• 제목/요약/키워드: Resin canal

검색결과 188건 처리시간 0.024초

열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구 (A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA)

  • 백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향 (EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE)

  • 이철환;조경모;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

PROFILE을 이용한 만곡 근관 형성시 근관의 형태에 관한 연구 (A STUDY ON THE SHAPE OF A CANAL PREPARED WITH PROFILES IN A CURVED CANAL)

  • 박한수;이민구;김종진;이종엽
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.633-638
    • /
    • 1999
  • The purpose of our study is to evaluate the ability of nickel-titanium(NiTi) files in maintaining the original curvature of a curved root canal during canal preparation. Curved canals on translucent resin blocks were prepared with Profiles and stainless steel files and they were placed at the platform which can reproduce the same position. The unprepared and prepared canal forms were accurately compared by double exposure technique of photography. The results were as follows : 1 NiTi files made a canal comparatively taper, but stainless steel files didn't make a canal taper, wicest at midportion and comparatively wide at a apical portion. 2. Canals preparations with no. 25 Profile.06 up to the working length were most excellent in taperness and in maintaining the original curvature. Canals prepared with no 30 Profile.06 up to the working length made a little outer transportation at a apical portion, but not severe. 3. Canal preparations with Profile GT were excellent in taperness and in maintaining the original curvature, but made more enlargement toward the inner side at the starting portion of the curvature. 4. Canal preparations with stainless steel files were not tapered and provided the largest transportation.

  • PDF

ProFile®, ProTaperTM 및 K3TM Ni-Ti 파일의 과기구 조작이 치근단공 변위에 미치는 영향 (A STUDY ON TRANSPORTATION OF APICAL FORAMEN AFTER OVERINSTRUMENTATION BY PROFILE® ;PROTAPERTM AND K3TM IN SIMULATED CANALS WITH DIFFERENT CURVATURES)

  • 양현;양인석;황윤찬;황인남;윤숙자;김원재;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제32권2호
    • /
    • pp.87-94
    • /
    • 2007
  • 본 연구는 ProFile, ProTaper 및 $K^3$를 이용하여 과잉 기구 조작에 의해 근관 성형 시 근관의 만곡형태와 Ni-Ti 파일의 종류에 따라 치근단공이 어떻게 변위 되는지를 비교 분석하고자 시행되었다. 본 실험에서는 레진모형근관으로 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다 근관성형 기구로는 $ProFile^{(R)},\;ProTaper^{TM},\;K^{3TM}$를 사용하였다. 총 60개의 레진모형근관을 사용하였으며, 사용된 레진모형근관 및 Ni-Ti 파일의 종류에 따라 10개씩 6개의 군으로 나누어 근관성형을 시행하였다. 근관 성형 전 후 이미지를 Image-analyzing microscope 100X를 이용하여 얻고 Photoshop 7.0 프로그램을 이용하여 중첩하였다. 이미지 분석 프로그램을 이용하여 근관 성형 전 후 치근단공의 중심으로부터의 직경 변화량과 면적을 측정한 결과 만곡된 근관의 성형시 치근단공이 주로 만곡의 외측으로 변위됨을 나타내며 ProFile이 ProTaper나 $K^3$보다 통계적으로 유의성이 있게 작은 변화량을 나타내어 근관성형시 바람직한 기구임을 시사한다.

모형레진 근관에서 엔진 구동용 니켈-타이타늄 파일의 경사도의 차이에 따른 근관성형력의 비교 (COMPARISON OF SHAPING ABILITY OF NICKEL-TITANIUM ROTARY FILES WITH DIFFERENT TAPER IN SIMULATED RESIN CANALS)

  • 금기연;임경란;정일영;이승종;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.78-84
    • /
    • 2000
  • The aim of this study was to compare shaping ability of nickel-titanium rotary files with different taper in simulated resin canals. The instruments used in this study were GT with .04 taper ProFile with ISO-sized tip, .04 taper ProFile with ISO-sized tip alone, and .02 taper Naviflex file and all canals were prepared by crown-down technique. A total of 30 composite images were made from pre- and post-canal scanned images using Scanjet 4C scanner and Corel photopaint 8.0 and then, prevalence of canal aberrations was measured. The amount of coronal substance the instruments removed was also calculated two-dimensionally on digitized images with the Brain C software to compare the relative enlarging efficiency. Finally, the prepared internal canal form was evaluated three-dimensionally with impression technique. The results were as follows; 1. The incidence of zipping in Naviflex group was significantly high compared to the other two groups(P<.05). 2. The amount of coronal substance the GT combined group removed was significantly larger than the other two groups(P<.05). 3. The GT combined group produced canals with good taper and flow. Under the conditionas of this study, the combined use of larger tapered nickel-titanium rotary files prepared simulated canals safely, efficiently and with good three-dimensional form.

  • PDF

근관내(根管內) 근관충전제(根管充塡劑)의 유입성(流入性)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE FLOW OF CANAL SEALER BY MEANS OF LENTULO)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제1권1호
    • /
    • pp.34-38
    • /
    • 1975
  • Artificial canals were prepared by means of engine reamer on the slab which was made of clear acrylic resin. The shape of this canal is similar to the natural canal, the size is almost same as Kerr File No. 70, and the length is about 20mm. Sealer, Zine oxide eugenol mixture was prepared as matched to spatula test. Lentulo filler was inserted as deep as middle portion and apical one-third portion of the canal and the dental engine was driven in the speed of 1,000 and 3,000 r.p.m. in 30 seconds and 60 seconds with feeding of the sealer. The author measured the excess flow of the canal sealer from Lentulo end. Following are the results obtained from this study. 1. Lentulo insertion at the middle portion 1,000 r.p.m. in 30 seconds case: 0.21mm Same as above in 60 seconds: 0.20mm 2. Lentulo insertion at apical-thirds. 1,000 r.p.m. in 30 seconds: 0.22mm. Same as above in 60 seconds: 0.20mm. 3. Lentulo insertion at middle portion. 3,000 r.p.m. in 30 seconds: 0.14mm Same as above in 60 seconds: 0.25mm. 4. Lentulo insertion at apical-thirds, 3,000 r.p.m. in 30 seconds: 0.11mm Same as above in 60 seconds: 0.27mm.

