• 제목/요약/키워드: Residual water level

검색결과 163건 처리시간 0.023초

ASSESSMENT OF POSSIBILITY OF PRIMARY WATER STRESS CORROSION CRACKING OCCURRENCE BASED ON RESIDUAL STRESS ANALYSIS IN PRESSURIZER SAFETY NOZZLE OF NUCLEAR POWER PLANT

  • Lee, Kyoung-Soo;Kim, W.;Lee, Jeong-Geun
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.343-354
    • /
    • 2012
  • Primary water stress corrosion cracking (PWSCC) is a major safety concern in the nuclear power industry worldwide. PWSCC is known to initiate only in the condition in which sufficiently high tensile stress is applied to alloy 600 tube material or alloy 82/182 weld material in pressurized water reactor operating environments. However, it is still uncertain how much tensile stress is re-quired to generate PWSCC or what causes such high tensile stress. This study was performed to pre-dict the magnitude of weld residual stress and operating stress and compare it with previous experi-mental results for PWSCC initiation. For the study, a pressurizer safety nozzle was selected because it is reported to be vulnerable to PWSCC in overseas plants. The assessment was conducted by nu-merical analysis. Before performing stress analysis for plant conditions, a preliminary mock-up ana-lysis was done. The result of the preliminary analysis was validated by residual stress measurement in the mock-up. After verification of the analysis methodology, an analysis under plant conditions was conducted. The analysis results show that the stress level is not high enough to initiate PWSCC. If a plant is properly welded and operated, PWSCC is not likely to occur in the pressurizer safety nozzle.

서해 태안반도 북서 연안해역에서의 연안류 특성 (The Characteristics of Coastal Currents to the Northwest of the Taean Peninsula in the Yellow Sea)

  • 신홍렬
    • Ocean and Polar Research
    • /
    • 제27권4호
    • /
    • pp.433-441
    • /
    • 2005
  • To investigate the characteristics of tidal currents and water circulation in the coastal waters off the Taean Peninsula, tidal currents and sea levels were measured at the study area from 1998 to 2004. In the central waterway to the south of Changan Sand Ridge, mean speed of tidal currents and residual currents were 74.0cm/s, 17.8cm/s respectively; the dominant residual currents flowed northeastward, and the amplitudes of semi-diurnal components $(M_2,\;S_2)$ were larger than diurnal components $(O_1,\;K_1)$. The flood and ebb tidal currents were northeastward and southwestward, respectively, and each period was about 6 hours for them, which was consistent with the period of sea levels at the study area. In the coastal region near Hakampo, Taean, mean velocities of tidal currents and residual currents were 46.1cm/s, 30.8cm/s respectively, and the dominant residual currents flowed southwestward. The amplitudes of shallow water constituents $(M_4,\;MS_4)$ were relatively laige, which were weaker to the northeastern coastal region off Mineodo. The northeastward flow continued for about $2{\sim}3$ hours, while the southwestward flow continued for about $9{\sim}10$ hours near Hakampo during the tidal period. Tidal currents flowed northeastward in the central area of the waterway during the period from the Low Water Level (LWL) to the High Water Level (HWL). While the currents in the coastal region flowed northeastward for the first 3 hours after the LWL, southwestward counter-currents flowed between 3 and 6 hours after the LWL. During the period from the HWL to the LWL, the dominant currents flowed southwestward in the study area except to the northeastern coastal region off Mineodo. Along the shorelines, the counter-currents flowed northward between 4 and 6 hours after the HWL. It seems that the counter-currents near the coastal region are caused by the topography and the geography of the shorelines at the study area.

Simulation of Tidal Fields around a Huge Floating Marina using a Multi-level Method

  • BOO SUNG YOUN
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.114-119
    • /
    • 2004
  • Floating marina has been interests as an alternative to the facilities for recreational boats because of its cost effectivenes and less environmental conflicts. For tile present research, a square floating marina with a length of 400m and draft of 5m was used. This marina can be extended to 800m by putting anotjer one together. Tidal field around tile marina was simulated using a multi-level finite difference method. Tidal motion was assumed sinusoidal in a closed rectangular bay. Velocities and residual current were investigated for two cases of single marina and two marinas installed in tile bay. It was found that the horizontal velocity fields from the water surface to the structure bottom around tile marina were affected. In the marina basin, magnitude of velocity was reduced considerably but overall quality of water circulation was preserved even after two marina were installed.

  • PDF

Design Optimization of an Ozone Contactor Using Ozone Contactor Model (OCM) Software

  • Kim, Doo-Il;Lee, Chae-Young;Joe, Woo-Hyeun;Lee, Seock-Heon
    • Environmental Engineering Research
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 2009
  • Designing an ozone contactor is complicated because the residual ozone, log C. parvum inactivation, and bromate formation should be optimized with fluctuating water quality. OCM software was developed to assist a plant designer or an operator to fulfill the sophisticated optimization required in the design or operation of a new or an existing plant. In this article, numerical simulations were carried out using the OCM software for the design of a new ozone contactor under diverse design factors (i.e., three pHs, three temperatures, low and high dispersion numbers, and four and ten cells with complete mixing) with kinetic parameters obtained from the sand-filter effluent of a water treatment plant treating water from the Paldang impoundment. The results of the simulation suggested that a high residual ozone concentration at low pH and low temperature would be challenging, and PFR-like hydrodynamics could lower the residual ozone concentration. The inactivation of C. parvum oocysts increased at a lower pH. A lower dispersion number and more cell division increased the inactivation efficiency. Bromate was instantaneously formed during the initial ozonation stage. The effluent concentration was much lower than the regulatory levels imposed by the USEPA because of the low bromide level in raw water.

