• Title/Summary/Keyword: Residual cement

Search Result 104, Processing Time 0.023 seconds

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

The mechanical properties of Reactive Powder Concrete using Ternary Pozzolanic Materials exposed to high Temperature (3성분계 포졸란재를 이용한 반응성 분체 콘크리트(RPC)의 고온특성)

  • Janchivdorj, Khulgadai;So, Hyoung-Seok;Yi, Je-Bang;So, Seung-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.68-71
    • /
    • 2013
  • Reactive Powder Concrete (RPC) is an ultra high strength and high ductility cement-based composite material and has shown some promise as a new generation concrete in construction field. It is characterized by a silica fume-cement mixture with very low water-binder (w/b) ratio and very dense microstructure, which is formed using various powders such as cement, silica fume and very fine quartz sand (0.15~0.4mm) instead of ordinary coarse aggregate. However, the unit weight of cement in RPC is as high as 900~1,000 kg/㎥ due to the use of very fine sand instead of coarse aggregate, and a large volume of relatively expensive silica fume as a high reactivity pozzolan is also used, which is not produced in Korea and thus must be imported. Since the density of RPC has a heavy weight at 2.5~3.0 g/㎤. In this study, the modified RPC was made by the combination of ternary pozzolanic materials such as blast furnace slag and fly ash, silica fume in order to economically and practically feasible for Korea's situation. The fire resistance and structural behavior of the modified RPC exposed to high temperature were investigated.

  • PDF

A Study on the Fire Resistance Performance of Mortars Using Mesoporous Silica Nanoparticles(MSNs) and PVA Fibers (다공성 나노실리카 입자(MSNs)와 PVA섬유를 혼입한 모르타르의 내화성능에 관한 연구)

  • Cheonpyo Park;Jakyung Lee;Taehyung Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.51-61
    • /
    • 2023
  • In this study, in order to improve the fire resistance performance of structures in case of fire in buildings and structures, PVA fibers and the ZnO particles combined with mesoporous nano silica (MSNs) were mixed with cement mortar, and the specimen was exposed to a temperature range of 20~1100℃. Then the residual compressive strength and weight change rate were measured to determine whether the fire resistance performance changed. As a result of the study, it was found that mixing mesoporous nano silica and PVA fiber together did not contribute to improving the fire resistance performance of cement mortar. On the other hand, mixing 0.5% of mesoporous nano silica and 0.1 vol% of PVA fiber showed the best improvement test results, showing that it was advantageous for fire resistance performance.

Mechanical and Thermal Characteristics of Cement-Based Composite for Solar Thermal Energy Storage System (태양열 에너지 저장시스템 적용을 위한 시멘트 기반 복합재료의 역학 및 열적 특성)

  • Yang, In-Hwan;Kim, Kyoung-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.9-18
    • /
    • 2016
  • The thermal and mechanical properties of fiber-reinforced cement-based composite for solar thermal energy storage were investigated in this paper. The effect of the addition of different cement-based materials to Ordinary Portland cement on the thermal and mechanical characteristics of fiber-reinforced composite was investigated. Experiments were performed to measure mechanical properties including compressive strength before and after thermal cycling and split tensile strength, and to measure thermal properties including thermal conductivity and specific heat. Test results showed that the residual compressive strength of mixtures with OPC and slag was greatest among cement-based composite. Thermal conductivity of mixtures including graphite was greater than that of any other mixtures, indicating favor of graphite for improving thermal transfer in terms of charging and discharging in thermal energy storage system. The addition of CSA or zirconium increased specific heat of fiber-reinforced cement-based composite. Test results of this study could be actually used for the design of thermal energy storage system in concentrating solar power plants.

A technique for fabricating abutment replica with hot melt adhesive material to minimize residual cement in implant restoration: a case report (임플란트 보철 합착 시 잔여 시멘트 최소화를 위해 열가소성 접착제를 이용한 복제 지대주 제작 방법: 증례보고)

  • Seo, Chi-Won;Han, A-Reum;Seo, Jae-Min;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.240-245
    • /
    • 2016
  • Removal of excess cement is important to prevent biological complication in cementation of implant restoration with subgingival margin. It can be difficult to completely remove excess cement. Several techniques have been introduced to minimize excess cement using abutment replica. In this case report, a simple method for making abutment replica with hot melt adhesive material in dental office was described. This technique is simple and effective because it can be used for pre-fabricated or custom abutment without additional laboratory procedure. In addition, it can minimize excess cement after cementation of implant restoration.