  • PDF

A study on the quantity of apical extrusion of debris according to early coronal flaring

  • Kim, Min-Kyung;Hwang, Ho-Keel
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.580-580
    • /
    • 2003
  • I. Objectives This study investigated the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. II. Materials and Methods Five groups of 9 endodontic resin model were instrumented using each different technique:hand instrumentation without early coronal flaring, hand instrumentation after early coronal flaring, and three nickel-titanium engine-driven instrumentations(Hero 642, Protaper, K3) after early coronal flaring.(omitted)

  • PDF

제 IV 형 근관에서 System B Plugger tip의 깊이에 따른 근관 충전 효과 (THE EFFECT OF CANAL OBTURATION ACCORDING TO THE DEPTH OF THE SYSTEM B PLUGGER TIP IN THE TYPE IV CANAL)

  • 최희원;김수미;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제33권6호
    • /
    • pp.518-525
    • /
    • 2008
  • 본 연구의 목적은 제 IV형 근관에서 Continuous Wave 가압법을 이용하여 충전할 때 System B Plugger tip의 깊이에 따른 근단부 밀폐효과를 평가하기 위함이다. 50개의 J형 만곡을 갖는 레진 블록에 부러진 F3 ProTaper 파일을 이용해 근관장에서 3mm 지점에 ledge를 형성한 후, F1 ProTaper Ni-Ti file을 이용해 레진 블록을 천공시켜 제 IV형 근관을 형성하고 System B Plugger tip의 깊이에 따라 3개의 실험군과 1개의 대조군으로 분류하였다. 제 IV형 근관의 거터퍼쳐와 실러의 길이는 확대경하에서 캘리퍼를 이용해 측정하였고 다음과 같은 결과를 얻었다. 1. 대조군의 설측 근관에서 거터퍼쳐와 실러 모두 관찰되지 않았다. 2. 3 mm군에서는 5 mm 또는 7 mm군에 비해 유의하게 많은 거터퍼쳐의 충전이 관찰되었다 (p<0.05). 3. 7 mm군에서는 유의하게 많은 빈 공간이 관찰되었다 (p<0.05).

근단부 성형 크기에 따른 다양한 전동 니켈티타늄 파일의 중심 변위율 및 만곡도 감소 비교 (Comparison of the centering ratio and canal curvature reduction according to the apical preparation size using various NiTi rotary instruments)

  • 곽상원;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제47권7호
    • /
    • pp.435-443
    • /
    • 2009
  • The purpose of this study was to compare the centering ratio and reduction of canal curvature according to the preparation sizes of #30, #40 and #50 using three rotary NiTi instruments which have different shaft tapers. Seventy-two simulated root canals in clear resin blocks (Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland) were divided as following 3 groups according to the file system; the 24 canal blocks prepared with each of ProTaper Universal system (Group P), LightSpeed eXtra system (Group L), and K3 (Group K). The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the centering ratio and reduction of canal curvature. Mean scores of each group were statistically analyzed using one-way ANOV A and Duncan's multiple range test for post-hoc comparison. The results were as followings: 1. Group L showed better centering ratio, followed by K and P. And all experimental groups generally showed increasing tendency of centering ratio as the apical size was increasing from #30 to #50, except at 1 mm level of group P where showed reducing tendency of centering ratio. The smaller the ratio, the better the instrument remained centered in the canal. 2. Group P showed more decrease of canal curvature at all apical shaping size (p < 0.05). Under the conditions of this study, the shaft design could affect the quality of canal shaping and the smooth taperless flexible (LightSpeed) shaft design was capable of preparing canals with good morphological characteristics in curved canals.

  • PDF

Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers

  • Tanomaru-Filho, Mario;Torres, Fernanda Ferrari Esteves;Pinto, Jader Camilo;Santos-Junior, Airton Oliveira;Tavares, Karina Ines Medina Carita;Guerreiro-Tanomaru, Juliane Maria
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Objectives: This study evaluated by using micro-computed tomography (micro-CT) the filling ability and sealer apical extrusion promoted by a new Sealer Injection System (SIS; Angelus) with side openings needle, in comparison with the conventional injection system, associated with a new ready-to-use calcium silicate-based sealer (Bio-C Sealer). Materials and Methods: Acrylic resin models containing a main curved artificial canal and 3 simulated lateral canals in apical, middle and cervical thirds were used. The main root canals were prepared using a rotary system up to size 35.05. The canals were filled with Bio-C sealer by using a single cone technique and the conventional delivery system or SIS. Samples were scanned in micro-CT. The percentage of voids throughout the entire extension of the main root canal and in each third of the lateral canals, besides the apical extrusion of the sealer was calculated. Data were submitted to t-test (p < 0.05). Results: There was no difference between both systems in the main root canals filling. Although the volume percentage of voids was similar in the apical and middle thirds of lateral canals, SIS had the greatest filling ability of the cervical third lateral canal. Moreover, the conventional system showed the highest apical extrusion of the sealer. Conclusions: The conventional and SIS obturation systems had an appropriate filling ability of the main root canal. SIS had the best filling of the cervical third of the lateral canals, besides lower sealer apical extrusion, suggesting its clinical indication.