• 제목/요약/키워드: Research Performance Evaluation

검색결과 5,513건 처리시간 0.032초

스팀터빈의 공력성능 평가를 위한 공기 상사실험 (Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine)

  • 임병준;이은석;이익형;김영상;권기범
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.73-79
    • /
    • 2003
  • The steam turbine efficiency is an important factor in power plant. Accurate evaluation of steam turbine performance is essential. However, it is not easy to evaluate the steam turbine performance due to its high temperature and high pressure circumstance. Therefore most steam turbine performance tests were conducted by air similarity test. This paper described a test program for air similarity test of steam turbine at Korea Aerospace Research Institute. A test facility has been designed and built to evaluate aerodynamic performance of turbines. The test facility consists of air supply system, single stage test section, power absorption system, instrumentation and auxiliary system. For evaluation of steam turbine performance, the test of single stage axial turbine air similarity performance was conducted and uncertainty analysis was performed.

  • PDF

EMP 차폐 콘크리트 개발 및 성능평가 방법에 관한 문헌 연구 (Literature Review on Material Development and Performance Evaluation Method for EMP Shielding Concrete)

  • 이웅종;이환;김영진
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.67-76
    • /
    • 2020
  • 본 연구는 고출력 전자기파(EMP)를 차폐할 수 있는 콘크리트의 개발 방향과 차폐성능 평가방법의 표준화에 필요한 기술의 개발 방향을 도출하기 위한 목적으로 수행되었다. 콘크리트와 같은 복합재료를 대상으로 한 EMP 차폐 메커니즘은 아직 규명되지 않았고, 콘크리트 재료의 EMP 차폐성능에 대한 검증 방법도 아직 표준화가 되어 있지 않아, 연구자간의 연구결과를 객관적으로 상호 비교분석하는데 어려움이 발생한다. EMP 차폐 콘크리트의 개발 방향은 금속 분야에서 널리 알려진 전자파 손실 메커니즘의 고찰로부터 도출하였다. 콘크리트의 EMP 차폐성능 검증을 위한 표준화 방향은 콘크리트의 전기적 성질과 그 동안 콘크리트를 대상으로 연구한 차폐성능 평가방법들의 고찰로부터 도출하였다. 연구 결과, EMP 차폐 콘크리트 개발은 전기 전도성을 부여한 콘크리트의 재료개발이 우선하여야 하며, EMP 차폐 콘크리트의 재료개발 과정 중에는 전자파 손실 메커니즘별로 구분한 시험방법을 적용하고, 개발 제품의 최종 품질검증에는 일반화된 차폐성능 평가법(MIL-STD 등)을 준용한 시험법을 적용하면, 유효성이 입증된 콘크리트 차폐재 개발 및 성능평가가 가능할 것으로 판단된다.

다단연소사이클 액체 로켓엔진의 압력제어에 대한 연구 (Pressure Control of Staged Combustion Liquid Rocket Engine)

  • 황창환;이광진;우성필;임지혁;전준수;이정호;유병일;한영민
    • 한국추진공학회지
    • /
    • 제22권4호
    • /
    • pp.18-23
    • /
    • 2018
  • 나로우주센터에 구축/개발된 3단 엔진 연소시험설비에서 다단연소사이클 액체 로켓엔진의 시험을 수행하였다. 수류시험과 점화시험, 연소시험이 이루어졌으며 예연소기의 연소압력 제어를 위한 TTR의 개도를 $143^{\circ}$에서 $185^{\circ}$까지 변화시키며 시험을 수행하였다. 시험 결과 엔진의 주요성능과 TTR 개도에 의한 수력학적 변화를 확인하였지만 연소압력의 제어성 확인을 위한 결과는 얻지 못하였다. 향후 본 논문의 연구에서 도출된 개선점을 보완한 예연소기 압력제어 연구가 이루어질 것이다.

TWSTFT 모뎀의 성능평가방안 및 성능분석 (Study on a Method for Performance Evaluation and Analysis of TWSTFT Modems)

  • 이주현;오주익;이준효;최경원;이종구;양성훈;허윤정;유대혁;허명선;이영규
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제13권3호
    • /
    • pp.355-363
    • /
    • 2024
  • Time synchronization is crucial for ensuring the reliable operation of modern economic and social infrastructures. Techniques such as Global Navigation Satellite System (GNSS)-based methods and Two-Way Satellite Time and Frequency Transfer (TWSTFT) play key roles in precise time comparison and synchronization. TWSTFT, in particular, is recognized for its ability to achieve sub-nanosecond accuracy in time transfer, making it indispensable in fields such as satellite navigation. This paper proposes a comprehensive performance evaluation method for TWSTFT modems, emphasizing pre-validation in controlled environments to mitigate operational challenges. Using the proposed evaluation method, the study presents the standard deviation of RTT according to C/N0 and compares it with the datasheet of a commercial TWSTFT modem. Through this approach, the aim of this study is to enhance the reliability and accuracy of TWSTFT-based time synchronization across diverse applications.

