• 제목/요약/키워드: Residential power generation

검색결과 108건 처리시간 0.023초

BESS를 적용한 계통연계형 PV시스템의 운전특성에 관한 연구 (A Study on the Operating Characteristics for the Grid Interconnected PV System with BESS)

  • 이강연;정병호;조금배;백형래;정해덕
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.69-77
    • /
    • 2006
  • Photovoltaic is an attractive technology to remote power applications, because of its reliability, low maintenance, and zero fuel requirements. In this paper represents residential PV system based on BESS(battery energy storage system) for managing the electric power, a pattern of daily operation considering the load characteristics of the house, the generation characteristics of PV power, and utility power leveling. For apply to control algorithm, we consider the load on monthly power consumption trend and daily usage pattern. As for the control of the proposed system, to increase the conversion efficiency of the PV power, bidirectional converter is used for MPPT and SPWM inverter. An experimental system is implemented, and some experimental results are provided to demonstrate the effectiveness of the proposed system.

수용가용 전자전력저장시스템의 경제성 분석 (Economic Assessment of Customer Owned Battery Energy Storage System (BESS))

  • 최준호;김재철;홍종석;손학식;임태훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.180-183
    • /
    • 2000
  • The Battery Energy Storage System(BESS) has lots of advantages such as load levelling, quick response emergency power(spinning reserve), frequency and voltage control, improvement of reliability, and deferred generation and transmission construction. The economic feasibility requires justification from the customer side of meter to promoting the dissemination of BESS nationally. In this paper, we proposed the economic assessment model of customer owned Battery Energy Storage System(BESS) which is complemented and improved the existing model. The proposed model is applied to the typical customer type(light-industrial commercial, and residential) which are taken from the statistical analysis on the load profile survey of Korea Electric Power COmpany (KEPCO). The economic assessment performed for each customer type to justifying their economic feasibility of BESS installation from the economic measures such as payback period, overall benefits, ROI, and ROR. The results of this paper are useful to the customer investment decision making and the national energy policy & strategy.

  • PDF

가정용 리튬배터리 ESS를 고려한 태양광 발전 하이브리드 PCS 특성에 관한 연구 (A Study on Characteristic of Hybrid PCS for Solar Power Generation Considering on a Residential Lithium Battery ESS.)

  • 황락훈;나승권;최병상
    • 한국항행학회논문지
    • /
    • 제26권1호
    • /
    • pp.35-45
    • /
    • 2022
  • 본 논문에서는 PV 시스템에서 태양광 발전 시스템의 완전한 동작을 위해 DC-DC 벅-부스트 컨버터와 MPPT (Maximum Power Point Tracking)제어 시스템에 대한 완전한 동작 시스템에 대해 모델링하고 시뮬레이션을 수행하여 양호한 동작을 확인하고자 한다. 이를 위해 이중층 커패시터(EDLC:Electric double-layer capacitors )를 사용한 순간전압강하 보상장치가 개발되어 적용되고 있다. 따라서 태양광 발전의 ESS(Energy Storage System)를 고려한 PCS(Power Conditioning System)를 제안하여 부하평준화를 통한 전력의 안정적인 공급을 확인한다. 본 논문에서는 순간전압강하 보상장치(DVR :Dynamic Voltage Restorer)에 사용되는 전기 이중층 커패시터에 비해 동일 사이즈 대비 에너지 밀도가 높은 하이브리드 커패시터(hybrid capacitor)를 적용하는 연구를 하였고, 단상 3[kW] 계통 연계형 태양광 전력변환기를 제안하였다.

마이크로 가스터빈 열병합장치 성능특성 연구 (Study on the Performance Characteristics of Micro Gas Turbine (MGT) Co-generation System)

  • 허광범;김재훈
    • 한국소음진동공학회논문집
    • /
    • 제16권9호
    • /
    • pp.964-970
    • /
    • 2006
  • Micro gas turbine(MGT) has received attention recently as small-scale distributed power sources. With characteristics such as their small size, lightweight, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of ' applications, including residential and small-scale industrial use. It is very easier to start-up and stop the MGT system which is the friendly environmental power system has just below the 9ppm NOx emmission and good quality of noise level. The exhaust heat emitted by the MGT is in the form of about $300^{\circ}C$ clean exhaust gas. The exhaust gas is suitable for absorption chiller/heater system. 1 has researched performance characteristics of the 60 kW class MGT-absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated.

부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안 (Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems)

  • 이유정;김규호;이상근;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

A Four Leg Shunt Active Power Filter Predictive Fuzzy Logic Controller for Low-Voltage Unbalanced-Load Distribution Networks

  • Fahmy, A.M.;Abdelslam, Ahmed K.;Lotfy, Ahmed A.;Hamad, Mostafa;Kotb, Abdelsamee
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.573-587
    • /
    • 2018
  • Recently evolved power electronics' based domestic/residential appliances have begun to behave as single phase non-linear loads. Performing as voltage/current harmonic sources, those loads when connected to a three phase distribution network contaminate the line current with harmonics in addition to creating a neutral wire current increase. In this paper, an enhanced performance three phase four leg shunt active power filter (SAPF) controller is presented as a solution for this problem. The presented control strategy incorporates a hybrid predictive fuzzy-logic based technique. The predictive part is responsible for the SAPF compensating current generation while the DC-link voltage control is performed by a fuzzy logic technique. Simulations at various loading conditions are carried out to validate the effectiveness of the proposed technique. In addition, an experimental test rig is implemented for practical validation of the of the enhanced performance of the proposed technique.

