• 제목/요약/키워드: Resin types

검색결과 596건 처리시간 0.027초

Manufacturing Characteristics of Wood ceramics from Thinned Small Logs (I) - Resin Impregnation Rate and Bending Strength -

  • Oh, Seung-Won;Hirose, Takashi;Okabe, Toshihiro
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권4호
    • /
    • pp.51-55
    • /
    • 2000
  • The woodceramics which are new porous carbon materials were obtained by carbonizing from thinned small log of Aomori HIBA (Thujopsis dolabrata S. et. Z. var. hondae M.) impregnated with phenol resin in a vacuum furnace. During the carbonization process, the resin changes into glassy carbon, which has superior property. The resin impregnation rate and bending strength depend on the types of board and density. In this paper, the manufacturing method of woodceramics made from thinned small logs of Aomori HIBA was introduced and some properties were examined.

  • PDF

가시광선과 아르곤 레이저에 의한 복합레진 중합 효과의 비교 연구 (A COMPARATIVE STUDY OF THE EFFECTIVENESS IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND ARGON LASER SOURCE)

  • 전상언;김용기
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.327-346
    • /
    • 1996
  • The purpose of this study was to evaluate the shear bond strengths, microhardness, compressive strength and contraction gap at the resin-tooth interface of two types of composite resins polymerized with visible light and argon laser sourse. The results from the present study can be summarized as follows ; 1. Resin samples polymerized either by argon laser or visible light did not show significant difference in their physical properties tested(p>.05). 2. The contraction gap at the resin tooth interface was found to be present in all samples but any significant difference between groups could not be established due to their variability. Although the superiority of argon laser over visible light in enhancing the physical properties of resin could not be elucidated in the present study, continous efforts are deemed to be worthwhile to investigate this area using different conditions and materials of experiment.

  • PDF

유지형태와 접착제 종류에 따른 수지 접착형 수복물과 법랑질간의 전단결합강도 및 파절양상에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH BETWEEN RESIN-BONDED RETAINERS AND ENAMEL ACCORDING TO THE ADHESIVE RESINS AND RETENTION TYPES)

  • 조미숙;양재호
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.662-684
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength between various resin-bonded retainers and enamel according to the adhesive resins and retention types and observe the bond filure modes with scanning electron microscope(SEM). For this purpose, the followin eight sub-groups were tested in shear bond strength : 1) electrochemically etched group(Verabond) using Panavia EX and Superbond C&B 2) tin-plated group(PG-S) using Panavia EX and Superbond C&B 3) salt-treated group(Verabond) using Panavia EX and Superbond C&B 4) meshtreated group(Verabond) using Panavia EX and Superbond C&B. Thermocycling test was conducted on the condition of 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$bath. Shear bond strength was measured by Instron Universal Testing Machine(medel 1125). The obtained results were as follows : 1. After thermocycling, the shear bond strengths of tin-plated group and electrochemically etched group were significantly greater than those of salt-treated group and mesh-treated group. And the shear bond strength of Panavia EX was greater than that of Superbond C&B with salt-treated group and tin-plated group(p<0.05). 2. Before thermocycling, electrochemically etched group using Superbond C&B produced the greatest shear bond strength(p<0.01). 3. The shear bond strength of electrochemically etched group using Superbond C&B was significantly decreased after thermocycling(p<0.01). 4. In observation of bond failure modes before thermocycling, Panavia EX highly exhibited enamel fracture. Tin-plated group using Superbond C&B adhesive failure between metal and resin and electrochemically etched group using Superbond C&B exhibited adhesive failure between enamel and rdsin. 5. In observation of failure modes after thermocycling, Panavia EX exhibited cohesive failure and Superbond C&B exhibited adhesive failure between resin and metal.

  • PDF

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

THE LEVEL OF RESIDUAL MONOMER IN INJECTION MOLDED DENTURE BASE MATERIALS

  • Lee Hyeok-Jae;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.360-368
    • /
    • 2003
  • Statement of Problem: The residual monomer of denture base materials causes hypersensitivity on oral mucosa and intereferes with the mechanical properties of the cured resin. The amount of residual monomer is influenced by materials, curing cycle, processing method, and etc. Purpose: The aim of this study was to investigate the residual methyl methacrylate(MMA) content of injection molded denture base polymer, and to compare this with the self-cured resin and the conventional compression molded heat-cured resin. Materials and Methods: Disc shaped test specimens (50mm in diameter and 3mm thick) were prepared in a conventional flasking technique with gypsum molding. One autopolymerized denture base resins (Vertex Sc. Dentimex. Netherlands) and two heat-cured denture base resins (Vertex RS. Dentimex. Netherlands, Ivocap. Ivoclar Vivadent, USA) were used. The three types of specimens were processed according to the manufacturer's instruction. After polymerization, all specimens were stored in the dark at room temperature for 7 days. There were 10 specimens in each of the test groups. 3-mm twist drills were used to obtain the resin samples and 650mg of the drilled sample were collected for each estimation. Gas chromatography (Agillent 6890 Plus Gas Chromatograph, Agillent Co, USA) was used to determine the residual MMA content of 10 test specimens of each three types of polymer. Results: The residual monomer content of injection molded denture base resins was $1.057{\pm}0.141%$. The residual monomer content of injection molded denture base resins was higher than that of compression molded heat cured resin ($0.867{\pm}0.169%$). However, there was no statistical significant difference between two groups (p>0.01). The level of residual monomer in self cured resin($3.675{\pm}0.791$) was higher than those of injection molded and compression molded heat cured resins (p<0.01). Conclusion: With respect to ISO specification pass / fail test (2.2% mass fraction) of residual monomer, injection molding technique($1.057{\pm}0.141%$) is a clinically useful and safe technique in terms of residual monomer.

