• Title/Summary/Keyword: Research Development and Test Evaluation

Search Result 1,259, Processing Time 0.041 seconds

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

Evaluation of Supplemental Vitamin Premix in a Test Diet Containing Fish Meal as Protein Source for Juvenile Korean Rockfish (Sebastes schlegeli) (단백질원으로 어분이 첨가된 조피볼락 실험사료의 비타민 혼합물 평가)

  • Lee Sang-Min;Kim Sun-Myoung
    • Journal of Aquaculture
    • /
    • v.9 no.2
    • /
    • pp.159-166
    • /
    • 1996
  • A feeding experiment was conducted using juvenile Korean rockfish (Sebastes schlegeli) to evaluate supplemental vitamin premix in a test diet containing fish meal as protein source for nutritional study. Four vitamin premixes were prepared by adjusting different quantity and combination of vitamins. Each vitamin premix contained (mg/kg diet) : premix-1 : ascorbic acid, 2666 ; a-tocopheryl acetate, 417 ; thiamin, 60 ; riboflavin, 200 ; pyridoxine, 40 ; niacin, 800 ; Ca-D-pantothenate, 280 ; myo-inositol, 4000 ; D-biotin, 6 ; folic acid, 15 ; p-amino-benjoic acid, 400 ; mennadione, 40 ; A, 16 ; $D_3$, 0.1 ; choline chloride, 8000 ; cyanocobalamin, 0.09 ; premix-2 : ascorbic acid, 270 ; a-tocopheryl acetate, 189 ; thiamin, 13.5 ; riboflavin,, 27 ; pyridoxine, 13.5 ; niacin, 135 ; Ca-D-pantothenate, 135 ; myo-inositol, 135 ; D-biotin, 1. 4 : folic acid, 4.9 ; mennadione, 5.4 : A, 5.4 ; $D_3$, 2.2 ; choline chloride, 3000 ; cyanocobalamin, 0.05 ; premix-3 : ascorbic acid, 570 ; a-tocopheryl acetate, 107 ; thiamin, 20 ; riboflavin, 14.3 ; pyridoxine, 14.3 ; niacin, 71,3 ; Ca-D-pantothenate, 57 ; myo-inositol, 456 ; D-biotin, 0.7 ; folic acid, 2.9 ; p-aminobenjoic acid, 285 ; mennadione, 5.7 ; A, 5.7 ; $D_3$, 1.1 ; choline chloride, 1500 ; cyanocobalamin, 0.03 ; premix-4 : ascorbic acid, 190 : a-tocopheryl acetate, 36 ; thiamin, 6.7 ; riboflavin, 4.8 ; pyridoxine, 4.8 ; niacin, 23.8 ; Ca-D-pantothenate, 19 ; myo-inositol, 152 ; D-biotin,0.2 ; folic acid, 1 ; p-aminobenjoic acid, 95 ; mennadione, 1.9 ; A, 1.9 ; $D_3$, 0.4 ; choline chloride, 500 ; cyanocobalamin, 0.01. Triplicate groups of the 50 fish averaging 4.25 g were fed one of four isoproteic ($47\%$) and isolipidic ($9\%$) experimental diets to satiation twice a day for 10 weeks. Weight gain, feed efficiency and protein retention in fish fed the diet with vitamin premix-1 were significantly higher than those in fish fed the other diets (P<0.05). Moisture, protein and lipid contents of muscle and whole body were not affected by different dietary vitamin premix (P>0,05). These results indicate that premix-1 can be used to adequate supplemental vitamin premix in test diet containing fish meal as protein source for juvenile Korean rockfish.

