• Title/Summary/Keyword: Resin casting

Search Result 106, Processing Time 0.026 seconds

Comparison of shearbond strength between metal and indirect resin according to the different conditionings (표면처리에 따른 금속과 간접복합레진간의 전단결합강도 비교연구)

  • Choi, Su-Young;Choi, Hyunmin;Moon, Hong-Seok;Shim, June-Sung;Park, Young-Bum;Lee, Geun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.264-271
    • /
    • 2017
  • Purpose: The purpose of this study is to investigate the differences in bond strength of four different indirect composites to the gold alloy and Ni-Cr alloy according to type of metal surface treatment after water storage. Materials and methods: Type IV gold alloy and Ni-Cr alloy were used for casting alloy while four types of indirect composite resins (Gradia, Tescera Sinfony and in;joy) were used in this study. Metal specimens were produced by casting and total of 240 specimens (60 specimens per one indirect composite group) were prepared. After bonding indirect composite resin and undergoing 24 hours of polymerization, customized jig was attached to the metal specimen and shear bond strength were measured using universal testing machine. Also, differences in shear bond strength before and after water storage for 240 hours were also measured. Results: In the measurement of shear bond strength according to the metal surface treatments, bead group showed high strength followed by loop and flatting group (P<.05). After being stored in water bath for 240 hours, Gradia showed statistically significant high bond strength compared to other indirect composite resins in all groups (P<.05). Conclusion: Shearbond strength was found to be different according to type of metal surface treatment and type of metal used after storage in water. Further studies need to be developed for clinical practices as three are still problems of microleakage, stain or wear.

Study on the reuse and recycling of the used foundry sands (폐주물사의 재활용 활성화 방안에 관한 연구)

  • Kim, Young-Jun;Chung, Myung-Hee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.4
    • /
    • pp.38-44
    • /
    • 2010
  • Foundry sands are made up of silica and some coking agents, such as bentonite or resin, and used as templates for the production of various casting products. Foundry sands, which are repeatedly used, were finally transformed into the waste materials by heat, losing their proper functions. The used foundry sands have been treated as general wastes according to the contents of coking agents used. Silica, however, can be recycled through the proper treatment due to its physical property not to changed by heat. In this study, we have identified and investigated at the occurrence, treatment and recycling status of the used foundry sands, as well as for the regime and inhibitory factors of the recycling of them in domestic and foreign cases.

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

Vascular Changes by the Ice and Ultrasound Thermal Therapy (온냉 물리치료시 나타나는 혈관변화에 관한 실험적 연구)

  • 박희경;홍정표
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.79-87
    • /
    • 1996
  • The purpose of this study was to assess the vascular changes after thermophysical therapies using ice pack and ultrasound, investgate the mechanism of peripheral vasodilation by sympathetic nerve, and to observe the effects of the ergotamine to the thermophysical therapy. The author had used 16 healthy rabbits which were divided into 2 groups : with and without administration of ergotamine. Experimental animals were sacrificed 5, 10, 20 minutes after experiment, and were examined with gross and stereoscope of resin casting blood vessel models. The results were as follows : 1. Vasodilation was not remarkably found in the group with administration of egrotamine after thermophysical therapy. 2. Vasodilation was remarkably found in the group without administration of ergotamine after thermophysical therapy. 3. Vasodilation was increased in the group without administration of ergotamine, but not remarkably found in the group with administration of ergotamine in lapse of time 4. Thermophysical therapy was most effective to arterioles. Our data suggest that the dilation of peripheral blood vessels from thermophysical therapy was controlled by sympathetic nerve, because the blood vessels did not changed after administration of ergotamines which was a sympathetic nerve blocker.

  • PDF

Structure and Properties of Polymer Infiltrated Alumina Thick film via Inkjet Printing Process (잉크젯 프린팅 공정에 의한 유전체 후막의 제조 및 특성)

  • Jang, Hun-Woo;Koo, Eun-Hae;Kim, Ji-Hoon;Kim, Hyo-Tae;Yoon, Young-Joon;Hwang, Hae-Jin;Kim, Jong-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.4
    • /
    • pp.297-302
    • /
    • 2009
  • We have successfully fabricated the alumina thick films using inkjet printing processes without a high temperature sintering process. Alumina suspension as dielectric ink was formulated by combining nano-sized alumina powders with an anionic polymer dispersant in formamide/water as co-solvent. The thickness of the printed alumina thick film was measured at around 5 um by field emission scanning electron microscope. The calculated packing density of 68.5 % from the printed alumina thick film was much higher than the same films fabricated by conventional casting or dip coating processes. Q factor of the dielectrics thick film infiltrated with cyanate ester resin was evaluated by impedance analyzer.

