• Title/Summary/Keyword: Residual gas

Search Result 574, Processing Time 0.033 seconds

Scheme on Environmental Risk Assessment and Management for Carbon Dioxide Sequestration in Sub-seabed Geological Structures in Korea (이산화탄소 해양 지중저장사업의 환경위해성평가관리 방안)

  • Choi, Tae-Seob;Lee, Jung-Suk;Lee, Kyu-Tae;Park, Young-Gyu;Hwang, Jin-Hwan;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2009
  • Carbon dioxide capture and storage (CCS) technology has been regarded as one of the most possible and practical option to reduce the emission of carbon dioxide ($CO_2$) and consequently to mitigate the climate change. Korean government also have started a 10-year R&D project on $CO_2$ storage in sea-bed geological structure including gas field and deep saline aquifer since 2005. Various relevant researches are carried out to cover the initial survey of suitable geological structure storage site, monitoring of the stored $CO_2$ behavior, basic design of $CO_2$ transport and storage process and the risk assessment and management related to $CO_2$ leakage from engineered and geological processes. Leakage of $CO_2$ to the marine environment can change the chemistry of seawater including the pH and carbonate composition and also influence adversely on the diverse living organisms in ecosystems. Recently, IMO (International Maritime Organization) have developed the risk assessment and management framework for the $CO_2$ sequestration in sub-seabed geological structures (CS-SSGS) and considered the sequestration as a waste management option to mitigate greenhouse gas emissions. This framework for CS-SSGS aims to provide generic guidance to the Contracting Parties to the London Convention and Protocol, in order to characterize the risks to the marine environment from CS-SSGS on a site-specific basis and also to collect the necessary information to develop a management strategy to address uncertainties and any residual risks. The environmental risk assessment (ERA) plan for $CO_2$ storage work should include site selection and characterization, exposure assessment with probable leak scenario, risk assessment from direct and in-direct impact to the living organisms and risk management strategy. Domestic trial of the $CO_2$ capture and sequestration in to the marine geologic formation also should be accomplished through risk management with specified ERA approaches based on the IMO framework. The risk assessment procedure for $CO_2$ marine storage should contain the following components; 1) prediction of leakage probabilities with the reliable leakage scenarios from both engineered and geological part, 2) understanding on physio-chemical fate of $CO_2$ in marine environment especially for the candidate sites, 3) exposure assessment methods for various receptors in marine environments, 4) database production on the toxic effect of $CO_2$ to the ecologically and economically important species, and finally 5) development of surveillance procedures on the environmental changes with adequate monitoring techniques.

  • PDF

Effect of Volatile Matter and Oxygen Concentration on Tar and Soot Yield Depending on Coal Type in a Laminar Flow Reactor (LFR에서 탄종에 따른 휘발분과 산소농도가 타르와 수트의 발생률에 미치는 영향)

  • Jeong, Tae Yong;Kim, Yong Gyun;Kim, Jin Ho;Lee, Byoung Hwa;Song, Ju Hun;Jeon, Chung Hwan
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1034-1042
    • /
    • 2012
  • This study was performed by using an LFR (laminar flow reactor), which can be used to carry out different types of research on coal. In this study, an LFR was used to analyze coal flames, tar and soot yields, and structures of chars for two coals depending on their volatile content. The results show that the volatile content and oxygen concentration have a significant effect on the length and width of the soot cloud and that the length and width of the cloud under combustion conditions are less than those under a pyrolysis atmosphere. At sampling heights until 50 mm, the tar and soot yields of Berau (sub-bituminous) coal, which contains a large amount of volatile matter, are less than those of Glencore A.P. (bituminous) coal because tar is oxidized by the intrinsic oxygen component of coal and by radicals such as OH-. On the other hand, at sampling heights above 50 mm, the tar and soot yields of Berau coal are higher than those of Glencore A.P. coal by reacted residual volatile matter, tar and light gas in char and flame. With above results, it is confirmed that the volatile matter content and the intrinsic oxygen component in a coal are significant parameters for length and width of the soot cloud and yields of the soot. In addition, the B.E.T. results and the images of samples (SEM) obtained from the particle separation system of the sampling probe support the above results pertaining to the yields; the results also confirm the pore development on the char surface caused by devolatilization.

Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD (만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계)

  • Lee, Chan-Ju;Lee, Jae-Ho;Song, Jae-Woo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 1999
  • Background : Maximal expiratory flow rate is determined by the size of airway, elastic recoil pressure and the collapsibility of airway in the lung. The obstruction of expiratory flow is one of the major functional impairments of emphysema, which represents COPD. Nevertheless, expiratory narrowing of upper airway may be recruited as a mechanism for minimizing airway collapse, and maintaining lung volume and hyperinflation by an endogenous positive end-expiratory pressure in patients with airflow obstruction. We investigated the physiologic role of trachea in respiration in emphysema. Method : We included 20 patients diagnosed as emphysema by radiologic and physiologic criteria from January to August in 1997 at Seoul Municipal Boramae Hospital. Chest roentgenogram, high resolution computed tomography(HRCT), and pulmonary function tests including arterial blood gas analysis and body plethysmography were taken from each patient. Cross-sectional area of trachea was measured according to the respiratory cycle on the level of aortic arch by HRCT and calibrated with body surface area. We compared this corrected area with such parameters of pulmonary function tests as $PaCO_2$, $PaO_2$, airway resistance, lung compliance and so on. Results : Expiratory cross-sectional area of trachea had significant correlation with $PaCO_2$ (r=-0.61, p<0.05), $PaO_2$ (r=0.6, p<0.05), and minute ventilation (r=0.73, p<0.05), but inspiratory cross-sectional area did not (r=-0.22, p>0.05 with $PaCO_2$, r=0.26, p>0.05 with $PaO_2$, and r=0.44, p>0.05 with minute ventilation). Minute ventilation had significant correlation with tidal volume (r=0.45, p<0.05), but it had no significant correlation with respiratory frequency (r=-0.31, p>0.05). Cross-sectional area of trachea had no significant correlation with other parameters of pulmonary function including $FEV_1$, FVC, $FEV_1$/FVC, peak expiratory flow, residual volume, diffusing capacity, airway resistance, and lung compliance, whether the area was expiratory or inspiratory. Conclusion : Cross-sectional area of trachea narrowed during expiration in emphysema, and its expiratory area had significant correlation with $PaCO_2$, $PaO_2$, and minute ventilation.

  • PDF

Monitoring of Uniconazole by GC-NPD (GC-NPD 동시분석법을 이용한 유니코나졸 잔류실태조사)

  • Kim, Eun-Jeung;Choi, Bu-Chuhl;Choi, Su-Jeong;Hong, Chae-Kyu;Kim, Eun-Hee;Choi, Chae-Man;Seo, Young-Ho;Hwang, Young-Sook;Jang, Mi-Ra;Hwang, In-Sook;Kim, Moo-Sang;Chae, Young-Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.378-381
    • /
    • 2012
  • The monitoring of the uniconazole residual pesticide for agricultural products was conducted by multiclass pesticide multiresidue methods. Samples were collected from June to November, 2011. Uniconazole pesticide was detected in 49 samples from a total of 3,939 samples. The amount of uniconazole pesticide ranged from 0.09 to 17.89 mg/kg in 49 samples. This method was described for the simultaneous determination of uniconazole by gas chromatography with a nitrogen phosphorus detector (GC-NPD) and mass spectrometry (MS). The limit of detection and quantification were 0.006 and 0.018 mg/kg GC-NPD, respectively. For an evaluation of the GC-NPD method, uniconazole spiked into gyeojachae at a level of 0.5, 5 mg/kg was determined. The recoveries of uniconazole by the GC-NPD method ranged from 83.4 to 101.4%. The results indicate that the method of simultaneous analysis is applicable to uniconazole analysis.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

Relationship of Compliance and Oxygen Transport in Experimental Acute Respiratory Failure during Positive End-Expiratory Pressure Ventilation (실험적 급성호흡부전에서 호기말양압에 의한 폐유순도와 산소운반의 변화 및 상관관계 - 호흡부전의 기전에 따른 차이 -)

