel structure against fire afterward. In the fire-resistant performance test with mix proportion of polypropylene fiber, cracks were observed for mortar under 0.15% of fiber content, but micro-cracks were remarkably reduced for mortar more than 0.2% of fiber content. From the results, we are concluded that optimal mix proportion of polypropylene fiber is $0.20{\sim}0.25%$.

  • PDF

Evaluation of Fire-Resistant Performance for Tunnel Lining Concrete with Heating Temperature-Time Curves (시간가열온도곡선에 따른 터널라이닝 콘크리트의 내화성능 평가)

  • Lee, Chan-Young;Shim, Jae-Won;Ahn, Tae-Song;Lim, Chae-Hyeok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.477-480
    • /
    • 2006
  • In this study, evaluation of fire-resistant performance for polypropylene fiber-mixed mortar was performed to establish specification for stability of tunnel structure against fire afterward. In the fire-resistant performance test with mix proportion of polypropylene fiber, cracks were observed for mortar under 0.15% of fiber content, but micro-cracks were remarkably reduced for mortar more than 0.2% of fiber content. From the results, we are concluded that optimal mix proportion of polypropylene fiber is $0.20{\sim}0.25%$.

  • PDF

Factors that Affect the Confidence of Performance of Nurses at Small and Medium-sized Hospitals in the Control of Infections Caused by Multidrug-Resistant Organisms (중소병원 간호사의 다제내성균 감염관리 수행자신감에 미치는 영향요인)

  • Choi, Mi Jung;Lee, Mi Hyang;Jeong, Sun Young;Song, Min Sun
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.27 no.3
    • /
    • pp.321-329
    • /
    • 2020
  • Purpose: This study was conducted to assess the factors that affect the confidence of nurses at small and medium-sized hospitals in the control of infections caused by multidrug-resistant organisms and to establish basic data for the interventional strategy to improve the nurses' execution of the control of infection caused by multidrug-resistant organisms. Methods: A total of 154 nurses working at four small and medium-sized hospitals situated in City C were selected as participants of this study. Data were collected using a structured questionnaire and analyzed using the IBM SPSS 21.0 software. Results: Confidence in controlling infections caused by multdrug-resistant organisms had a positive correlation with the level of knowledge of this control and the health beliefs of the nurses. Factors that affect nurses' confidence in controlling infections caused by multidrug-resistant organisms included perceived benefits (β=.431, p<.001) and knowledge (β=.354, p<.001) with an explanatory power of 36.4%. Conclusion: It was found that the nurses have higher confidence in executing their duties with higher perceived benefits of and knowledge about the control of infections caused by multidrug-resistant organisms. As such, it is deemed necessary to establish strategies to elevate the advantages of and knowledge about infection prevention activities at the time of training/education on controlling infections caused by multidrug-resistant organisms.

Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar (복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구)

  • Park, Keum Sung;Bae, Kyu Woong;Kang, Hyun Sik;Lim, Seo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2007
  • The purpose of this paper is to evaluate the fire resistant performances of load-bearing wall using both composite and steel stud panel infilled with light-weight formed mortar under axial loading according to KS F 2257(1999). The minimum requirement of 2 hours fire resistant rating is needed for the residential and commercial buildings under the fire regulation of Korea. From test results, it is found that two types of specimen composed of the hybrid stud and steel stud panel filled with light-weight formed mortar fited in with the requirement of 2 hours fire resisting rate for the load-bearing wall. In the conclusions, the specimen with hybrid stud shows predominating fire-resistant performance on the adiabatic effects rather than that of the steel stud specimen.

Effect of lower extremity resistance exercise on gait performance in a patient with systemic lupus erythematosus with cerebral infarction and lower extremity vasculitis: a case study

  • Oh, Yongseop;Woo, Youngkeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.106-112
    • /
    • 2016
  • Objective: This study was conducted to investigate the effects of resistant exercise on the gait performance of a patient with systemic lupus erythematosus (SLE) patient. Design: A case study. Methods: A 30-year-old male adult who had been diagnosed with systemic lupus erythmatosus (SLE) in April 2013, right middle cerebral artery infarction, and with left hemiplegia agreed to participate in this case study. Patient was unable to walk due to being affected with adynamia. Due to developing necrotizing vasculitis on the left lower extremity, patient underwent a myotomy on the left thigh. The patient was trained with a progressive resistant exercise program for 8 weeks. An intensity of 15 RM was used for the resistant exercises and the resistance level was increased progressively in order to improve the muscle power of the patient. Methods used to increase resistance included changing positions, providing mechanical resistance instead of manual resistance, transitioning from open kinetic chain to closed kinetic chain exercises, and changing the colors of the theraband to those with increase level of resistance. Outcome measures included the 5-repetition sit-to- stand test (5RSST), Timed Up & Go (TUG), and 10-meter walk test (10MWT). In addition, the GAITRite was used to assess the spatio-temporal gait variables, including gait speed, cadence, stride length of the left side, and double limb support pre and post-intervention. Results: The patient was able to perform sit-to- stand after two weeks of performing the resistant exercises. The patient was able to walk after 4 weeks, and the patient's overall gait performance had improved after 8 weeks. All of the variables had improved after each week. Conclusions: The results of this case study may be used to enhance future efforts to objectively evaluate resistant exercises during gait performance in persons affected by SLE.

