• Title/Summary/Keyword: Reservoir type

Search Result 257, Processing Time 0.035 seconds

Effect of Non-Agricultural Facilities on Water Quality and Contamination in Rural Area (농촌용수 수질관리를 위한 비농업시설의 영향 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Kim, Yang-Bin;Woo, Nam-Chil;Nam, Kyoung-Phile;Lee, Jong-Min
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This study was objected to identify the effect on water quality and contamination by non-agricultural facilities in 'A' reservoir watershed located in OO city, Kyounggi-do, Korea. Ground- and stream water samples showed (Na+K)-Cl, Ca(Cl, SO$_4$) and Ca-Cl type in an illegally discharging area of sewage and a densely industrial area indicating water contamination. Stream water of an illegally discharging area of sewage had high COD, T-N and T-P. In this area, direct incoming of sewage into stream water was induced ground water system by well pumping, and it made a progress of ground water contaminations with those components. Groundwater of a densely industrial area showed high concentrations of T-N, NO$_3$N. From a nitrogen isotope analysis, stream water of an illegally discharging area of sewage has ${\delta}^{15}N-NO_3$values of 0.7%0 was strongly affected by nitrogen originated from agrochemicals, and a densely industrial area of 19.7%0 from septic system. Ground- and stream water of a livestock fanning area were contaminated with NH$_3$-N and Mn, which was affected by intensive livestock facilities. SAR-conductivity plot indicates the water does not pose either alkalinity or salinity hazard for irrigation. COD, T-N, T-P, NO$3$-N, NH$_3$N and Mn concentrations from contaminated areas were diminished by mixing with 'A' reservoir water. There were no water contaminations in silver towns, vacationlands around reservoir and golf links. Consequently, it should be made a plan of systematic managements for past and- present possible contaminants and sewage systems in preventing water contamination by non-agricultural facilities.

A Pressure Adjustment Protocol for Programmable Valves

  • Kim, Kyoung-Hun;Yeo, In-Seoung;Yi, Jin-Seok;Lee, Hyung-Jin;Yang, Ji-Ho;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.370-377
    • /
    • 2009
  • Objective : There is no definite adjustment protocol for patients shunted with programmable valves. Therefore, we attempted to find an appropriate method to adjust the valve, initial valve-opening pressure, adjustment scale, adjustment time interval, and final valve-opening pressure of a programmable valve. Methods : Seventy patients with hydrocephalus of various etiologies were shunted with programmable shunting devices (Micro Valve with $RICKHAM^{(R)}$ Reservoir). The most common initial diseases were subarachnoid hemorrhage (SAH) and head trauma. Sixty-six patients had a communicating type of hydrocephalus, and 4 had an obstructive type of hydrocephalus. Fifty-one patients had normal pressure-type hydrocephalus and 19 patients had high pressure-type hydrocephalus. We set the initial valve pressure to $10-30\;mmH_2O$, which is lower than the preoperative lumbar tapping pressure or the intraoperative ventricular tapping pressure, conducted brain computerized tomographic (CT) scans every 2 to 3 weeks, correlated results with clinical symptoms, and reset valve-opening pressures. Results : Initial valve-opening pressures varied from 30 to $180\;mmH_2O$ (mean, $102{\pm}27.5\;mmH_2O$). In high pressure-type hydrocephalus patients, we have set the initial valve-opening pressure from 100 to $180\;mmH_2O$. We decreased the valve-opening pressure $20-30\;mmH_2O$ at every 2- or 3-week interval, until hydrocephalus-related symptoms improved and the size of the ventricle was normalized. There were 154 adjustments in 81 operations (mean, 1.9 times). In 19 high pressure-type patients, final valve-opening pressures were $30-160\;mmH_2O$, and 16 (84%) patients' symptoms had nearly improved completely. However, in 51 normal pressure-type patients, only 31 (61%) had improved. Surprisingly, in 22 of the 31 normal pressure-type improved patients, final valve-opening pressures were $30\;mmH_2O$ (16 patients) and $40\;mmH_2O$ (6 patients). Furthermore, when final valve-opening pressures were adjusted to $30\;mmH_2O$, 14 patients symptom was improved just at the point. There were 18 (22%) major complications : 7 subdural hygroma, 6 shunt obstructions, and 5 shunt infections. Conclusion : In normal pressure-type hydrocephalus, most patients improved when the final valve-opening pressure was $30\;mmH_2O$. We suggest that all normal pressure-type hydrocephalus patients be shunted with programmable valves, and their initial valve-opening pressures set to $10-30\;mmH_2O$ below their preoperative cerebrospinal fluid (CSF) pressures. If final valve-opening pressures are lowered in 20 or $30\;mmH_2O$ scale at 2- or 3-week intervals, reaching a final pressure of $30\;mmH_2O$, we believe that there is a low risk of overdrainage syndromes.