Reformation of Dielectric Property in interface between epoxy and Cu (Epoxy-Cu간 접촉면에서의 절연특성 개선)

  • 송재주;김성홍;정남성;황종선;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.9-12
    • /
    • 2000
  • Insulators for high-voltage and large-power should be endured mechanically the weight of mold bushing itself and the force of pushed from contact with circuit breaker and conductor. But dielectric breakdown could be occurred result from the external circumstances and internal factors such as chemical reaction, partial discharge, change of temperature and the relation of temperature-time in process of casting. Therefore, to get rid of external and internal factors of dielectric breakdown. Furthermore, to prevent the internal cracks, void, cavity which resulted from the contraction originated on the interface between copper and epoxy resin, formed semi-conductive layer with partially carbon painted on copper bar. The PD properties and the insulation qualities of epoxy molded insulators were improved by roles of cushions for the direction of diameter and natural sliding effects as like separated from conductor for the direction of length.

  • PDF

AN EXPERIMENTAL STUDY OF THE IRRADIATION EFFECTS ON THE MICROVASCULATURE OF THE RAT SUBMANDIBULAR GLAND (방사선 조사가 백서 악하선 미세혈관계에 미치는 영향에 관한 실험적 연구)

  • Choi Karp Shik;Choi Soon Chul;Park Tae won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.43-53
    • /
    • 1992
  • The purpose of this study was to investigate the effects of irradiation on the microvascular structure of the submandibular gland in rats. For this study, 110 male rats were singly irradiated with the dose of 10Gy or 20Gy to their neck region by 6MV X-irradiation and sacrificed on the 1st, 3rd, 7th, 14th and 28th day after irradiation. The author observed distribution and structural changes of the microvasculature in rat submandibular glands using a scanning electron microscope by forming vascular resin casting. The author observed ultrastructural changes of the endothelial cells using a transmission electron microscope, and also histologic changes using a light microscope at Hematoxylin and Eosin staining and PAS staining process. The results of the irradiation effects on the microvasculature in rat submandibular gland were as follows: By light microscopic examination, the dilation of small vessels were observed until the 7th day after irradiation. After then, the vascular constriction and decrease in number of small vessels were noticed. Changes were greater on 20Gy irradiated group than on lOGy irradiated group. The reaction to PAS staining at acinar cells was decreased just after irradiation, but gradually recovered with days. There was no specific difference between two irradiated groups. By scanning electron microscopic examination, general findings on the two irradiated groups were similar. The dilation of conduits and meandering were observed on the 3rd day after irradiation. Decrease of capillary density and blunt ended small vessels were appeared on the 7th day after irradiation. After that, findings of the tortuous and twisted vascular running and coarseness of capillary lumen were increased. Changes were greater on 20Gy irradiated group than on l0Gy irradiated group. By transmission electron microscopic examination, increase of the formation of cytoplasmic process was observed on the 3rd day after irradiation. After that, swelling of endothelial cell and bridge formation of cytoplasmic processes were also observed, but destruction of endothelial cell and loss of basement membrane were observed only on 20Gy irradiated group on the 28th day after irradiation.

  • PDF

THE EFFECT OF ABUTMENT MATERIALS AND SURFACE TREATMENT ON RUBBER BASE IMPRESSION (고무 인상채득시 지대치재료와 표면처리법의 영향)

