• Title/Summary/Keyword: Residual Approach

Search Result 526, Processing Time 0.025 seconds

Self-Diagnosis of Damage in Carbon Fiber Reinforced Composites Using Electrical Residual Resistance Measurement (잉여 전기 저항 측정을 이용한 탄소 섬유 강화 복합재의 파손 측정)

  • Kang, Ji-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.323-330
    • /
    • 2009
  • The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in-situ damage detection and sensing in carbon fiber reinforced plastic(CFRP) composites. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. A quasi-isotropic panel was manufactured and electrical resistance was measured. Then three different sizes of holes were drilled at a chosen location. The panel was prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrodes. Vertical, horizontal, and diagonal pairs of electrodes were chosen and the resistance was measured. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.

The South Sea Circulation of Korea: Two-dimensional Barotrophic Model (한국 남해의 해수순환: 2차원 순압모델)

  • Chang, Kyung-Il;Park, Kyeong;Suk, Moon-Sik;Kim, Choong-Ki
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.257-266
    • /
    • 2000
  • A vertically-averaged, two-dimensional version of the Princeton Ocean Model has been applied to the South Sea to simulate the circulation driven by tides and inflows/outflows across open boundaries. To incorporate both forcing properly, a two-step modeling approach is adopted, in which the tidal circulation is first simulated by specifying the tides along the open boundaries, and then both the calculated tidal currents and the observed steady mean currents are prescribed across the open boundaries. Model results show that the steady, subtidal circulation of the South Sea is different from the residual circulation due to tidal rectification, and subtidal currents become locally as strong as tidal currents. The Cheju Current entering the model domain across the Cheju Strait flows eastward in general while shifting onshore or offshore areas following local isobaths. The Tsushima Current entering across the southern boundary reaches farther to the north in the eastern vicinity of Cheju-Do as compared to that entering across other parts of the southern boundary. The Tsushima Current turns to the east, merges with the Cheju Current, and both the Cheju and Tsushima Current exit to the East Sea through the western channel of the Korea Strait. An intensification of the outflow occurs over the deep trough adjacent to the Tsushima Island, which appears to be due to the formation of the frictional boundary layer in order to remove excess positive relative vorticity generated by an increase in the layer thickness. The circulation driven by both the tidal and inflows/outflows is different from that driven by each forcing separately in coastal areas, which implies that both forcings should be considered simultaneously in the simulation of more realistic coastal circulation.

  • PDF

Reliability Analysis of Caisson Type Quaywall (안벽구조물의 신뢰성 해석)

  • Yoon, Gil-Lim;Kim, Dong-Hywan;Kim, Hong-Yeon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.498-509
    • /
    • 2008
  • Reliability analyses of Level I, II and III for bearing capacity, overturning and sliding of quaywall are carried out to investigate their safety levels depending upon its failure modes, and sensitivity analyses of each design variable are performed to find their effects on safety levels of quaywall. Reliability indices was 1.416 for both level II and III for case study I, and with 2.201 and 1.880, respectively, for the case study II at the critical loading conditions. Thus we were able to know that Level II (FORM) approach is good enough to use in practical design. Generally, it was found that probabilities of failure of quaywall were higher for sliding and bearing capacity failure modes and lower for overturning failure mode. From sensitivity analyses, the most influential design variables to reliability index of quaywall were coefficient of friction, residual water pressure and resistance moment for the sliding, overturning and bearing capacity failure modes, respectively. Especially, the sensitivity of reliability index due to inertial force and dynamic water pressures, which include a large COV when earthquake occurs, did not change greatly.

VRS-based Precision Positioning using Civilian GPS Code Measurements (가상기준점 기반 코드신호를 이용한 정밀 측위)

  • Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • With the increase in the number of smartphone users, precise 3D positional information is required by various applications. The positioning accuracy using civilian single-frequency pseudoranges is at the level of 10 m or so, but most applications these days are asking for a sub-meter level Therefore, instead of an absolute positioning technique, the VRS-based differential approach is applied along with the correction of the double-differenced (DD) residual errors using FKP (Flachen-Korrektur-Parameter). The VRS (Virual Reference Station) is located close to the rover, and the measurements are generated by correcting the geometrical distance to those of the master reference station. Since the unmodeled errors are generally proportional to the length of the baselines, the correction parameters are estimated by fitting a plane to the DD pseudorange errors of the CORS network. The DD positioning accuracy using 24 hours of C/A code measurements provides the RMS errors of 37 cm, 28 cm for latitudinal and longitudinal direction, respectively, and 76 cm for height. The accuracy of the horizontal components is within ${\pm}0.5m$ for about 90% of total epochs, and in particular the biases are significantly decreased to the level of 2-3 cm due to the network-based error modeling. Consequently, it is possible to consistently achieve a sub-meter level accuracy from the single-frequency pseudoranges using the VRS and double-differenced error modeling.