  • PDF

Materials Compatibility and Structure Optimization of Test Department Probe for Quality Test of Fingerprint Sensor (지문인식센서 품질평가를 위한 검사부 프로브의 소재 적합성과 구조 최적화 연구)

  • Son, Eun-Won;Youn, Ji Won;Kim, Dae Up;Lim, Jae-Won;Kim, Kwang-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.73-77
    • /
    • 2017
  • Recently, fingerprint sensors have widely used for personal information security, and require quality evaluation to reduce an error of their recognition rate. Quality of fingerprint sensors is evaluated by variation of their electrical resistance introducing by contacts between a probe tip and a sensor electrode, Investigation on the materials compatability and structure optimization of probe is required to reduce deformation of sensor electrode for repeatability of quality testing. Nickel, steel(SK4), beryllium copper, and phosphor bronze were considered as probe materials, and beryllium copper was the most appropriate for materials of probe tips, considering indentation and contact resistance while being contacted probe tips on electrodes. Probes of an inspection part were manufactured with the single-unit structure for physical damage prevention and parallel processing capability. Inspection repeatability was evaluated by voltage variation of fingerprint sensors when the specific current was applied. A single-unit inspection part with beryllium copper probe tips showed excellent repeatability within ${\pm}0.003V$ of its voltage variation.

Evaluation of DOM Variations and Reduction Effects in Bioreation Artificial Wetland (생물반응 인공습지 내 DOM 변동 및 저감효과 평가)

  • Joo, Kwangjin;Lee, Jongjun;Kim, Tea-Kyung;Choi, Isong;Chang, Kwang-hyeon;Joo, Jinchul;Oh, Jongmin
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.582-594
    • /
    • 2018
  • In this study, the vertical and horizontal flow wetlands were combined in series to create conditions for flow in the exhalation and anaerobic state with the aim of monitoring the variability and reduction of dissolved organic matterin the bio-reactive artificial wetlands, and the performance assessment was conducted as acrylic reaction groups by designing artificial wetlands that filled the functionalresiduals. In case of artificial wetlands in vertical and horizontal planes, the concentration of dissolved oxygen (DO) in the reaction tank was measured as 2.7 mg/L in the vertical flow wetlands under exhalation, and N.D. in the horizontal flow artificial wetlands under anaerobic conditions. The test was carried out by changing the operation time to 140 min, 80 min, and 60 min. The test was conducted with the same natural operation time of 20 min depending on the operation time. All hours of operation were shown to be due to microbial activity. In 3D-EEM, it was found that the longer the driving time was taken, the more reduction the organic compounds in the areas of insoluble human resources, III and V. Further research on the mechanism analysis of future reduction effects is expected to be carried out, but the findings are expected to contribute to the development of technologies for reducing obfuscated substances using artificial wetlands in the future.

A Study on Simulation Based Fault Injection Test Scenario and Safety Measure Time of Autonomous Vehicle Using STPA (STPA를 활용한 자율주행자동차의 시뮬레이션 기반 오류 주입 시나리오 및 안전조치 시간 연구)

  • Ahn, Dae-ryong;Shin, Seong-geun;Baek, Yun-soek;Lee, Hyuck-kee;Park, Ki-hong;Choi, In-seong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.2
    • /
    • pp.129-143
    • /
    • 2019
  • As the importance of autonomous vehicle safety is emphasized, the application of ISO-26262, a development verification guideline for improving safety and reliability, and the safety verification of autonomous vehicles are becoming increasingly important, in particular, SAE standard level 3 or higher level autonomous vehicles detect and decision the surrounding environment instead of the human driver. Therefore, if there is and failure or malfunction in the autonomous driving function, safety may be seriously affected. So autonomous vehicles, it is essential to apply and verity the safety concept against failure and malfunctions. In this study, we study the fault injection scenarios for safety evaluation and verification of autonomous vehicles using ISO-26262 part3 process and STPA were studied and safety measures for safety concept design were studied through simulation bases fault injection test.