  • Jeong Do-Jin;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.146-156
    • /
    • 2001
  • The purpose of this study was twofold. One was to evaluate the wettability of 4 elastomeric impression materials on tooth and different kinds of filling materials. The other was to identify the effect of topical surfactants sprayed on the surface of each impression. The elastomeric impression mate rials used in this experimental study were one polyether(Impregum F) and three polyvinyl siloxanes(Provil novo, Zerosil, Imprint). The abutments were prepared for 3/4 crown or onlay on the extracted human first molar. The filling materials used in this study for the duplication of prepared abutment were composite resin, amalgam, and casting metal. Impression was taken by manufacturer's recommendations and the number of voids on the impression surface was counted. The topical surfactants were Spannex $II^{(R)}$ and $Cohere^{(R)}$. The wettability was evaluated by comparing the number of voids between non-treated group and treated groups. The results were as follows : 1. $Zerosil^{(R)}$ showed the least number of voids on the impression surface. The number of voids increased in order of Provil $novo^{(R)}$, Impregum $F^{(R)}$, and $Imprint^{(R)}$. 2. Impregum $F^{(R)}$ and $Zerosil^{(R)}$ showed the least number of voids on the surface of dental stone master cast. The number is inclosed in order of Provil $novo^{(R)}$ and Imprint 3. When abutment material is tooth, the number of voids on the surface of master cast was smallest compared with that of other abutment materials. The number of voids increased in order of casting metal, amalgam and composite resin 4. The number of voids on the surface of the dental stone master cast was smallest when Spannex $II^{(R)}$ was used, followed by $Cohere^{(R)}$ treated group and non-treated group. These results suggest that the difference in wettability caused by the types of rubber base impression materials as well as abutment materials can affect the number of voids. And the use of topical surfactant for rubber base impression materials can improve the wettability of the materials and enhance the accurate master cast which has fewer surface voids.

  • PDF

Study on Effect of the printing direction and layer thickness for micro-fluidic chip fabrication via SLA 3D printing (적층 방식 3차원 프린팅에 의한 미세유로 칩 제작 공정에서 프린팅 방향 및 적층 두께의 영향에 관한 연구)

  • Jin, Jae-Ho;Kwon, Da-in;Oh, Jae-Hwan;Kang, Do-Hyun;Kim, Kwanoh;Yoon, Jae-Sung;Yoo, Yeong-Eun
    • Design & Manufacturing
    • /
    • v.16 no.3
    • /
    • pp.58-65
    • /
    • 2022
  • Micro-fluidic chip has been fabricated by lithography process on silicon or glass wafer, casting using PDMS, injection molding of thermoplastics or 3D printing, etc. Among these processes, 3D printing can fabricate micro-fluidic chip directly from the design without master or template for fluidic channel fabricated previously. Due to this direct printing, 3D printing provides very fast and economical method for prototyping micro-fluidic chip comparing to conventional fabrication process such as lithography, PDMS casting or injection molding. Although 3D printing is now used more extensively due to this fast and cheap process done automatically by single printing machine, there are some issues on accuracy or surface characteristics, etc. The accuracy of the shape and size of the micro-channel is limited by the resolution of the printing and printing direction or layering direction in case of SLM type of 3D printing using UV curable resin. In this study, the printing direction and thickness of each printing layer are investigated to see the effect on the size, shape and surface of the micro-channel. A set of micro-channels with different size was designed and arrayed orthogonal. Micro-fluidic chips are 3D printed in different directions to the micro-channel, orthogonal, parallel, or skewed. The shape of the cross-section of the micro-channel and the surface of the micro-channel are photographed using optical microscopy. From a series of experiments, an optimal printing direction and process conditions are investigated for 3D printing of micro-fluidic chip.

Preparation and Desalination Characteristics of Highly Durable Heterogeneous Cation-exchange Membrane Based on Polyvinylidene Fluoride (PVDF) by Casting Method for Electrodialysis (캐스팅법에 의한 전기투석용 고내구성 Polyvinylidene Fluoride (PVDF)계 양이온 불균질 이온교환막 제조 및 탈염특성)

  • Ko, Dae Young;Kim, In Sik;Hwang, Taek Sung
    • Membrane Journal
    • /
    • v.26 no.2
    • /
    • pp.97-107
    • /
    • 2016
  • This study was carried out to prepare a heterogeneous cation exchange membrane by mixing polyvinylidene fluoride (PVDF), commercial cation exchange resin and sulfonated poly(phenylene oxide)(SPPO) in order to propose an optimum condition for the preparation, and to compare its properties with commercial membrane. Study results show that the ion exchange capacity and electrical resistance were outstanding when the ratio of polymer matrix was less than 30% comparing between PVDF-IER, PVDF-SPPO and PVDF-SPPO-IER. The tensile strength was confirmed that seemed a hard look was five times greater compared to the commercial heterogeneous membrane, despite the weak durability of PVDF resin. Therefore, when chemical and mechanical properties are considered, the optimum mixing ratio between PVDF, IER and SPPO was 30 : 70, at which electric resistance was measured as $3{\sim}5{\Omega}{\cdot}cm^2$, ion exchange capacity as 0.6~1.0 meq/g, while mechanical strength was in a range of $12{\sim}15kgf/cm^2$.