Optimal Design Method of 1-Port Surge Protective Device Based on Zinc Oxide Varistor (선화아연바리스터 기반의 1-포트 서지보호장치의 최적 설계 기법)

  • Jeong, Tae-Hoon;Kim, Young-Sung;Park, Geun-Bo;Lee, Seung-IL
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.93-102
    • /
    • 2018
  • This paper reports a Surge Protective Device (SPD) that is used to protect an automatic metering interface (AMI) power supplies of communication equipment on a low-voltage distribution system from a lightning current. The surge protective device (SPD) can be classified as one-port SPDs and two-port SPDs with decoupling elements depending on the connection type. The protection of internal systems against the lightning current may require a systematic approach consisting of coordinated SPDs. To deal with this, the definition of a lightning protection zone (LPZ) was studied and interpreted through a theoretical review. Because the lightning current resulting from a lightning surge is considerably high, there is limited protection from one SPD; therefore, coordinated cascaded MOV-based SPDs are installed to solve this problem. Regarding the power grid mentioned in this paper, a class II SPD for the low-voltage distribution system installed on the border of LPZ1 and LPZ2, which establish a protection coordination with the Arrester (LA, SA) that corresponds to the LPZO installed on the MOF stage connected to one system were designed to protect various communication (control) equipment, including the automatic meter reading system inside the branch-type electric supply panel of a building, not the incoming side of one system. In addition, performance-related tests were done by a comparison with the existing method through testing, and the optimal design was achieved for the 1-port SPD that uses a series connection and can bleed load current without any decoupling element.

Study on Electro-optic Characteristics of the Optically Compensated Bend Liquid Crystal Display Using UV Curable Monomer (광경화성 단분자를 이용한 광학 보상 휨 액정 디스플레이의 전기광학 특성연구)

  • Lim, Young-Jin;Jeon, Eun-Jeong;Kwon, Dong-Won;Kim, Jeong-Hwan;Jeong, Kwang-Un;Lee, Myong-Hoon;Lee, Seung-Hee
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.496-500
    • /
    • 2009
  • Optically compensated bend liquid crystal display (OCB-LCD) has many application fields owing to its fast response time and wide viewing angle. However, in order to operate the OCB-LCD in bend state, this device needs quick transitions from the initial splay state to bend state. Unlike conventional approach using transient high voltage for the transition, the OCB-LCD with high surface tilt angle, which was achieved by polymerization of UV curable reactive mesogen monomer under certain voltage, was manufactured and the cell showed bend state initially. Electro-optic and electrical characteristics of the cell were analyzed. The cell shows a fast response time owing to high surface pretilt angle and very low residual DC less than 0.1 V although another polymer layer is formed above polymer alignment layers.

Development of A Component and Advanced Model for The Smart PR-CFT Connection Structure (스마트 반강접 (PR) 콘크리트 충전 강재 합성 (CFT) 접합 구조물에 대한 해석모델의 개발)

  • Seon, Woo-Hyun;Hu, Jong-Wan
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.4
    • /
    • pp.1-10
    • /
    • 2011
  • This study investigates the performance of composite (steel-concrete) frame structures through numerical experiments on individual connections. The innovative aspects of this research are in the use of connections between steel beams and concrete-filled tube (CFT)columns that utilize a combination of low-carbon steel and shape memory alloy (SMA) components. In these new connections, the intent is to utilize the recentering provided by super-elastic shape memory alloy tension bars to reduce building damage and residual drift after a major earthquake. The low-carbon steel components provide excellent energy dissipation. The analysis and design of these structures is complicated because the connections cannot be modeled as being simply pins or full fixity ones they are partial restraint (PR). A refined finite element (FE) model with sophisticated three dimensional (3D) solid elements was developed to conduct numerical experiments on PR-CFT joints to obtain the global behavior of the connection. Based on behavioral information obtained from these FE tests, simplified connection models were formulated by using joint elements with spring components. The behavior of entire frames under cyclic loads was conducted and compared with the monotonic behavior obtained from the 3D FE simulations. Good agreement was found between the simple and sophisticated models, verifying the robustness of the approach.

Retrospective Analysis of Neoadjuvant Chemotherapy for Breast Cancer in Turkish Patients