Performance Evaluation of Nitrogen Oxide Removal by Air Purification Blocks with Titanium Dioxide (이산화티타늄을 이용한 대기정화 블록의 질소산화물 제거 성능 평가)

  • Oh, Ri-On;Kim, Hwang-Hee;Park, Sung-Ki;Cha, Sang-Sun;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.39-46
    • /
    • 2020
  • This study evaluated the nitrogen oxide (NOx) removal efficiency by air purification concrete blocks with titanium dioxide (TiO2). The concrete in the mixtures had a 30% water:cement ratio, to which TiO2 was added at 0%, 5%, and 10% of cement weight. The compressive strength reduction rate and removal efficiency of NOx were investigated. The result of the compressive strength test in the study indicated that addition rate of TiO2 did not lead to signifcant effect. In terms of the average removal efficiency of NOx, mix No. 1 using a TiO2 mixing ratio of 0% had a removal efficiency of 0.57% on average; thus, the removal effect w as not significant. For the other samples prepared by mixing, the average removal efficiencies for mix No. 2 (5% TiO2) were 58.86% and 62.05% for normal and washing surface treatments, respectively, and those of sample No. 3 (10% TiO2) were 59.94% and 67.61%. mixs No. 4 (5%) and No. 5 (10%), in which TiO2 diluted with distilled water was sprayed onto the block surface, had an average NOx removal efficiency of 61.72% and 68.48%, respectively. In terms of NOx removal efficiency, Mixs No. 3 and No. 5 with 10% TiO2 were better than Mixs No. 2 and No. 4 with 5% TiO2. In addition, analyzing the NOx removal efficiency results from the fixing method, it was capable to apply mixing (washing) and the diluted spray methods. Therefore, it was found that the diluted spray method applied in this study can be employed in any manufacture of air purification concrete blocks.

The Structural Integrity Test for a PSC Containment with Unbonded Tendons and Numerical Analysis I (비부착텐던 PSC 격납건물에 대한 구조건전성시험 및 수치해석 I)

  • Noh, Sanghoon;Jung, Raeyoung;Kim, Sung-Taek;Lim, Sang-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.523-533
    • /
    • 2015
  • A reactor containment acts as a final barrier to prevent leakage of radioactive material due to the possible reactor accidents into external environment. Because of the functional importance of the containment building, the SIT(Structural Integrity Test) for containments shall be performed to evaluate the structural acceptability and demonstrate the quality of construction. An initial numerical analysis was performed to simulate the results obtained from the SIT for a prestressed concrete(PSC) structure. But the analysis results by the initial model expected smaller displacements than the measured ones by 30% at some locations. Accordingly, the research and development to improve the initial model to corelate the measured results of the SIT more properly have been performed. In this paper, the effects of the loss of concrete due to duct for tendons and the contact of duct and tendons in un-bonded tendon system are mainly evaluated based on the preliminary analysis results. In addition, the importances of the proper definition of mesh connectivity among structural elements of concrete, liner plates, rebars and tendons are discussed.

Constructability Evaluation of Seismic Mechanical Splice for Slurry Wall Joint Consisting of Steel Tube and Headed Bars (슬러리월의 내진설계를 위한 강재각관과 확대머리 철근으로 구성된 기계적 이음의 시공성 평가)

  • Park, Soon-Jeon;Kim, Dae-Young;Lim, In-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.295-303
    • /
    • 2023
  • South Korea has recently witnessed an increasing number of seismic events, leading to a surge in studies focusing on seismic earth pressures, as well as the attributes of geological layers and ground where foundations are established. Consequently, earthquake-resistant design has become imperative to ensure the safety of subterranean structures. The slurry wall method, due to its superior wall rigidity, excellent water resistance, and minimal noise and vibration, is often employed in constructing high-rise buildings in urban areas. However, given the separation between panels that constitute the wall, slurry walls possess limited resistance to seismic loads in the longitudinal direction. As a solution, several studies have probed into the possibility of interconnecting slurry wall panels to augment their seismic performance. In this research, we developed and evaluated a method for linking slurry wall panels using mechanical joints, including concrete-confined steel pipes and headed bars, through mock-up tests. We also assessed the constructability of the suggested method and compared it with other analogous methods. Any challenges identified during the mock-up test were discussed to guide future research in resolving them. The results of this study aid in enhancing the seismic performance of slurry walls through the development of an interconnected panel method. Further research can build on these findings to address the identified issues and improve the efficacy and reliability of the proposed method.

