• 제목/요약/키워드: Reservoir pipeline valve system

검색결과 6건 처리시간 0.016초

주입 압력파의 웨이블릿 일관성 분석을 사용한 저수조-관로-밸브 시스템에서의 누수탐지모형 연구 (A scheme of leak detection model in a reservoir pipeline valve system using wavelet coherence analysis of injected pressure wave)

  • 고동원;이정섭;김진원;김상현
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.15-25
    • /
    • 2021
  • In this study, a method of leakage detection was proposed to locate leak position for a reservoir pipeline valve system using wavelet coherence analysis for an injected pressure wave. An unsteady flow analyzer handled nonlinear valve maneuver and corresponding experimental result were compared. Time series of pressure head were analyzed through wavelet coherence analysis both for no leak and leak conditions. The leak information can be obtained through either time domain reflectometry or the difference in wavelet coherence level, which provide predictions in terms of leak location. The reconstructed pressure signal facilitates the identification of leak presence comparing with existing wavelet coherence analysis.

원심펌프 관로계에 대한 임펄스 응답법 적용 연구 (Impulse response method for a centrifugal pump in pipeline systems)

  • 허지성;김현준;송용석;김상현
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.481-489
    • /
    • 2016
  • Method of characteristic(MOC) has been widely used as a transient analysis technique for pressurized pipeline systems. There are substantial studies using MOC for the water hammer triggered through instantaneous valve closures, pump stoppage and pump startup for pipelines systems equipped with a centrifugal pump. Considering restrictions of MOC associated with courant number condition for complicated pipeline systems, an impulse response method(IRM) was developed in the frequency domain. this study implements the impact of centrifugal pump using transfer function in frequency domain approach. Using pump performance curve and the affinity law, this study formulated transfer functions which relate complex pressure head at upstream of pump system to that of downstream location. Simulations of simple reservoir-pump-valve system using IRM with formulated transfer function were similar to those obtained through MOC.

복합 관수로에서 인버스 임피던스 확장연구 (Extended inverse impedance method for multiple branches or loops pipeline systems)

  • 고동원;김상현
    • 상하수도학회지
    • /
    • 제37권6호
    • /
    • pp.437-446
    • /
    • 2023
  • We propose a transient evaluation scheme using a pressure measurement in a complicate pipeline systems. Conservation of mass and momentum equations in time domain can be transformed into a pressure head and flowrate relationship between upstream and downstream point in frequency domain. The impedance formulations were derived to address measured pressure at downstream to evaluate of flowrate or pressure head at any point of system. Both branched pipeline element and looped pipeline element can be generally addressed in the platform of the basic reservoir pipeline valve system. The convolution of time domain response function with measured pressure head from a downstream point provides flowrate or pressure head response in any point of the designated pipeline system. The proposed method was validated through comparison between traditional method of characteristics and the proposed method in several hypothetical systems.

휴대용 압력파 발생장치를 사용한 단일관로에서의 누수탐지 연구 (Study of leak detection in a pipeline system using a portable pressure wave generator)

  • 고동원;이정섭;김진원;김상현
    • 상하수도학회지
    • /
    • 제34권2호
    • /
    • pp.139-147
    • /
    • 2020
  • This paper suggests a nonlinear pressure consideration scheme through an unsteady pipe network analyzer for leakage detection with a portable pressure wave generator. In order to evaluate the performance of a proposal scheme, linear input pattern has been simulated and experiments had been carried out under both no leakage and one leakage conditions in a reservoir-pipeline-valve system. This method using portable pressure wave generator showed that a leakage can be detected from a reflection where a leakage is originated through time domain analysis. Meaningful similarity in pressure response between nonlinear input pattern and experimental results were found both no leakage and a leakage conditions.

Case studies for solving the Saint-Venant equations using the method of characteristics: pipeline hydraulic transients and discharge propagation

  • Barros, Regina Mambeli;Filho, Geraldo Lucio Tiago;dos Santos, Ivan Felipe Silva;da Silva, Fernando das Gracas Braga
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권1호
    • /
    • pp.55-62
    • /
    • 2015
  • This study aims to present a hydraulic transitory study as MOC applications for solving the Saint-Venant equations in two case studies: 1) in a penstock of a small hydropower system as a simple pipeline in the case of valve-closure in the downstream boundary with a reservoir in the upstream boundary; and 2) for discharge propagation into a channel by velocity and depth of the flow channel along space evaluation. The proposed methodology by Chaudry [5] concerning the development of hydrodynamic models was used. The obtained results for first and second case study has been confirmed that MOC numerical approach is useful for several engineering purposes, including cases of hydraulic transients and discharge propagation in hydraulic systems.

원심펌프의 시동 및 정지에 따른 수격현상 (Waterhammer Caused by Startup and Stoppage of a Centrifugal Pump)

  • 김경엽;김점배
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.51-57
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity As the pressure waves are propagating between the pumping station and the distributing reservoir, the pressure inside the pipe drops to the liquid vapor pressure with the pipeline profile, at which time a vapor cavity forms, and finally the column separation occurs. If the pressure in the pipe is less than the atmospheric pressure, the pipe can be collapsed and destroyed after the water columns separated by the vapor cavity rejoin. During the reverse flow, the pressure is so abnormally increased at the pumping station that the accident of flooding may happen due to the failure of system. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations, in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.