  • Lee, Sang-Do;Yoon, Se-Jin;Lee, Bok-Hee;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 1993
  • Background: Positive end, expiratory pressure (PEEP) has become one of the standard therapies for adult respiratory distress syndrome (ARDS). Total static compliance has been proposed as a guide to determine the size of PEEP ('best PEEP') which is of unproven clinical benefit and remains controversial. Besides increasing functional residual capacity and thus improving oxygenation, PEEP stimulate prostacyclin secretion and was proposed for the treatment of acute pulmonary embolism. But little is known about the effect of PEEP on hemodynamic and gas exchange disturbances in acute pulmonary embolism. Methods: To study the validity of total static compliance as a predictor of 'best PEEP' in ARDS and acute pulmonary embolism, experimental ARDS was induced in mongrel dog with oleic acid and acute pulmonary embolism with autologous blood clot. Then hemodynamic and gas exchange parameters were measured with serial increment of PEEP. Results:In ARDS group, total static compliance and oxygen transport were maximal at 5 cm$H_2O$, and decreased thereafter (p<0.05). With increment of PEEP, arterial oxygen tension ($PaO_2$) and arterial carbon dioxide tension ($PaCO_2$) increased and cardiac output and physiological shunt decreased. In pulmonary embolism group, total static compliance, oxygen transport, physiological shunt and cardiac output decreased and $PaO_2$ and $PaCO_2$ increased with increment of PEEP (p<0.05). Comparing the change induced by increment of PEEP by 1 cm$H_2O$ in ARDS group with that in pulmonary embolism group, there was no significant difference between two groups except cardiac output which decreased more in pulmonary embolism group (p<0.05). In ARDS group, oxygen transport and total static compliance increased after PEEP application, and total static compliance was maximal at the PEEP level where oxygen transport was maximal. However in pulmonary embolism group, oxygen transport and total static compliance decreased after application of PEEP. There was significant correlation between change of total static compliance and change of oxygen transport in both groups. Conclusion: In both ARDS and acute pulmonary embolism, it can be concluded that total static compliance is useful as a predictor of 'best PEEP'.

  • PDF

The Monitoring on Plasticizers and Heavy Metals in Teabags (침출용 티백 포장재의 안전성에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Kang, Kil-Jin;Jeon, Dae-Hoon;Kim, Hyung-Il;Sung, Jun-Hyun;Choi, Hee-Jung;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • Nowadays the teabag is worldwide used for various products including green tea, tea, coffee, etc. since it is convenient for use. In case of outer packaging printed, however, there is a possibility that the plasticizers which is used for improvement in adhesiveness of printing ink may shift to inner tea bag. In this study, in order to monitor residual levels of plasticizers in teabags, we have established the simultaneous analysis method of 9 phthalates and 7 adipates plasticizers using gas chromatography (GC). These compounds were also confirmed using gas chromatography-mass spectrometry (GC-MSD). The recoveries of plasticizers analyzed by GC ranged from 82.7% to 104.6% with coefficient of variation of $0.6\sim2.7%$ and the correlation coefficients of each plasticizer was $0.9991\sim0.9999$. Therefore this simultaneous analysis method was showed excellent reproducibility and linearity. And limit of detection (LOD) and limit of quantitation (LOQ) on individual plasticizer were $0.1\sim3.5\;ppm\;and\;0.3\sim11.5\;ppm$ respectively. When 143 commercial products of teabag were monitored, no plasticizers analysed were detected in filter of teabag products. The migration into $95^{\circ}C$ water as food was also examined and the 16 plasticizers are not detected. In addition we carried out analysis of heavy metals, lead (Pb), cadmium (Cd), arsenic (As) and aluminum (Al) in teabag filters using ICP/AES. $Trace\sim23{\mu}g$ Pb per teabag and $0.6\sim1718{\mu}g$ Al per teabag were detected in materials of samples and Cd and As are detected less than LOQ (0.05 ppm). The migration levels of Pb and Al from teabag filter to $95^{\circ}C$ water were upto $11.5{\mu}g\;and\;20.8{\mu}g$ per teabag, respectively and Cd and As were not detected in exudate water of all samples. Collectively, these results suggest that there is no safety concern from using teabag filter.

A Study on Replay Experiments and Thermal Analysis for Autoignition Phenomenon of Shredded Waste Tires (폐타이어 분쇄물의 자연발화현상에 대한 재연실험 및 열분석에 관한 연구)

  • Koh, Jae Sun;Jang, Man Joon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • These days, spontaneous ignition phenomena by oxidizing heat frequently occur in the circumstances of processing and storing waste tires. Therefore, to examine the phenomena, in this work, this researcher conducted the tests of fires of fragmented waste tires (shredded tire), closely investigated components of the fire residual materials collected in the processing and storing place, and analyzed the temperature of the starting of the ignition, weight loss, and heat of reaction. For the study, this researcher conducted fire tests with fragmented waste tires in the range of 2.5 mm to 15 mm, whose heat could be easily accumulated, and performed heat analysis through DSC and TGA, DTA, DTG, and GC/MS to give scientific probability to the possibility of spontaneous ignition. According to the tests, at the 48-hour storage, rapid increase in temperature ($178^{\circ}C$), Graphite phenomenon, smoking were observed. And the result from the DTA and DTG analysis showed that at $166.15^{\circ}C$, the minimum weight loss occurred. And, the result from the test on the waste tire analysis material 1 (Unburnt) through DSC and TGA analysis revealed that at $180^{\circ}C$ or so, thermal decomposition started. As a result, the starting temperature of ignition was considered to be $160^{\circ}C$ to $180^{\circ}C$. And, at $305^{\circ}C$, 10 % of the initial weight of the material reduced, and at $416.12^{\circ}C$, 50 % of the intial weight of the material decreased. The result from the test on oxidation and self-reaction through GC/MS and DSC analysis presented that oxidized components like 1,3 cyclopentnadiene were detected a lot. But according to the result from the heat analysis test on standard materials and fragmented waste tires, their heat value was lower than the basis value so that self-reaction was not found. Therefore, to prevent spontaneous ignition by oxidizing heat of waste tires, it is necessary to convert the conventional process into Cryogenic Process that has no or few heat accumulation at the time of fragmentation. And the current storing method in which broken and fragmented materials are stored into large burlap bags (500 kg) should be changed to the method in which they are stored into small burlap bags in order to prevent heat accumulation.