Development of dimethyl disulfide gas CRM and stability test (다이메틸다이설파이드 가스 인증표준물질 개발 및 안정성 평가)

  • Kim, Young-Doo;Woo, Jin-Chun;Bae, Hyun-Kil
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.498-503
    • /
    • 2006
  • A type of dimethyl disulfide gas CRM in the ppb level was developed for the analysis of tracelevel odorous gas in environmental atmosphere. The concentration of dimethyl disulfide($(CH_3)_2S_2$) was $10{\mu}mol/mol$ level in the cylinder filled with nitrogen, 1500 psi. And the variability of the concentration for 2 years was about 0.14% due to the adsorption or instability of $(CH_3)_2S_2$. The gas standards produced simultaneously in 4 bottles and examined by GC-FID were shown with 0.4%, reproducibility of preparation and 0.25%, standard uncertainty due to weighing and purity. The relative expended uncertainty of 1.1%(95% of confidence level, k=2) was assigned to the certified value of $10{\mu}mol/mol$ level of $(CH_3)_2S_2$ after quantitative evaluation on the purity, mixing, weighing, analysis, adsorption and stability of dimethyl sulfide gas.

A Study for establishment of soil moisture station in mountain terrain (1): the representative analysis of soil moisture for construction of Cosmic-ray verification system (산악 지형에서의 토양수분 관측소 구축을 위한 연구(1): Cosmic-ray 검증시스템 구축을 위한 토양수분량 대표성 분석 연구)

  • Kim, Kiyoung;Jung, Sungwon;Lee, Yeongil
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • The major purpose of this study is to construct an in-situ soil moisture verification network employing Frequency Domain Reflectometry (FDR) sensors for Cosmic-ray soil moisture observation system operation as well as long-term field-scale soil moisture monitoring. The test bed of Cosmic-ray and FDR verification network system was established at the Sulma Catchment, in connection with the existing instrumentations for integrated data provision of various hydrologic variables. This test bed includes one Cosmic-ray Neutron Probe (CRNP) and ten FDR stations with four different measurement depths (10 cm, 20 cm, 30 cm, and 40 cm) at each station, and has been operating since July 2018. Furthermore, to assess the reliability of the in-situ verification network, the volumetric water content data measured by FDR sensors were compared to those calculated through the core sampling method. The evaluation results of FDR sensors- measured soil moisture against sampling method during the study period indicated a reasonable agreement, with average values of $bias=-0.03m^3/m^3$ and RMSE $0.03m^3/m^3$, revealing that this FDR network is adequate to provide long-term reliable field-scale soil moisture monitoring at Sulmacheon basin. In addition, soil moisture time series observed at all FDR stations during the study period generally respond well to the rainfall events; and at some locations, the characteristics of rainfall water intercepted by canopy were also identified. The Temporal Stability Analysis (TSA) was performed for all FDR stations located within the CRNP footprint at each measurement depth to determine the representative locations for field-average soil moisture at different soil profiles of the verification network. The TSA results showed that superior performances were obtained at FDR 5 for 10 cm depth, FDR 8 for 20 cm depth, FDR2 for 30 cm depth, and FDR1 for 40 cm depth, respectively; demonstrating that those aforementioned stations can be regarded as temporal stable locations to represent field mean soil moisture measurements at their corresponding measurement depths. Although the limit on study duration has been presented, the analysis results of this study can provide useful knowledge on soil moisture variability and stability at the test bed, as well as supporting the utilization of the Cosmic-ray observation system for long-term field-scale soil moisture monitoring.