• Title/Summary/Keyword: Resident's Living Noise

Search Result 7, Processing Time 0.019 seconds

Present Condition on Noise Level and Types Including Residents' Living Noise in Apartment Units (아파트의 내부 생활소음레벨 및 소음종류 실태)

  • Choi, Yoon-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.427-430
    • /
    • 2008
  • The present study is a preliminary research improving the dwelling quality of apartment house as a kind of multi-family housing. The purpose of the study is to find out the present condition on noise level and types including residents' living noise in apartment units. The method was field survey consisted of field measurements on equivalent noise level, observation on noise type, and interview on residents' responses. The results are as follows. 1) Averages of indoor noise levels of subject houses were measured as $43.9{\sim}62.2\;dB(A)_{Leq5min}$, the average of each house except one was higher than the permissible level, 45 dB(A). 2) The noise types observed were mostly residents' living noise and classified as 'water hammer', 'living equipment noise', 'noise by family', 'hood noise', and 'kitchen noise' in own unit, 'walking and talking noise in stairs and corridors', 'noise by neighborhood house', 'noise by the upper story' in building, and outdoor noise. 3) The residents show slightly non-positive responses at 'noise by the upper story', 'noise by neighborhood house', 'water hammer', and 'noise by family'. Therefore, it is required to plan for preventing deterioration of the sound environment quality by residents' living noise in own unit as well as by neighborhood houses.

  • PDF

A Study on the Residents' Attitudes and Adaptation Behavior of Indoor Noise in Apartment Houses (아파트 내부소음에 대한 거주자 태도 및 적응행위에 관한 연구)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.1
    • /
    • pp.85-96
    • /
    • 1989
  • The purpose of study was to survey the indoor noise of apartment houses, residents, attitudes and their adaptation behavior in order to offer the information helpful to apartment designers and residents, in their housing policy. Documentary research and questionnaire survey methods were used in this research. The sample was taken from 187 housewives living in apartments in Seoul. Data were analyzed with the SPSS program. The results were as follow : 1. It was found that apartment residents pointed out washing machine noise inside the home, piano and other musical instruments noise outside the home. 2. Piano and other musical instrument noise were heard at 3 to 6 pp.m. when residents heard the noise, and water supply and drainage noise in bathrooms were found most noisy. 3. Apartment residents were discontent with noise outside the home, and they displayed positive adaptation behavior at a reduced noise level. 4. Attitudes arising from indoor noise in apartment houses and human noise, water supply and drainage noise, doorway opening and closing noise were found to be significant in sampled apartment groups. 5. The youngest child's age was a significant variable on the residents' attitudes and adaptation behavior of indoor noise in apartment houses. 6. Between the resident' attitudes and adaptation behavior involving indoor noise in apartment houses. 6. Between the resident' attitueds and adaptation behavior involving indoor noise apartment houses, the more they became discontented, the more quickly they adapted in a postive manner.

  • PDF

Measurement and Control of Abnormal Sound for Refrigerator (냉장고의 이상소음에 관한 사례연구)

  • 주재만;김중래;이동현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.380-384
    • /
    • 2001
  • The household reftigerator's noise which is closely related with resident environment can hardly be evaluated its sound quality using the Korean Standards. Radiation characteristics of compressor noise consist of tonal noise in low frequency range and, or narrow band noise in high frequency range. In this study, measuring method for detecting the abnormal and low-level noise in high frequency band is presented, and control method for its reduction is proposed. After installing wall which is similar to living condition, we determined a major concerning frequency band of noise. It can be found the directivity of high frequency noise radiated from compressor by using experiment and analysis. According to isolation of noise transfer path, remarkable noise reduction is achieved.

  • PDF

Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus (대학주변 원룸형 다가구주택의 소음측정평가)

  • Choi, Yoon-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

A Study on the Evaluation and Characteristics of Architectural Facility-equipment Noise in Building (건축 설비기기 소음의 특성 및 평가에 관한 연구)

  • Byun, Woon-Seob;Choi, Dool;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.537-544
    • /
    • 2009
  • On account of the technological development, intelligent building is on increasing where the artificial regulation on indoor environment is possible, thence the concern about those facilities such as water-supply facility, water-heater and drainage facility has becomes higher. However, due to diversification and complicated system of the facility-equipments, the noise generating from such facility equipment is gradually becoming a problem, and since especially equipment noises arising at the machine room frequently infringe into the resident's pleasant living environment with the complex types of an air-borne sound and a structure-borne sound, it is becoming the civil complaint. On such viewpoint, this Study ever observed the characteristics of noise generating from various facility-equipments in the building, and intended to evaluate the facility-noises by use of the valuation index such as PSIL, N, NC, NR. As result of, the facilities noise which happens in the machine room makes normal conversation very difficult due to high sound pressure level. Based on such data, this study is willing to present it as an essential material for establishment an efficient measure against the facility-noises arising at machine room hereafter.

A Study on the Residential Stress and Inclination to Move (주거환경 스트레스와 주거이동 성향에 관한 연구)

  • 고경필
    • Journal of the Korean housing association
    • /
    • v.8 no.2
    • /
    • pp.71-84
    • /
    • 1997
  • The Purpose of this study is to estimate how inclination to move can be appeared by understanding the cognition of a resident on stress due to the residential environment. 240 housewives living in Chiniu were Questioned statistical analysis were used with factor analysis, F-test. Duncan's Multiple range analysis, stepwise regression analysis and stepwise discriminant analysis, The result were summarized as follows 1) The stress of residential environment were clissified by six factors indoor facility, educational environmental. indoor structure, air Pollution noise, traffic convenience. 2) The extent of a stress from residential environment was significantly different in the socio-demographic variable and housing-related variable. 3) The stress of residential environment were affected by the direction of house. 4) The variable discriminating inclination to move were the stress of residential environment(air Pollution). an educational level, the type of housing possession, residential Period and the size of house.

  • PDF

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.