미성숙 치아 모델에서 포스트의 종류와 크기가 치아의 파절 저항성에 미치는 영향에 관한 연구 (INFLUENCE OF POST TYPES AND SIZES ON FRACTURE RESISTANCE IN THE IMMATURE TOOTH MODEL)

  • 김종현;박성호;박정원;정일영
    • Restorative Dentistry and Endodontics
    • /
    • 제35권4호
    • /
    • pp.257-266
    • /
    • 2010
  • 본 연구의 목적은 미성숙 우치를 가타퍼챠 및 다양한 포스트와 코아 시스템을 이용하여 수복한 후 술식에 따른 파절 강도를 측정하였다. 우치의 백악상아경계 상방 8 mm, 하방 12 mm 지점을 절단하여 제작한 미성숙 우치 모델에서 가타퍼챠와 이원중합형 복합레진 LuxaCore로 코어 수복을 시행하거나, 각각 D.T. LIGHT-POST, ParaPost XT 및 다양한 크기의 EverStick Post와 LuxaCore로 수복하였다. 이후 시편을 72시간 동안 증류수에 저장한 후 6,000회의 thermocycling을 진행하였다. 실험적으로 치주인대의 물성을 재현하고, Instron에 시편을 45도로 위치시켜 압축부하를 가해 파절 강도를 측정하고, 파절 부위를 분석하였다. 실험 결과, 포스트를 이용하여 수복하였을 때 파절 강도가 통계적으로 유의하게 증가하였고(p < 0.05), 포스트의 종류 및 적합도는 결과에 통계적으로 유의한 차이를 나타내지 않았다. 대부분의 시편에서 수복 가능한 파절이 나타났으며, 실험군에 따른 파절 부위의 유의한 차이는 나타나지 않았다. 이상의 결과로 볼 때 미성숙 치아의 상기 치근 강화 술식은 치아의 파절 강도를 증가시키고, 포스트의 종류 및 적합도는 파절 저항성에 거의 영향을 미치지 않는 것으로 나타났다.

동시 경화 제작기법을 적용한 이종 수지 복합재의 열적/기계적 특성에 관한 실험적 연구 (Experimental Study on Thermal and Mechanical Characteristics of Two Resin Composites Using the Co-Curing Process)

  • 윤진영;최지덕;박철용;김영규
    • 한국군사과학기술학회지
    • /
    • 제23권5호
    • /
    • pp.475-484
    • /
    • 2020
  • Individual curing process of each layer in two resin composites can be caused the separation between two layers. In this study, co-curing process for two resin composites is suggested to improve the inter-layer bonding. Glass fiber reinforced composites with phenolic and epoxy resins were manufactured by co-curing process, and several types of glass/phenolic composites were considered to confirm the application on two resin composites. Experiments for smoke resistance, scratch resistance and flexural strength were carried out to verify requirements corresponding to thermal and mechanical environments. It was validated that two resin composites with phenolic resin impregnated prepreg exhibits good thermal and mechanical characteristics, and it can serve as highly effective composite structures in aerospace and many industry areas.

도재 라미네이트와 복합레진 수복 시 치간이개 양에 따른 접착계면의 응력분포에 관한 3차원 유한요소법적 연구 (THE EFFECT OF THE AMOUNT OF INTERDENTAL SPACING ON THE STRESS DISTRIBUTION IN MAXILLARY CENTRAL INCISORS RESTORED WITH PORCELAIN LAMINATE VENEER AND COMPOSITE RESIN: A 3D-FINITE ELEMENT ANALYSIS)

