STRUCTURAL TEST AND ANALYSIS OF RC SLAB AFTER FIRE LOADING

  • Chung, Chul-Hun;Im, Cho Rong;Park, Jaegyun
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.223-236
    • /
    • 2013
  • In the present study the behavior of fire and the residual strength of fire-ignited RC slabs are investigated by experimental tests and numerical simulations. The fire tests of RC slabs were carried out in a furnace using the ISO 834 standard fire. The load capacity of the cooled RC slabs that were not loaded during the fire tests was evaluated by additional 3 point bending tests. The influence of the proportion of PP (polypropylene) fibers in the RC slabs on the structural behavior of the RC slabs after the fire loading was investigated. The results of the fire tests showed that the maximum temperature of concrete with PP fiber was lower than that of concrete without PP fiber. As the concrete was heated, the ultimate compressive strength decreased and the ultimate strain increased. The load-deflection relations of RC slabs after fire loading were compared by using existing stress-strain-temperature models. The comparison between the numerical analysis and the experimental tests showed that some numerical analyses were reliable and therefore, can be applied to evaluate the ultimate load of RC slabs after fire loading. The ultimate load capacity after cooling down the RC slabs without PP fiber showed a considerable reduction from that of the RC slabs with PP fiber.

Effects of Pefloxacin Grinding on Pharmacokinetic Parameter in Korean Rockfish (조피볼락에서 Pefloxacin의 미분쇄가 약물동력학 Parameters에 미치는 영향)

  • 임영근;양영환;김진우;손상규;심경희;김유정;정한영;최우식;야마모토케이지
    • Journal of Life Science
    • /
    • v.9 no.3
    • /
    • pp.241-247
    • /
    • 1999
  • Antibiotics have been routinely used to control the disease of farm-raised animals in the aquaculture facilities without any criterion based on a pharmacokinetic study. This lack of information on the effective usage of antibiotics would have brought the farmers to use excessive and/or less dosages, causing the advent of drug-resistant bacteria as well as economic loss and possible contamination of the local farming area. Until recently, few studies on a detailed manual for the antibiotic usage including chemotherapy procedure, dosage, and treatment schedule of the aquatic antibiotics have been conducted throughout the world. To the worse, there is no available criterion for optimal usage of aquatic antibiotics to control diseases in aquatic farms in this country because every country has its own aquacultural system. Therefore, based on the previous studies on the usage of the various antibiotics, our studies are to focus on the development of optimal method for the detection of various antibiotics on the fate of antibiotics applied to the fish, including absorption, circulation, and secretion physiology. Pharmacokinetic study were to sep up the optimal detective condition against residual antibiotics of fish by HPLC. The grinding pefloxacin for 15 min is most effective in dissolution test and pharmacokinetic parameters. Pharmacokinetic parameters were satisfactory for 15 min-grinding products and they can be explained as one-compartment model.

  • PDF

A study on the fracture behavior of mild steel plate evaluated in the light of Taylor's work hardening theory (Taylor의 加工硬化理論의 입장에서 評價한 軟鋼薄板材의 破壞擧動에 관한 硏究)

  • 손세원;김상철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1335-1342
    • /
    • 1988
  • In this paper, mechanical properties of mild steel plate which was pretreated by prestress and prestrain loading conditions were studied. The variation of the mechanical properties of the test materials is evaluated in the light of Taylor's work hardening theory. Through this experimental study, it is recognized that material showed unstable phenomena after cyclic loading and it will recover its stability after a certain period of time accompaning the increment of hardness and the yield strength of the material. Also, the strength of smooth specimen, the notch strength of notch specimen and propagation behavior of fatigue specimen which were subjected to prestress and prestrain reveal that the optimal conditions may occur in the first, the middle and the later half of stage II of Taylor's work hardening theory, respectively.

Fire Resistance of the Concrete Corresponding to the Various Fiber Contents and Heating Curves (섬유의 종류 및 온도가열곡선 변화에 따른 콘크리트의 내화특성)

  • Han, Cheon-Goo;Pei, Chang-Chun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.5
    • /
    • pp.101-107
    • /
    • 2008
  • This study investigated fundamental characters of the concrete according to various fiber types and contents and their properties of spatting resistance and residual compressive strength after fire test corresponding to ISO and RABT heating corves. The results were summarized as following. The Flowability was gradually declined as the increase of fiber contents, and it was the most favorable with nylon(NY) fibers. The decrease of air contents due to increasing fiber contents was in order by polypropylene(PP), polyvinyl alcohol(PVA) and NY fibers. The compressive strengths were over 40 MPa at 7 days and 50 MPa at 28 days. It was in order by PVA, PP and NY fibers. For the spatting properties, all specimens were prevented at ISO heating curve. In the other hand, the partial spatting at the surface occurred on the plain without fibers, but it was prevented over 0.10 % of PVA and 0.05 % of PP and NY fibers at the RABT heating curve.

Fabrication and Characterization of Reaction Sintered SiC Based Materials (반응소결 SiC 재료의 제조 및 특성)

  • Jin, Joon-Ok;Lee, Sang-Pill;Park, Yi-Hyun;Hwang, Huei-Jin;Yoon, Han-Ki;Kohyama, Akira
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.294-299
    • /
    • 2003
  • The efficiency of complex slurry preparation route for the development of high performance RS-SiCf/SiC composites has been investigated. The green bodies for RS-SiC and RS-SiCf/SiC composite materials prior to the infiltration of molten silicon were prepared with various C/SiC complex matrix slurries, which associated with both different sizes of starting SiC particles and blending ratios of starting SiC and carbon particles. The reinforcing materials in the composite system were uncoated and C coated Tyranno SA SiC fiber. The characterization of RS-SiC and RS-SiCf/SiC composite materials was examined by means of SEM, EDS and three point bending test. Based on the mechanical property-microstructure correlation, process optimization methodology is discussed.