Performance Evaluation of Earthquake Resistant Caisson Type Quay Walls (케이슨식 안벽의 내진보강 성능 평가 -수치해석적 측면에서-)

  • 권오순;황성춘;박우선
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.129-139
    • /
    • 2000
  • The liquefaction of reclaimed land generally caused the harbor facilities to hazards. In Korea, the major harbor quay walls are gravity type and the gravity quay wall is not a good earthquake resistant structure. Recently, various earthquake resistant quay walls have been suggested, but the study on the efficiency of reinforced quay wall was not much performed. In this study, numerical analysis is carried out for performance evaluation of easily adoptable earthquake resistant quay walls. The results of numerical analysis are compared with shaking table test that is performed at the same cross-section.

  • PDF

Strengthening of an Existing Bridge for Achievement of Seismic Performance (내진성능 확보를 위한 기존교량의 보강)

  • Kook, Seung-Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.2
    • /
    • pp.181-187
    • /
    • 2009
  • After introduction of the earthquake resistant design code, it is required to achieve seismic performance of existing bridges as well as earthquake resistant design of new bridges. The achievement of seismic performance for existing bridges should satisfy the no collapse requirement based on the basic concept of earthquake resistant design, therefore, various methods with different strengthening scale should be suggested according to bridge types and importance categories. At present for typical bridges, most studied and applied strengthening methods are bearing change, pier strengthening and shear key installation for improvement of seismic performance. In this study a typical existing bridge, for which earthquake resistant design is not considered, is selected as an analysis bridge. Design changes are carried out to satisfy the no collapse requirement by way of the ductile failure mechanism and seismic performances are checked. It is shown that the seismic performance of existing bridges can be achieved by way of redesign of bridge system, e.g. determination of pier design section for substructure and change of bearing function for connections between super/sub-structure.

Factors Influencing Performance of MultiDrug-Resistant Organisms Infection Control in Nurses of General Hospital (종합병원 간호사의 다제내성균 감염관리 수행도에 영향을 미치는 요인)

  • Ryu, Jeonglim;Ko, Yu Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.2
    • /
    • pp.149-160
    • /
    • 2016
  • Purpose: The purpose of this study was to identify factors influencing performance of MultiDrug-Resistant Organisms (MDROs) infection control by nurses in general hospitals. Methods: The research design was a descriptive survey design using convenience sampling. Data were collected from 130 nurses working in 6 general hospitals. Collected data were analyzed using SPSS/WIN 21.0 program for descriptive statistics, t-test, ANOVA, Pearson correlation coefficients and multiple regression analysis. Results: General hospital nurses' MDROs infection control performance was influenced by their awareness of environmental safety, recognition of MDROs infection control, number of beds in the hospital, whether nurses had nursing experience with infection control and guidelines for MDROs infection control. The most important predictors of MDROs infection control performance were awareness of environmental safety and recognition of MDROs infection control. Conclusion: Findings indicate that it is necessary to include content related to awareness of environmental safety and recognition of infection control in developing MDROs infection control education programs for general hospital nurses.

Survey of Building Structural Elements located at Underground for Improvement of Fire Resistant Performance (건축물 지하 구조부재의 내화성능 개선에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.76-84
    • /
    • 2008
  • Researches on fire resistant performance of primary structural elements such as columns and beams located at above the ground have actively been doing than those located at the below the ground from many researchers. But the structural elements such as columns at underground is very important in aspects of not only structural performance but also fire environment. The columns at the basement carry all the structural loads from the above and that means very critical in fire circumstances than that located at above the grounds. To evaluate the fire resistance performance of primary structural elements located at below the ground we conducted several sorts of surveys that contained fire regulations from several countries and structural types, materials and status of passive fire protection methods.

Factors Affecting Performance of the Infection Control of Carbapenem Resistant Enterobacteriaceae of Nursing Staffs in Long-term Care Hospitals (요양병원 간호인력의 카바페넴 내성 장내세균속균종 감염관리 수행 정도에 미치는 요인)

  • Kim, Gyuri;Lee, Jong-Eun
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.29 no.2
    • /
    • pp.204-215
    • /
    • 2022
  • Purpose: This study aimed to identify factors affecting the carbapenem-resistant enterobacteriaceae (CRE) infection control performance of nursing staff, who closely contact patients with CRE in long-term care hospitals. Methods: A cross-sectional study design was used. A total of 135 nursing staffs working in seven long-term care hospitals in the southern and northern areas of the K province in Korea were included. We measured the CRE infection control general characteristics, knowledge, perception, and performance. Results: The main factors affecting the CRE infection control performance were education, knowledge, and perception. The model explained the 60.8% total variance in CRE infection control. Conclusion: Appropriate infection control strategies should be prepared to provide high quality nursing care and prevent the spread of CRE infection in long-term care hospitals. Establishing an efficient infection control system in long-term care hospitals is necessary.