A Study on Dementia Alzheimer's type published to chinese magazine (중의잡지(中醫雜誌)에 보고(報告)된 Alzheimer형(型) 치매에 대(對)한 고찰(考察))

  • Chae, Jong-gul;Lee, Sang-ryong
    • Journal of Haehwa Medicine
    • /
    • v.10 no.1
    • /
    • pp.453-469
    • /
    • 2001
  • This study attempted to analyze the contents of the research papers concerning the diagnosis and treatment of Alzheimer-type dementia presented in the magazine of Chinese Medicine published in China over the period between 1998 and 2000. As a result, the following conclusion was drawn: 1. The Chinese medical category of Alzheimer-type dementia includes amnesia, dementia, stupidity, depression symptom complex, insanity and the like and uses the as the criterion for diagnosis and treatment effect evaluation. 2. The clinical symptoms of Alzheimer-type dementia include lowered intelligence, deterioration of memory, understanding and judgemental power, retardation of the reaction, emotional changes, character changes, behavioral changes and the like and are divided into mild, medium and serious according to the degree of symptom. 3. From the perspective of Bon-Heo-Pyo-Shil(state of deficient vital essence and excessive pestilential vapor), the pattern of Byun-Sung(identification) is divided into deficiency symptom complex, excessive symptom complex and indiscernible fullness and emptiness. The deficiency symptom complex includes deficiency of the liver and kidney, deficiency of essence of the kidney, deficiency of the reservoir of marrow and the like. The excessive symptom complex includes internally blocked stagnant blood, blocking of the passageway due to turbid phlegm, blood stasis due to stagnation of chi, and the like. The indiscernible fullness and emptiness symptom complex includes the deficiency of essence of kidney, blocking of the passageway due to stagnant phlegm, blood stasis due to the deficiency of kidney, blood stasis due to the deficiency of heart and the like. 4. The therapeutics and' prescription of Alzheimer-type dementia include the following: Bo-Shin-Ik-Su-Tang for tonifying the kidney, replenishing the marrow and plugging the essence; Ki-Guk-Ji-Hwang-Hwan-Ga-mi for reinforcing the vital essence of the liver and kidney; Kwi-Bi-Tang-Hap-Yang-Shim-Tang for invigorating the functioning of the spleen and nourishing the heart; Hyel-Bu-Chuk-Eo-Tang-Ga-Mi for activating the blood and resolving the stagnancy of the blood; Bo-Yang-Hwan-Oh-Tang for replenishing chi, activating the blood and resolving the stagnancy of the blood; Beoh-Kwang-Mong-Sung-Tang for invigorating the functioning of the spleen, replenishing the kidney, resolving the phlegm and enlivening the brain; n-Dam-Tang-Ga-Mi for invigorating the functioning of the spleen, replenishing chi, and removing the phlegm and unclogging the passageway); Se-Shim-Tang-Ga-Mi for removing the stagnancy of the liver and resolving the phlegm; and the like. 5. The research papers on, the medication cases of Alzheimer-type dementia understand the pathology of Alzheimer-type dementia from a consistent perspective. They view the pathology of Alzheimer-type dementia as the disease of Bon-Heo-Pyo-Shil(state of deficient vital essence and excessive pestilential vapor) with the combination of the deficiency of essence of the kidney, the deficiency of the brain marrow, blood stasis and blocked phlegm and the like and recommend the prescription of using Bo and Sa simultaneously for treating Alzheimer-type dementia. 6. The research papers on the medication cases of Alzheimer-type dementia reported that the use of creative prescriptions such as Si-Sam-Hang-Ji-Tang, Ji-Yung-Tang, Ka-Mi-Yunh-Ji-Hwan, Ja-Sin-Hwal-Hyel-Tang, Kal-Chang-Ik-Ji-Tang, Ho-Su-Bok-Ji-Tang, Kun-Noe-Ok-Ji-Hap-Je and the like led to the average high efficacy of 85.5%.