  • 홍준배;탁승민;백승호;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제35권1호
    • /
    • pp.30-39
    • /
    • 2010
  • 본 연구에서는, 삼차원 유한요소분석법을 이용하여 복합레진 및 도재 라미네이트로 전치부 치간이개를 폐쇄할 때, 치간이개의 간격과 수복방법이 수복물의 접착계면에서의 응력분포에 미치는 영향을 비교하였다. 복합레진 혹은 도재 라미네이트로 수복된 모습의 유한요소모델을 형성하여 접착계면에서의 von Mises stress 분포 양태를 분석하였다. 수복형태는 크게 네 가지 범주를 고려하였다. Type I, 복합레진으로 인접면을 최소한으로 수복하는 경우; Type II, 치아 삭제 없이 복합레진으로 순면의 절반까지 수복하는 경우; Type III, 치아삭제 후복합레진으로 순면의 2/3까지 수복하는 경우; Type IV, 도재 라미네이트로 수복하는 경우 이 실험의 한계 내에서 다음과 같은 결론을 내릴 수 있었다. 모든 수복형태에 대해 치간이개 간격이 넓어질수록 접착계면에서 발생하는 최대응력 값은 증가하였으며, 도재 라미네이트로 치간이개 부위를 수복한 경우(Type IV)가 복합레진으로 수복한 경우(Type I, II, III)에 비해 높은 최대응력값을 나타내었다. 그러나 치간이개 간격이 넓어질수록 도재 라미네이트와 복합레진에서 발생하는 최대응력값의 차리는 감소하였으며, 치간이개 간격의 증가에 따른 최대응력값의 증가율은 도재 라미네이트가 복합레진으로 수복하는 경우보다 낮았다.

THE FRACTURE CHARACTERISTICS OF GLASS FIBER POST AND CORE ON USING DIFFERENT TYPES OF CORE RESIN MATERIALS

  • Shim Dong-Wook;Shim June-Sung;Lee Seok-Hyung;Lee Keun-Woo
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.280-293
    • /
    • 2004
  • Statement of problem. Glass fiber post is one of recent developments to accommodate esthetic restoration for endodontically treated teeth. This has many advantages over conventional post system in physical properties, esthetic factor, risk of root and restoration fracture, adhesion to core, radiopacity, removal and retrievabilty, biocompatibility and chemical stability. Purpose. This in vitro study was to evaluate the most suitable type of resin core for the glass fiber post through surveying the fracture modes and the maximum load that fractures the tooth. Material and methods. 50 sound maxillary premolars restored with glass fiber posts($ParaPost^{(R)}$ Fiber White) and different types of resin cores(ParaCore, $Z100^{TM}$, $Rebilda^{(R)}$ and $Admira^{(R)}$) were prepared and loaded to faiure in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with resin and those of metal cast and core. With the data, Wilcoxon rank sum test was used to validate the significance between the test groups, and Tukey' s studentized range test was used to check if there is any significant statistical difference between each test group. Every analysis was approved with 95% reliance. Results. On measuring the maximum fracture load of teeth specimens, there was a significant difference between the maximum fracture loads of the tooth specimens. ParaCore showed the highest mean maximum fracture load followed by $Z100^{TM}$. And, the distribution of fracture mode of tooth specimens showed generally Type D, the three parted fracture of the core around the post was mostly seen(62.5%), and specifically, ParaCore showed 90% and $Z100^{TM}$ showed 100% Type D fracture. Conclusion. Referring to the values of maximum fracture load and mean compressive fracture load, ParaCore and $Z100^{TM}$ had high values and are recommended as tooth colored resin core material for glass fiber post. CLINICAL IMPLICATIONS. This study was carried out intending to be of aid in selecting the appropriate resin core for the glass fiber post. The dual cure type composite resin ParaCore and light cure type composite resin $Z100^{TM}$ have good properties and are recommended as tooth colored resin core material for glass fiber post.

Effects of Hardener and Extender Contents on Curing Behavior of Urea-Melamine-Formaldehyde Resin

  • Eom, Young-Geun;XU, Guang-Zhu;Lee, Young-Kyu;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권5호
    • /
    • pp.42-48
    • /
    • 2008
  • This study was conducted to discuss the effects of hardener and extender contents on peak temperature, reaction enthalpy (${\Delta}H$), gelation time, viscosity change, and pH value in three types of UMF (urea-melamine- formaldehyde) resin with the help of perpHecT LogR meter, differential scanning calorimetry (DSC), and advanced rheometric expansion system (ARES), The results indicated that the pH value of Control A steeply decreased to 5,2 in the early stage but relatively remained constant thereafter as in Synthesis 1 and Synthesis 2, The peak temperature and time decreased as well, whereas ${\Delta}H$ and viscosity increased with the increase of hardener content. On the other hand, ${\Delta}H$ was not changed up to the extender content of 5% and then decreased with its further addition, And the pH value and peak temperature showed no change with the increase of extender content at the hardener content of 5% in three types of UMF resin, The effect of hardener content in this experiment, however, appeared more conspicuous in Control A than in the other two types of Synthesis 1 and Synthesis 2, These results might be caused by higher molecular weight with longer chains of methylene ($-CH_2-$) and methylene ($-CH_2-O-CH_2-$) ether bridges or much more branched chains in Control A.