AN EXPERIMENTAL STUDY ON THE FLOW OF CANAL SEALER BY MEANS OF LENTULO

근관내(根管內) 근관충전제(根管充塡劑)의 유입성(流入性)에 관(關)한 실험적(實驗的) 연구(硏究)

  • 이명종 (서울대학교 치과대학 보존학교실)
  • Published : 1975.11.15

Abstract

Artificial canals were prepared by means of engine reamer on the slab which was made of clear acrylic resin. The shape of this canal is similar to the natural canal, the size is almost same as Kerr File No. 70, and the length is about 20mm. Sealer, Zine oxide eugenol mixture was prepared as matched to spatula test. Lentulo filler was inserted as deep as middle portion and apical one-third portion of the canal and the dental engine was driven in the speed of 1,000 and 3,000 r.p.m. in 30 seconds and 60 seconds with feeding of the sealer. The author measured the excess flow of the canal sealer from Lentulo end. Following are the results obtained from this study. 1. Lentulo insertion at the middle portion 1,000 r.p.m. in 30 seconds case: 0.21mm Same as above in 60 seconds: 0.20mm 2. Lentulo insertion at apical-thirds. 1,000 r.p.m. in 30 seconds: 0.22mm. Same as above in 60 seconds: 0.20mm. 3. Lentulo insertion at middle portion. 3,000 r.p.m. in 30 seconds: 0.14mm Same as above in 60 seconds: 0.25mm. 4. Lentulo insertion at apical-thirds, 3,000 r.p.m. in 30 seconds: 0.11mm Same as above in 60 seconds: 0.27mm.

Keywords

Acknowledgement

Supported by : 서울대 치대