출연연구기관 기관평가의 책임성 요소 변화 분석 (Accountability Trend for Government Supported Research Institutes : Evidence from the Institute Evaluation 1991-2005)

  • 이민형
    • 기술혁신학회지
    • /
    • 제10권3호
    • /
    • pp.580-603
    • /
    • 2007
  • 본 연구는 출연연구기관의 기관평가요소 분석을 통해 최근까지 출연연구기관에 대한 책임성(accountability)이 어떻게 변화 및 발전되어 왔는가를 분석하고자 한다. 구체적으로 1991년부터 2005까지 기관평가요소를 연구회 설립 이전과 연구회 설립 이후 기간으로 구분하여 분석하였다. 출연연구기관에 요구되는 책임성을 법규준수 책임성, 관리적 책임성, 재무적 책임성, 사업성과 책임성, 사회적 책임성 등 다섯 가지 책임성으로 구분하여 분석한 결과, 연구회 설립이전에는 법규준수 책임성, 관리적 책임성 등이 강조되었으며, 연구회 설립 이후에는 사업성과 책임성, 관리적 책임성이 강조되었다. 법규준수 책임성과 관리적 책임성은 시간이 흐름에 따라 요구하는 구체적인 책임내용이 상당히 변화되었다. 최근에는 사업성과 책임성이 가장 중요한 책임성으로 강조되고 있으며 재무적 책임성도 연구회 설립 이후 새롭게 등장하였다.

  • PDF

태양열 온수기 실증연구를 통한 성능 평가 (Performance Evaluation of Solar Water Heating System Using Proof Test)

  • 김재열;곽이구;양동조;최철준;김홍건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

엘리베이터 설치 작업용 시스템 비계의 구조 성능 평가 (Structural Performance Evaluation of System Scaffolding for Elevator Installation Work)

  • 황종문;이기열
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.61-68
    • /
    • 2023
  • This study performed a structural performance evaluation of a system scaffolding for elevator installation work developed in previous studies. The structural performance was evaluated via a structural test conducted to apply the working load specified in the design standard. The deflection of the horizontal member and the stress of each member constituting the system scaffolding were measured. Consequently, the structural safety evaluation including structural behavior and required performance was performed using the deflection and stresses measured from the structural test. The structural test and safety evaluation results based on the heavy working load corresponding to the design load indicated that the deflection, which is the performance criterion of the horizontal member, did not exceed the allowable value. Further, each member's stress, which is a safety evaluation indicator, did not exceed the allowable strength for both horizontal and vertical members with bending behavior and fordable bracing with tensile behavior, while also satisfying the required safety factor. In addition, the results confirmed the safety against deformation, partial damage, and destruction owing to excessive and maximum load. Therefore, the system scaffolding developed in this study satisfies both the structural performance and safety required by the design standards; thus, it can be applied to elevator installation work sites.

AHP를 이용한 연구실적의 정량화 연구 - A연구소 기초연구사업을 중심으로 (A study on the quantitative evaluation of the performance in R&D with AHP)

  • 이석훈
    • 산업경영시스템학회지
    • /
    • 제19권39호
    • /
    • pp.219-227
    • /
    • 1996
  • For the equitable and objective evaluation of the performances of R & D (Research and Development) Projects, the quantitative evaluation of research products was performed. In this research, the AHP(Analytic Hierarchy Process) technique was used to calculate the relative importance(weight) of research products such as patents, thesis, conferences and man-power with make up individual questions. With calculated relative weight of research products, the model that gives the quantitative grades of research products was studied.

  • PDF

합성시험법을 이용한 진상소전류 성능검증에 관한 고찰 (Review for verification of capacitive current performance by using synthetic testing method)

  • 박승재;김용식;박용환;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.466-467
    • /
    • 2006
  • Several synthetic testing methods have widely been used for the performance evaluation of ultra high-voltage circuit breaker. Among these synthetic method, in the paper, capacitance switching testing method which can meet the test requirements and increase the testing capacity has been proposed. This method is made up of two separated sources of short-circuit generator for current source and L-C resonance circuit for voltage source. By using this method, KERI will perform the performance evaluation of capacitive current switching performance for the 800kV GCB(Gas Circuit Breaker).

  • PDF

반사율에 따른 광선반 채광 성능평가 연구 - 주거공간을 중심으로 - (Daylighting Performance Evaluation of Light-shelf according to the Reflectivity - Focused on the Residing space -)

  • 허도연;이행우;서장후;김용성
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: Due to recent increase on energy consumption for light in building, many studies to mitigate this issue have been conducted. Various researches have been carried out to suggest light shelf as one of the solutions, but researches for its reflectivity is very few. In fact, existing research on light shelf shows that utilizing more than 90% of high-illumination materials causes imbalance of glare and illuminance. Method: Therefore this research aimed to evaluate the performance of light shelves depending on reflectivity and to identify proper solution through test-bed. Result: The results are following: 1) Increased reflectivity generally contributed to increase of indoor illuminance but degrade uniformity factor related with indoor comfort of light environment. 2) The $0^{\circ}fixed$ light shelf with 75% of reflectivity and width of 300mm and 40mm appeared to consume more energy than other shelves. Therefore, it is analyzed as unsuitable. 3) This research was conducted by calculating appropriate angle of light shelf around winter and summer solstices and vernal/autumnal equinox. Based on this, performance evaluation was undertaken depending on reflectivity of movable light shelf, which is activated by external sources and can be applied with lower reflectivity than fixed shelf. However, one exception was a movable shelf with width of 600mm that increased light energy consumption when 75% of reflectivity was applied. 4) Performance evaluation of fixed and movable light shelf showed that the shelf with 80% of reflectivity came up with suitable results, but 75% of reflectivity may be applied depending on the width and angle of the shelf. This research is meaningful in that estimation of appropriate reflectivity of light shelf can resolve the glare problem and improve light environment, and further research would be desirable under more diverse conditions to identify proper solution.