  • Duman, Berna Bozkurt;Afsar, Cigdem Usul;Gunaldi, Meral;Sahin, Berksoy;Kara, I. Oguz;Erkisi, Melek;Ercolak, Vehbi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.4119-4123
    • /
    • 2012
  • Background: Neoadjuvant systemic chemotherapy is the accepted approach for women with locally advanced breast cancer. Anthracycline- and taxane-based regimens have been extensively studied in clinical trials and consequently are widely used. In this study aimed to research the complete response (pCR) rates in different regimens for neoadjuvant setting and determine associated clinical and biological factors. Methods: This study included 63 patients diagnosed with breast carcinoma among 95 patients that had been treated with neoadjuvant chemotherapy between 2007 and 2010. TNM staging system was used for staging. The histologic response to neoadjuvant chemotherapy was characterized as a pCR when there was no evidence of residual invasive tumor in the breast or axillary lymph nodes. Biologic subclassification using estrogen receptor (ER), progesterone receptor (PR), HER2 were performed. Luminal A was defined as ER+, PR+, HER2-; Luminal B tumor was defined as ER+, PR-, HER2-; ER+, PR-, HER2+; ER-, PR+, HER2-; ER+, PR+, HER2+; HER2 like tumor ER-, PR+, HER2+; and triple negative tumor ER, PR, HER2 negative. Results: Patients median age was 54.14 (min-max: 30-75). Thirty-two patients (50.8%) were premenapousal and 31 (49.2%) were postmenapousal. Staging was performed postoperatively based on the pathology report and appropriated imaging modalities The TNM (tumor, lymph node, metastasis) system was used for clinical and pathological staging. Fifty-seven (90.5%) were invasive ductal carcinomas, 6 (9.5%) were other subtypes. Thirty nine (61.9%) were grade II and 24 (38.1%) were grade III. Seven (11.1%) patients were stage II and 56 (88.9) patients were stage III. The patients were classified for ER, PR receptor and HER2 positivity. Seventeen patients had complete response to chemotherapy. Forty patients (63.5%) were treated with dose dense regimen (cyclophosphamide 600 mg/m2 and doxorubicine 60 mg/m every two weeks than paclitaxel 175 mg/m2 every two weeks with filgrastim support) 40 patients (48%) were treated anthracycline and taxane containing regimens. Thirteen patients (76%) from 17 patients with pCR were treated with the dose dense regimen but without statistical significance (p=0.06). pCR was higher in HER2(-), ER(-), grade III, premenopausal patients. Conclusion: pCR rate was higher in the group that treated with dose dense regimen, which should thus be the selected regimen in neoadjuvant setting. Some other factors can predict pCR in Turkish patients, like grade, menopausal status, triple negativity, percentage of ER positivity, and HER2 expression.

Seasonal Monitoring of Residual Veterinary Antibiotics in Agricultural Soil, Surface Water and Sediment Adjacent to a Poultry Manure Composting Facility (계분 퇴비화 시설 인근 농경지 토양, 지표수 및 저질토의 계절별 잔류 항생물질 모니터링)

  • Lee, Sang-Soo;Kim, Sung-Chul;Kim, Kwon-Rae;Kwon, Oh-Kyung;Yang, Jae-E.;Ok, Yong-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.273-281
    • /
    • 2010
  • Concentration of antibiotics including a tetracycline group (TCs) of tetracycline (TC), chlortetracycline (CTC), and oxytetracycline (OTC), a sulfonamide group (SAs) of sulfamethoxazole (SMX), sulfathiazole (STZ), and sulfamethazine (SMT), an ionophore group (IPs) of lasalocid (LSL), monensin (MNS), and salinomycin (SLM), and a macrolide group (MLs) of tylosin (TYL) was determined from samples collected from the agricultural soil, stream water, and sediment. For the agricultural soil samples, the concentration of TCs had the highest value among all tested antibiotic's groups due to its high accumulation rate on the surface soils. The lower concentrations of SAs in the agricultural soils may be resulted from its lower usage and lower distribution coefficient (Kd) compared to TCs. The concentration of TCs in stream water was significantly increased through June to September. It would be likely due to soil loss during an intensive rainfall event and a reduction of water level after the monsoon season. A significant amount of TCs in the sediment was also detected due to its accumulation from runoff, which occurred by complexation of divalent cations, ion exchange, and hydrogen bonding among humic acid molecules. To ensure environmental or human safety, continuous monitoring of antibiotics residues in surrounding ecosystems and systematic approach to the occurrence mechanism of antibiotic resistant bacteria are required.

A Feasibility Study on Application of a Deep Convolutional Neural Network for Automatic Rock Type Classification (자동 암종 분류를 위한 딥러닝 영상처리 기법의 적용성 검토 연구)

  • Pham, Chuyen;Shin, Hyu-Soung
    • Tunnel and Underground Space
    • /
    • v.30 no.5
    • /
    • pp.462-472
    • /
    • 2020
  • Rock classification is fundamental discipline of exploring geological and geotechnical features in a site, which, however, may not be easy works because of high diversity of rock shape and color according to its origin, geological history and so on. With the great success of convolutional neural networks (CNN) in many different image-based classification tasks, there has been increasing interest in taking advantage of CNN to classify geological material. In this study, a feasibility of the deep CNN is investigated for automatically and accurately identifying rock types, focusing on the condition of various shapes and colors even in the same rock type. It can be further developed to a mobile application for assisting geologist in classifying rocks in fieldwork. The structure of CNN model used in this study is based on a deep residual neural network (ResNet), which is an ultra-deep CNN using in object detection and classification. The proposed CNN was trained on 10 typical rock types with an overall accuracy of 84% on the test set. The result demonstrates that the proposed approach is not only able to classify rock type using images, but also represents an improvement as taking highly diverse rock image dataset as input.