지하저수조의 수리적 거동과 수질변화 특성 평가 (Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir)

  • 이현동;배철호;김정현;황재운;홍성호
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.

광양지역 지하수위 변화를 고려한 시공성에 관한 연구 (Study on Constructibility considering Changes of Groundwater Level in Kwang Yang port)

  • 김병호;양태선;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1120-1125
    • /
    • 2006
  • Larger area will be constructed in a harbor land and container terminal which are constructed in reclaimed land using the dredged materials. Soil improvement work is to be carried out including constructibility, in which is monitoring devices, measuring frequency, installations etc. The ground water tables in the reclaimed area are affected by the several factors which are design reclamation level, consolidation settlement, remaining surcharge pressure and remaining excess pore water pressure. The plan wii be drawn up in which monitoring results for the ground water tables are capable to provide the reliable ground water table when designers and civil engineers construct the harbor structures considering constructibility.

  • PDF

공동주택 지하저수조의 수질변화 및 부식성 특성 (Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment)

  • 장준영;김주원;황유훈;김기팔;신현상;임병란
    • 한국물환경학회지
    • /
    • 제38권6호
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.

잔류염소 측정용 전기화학센서의 유효성 (Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement)

  • 김홍원;정남용
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

우포늪 수위 자료의 시계열 모형화 및 잔차 분석 (Modelling and Residual Analysis for Water Level Series of Upo Wetland)

  • 김경훈;한대건;김정욱;임종훈;이종소;김형수
    • 한국습지학회지
    • /
    • 제21권1호
    • /
    • pp.66-76
    • /
    • 2019
  • 기후변화로 인해 홍수나 가뭄과 같은 자연재난이 빈번하게 발생하고 있고, 이로 인한 피해 또한 커지고 있다. 습지는 이러한 피해를 저감하고 최소화하는데 중요한 역할을 하고 있는 것으로 알려져 있다. 특히, 자연재난으로 인한 피해 저감 뿐만 아니라 습지의 다양한 기능을 이해하기 위해서는 수위의 변동성을 분석할 필요가 있다. 따라서 본 연구에서는 경상남도 창녕군에 위치한 우포늪의 수위 자료에 적합한 시계열 모형을 도출하고 모형의 적절성을 확인하기 위해 잔차 분석을 수행하였다. 즉, ARIMA 모형을 구축하였고, 잔차 분석을 위해 기존의 비모수 통계기법, BDS 통계기법 및 CRH(Close Returns Histogram)를 통한 결과들을 비교 분석하였다. 특히, 본 연구에서는 시계열 모형의 잔차 분석을 위해 CRH의 적용 가능성을 제시하고자 하였다. 분석 결과, CRH는 정확한 무작위성 검정 결과를 도출하였을 뿐만 아니라 다른 방법들에 비해서 단순한 계산과정을 통해 쉽게 결과를 얻을 수 있었다. 따라서 시계열 모형의 잔차 분석을 위해 BDS 통계기법 뿐만 아니라 CRH를 이용한다면 보다 효과적인 분석을 할 수 있을 것으로 판단된다.

배수관망의 잔류염소 평활화를 위한 최적 재염소 처리 (Optimal Rechlorination for the Regulation of Chlorine Residuals in Water Distribution Systems)

  • 윤재흥;오정우;최영송
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.90-98
    • /
    • 1998
  • The optimal rechlorination in water distribution systems was investigated by incorporating optimization techniques into a numerical water quality model. For a hypothetical system that consists of 10 junctions including a storage tank and 12 links, the bulk ($k_b$) and pipe-wall ($k_w$) decay-rate constants of chlorine residual are assumed to be 2.0 1/day and 1.5 m/day, respectively. It was also assumed that the lower and upper limits of chlorine residual in the network are 0.2 mg/L and 0.6 mg/L. When the chlorine source is only the storage tank (without rechlorination), the high levels of chlorine residual appear near the storage tank to maintain the chlorine residuals above the lower limit over the junctions. On the other hand, the chlorine residuals in the network are distribute within the desirable range (0.2 - 0.6 mg/L) after the optimal rechlorination through five injection sites including the storage tank. In case of a real water distribution system that comprises 28 junctions including a clear well and 27 links, the bulk and pipe-wall decay-rate constants are 0.3 1/day and 0.2 m/day, respectively. Before rechlorination, the required chlorine residual at the clearwell is 5.1 mg/L to keep the chlorine residuals above the minimum level (0.6 mg/L) over the junctions. By the optimal rechlorination at five injection sites, the chlorine residuals are distributed within a desirable range of 0.6 mg/L through 2.0 mg/L, which can avoid the excess of chlorine residuals near the clear well. Consequently, total chlirine doses are decreased by 81% in the hypothetical distribution network and 69 % in the real distribution network for satisfying the minimum chlorine residuals.

  • PDF