• Title/Summary/Keyword: Resin crown

Search Result 315, Processing Time 0.023 seconds

FINITE ELEMENT ANALYSIS OF STRESS TRANSMITTED TO THE PULPECTOMIZED PRIMARY CENTRAL INCISOR RECONSTRUCTED BY COMPOSITE RESIN CROWN (상악 유중절치의 치수치료후 치관수복에 대한 유한요소법적 분석)

  • Maeng, Myung-Ho;Kim, Yong-Kee;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.717-730
    • /
    • 1998
  • The Finite Element Analysis has been used for stress analysis of prosthesis, orthodontic or orthopedic appliances and filling materials. The primary purpose of the present studying was to evaluate the effectiveness of needle post in promoting the retention and integrity of composite crown restored on the pulpotomized primary central incisor. Three finite element models-natural tooth (Sample I), composite crown with (Sample II) and without (Sample III) needle post-were constructed and the stress distribution within each model were analyzed and compared one another. The results can be summarized as follows: 1. In sample I, the stress was shown to have distributed uniformly throughout the whole tooth even to the alveolar bone. 2. In sample II, the transmission of stress from the crown to the root area was shown to be very poor and irregular. 3. In sample III, the needle post was proved to be very effective in distributing the stress well to the aveolar bone which might help in maintaining the stability of crown restoration.

  • PDF

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN:THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON UPPER FIRST PREMOLAR CROWNS (IPS Empress 도재관의 파절강도 : 상악제1소구치에서 교합면 두께와 축면 경사도에 따른 영향)

  • Dong, Jin-Keun;Oh, Sang-Chun;Kim, Sang-Don
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.127-133
    • /
    • 1999
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the upper first premolar. After 10 metal dies were made fir each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results were : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (630N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength(378N). There were no significant differences of the fracture strength by axial inclination in same occlusal depth group. 2. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth.

  • PDF

Adsorption Characteristics of U ranium (VI) Ion on Cryptand Synthetic Resin Adsorbent

  • Kim, Hae-Jin
    • Journal of Integrative Natural Science
    • /
    • v.10 no.4
    • /
    • pp.225-231
    • /
    • 2017
  • Cryptand resins were synthesized by mixing 1-aza-18-crown-6 macrocyclic ligand with styrene divinylbenzene copolymer having 1%, 2%, 5%, and 10% crosslink by a substitution reaction. These synthetic resins were confirmed by chlorine content, elementary analysis, SEM, surface area, and IR-spectrum. As the results of the effects of pH, crosslink of synthetic resin, and dielectric constant of a solvent on uranium ion adsorption for resin adsorbent, the uranium ion showed high adsorption at pH 3 or over. Adsorption selectivity for the resin in methanol solvent was the order of uranium ($UO_2{^{2+}}$) > calcium ($Ca^{2+}$) > neodymium ($Nd^{3+}$) ion, adsorbability of the uranium ion was the crosslink in order of 1%, 2%, 5%, and 10% and it was increased with the lower dielectric constant.

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

- Aesthetic Restoration of the Gingival Recession with All-ceramic Partial Crown - (전치부 ALL-CERAMIC PARTIAL CROWN 의 임상)

  • Do, Hyang-Ju;Im, Ui-Bin;O, Ji-Yeon;Lee, Jong-Yeop
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.11-15
    • /
    • 2002
  • The black triangle is a common clinical finding in aged people with gingival recessions. Among other prosthetic treatment molalities such as composite resin filling and laminate venners, the all ceramic restoration procedure can lead to most successful result. With improved bonding strength and ceramic properties, the tooth preparation design for all-ceramic crown can be modified to minimize the reduction of sound tooth structure without loosing properties of conventional preparation design. Case selection is an important factor in acheiving succesful prosthesis. In this case report, the leucite reinforced pressable ceramic, $Authentic^{TM}$ [Ceramay, Germany] was used to fabricate the prosthesis.