SINGLE-PHASE CURRENT SOURCE INVERTER WITH PULSE AREA MODULATION SCHEME FOR SOLAR POWER CONDITIONER

  • Hirachi, K.;Matsumoto, K.;Ishitobi, M.;Ishibashi, M.;Nakaoka, M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.724-729
    • /
    • 1998
  • In general, a single-phase current-fed PWM inverter using IGBTs has some unique advantages for small scale distributed utility-interactive power supply system as compared with voltage-fed PWM inverter. In particular, this is more suitable and acceptable for a non-isolated type utility-interactive power conditioner, which is going to be widely used for residential solar photovoltaic (PV) power generation system in Japan. However, this current-fed PWM inverter has a significant disadvantage. The output current of this inverter includes large harmonic contents when the inductance of smoothing reactor in its DC side is not large enough to eliminate its current ripple components of this inverter. In order to overcome this problem, a new conceptual pulse area modulation scheme for this inverter is introduced in difference with conventional PWM strategy. This paper presents a new effective control implementation of this PV power conditioner which is able to reduce the harmonic component in the output current produced by the single-phase current-fed PWM inverter even when the ripple current in the smoothing DC reactor is relatively large. The operating principle of the proposed control strategy introdued for this inverter system is described, and its simulation results are evaluated and discussed herein.

  • PDF

전력수용가 정전비용 산출물 위한 설문조사 방법론에 관한 연구 (Research for the survey of method to serviced customer Interruption cost evaluation)

  • 박수만;김재철;문종필;배주천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.259-261
    • /
    • 2002
  • KEPCO(Korea Electric Power Corporation) has been management alone before some time. However through the electrical industry reorganization generation and KPX(Korea Power Exchange) were separated on 2001. A marketing and distribution part will be separated in the future. While many problem for appear in future. how to management for power system network is important. unfortunallity, electrical power industry is starting point right now. Thus, detail data is incomplete for this field and detail research for this field is required with distribution reorganazation. In this paper suggest for customer interruption cost compute method to establish a standard. The standard is need to security operation of power system network. The customer interruption cost compute method necessity of customer interruption cost compute method is minimizing process for total cost. As final total cost compute through the interruption cost compute, we can recognize investment point exactly. We cited foreign survey questions, because exactly matched survey questions for in the country circumstance is not exist. And process to survey performance suggest after modify for match in the country circumstance. Survey questions that suggested fer this paper are classified five categories. This paper suggests to detail survey questions and survey method before survey and suggest to how to customer interruption compute when survey data is ensured. Moreover this paper suggest to average interruption cost compute for residential customer using statistical method.

  • PDF

가정의 전기 수요를 고려한 태양전지-연료전지 하이브리드 에너지시스템의 경제성 평가 (Economical Feasibility Evaluation of Solar-Fuel Cells in Hybrid Energy System for Domestic Electricity Demands)

  • 이영;최용성;장우새;이경섭
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.117-122
    • /
    • 2010
  • The solar cells and fuel cells power are being encouraged to reduce the environmental pollution and combat the global warming. And the electric generation hybrid system is usually more reliable and less costly than the systems that use a single source of energy. HOMER provides a platform to design and simulate the power system and then to choose the optimization results. Based on the electricity demand conditions during a year, this paper simulates with the HOMER and performs the monthly average electrical production and the most feasible economical case includes the net present costs and the annualized costs of the hybrid system components.

가정용 연료전지 발전 시스템을 위한 계통연계형 인버터 (Utility Interactive Inverter for Residential Fuel Cell Power Generation System)

  • 배영상;정상민;유태식;최세완;김효성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.517-519
    • /
    • 2005
  • 본 논문에서는 연료전지를 이용한 가정용 발전 시스템의 계통 연계를 위한 새로운 단상 인버터 시스템을 제안한다. 제안한 방식에 의해 역률 1에 가까운 전원 품질로 독립 운전과 계통연계 운전이 가능하고 자동 모드 전환시 최소의 과도상태를 갖는다. 또한 제안한 인버터 제어기는 연산이 적고 구조가 간단하여 저가격의 고정소수점 DSP로 구현이 가능할 뿐 아니라 정상상태 오차가 거의 없고 양호한 과도상태 응답특성을 얻을 수 있다. 제안한 계통연계형 인버터의 제어기에 관하여 기술하고 모의실험 및 실험에 의하여 그 타당성을 입증한다.

  • PDF