  • PDF

An Experimental Analysis of Hydrate Production using Multi-Well, Plate-Type Cell Apparatus (다중공 평판형 셀기기에서 하이드레이트 생산실험 분석연구)

  • Bae, Jaeyu;Sung, Wonmo;Kwon, Sunil
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.304-309
    • /
    • 2007
  • In this study, the "Multi Well Plate-type cell Apparatus" was designed and setup for performing the producing experiments of methane hydrate by depressurization, heat stimulating methods. In order to characterizing the producing mechanism of hydrate through porous materials, the experiments for various producing methods have been conducted with the aid of the apparatus which has high permeability. In the experimental result of depressurization method, the pressure is temporarily increased unlikely conventional gas reservoir due to the sourcing effect of hydrate dissociation in the pore. Meanwhile, the temperature is decreased because of the endothermic reaction while hydrate is dissociated. In the experimental results of heat stimulating method, the dissociation in depressurization method is more slowly processed than that in thermal method, and hence, its gas production is lower. In the case of production right after heating, hydrate is dissociated only near injecting point and the permeability becomes greater at that area only. It infers that the more gas is produced during relatively earlier producing period. Since then, the hydrate is more slowly dissociated than the case of production after heating and soaking. This time, the performances of pressure and production obtained by thermal method have been analyzed in order to investigate the effect of soaking time on gas recovery. As a result, the gas recoveries in the case of 2 min and 4 min soaking are higher than case in 6 min soaking. This is reason that hydrate is reformed due to the decrease of temperature. It is expected that the experimental results obtained in this work may be more clearly explained by utilizing the lower permeable porous system with the greater hydrate saturation.

Electrical Resistivity Response Due to the Variation of Embankment Shape and Reservoir Level (제체형태와 수위에 따른 전기비저항 반응 연구)

  • Oh, Seok-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.214-220
    • /
    • 2008
  • The distortion effect of electrical response for two-dimensional (2-D) DC resistivity method was verified in terms of 2-D inversion result of synthetic data obtained by three-dimensional (3-D) modeling, which is frequently applied to assess the safety of center core-type fill dam structure. The distortion effect is due to 2-D interpretation for 3-D structure. By the modeling analysis, we found that the water level is correctly described in the resistivity section around the middle part rather than each end side of the embankment due to the 3-D terrain effect, when the material of the embankment is assumed as horizontally uniform. And when we set the slope of outer rock fill part as uniform. the sharper the slope of the center core is, the more similar the resistivity section reflects. On the other hand, when the slope of the rock fill is steep, the resistivity section shows the water level at lower position than the real one, and the 3-D distortion effect at the end side of the embankment was enhanced.

Study on the Characteristics of Food-borne Pathogens Isolated from Students' Mobile Phones in Busan (부산지역 중·고등학생 휴대전화에서 분리한 식중독균의 특성 연구 - 대장균, 황색포도상구균, 바실러스 세레우스를 중심으로 -)

  • Park, Sun-Hee;Park, Yeon-Kyoung;Hwang, In-Yeong;Park, Hye-Young;Sung, Gyung-Hye;Jo, Hyeon-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.4
    • /
    • pp.255-265
    • /
    • 2016
  • Objectives: Mobile phones have become one of the most essential accessories in daily life. However, they may act as reservoir of infectious pathogens if they are used without hygienic practices in their handling. Therefore, this study aimed to isolate food-borne pathogens from mobile phones and investigate the characteristics of toxin genes and antibiotic susceptibility patterns. Methods: A total of 146 mobile phones were collected from 83 middle- and 63 high-school students in Busan. The surfaces of the mobile phones were aseptically swabbed. Results: Among the food-borne pathogens, Staphylococcus aureus, Bacillus cereus and Escherichia coli were detected in 26 (17.8%), 20 (13.7%) and four (2.7%) samples, respectively. There were no statistically significant differences according to school level, gender or phone type. None of four E. coli strains had pathogenic toxic genes. All of the B. cereus strains carried at least three different toxin genes among the nine enterotoxin and emetic toxin genes. Three out of 20 B. cereus strains (15%) possessed emetic toxin genes, which are rarely detected in food-poisoning cases in Korea. Among the 26 strains of S. aureus, the detection rate of staphylococcal enterotoxin genes, toxic shock syndrome toxin (tsst) and factors essential for methicillin resistance (femA) were 84.6%, 7.7% and 100%, respectively. In the antibiotic susceptibility test, there was no methicillin-resistant S. aureus (MRSA) or vancomycin-resistant S. aureus (VRSA). Conclusion: The results show that students' mobile phones in Busan were contaminated by food-borne pathogens which carried various toxic genes. Therefore, regular phone disinfection and hand hygiene is important in order to reduce cross-contamination.