  • PDF

A Study on the U(VI), Ca(II) and Lu(III) Metal Ions Utilizing Nitrogen-Donator Synthetic Resin (질소-주게 합성수지를 이용한 U(VI), Ca(II) 및 Lu(III) 금속 이온들에 관한 연구)

  • 정만태
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2000
  • The new ion exchange resin was synthesized from chloromethylated styrene-1,4-divinylbenzene(DVB) with 1-aza-15-crown-5 macrocyclic ligand by substitution reaction. The effect of pH, time, dielectric constant of solvent and cross-linked of the matrix on the adsorption for $UO_2^{2+}$, $Ca^{2}$ and $Lu^{3+}$ was investigated. The metal ion was not adsorbed on the resins below pH 3 but above pH 4 fast adsorption behavior was showed. The optimum equilibrium time for adsorption of metallic ions was two hours. The adsorption selectivity determined in ethanol matrix was in increasing order $UO_2^{2+}>Ca^{2}>Lu^{3+}$. The adsorption power was in the order of 1%, 2%, 10% and 20% -crosslinked resin, but adsorption properties of resins decreased in proportion to the order of dielectric constant of solvents used. In addition, these metal ions could be separated in the column packed with 1% crosslinked resin by pH2.5 $HNO_3$ as an eluent.

  • PDF

EFFECT OF TAPER AND SURFACE AREA OF INNER CROWN ON THE RETENTIVE FORCE OF ELECTROFORMED OUTER CROWN (전기성형술로 제작된 외관의 유지력에 내관의 축면경사도와 표면적이 미치는 영향)

  • Kang Wan-Keun;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.165-173
    • /
    • 2006
  • Purpose: With gold electroforming system fir the double crown, the secondary crown is electroformed directly onto the primary crown. An even thick layer of high precision can be acquired. It is thought that the retention of electroformed outer crown is primarily acquired by the adhesive force (surface tension) through the saliva which is interposed between precisely fitted inner and outer crown. The purpose of this study was to investigate the effect of taper and surface area of inner crown on the retentive force of electroformed outer crown according to the presence of saliva. Materials and methods: 32 titanium inner crowns with cervical diameter of 8 mm and cone angles of 0, 2, 4, 6 degrees, which had same surface area by regulated height, were machined on a lathe. Another 32 titanium inner crowns with cone angles of 0, 2, 4, 6 degrees, which had doubled surface area by increased cervical diameter. were fabricated. Eight specimens of each group, for a total of 64 titanium inner crowns, were prepared. The electroformed outer crowns were fabricated directly on the inner crowns by using electroforming machine(GAMMAT free, Gramm Technik, Germany). The tertiary frameworks were waxed-up on the electroformed outer crown and cast using nonprecious alloy($Rexillium^(R)III,\;Jeneric^(R)/Pentronh^(R)$ Inc., USA). The cast metal frameworks were sandblasted with alubimium oxides and cemented using resin cement(Superbond C&B, Sun Medical Co., Japan) over the electroformed copings of each specimen. Then, artificial saliva($Taliva^(R)$, Halim Pharm. Co., Korea) was sprayed between the inner and outer crown, and they were connected under 5 kg force. The retentive force was measured by the universal testing machine(Tinius Olsen 1000, Tinius Olsen, USA) with a cross-head speed of 66.67 mm/sec. The direction of cross-head travel was exactly aligned with the path of removal of the respective specimens. This measurement procedures for retentive force of electroformed outer crown with artificial saliva were repeated in the same way without presence of artificial saliva. Results and Conclusion: The following conclusions were drawn: 1. The retentive force of electroformed outer crown was decreased according to increased taper of inner crown(P<.05). 2. The retentive force of electroformed outer crown showed no significant differences according to surface area and the presence of artificial saliva(P>.05).

FULL COVERAGE RESTORATION OF PRIMARY ANTERIOR TEETH : A CASE REPORT (유전치의 전장피개수복 : 증례보고)

  • Hong, Kee-Sang;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.240-247
    • /
    • 1999
  • Primary anterior teeth requiring extensive restorative therapy due to caries, trauma or developmental defects can present a particularly challenging problem for the pediatric dentist. The ideal restorative technique would combine strength, durability esthetics and efficiency in placement. Couple these concerns with the technical difficulties of operating on children with behavior management problems, and the dentist is left with the difficult task of choosing from a variety of restorative options. Restorative modalities currently in use to treat primary anterior teeth include bonding with composite resin as in celluloid strip crowns, conventional stainless steel crowns, open-faced stainless steel crowns, commercially and chairside veneered stainless steel crowns and epoxy-coated stainless steel crowns. Each of these techniques presents technical, functional or esthetic compromises that complicate their efficient and effective usage. This is a report of the results obtained at the Department of Pediatric Dentistry, College of Dentistry Seoul National University, through the use of these various methods of treating primary anterior teeth.

  • PDF