  • PDF

Corrosion Resistance of Fe-Mn-Si-Ni-Cr-TiC Shape Memory Alloy for Reinforcement of Concrete (콘크리트 보강재용 Fe-Mn-Si-Ni-Cr-TiC계 형상기억합금의 내식성)

  • Joo, Jaehoon;Lee, Hyunjoon;Kim, Dohyoung;Lee, Wookjin;Lee, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.6
    • /
    • pp.364-370
    • /
    • 2019
  • Fe-Mn-Si-Ni-Cr-TiC alloys have a shape memory property, recovering initial shape by heating. With an aim to improve a durability and stability of building and infrastructure, this Fe-based shape memory alloy (FSMA) can be employed to reinforce concrete structure with creation of compressive residual stress. In this work, corrosion resistance of FSMA was compared with general rebar and S400 carbon steel to evaluate the stability in concrete environment. Potentiodynamic polarization test in de-ionized water, tap-water and 3.5 wt.% NaCl solution with variations of pH was used to compare the corrosion resistance. FSMA shows better corrosion resistance than rebar and S400 in tested solutions. However, Cl-containing solution is critical to significantly reduce the corrosion resistance of FSMA. Therefore, though FSMA can be a promising candidate to replace the rebar and S400 for the reinforcement of concrete structure, serious cautions are required in marine environments.

Analysis on the Mass Loss in Self-blast type $SF_6$ Gas Circuit Breaker (Self-blast형 $SF_6$ 가스 차단기의 노즐용삭 분석)

  • Jeong, Young-Woo;Bae, C.Y.;Ahn, H.S.;Choi, J.W.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1422-1423
    • /
    • 2006
  • In our study, the PTFE nozzle ablation in the high-voltage self-blast type $SF_6$ gas circuit breaker was investigated. The test circuit breaker has the structure that the pin electrode is moving and the pressure reservoir volume and the dimension is almost same as commercial 145kv 40kA circuit breaker for similar result in real circuit breaker. The variation of current and arcing time was the range of $36kA_{rms}$(symmetry) - $40kA_{rms}$(asymmetry) and 10-16 ms. From the measured data the tendecy of the mass loss of the nozzle to current load and arc energy was estimated. In this process, the distance from the arc to nozzle(PTFE) surface, area which was exposed to arc and stroke contour was considered. These results will be used to enhance the accuracy of the computational fluid dynamics analysis in circuit breaker and estimate the residual life time of a circuit breaker.

  • PDF

Precision orbit determination with SLR observations considering range bias estimation

  • Kim, Young-Rok;Park, Sang-Young;Park, Eun-Seo;Park, Jong-Uk;Jo, Jung-Hyun;Park, Jang-Hyun
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.27.5-28
    • /
    • 2010
  • The unexpected observation condition or insufficient measurement modeling can lead to uncertain measurement errors. The uncertain measurement error of orbit determination problem typically consists of noise, bias and drift. It must be removed by using a proper estimation process for better orbit accuracy. The estimation of noise and drift is not easy because of their random or unpredictable variation. On the other hand, bias is a constant difference between the mean of the measured values and the true value, so it can be simply removed. In this study, precision orbit determination with SLR observations considering range bias estimation is presented. The Yonsei Laser-ranging Precision Orbit Determination System (YLPODS) and SLR NP (Normal Point) observations of CHAMP satellite are used for this work. The SLR residual test is performed to estimate the range bias of each arc. The result shows that we can get better orbit accuracy through range bias estimation.

  • PDF

A Study on Evaluation of Complex Deterioration evaluation and Prediction of Residual Life through Concrete Core (콘크리트 코어 분석을 통한 복합열화 평가와 잔존수명 예측 연구)

  • Shim, Jaeyoung
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.332-339
    • /
    • 2017
  • In the case of aged structures, the information of the structure is often lost after the completion of construction, and there is a great difficulty in predicting the durability life of the structure due to the lack of information on concrete formulations. In this study, the durability of concrete specimens was evaluated by various field and indoor test methods based on the core specimens collected from the field, and the durability life of the concrete structures was predicted by using the FEM analysis technique.As a result, the neutralization rate coefficient was $5.38E-6(cm^2/day)$ and the rate of progress was low. And the possibility of complex deterioration due to carbonation and salting was found to be very low.

Study on Two Step Plasma Treatment for Electroless Cu Plating of Fluoropolymer (불소수지의 무전해 동도금을 위한 단계적 플라즈마 전처리법에 관한 연구)

  • Shin, Seung-Han;Han, Sung-Ho;Kim, Young-Seok
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.3
    • /
    • pp.118-125
    • /
    • 2005
  • Low temperature plasma treatment with different gases and rf powers were performed to improve the adhesion strength between polytetrafluoroethylene(PTFE) and electroless deposited copper. According to the research, $H_2$ plasma having hydrogen radical was more effective in surface polarity modification than $O_2$ plasma due to the defluorination reaction. However, surface roughness of PTFE was more increased with $O_2$ than $H_2$ plasma. PTFE treated with $120W-O_2$ plasma and $250w-H_2$ plasma, consecutively showed rougher surface than single step $250w-H_2$ plasma treated one and more hydrophilic than single step $120W-O_2$ plasma treated one. And it showed 5B tape test grade, which is better adhesion property than 1B or 3B obtained by single step plasma treatment. In addition, adhesion strength between PTFE and Cu deposit is also deeply affected by residual water on its interface.