Simulation of the Reduction Effect of Soil Loss Using SWAT Model (SWAT 모형을 이용한 토양유실량 저감효과 모의)

  • Jeong, Jin-Kweon;Kim, Hwan-Gi
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.4
    • /
    • pp.243-253
    • /
    • 2008
  • The purpose of this study was to simulate the reduction effect of soil loss in the Yongdam reservoir watershed using SWAT model. To evaluate accuracy for flow and sediment yield of SWAT model, calibration was performed for the period from Jan. 2002 to Dec. 2003, and the verification for Jan. 2005 to Dec. 2005. The calibration and the verification were carried out using data observed at the Cheoncheon gaging station. The $R^2$ and EI values in terms of a flow were 0.8 and 0.78 respectively for calibration, whereas they for verification were 0.88 and 0.86 respectively. In terms of a sediment yield, they were 0.7 and 0.48 respectively for calibration, whereas for verification were 0.64 and 0.54 respectively. As a results from model simulation, annual mean soil loss rates in terms of forest, paddy and upland were 0.02 ton/ha/yr, 0.15 ton/ha/yr and 7.58 ton/ha/yr, respectively. The results show that the land use type of a upland has more significant impact on a total soil loss as well as a sediment yield than other types of land use. The sediment delivery ratio was determined to be about 0.35. In this study 2 land cover change scenarios for upland area were considered. These scenarios were used an input to SWAT model in order to evaluate their impact on soil loss and sediment delivery. The results show that a reduction of the upland area would reduce the soil loss and sediment yield.

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

A Study on Selection and Measures of the Apprehensive Areas of Soil Loss in the So-ok Stream Watershed (소옥천유역 토양유실 우심지역 선정 및 대책에 관한 연구)

  • Jeong, Dong-Hwan;Kim, Haejung;Lee, Young Joon;Hong, Sunhwa;Yoon, Johee;Choi, Heelak;Cho, Hong-Lae
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.617-629
    • /
    • 2012
  • This study aims to find out critical areas of a soil loss and propose feasible measures to reduce the water quality deterioration by a soil lose. As a study area, the So-ok stream catchment locating at the upper area of Daecheong Reservoir is selected and intensive field observation was carried out. RUSLE model is applied to assess the impact of the pollution migration by a soil ross from the critical areas during storms on the water quality of Chusori embayment. As results, total amount of the soil ross assessed against to the critical area on which major type of land use is a orchard for fruits is 54.3 ton/ha/yr and that of an abandoned mine site is about 200 ton/ha/year. In particular as effective measures, a plantation of an appropriate species of fruit trees and an application of ecologic restoration schemes are proposed against to the orchard and the abandoned mine site, respectively.

Return flow analysis of paddy field by water balance method (물수지분석 기법에 의한 논에서의 회귀율 조사분석)

  • 정상옥;손성호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.2
    • /
    • pp.59-68
    • /
    • 2001
  • A water balance analysis was performed for a paddy field neighboring the Dongchang stream, downstream of the Unmun reservoir, which is constructed for the urban water supply. Daily rainfall data were collected and irrigation water flow rate, drainage flow rate, evaportranspiration, infiltration, and piezometeric head were measured in the field. The flow rates were continuously observed by water level logger during the growing season. The evaportranspiration and the infiltration were measured by N-type depletion meter and cylindrical infiltrometer, respectively. PVC pipes with 12mm diameter were used for piezometric head measurement. Total Irrigation and drainage flows were 3,608mm and 1,170mm in 1999, and 3,971mm and 1,548mm in 2000, respectively. The mean and range of the daily infiltration rate were 4.4mm/d and 3.4mm/d to 5.5mm/d in 1999 and 5.1mm/d and 4.1mm/d to 6.5mm/d in 2000, respectively. The net ground water flow including the change of soil water storage was 2,855mm in 1999 and 2,540mm in 2000. The evapotranspiration was 458.3mm in 1999 and 553.5mm in 2000. The range of daily evapotranspiration rate was from 1.6 to 8.7mm/d. The return flow ratio was about 32% in 1999 and 39% in 2000 and three year average was 35% including previous study in 1997. The amount of irrigation water was much higher than design standards or references in this study, This was caused by the inadequate water management practice in the area where water was oversupplied on farmers’ request rather than following sound water management principles.

  • PDF