• Title/Summary/Keyword: Required evacuation distance

Search Result 8, Processing Time 0.021 seconds

A Study on the Variation of Evacuation Time according to the Width of Corridor and the Emergency Exit in Gosiwon's Fire State (고시원 화재시 복도 및 비상구 폭에 따른 피난소요시간 변화에 관한 연구)

  • Kim, Jin-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.133-138
    • /
    • 2009
  • The purpose of this study is to present an alternative plan in order to reduce the required time to flee from the inside of the gosiwon in danger. The data were derived from changing the width of corridors and emergency exits and the number of stairs in the building EXODUS, which is computer simulation program, The analyzed conclusions from the data are following as below (1) Increasing the exits and the number of stairs are efficient to reduce the accumulated time for standing by. (2) Increasing the number of stairs is efficient to decrease the distance to get out of the building to exit. (3) Increasing the number of stairs is efficient to reduce the time to get out of the building to exit.

  • PDF

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.

A study on pedestrian path search based on the shortest distance algorithm using Map API (Map API를 활용한 최단 거리 알고리즘 기반 보행자 경로 탐색 연구)

  • Jeon, Sung-woo;Kim, Yunbae;Kim, Junyoung;Park, Seonyoung;Jung, Heo-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.219-221
    • /
    • 2022
  • In recent summer, as it is concentrated, even in mountainous areas, flooding and flooding cause casualties in pedestrian evacuation situations. To compensate for this, a system that detects the occurrence of flooding and allows pedestrians to evacuate safely is required. Therefore, in this paper, we propose a research on pedestrian path search based on the shortest distance algorithm using Map API. The pedestrian route search system outputs a map using the T Map API, selects nearby buildings as shelters, and stores data. A shelter close to the pedestrian's current location is selected, and the shortest route is output and the distance and time are provided. If there is a problem with the current route during evacuation, another shelter route is provided from the current location. Therefore, it is thought that the pedestrian route search evacuation system proposed in this paper will prevent accidents during evacuation.

  • PDF

Analysis of suitable evacuation routes through multi-agent system simulation within buildings

  • Castillo Osorio, Ever Enrique;Seo, Min Song;Yoo, Hwan Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.5
    • /
    • pp.265-278
    • /
    • 2021
  • When a dangerous event arises for people inside a building and an immediate evacuation is required, it is important that suitable routes have been previously defined. These situations can happen especially when buildings are crowded, making the occupants have a very high vulnerability and can be trapped if they do not evacuate quickly and safely. However, in most cases, routes are considered based just on their proximity or short distance to the exit areas, and evacuation simulations that include more variables are not performed. This work aims to propose a methodology for building's indoor evacuation activities under the premise of processing simulation scenarios in multi-agent environments. In the methodology, importance indexes of simplified and validated geometry data from a BIM (Building Information Modeling) are considered as heuristic input data in a proposed algorithm. The algorithm is based on AP-Theta* pathfinding and collision avoidance machine learning techniques. It also includes conditioning variables such as the number of people, speed of movement as well as reaction ability of the agents that influence the evacuation times. Moreover, collision avoidance is applied between people or with objects along the route. The simulations using the proposed algorithm are tested in NetLogo for diverse scenarios, showing feasible evacuation routes and calculating evacuation times in a multi-agent environment. The experimental results are obtained by applying the method in a study case and demonstrate the level of effectiveness of the algorithm, and the influence of the conditioning variables analyzed together when performing safe evacuation routes.

Evaluation of the Size of Emergency Planning Zone for the Korean Standard Nuclear Power Plants (한국표준형 원전에 대한 방사선비상계획구역 범위 평가)

  • Jeon, In-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.215-223
    • /
    • 2003
  • Against major release of radioactive material in nuclear power plant, Emergency Planning Zone(EPZ)s are typically established around nuclear power plants to effectively perform the public protective measures. The domestic methodology to determine the size of the EPZ is similar to that of Japan established in 1980, where calculations were based on the conservative accident source term. The objective of this study is to re-evaluate the validity of established EPZ, the area within the radius of $8{\sim}10km$ around domestic nuclear power plants, using the source terms covering full spectrum of accidents obtained from PSA study of ULJIN 3&4. To evaluate the risks of health effects, the computer code MACCS2(MELCOR Accident Consequence Code System2) was used. The result shows that the existing EPZ can reduce the probability of early fatality adequately for most of the source term categories(STCs) except for STC-14 and STC-19. In case of STC-14 and 19, the evacuation distance of 16km and 13km, respectively, are required. These distances can be reduced by improving emergency preparedness since the sensitivity studies for the public protective actions show that the magnitude of early fatality is largely affected by the time delays in notification and evacuation.

A study on the effective fire and smoke control in transverse oversized exhaust ventilation (횡류식 선택대배기환기에서의 배연특성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.451-462
    • /
    • 2011
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume with scaled-model and simulation when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250 m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation (Oversized Exhaust System) (도로터널 화재시 반횡류식 환기방식에서의 최적배연 연구(대배기구 방식))

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.79-84
    • /
    • 2009
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75m/s and 2.5m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

The Effectiveness Evaluation of Helicopter Ambulance Transport among Neurotrauma Patients in Korea

  • Park, Kyoung Duck;Seo, Sook Jin;Oh, Chang Hyun;Kim, Se Hyuk;Cho, Jin Mo
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.1
    • /
    • pp.42-47
    • /
    • 2014
  • Objective : Helicopter ambulance transport (HAT) is a highly resource-intensive facility that is a well-established part of the trauma transport system in many developed countries. Here, we review the benefit of HAT for neurosurgical patients in Korea. Methods : This retrospective study followed neurotrauma patients who were transferred by HAT to a single emergency trauma center over a period of 2 years. The clinical benefits of HAT were measured according to the necessity of emergency surgical intervention and the differences in the time taken to transport patients by ground ambulance transport (GAT) and HAT. Results : Ninety-nine patients were transferred to a single university hospital using HAT, of whom 32 were taken to the neurosurgery department. Of these 32 patients, 10 (31.3%) needed neurosurgical intervention, 14 (43.8%) needed non-neurosurgical intervention, 3 (9.4%) required both, and 11 (34.4%) did not require any intervention. The transfer time was faster using HAT than the estimated time needed for GAT, although for a relatively close distance (<50 km) without ground obstacles (mountain or sea) HAT did not improve transfer time. The cost comparison showed that HAT was more expensive than GAT (3,292,000 vs. 84,000 KRW, p<0.001). Conclusion : In this Korean-based study, we found that HAT has a clinical benefit for neurotrauma cases involving a transfer from a distant site or an isolated area. A more precise triage for using HAT should be considered to prevent overuse of this expensive transport method.