Effect of Influent C/N Ratio and DO on Denitrification of Nitrate Polluted Groundwater in a Biofilter Process (Biofilter 공정에서 유입 C/N비와 DO가 지하수의 질산성 질소제거에 미치는 영향)

  • Lee, Moo-Jae;Park, Sang-Min;Park, Noh-Back;Jun, Hang-Bae;Kim, Kong-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.355-361
    • /
    • 2006
  • In this study, effects of influent C/N(COD/Nitrate) ratio and dissolved oxygen(DO) concentration on biological nitrate removal from groundwater were investigated in the fixed-type biofilter. Influent nitrate of 30 mg/L was removed completely by biological denitrification at the C/N ratio of 10 and 4.0, while residual nitrate of 5 mg/L occurred at the C/N ratio of 2.0, which resulted from deficiency of organic electron donor. Furthermore, nitrite was accumulated up to about 5 mg/L as the C/N ratio decreased to 2.0. Increase in DO concentration also inhibited denitrification activity at the relatively high C/N ratio of 5.0, which decreased the nitrate removal efficiency. Although the influent DO concentration was reduced as low as 0.3 mg/L using sodium sulfite($Na_2SO_3$), effluent nitrite was up to 3.6 mg/L. On the other hand, nitrate was completely removed without detection of nitrite at the DO concentration of 0.3 mg/L using nitrogen gas($N_2$) sparging. The organic matter for denitrification in biofilter were in the range from 3.0 to $3.5gSCOD/g{NO_3}^--N$, while utilized these values increased at the high DO concentration of 5.5 mg/L. In addition to the high DO concentration and the low influent C/N ratio, DO control by chemical such as sodium sulfite affected on biological denitrification, which resulted in the reduction of nitrate removal efficiency and nitrite build-up in a biofilter.

Recovery of Pulmonary Function according to the Operative Sites after General Anesthesia (전신마취를 이용한 수술에서 수술부위에 따른 폐기능의 회복)

  • Kim, Hyeon-Tae;Lee, Sang-Moo;Uh, Soo-Taek;Chung, Yeon-Tae;Kim, Yong-Hoon;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.250-258
    • /
    • 1993
  • Background: After general anesthesia, decrease of functional residual capacity and lung compliance, ventilation/perfusion imbalance, and transpulmonary shunting can provoke hypoxemia during postoperative periods. Diaphragmatic dysfunction may be the main cause of these physiological abnormalities. Thus, we evaluated the change of pulmonary function after general anesthesia according to the operative sites, which could suggest clinical course and critical period of respiratory care of postoperative patients. Method: Preoperative portable spirometric evaluation and arterial blood gas analysis were performed at sitting or most-sitting position just previous day of surgery. Pulmonary function tests were also as same condition from postoperative day 1 to day 5. Results: 1) For thoracic surgery, FEV1 and FVC were not recovered at day 5, but FEV1/FVC was not decreased. $PaCO_2$ was slightly elevated at postoperative one day. 2) After upper abdominal surgery, postoperative day 5 did not show the recovery of FEV1 and FVC, but mild hypoxemia was developed at postoperative day 1. 3) Pulmonary function was recovered as preoperative value at postoperative day 5 in lower abdominal operation, but mild hypoxemia was also noted at postoperative day 1. 4) Surgery of peripheral areas did not show significant pulmonary function change and hypoxemia and hypercapnia from postoperative day 1. Conclusion: Surgery involving diaphragm provoke significant postoperative pulmonary function change after day 5. For the operation of peripheral sites adequate respiratory care during operation and postoperative period within 24 hours could prevent patients from respiratory complication.

  • PDF