Effect of Organic Admixture(Calcium Lignosulfonate) on the Early Hydration Process of Portland Cement(III) (시멘트 초기수화과정에 대한 유기혼화제의 영향(III))

  • 문정연;최상홀
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.1
    • /
    • pp.5-10
    • /
    • 1985
  • The effect of calcium lignosulfonate (CLS) on the early hydration characteristics for clinker minerals was investigated. In the presence of CLS and unsufficient gypsum The hydration of $C_3$A lowered CLS adsorption to form ettrin-gite and the residual CLS in the liquid phase accelerated the solubility of C4AF hydration. As the result unreacted $Fe^{3+}$ in the liquid phase would be precipitated gelatinously on $C_3$ hydrates and the hydration of $C_3$ could be retarded. But by addition of optimum gypsum into the cement with CLS the presence of $Fe^{3+}$ in the liquid phase were lowered and $C_3$ hydration would be normallized.

  • PDF

Screw and cement retained implant prosthesis rehabilitation of mandibular edentulous patients with severely absorbed ridge (치조제가 심하게 흡수된 하악 무치악환자의 나사-시멘트 유지형 임플란트 보철 수복증례)

  • Im, Joong-Jae
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.149-156
    • /
    • 2019
  • Purpose: Prosthodontics for edentulous patients is a treatment technique using implant, which has impactful results in retention and support effects. Methods: As a retention technique, SCRP (screw and cement retained implant prosthesis) has reported in many studies as a beneficial method for both patients and curers, which can reduce errors in process of making abutment and top implant. Results: Prosthesis manufacturing, as polymerization method of hardened resin teeth with thermoplastic resin, is helpful for patients with aesthetic and financial situations regarding residual ridge and interocclusal relationship, also indicates reliable results in both retention and care. Conclusion: Using SCRP technique, we notably obtained a clinical and aesthetic outcome from five implants in anterior tooth, which are half fixable and detachable implants on screw of implant abutment by the technicians at anytime.

Comparison and Evaluation of Chloride Penetration Resistance in Nuclear Power Plant Concrete with Different Water-to-Cement Ratios (물시멘트비가 다른 원전 콘크리트의 염화물 침투저항성 비교평가)

  • Son, Jeong Jin;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.315-316
    • /
    • 2023
  • In the present investigation, the chloride ion penetration resistance of nuclear power plant concrete with varying water-to-cement ratios was assessed. A comparative analysis was conducted on concretes that do not incorporate supplementary cementitious materials, such as fly ash, using permanently decommissioned nuclear structures as a reference. The objective is to employ this acquired data as a fundamental resource for the evaluation of the residual service life of nuclear power plant structures in subsequent studies.

  • PDF

Fire resistance and residual strength of reactive powder concrete Using metakaolin

  • Jang, Hongseok;Yi, Jebang;So, Seungyoung
    • Steel and Composite Structures
    • /
    • v.36 no.6
    • /
    • pp.657-669
    • /
    • 2020
  • This study investigates the fire resistance characteristics of reactive powder concrete according to changes in the cement content per unit area, mixing ratio of metakaolin (MK), and content of polypropylene fiber. A fire test was conducted, and the resulting residual strength characteristics were investigated through flexural and compressive strength measurements, as well as condition rating classification based on visual evaluation. MK effectively reduced the initial high content of calcium hydroxide, thereby reducing the water vapor pressure generated during pyrolysis and slowing spalling. Furthermore, the pore structure and loose tissue were effective for relieving the water vapor pressure in the event of a fire.

Geotechnical Engineering Characteristics of Mixed Soil Containing Stone Sludge (석분혼합토의 지반공학적 특성)

  • Kim, Chan-Kee;Kim, Joong-Chul;Park, Wook-Geun;Kim, Eui-Jo;Kim, Yong-Chul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1378-1382
    • /
    • 2009
  • This study is conducted to investigate the possibility of the utilization of the mixed soil formed by mixing stone sludge, bentonite, and residual soil as a soil sealant sustaining both stability and capacity in the barrier system. And the mixed soil formed by mixing stone sludge, river sand is conducted to investigate the possibility of recycle. A series of tests were performed on the mixed soil(stone sludge, bentonite, Cement and residual soil) to evaluate basic properties such as compaction, compressive strength, permeability of these materials. and the stone sludge-river sand mixed soil were performed the discharge capacity tests.

  • PDF