• Title/Summary/Keyword: Residual chlorine concentration

Search Result 98, Processing Time 0.023 seconds

CLPP of Biofilm in Free Chlorine Residual and Monochloramine (유리잔류염소와 모노클로라민에서의 생물막의 CLPP)

  • Lee Dong-Geun
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.147-151
    • /
    • 2005
  • The disinfection effect of free residual chlorine and monochloramine on biofilm communities were investigated by CLPP (community level physiology profile) using Biolog GN plates. Low concentration of disinfectant, $0.5\;mg/\iota$ free chlorine and $1.0\;mg/\iota$ monochloramine, stimulated the growth of bacteria rather than disinfection. Bacterial concentrations were decreased at more than $1.0\;mg/\iota$ of disinfectants. CLPP was different with the type and concentration of disinfectant and sampling time. Common and different carbon sources were actively used with similar bacterial concentration in free chlorine and monochloramine. This represents the differences of bacterial communities with tap water contact times and disinfectant.

Model development for chlorine generation using electrolysis (전기분해에 의한 잔류염소 생성 예측 모델 개발)

  • Sohn, Jinsik;Lee, Sunjae;Shin, Chorong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.331-337
    • /
    • 2009
  • Electrolysis produces hypochlorous acid by using a small quantity of NaCl as electrolyte. This process maximizes the stabilization of drinking water through the control of chlorine residual concentration. This study investigated free chlorine generation by an electrolytic method using $Ti/IrO_2$ and stainless steel. The generation of free chlorine was increased with increasing hydraulic retention time, voltage, chlorine ion concentration and the number of electrodes. However, the change of pH did not affect the generation of free chlorine. There was no significant difference on the behavior of chlorine concentration between electrolytic method and NaOCl injection. In this study, the concentration of free chlorine predicted model based on power functional model was developed various under conditions. Electrolysis free chlorine generation model can be effective tool in the estimation of free chlorine generation.

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

Analysis of Flow Field in the Circular Water Tank According to the Number of Baffles (원형 물탱크내의 격벽수에 따른 유동장 해석)

  • Kim, Jung-Hwan;Kang, Dong-Youl;Jung, Tae-Jun;Kim, Se-Young;Choi, Jong-Wook;Chu, Byeong-Gil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • The concentration of residual chlorine should be kept at over 0.1 mg/L in the circular water tank used in a water purification system. Generally, the concentration of residual chlorine depends on the structure and the volume of water tank, and also the water flow rate. To secure the diffusion time is important to the concentration of residual chlorine. For that reason, the baffles are installed in the circular water tank. In the present study, the variations of water and chlorine concentration were obtained with time using the numerical analysis. And also, the streamlines were shown according to the number of baffles. As a results, the vortex flow appeared between baffles, and the diffusion time of chlorine increased with the more number of baffles.

Studies on Chlorine Demand and Its Decay Kinetics in Chlorinated Sewage Effluents (하수의 염소 소독시 총잔류염소 감소 특성에 관한 연구)

  • Beck, Youngseog;Sohn, Jinsik
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.176-183
    • /
    • 2005
  • Chlorination of wastewater is recently practiced in Korea. While many researchers have studied the kinetics of aqueous chlorine(HOCl) with nitrogeneous compounds and other organic/inorganic contaminants in drinking water, the researches of wastewater chlorination are relatively few. The purpose of this study was to investigate the chlorine decay kinetics and parameters on wastewater chlorination. Chlorine decay rate increased with increasing initial chlorine concentration. The parameters affecting chlorine decay rate were different in each wastewater treatment plant. One of the most important parameters affecting chlorine decay was initial chlorine concentration, and other parameters such as $NH_3-N$, total coliform, $UV_{254}$ and Fe were also affected. The decay ratio of chlorine was decreased with increasing initial chlorine concentration, and the disinfection efficiency showed good correlation with the decay ratio.

The Seasonal Variation of Free Chlorine Residuals by Water Supply Distance in Daegu (대구 지역의 계절 변화에 따른 급수관내 잔류염소 농도 거동)

  • Lee, Tae-Gwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.363-369
    • /
    • 2005
  • This paper presents the integrated technique of water quality analysis and Geographic Information System(GIS) for assessing the variation of free chlorine residuals by water temperature and supply distance in Sangri water supply system in Daegu. GIS was utilized for mapping projectmap, extraction of a pipeline route, and supply distance. Free chlorine residual is analyzed every month for appraising the seasonal variation. As a result, free chlorine residuals are affected both water temperature and water supply distance, and it becomes worse as water temperature and water supply distance is increased. To maintain 0.4mg/l of free chlorine residual, initial dose concentration should be over 1.85mg/l in summer.

Development of an Optimal Operation Model of Residual Chlorine Concentration in Water Supply System (송·배수시스템의 최적 잔류염소농도 관리 모델 개발)

  • Kim, Kibum;Hyung, Jinseok;Seo, Jeewon;Shin, Hwisu;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.587-597
    • /
    • 2017
  • This study aimed to develop a method to optimize residual chlorine concentrations in the process of providing water supply. To this end, this study developed a model capable of optimizing the chlorine input into the clearwell in the purification plant and the optimal installation location of rechlorination facilities, and chlorine input. This study applied genetic algorithms finding the optimal point with appropriate residual chlorine concentrations and deriving a cost-optimal solution. The developed model was applied to SN purification plant supply area. As a result, it was possible to meet the target residual chlorine concentration with the minimum cost. Also, the optimal operation method in target area according to the water temperature and volume of supply was suggested. On the basis of the results, this study derived the most economical operational method of coping with water pollution in the process of providing water supply and satisfying the service level required by consumers in the aspects of cost effectiveness. It is considered possible to appropriately respond to increasing service level required by consumers in the future and to use the study results to establish an operational management plan in a short-term perspective.

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

Reaction coefficient assessment and rechlorination optimization for chlorine residual equalization in water distribution networks (상수도 잔류염소농도 균등화를 위한 반응계수 추정 및 염소 재투입 최적화)

  • Jeong, Gimoon;Kang, Doosun;Hwang, Taemun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1197-1210
    • /
    • 2022
  • Recently, users' complaints on drinking water quality are increasing according to emerging interest in the drinking water service issues such as pipe aging and various water quality accidents. In the case of drinking water quality complaints, not only the water pollution but also the inconvenience on the chlorine residual for disinfection are included, thus various efforts, such as rechlorination treatment, are being attempted in order to keep the chlorine concentration supplied evenly. In this research, for a more accurate water quality simulation of water distribution network, the water quality reaction coefficients were estimated, and an optimization method of chlorination/ rechlorination scheduling was proposed consideirng satisfaction of water quality standards and chlorine residual equalization. The proposed method was applied to a large-scale real water network, and various chlorination schemes were comparatively analyzed through the grid search algorithm and optimized based on the suitability and uniformity of supplied chlorine residual concentration.