• Title/Summary/Keyword: Reproducibility evaluation

Search Result 347, Processing Time 0.025 seconds

Evaluation of the mandibular asymmetry using the facial photographs and the radiographs (방사선사진과 안모사진을 이용한 하악 비대칭의 평가)

  • Lee Sul-Mi
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.199-204
    • /
    • 2001
  • Purpose : To assess the relationship between soft tissue asymmetry and bone tissue asymmetry using the standardized photographs and the posteroanterior (PA) cephalometric radiographs in mandibular asymmetric patients. And to clarify that the lack of morphologic balance among different skeletal components can often be masked by compensatory soft tissue contributions. Methods: Experimental group consisted of 58 patients whose chief complaints were facial asymmetry, they were taken with standardized facial photographs and PA cephalometric radiographs. Control group consisted of 30 persons in the normal occlusion. The reproducibility of the facial photograph was confirmed by model test. The differences of fractional vertical heightand horizontal width from standardized facial photographs and PA cephalometric radiographs were compared and analyzed. Results: The difference of fractional vertical bone height was 0.63 and fractional vertical soft height was 0.58 in control group, 3.10 and 2.01 in asymmetric group, respectively. The difference of fractional horizontal bone width was 0.52 and fractional horizontal soft width was 0.70 in control group, 2.51 and 1.70 in asymmetric group, respectively. Both soft and bone tissue showed significant difference between control and asymmetric group (p<0.05). The difference of bone tissue was greater than that of soft tissue (p<0.05) in the experimental group but, not in control group. Conclusions: Soft tissue components may compensate for underlying skeletal imbalances.

  • PDF

Development and Psychometric Testing of the Clinical Nursing Competency Scale for Clinical Preceptor Use (CNCS-CP) (임상간호실습 현장지도자용 임상간호역량 평가도구 개발)

  • Kwak, Eunmi;Oh, Heeyoung
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.4
    • /
    • pp.419-431
    • /
    • 2018
  • Purpose: The purpose of this study was to develop and establish the psychometric properties of a clinical nursing competency evaluation tool to be utilized by clinical preceptors. Methods: The initial items were identified through in-depth literature review and field interviews based on a hybrid model. Content validation of the items was evaluated through three rounds of content validity testing. Participants were 34 clinical preceptors and 443 nursing students participating in clinical practice. Data were analyzed using exploratory and confirmatory factor analysis, convergence and discriminant validity, internal consistency and inter-rater reliability. Results: The final scale consisted of 23 items and four factors, fundamental nursing skills performance, critical thinking skills based on the nursing process, basic nursing knowledge, and professional attitude; these factor explained 69.7% of the total variance. The analysis with multi-trait/multi-item matrix correlation coefficients yielded 100.0% and 95.7 % convergence and discriminant validity, respectively. Cronbach's alpha for the total items was .95. The four subscale model tested by confirmatory factor analysis was satisfactory. Inter-rater reliability ranged from .912 to .967. Conclusion: This scale was found to be a reliable and valid instrument that clinical preceptors can apply for evaluating the clinical nursing competency of nursing students in clinical settings.

Color Image Acquired by the Multispectral Near-IR LED Lights (다중 파장 근적외선 LED조명에 의한 컬러영상 획득)

  • Kim, Ari;Kim, Hong-Suk;Park, Youngsik;Park, Seung-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.1-10
    • /
    • 2016
  • A system which provides multispectral near-IR and visible gray images of objects is constructed and an algorithm is derived to acquire a natural color image of objects from the gray images. A color image of 24 color patches is obtained by recovering their CIE (International Commission on Illumination) LAB color coordinates $L^*$, $a^*$, $b^*$ from their gray images using the algorithm based on polynomial regression. The system is composed of a custom-designed LED illuminator emitting multispectral near-IR illuminations, fluorescent lamps and a monochrome digital camera. Color reproducibility of the algorithm is estimated in CIELAB color difference ${\Delta}E^*_{ab}$. And as a result, if yellow and magenta color patches with around 10 ${\Delta}E^*_{ab}$ are disregarded, the average ${\Delta}E^*_{ab}$ is 2.9, and this value is within the acceptability tolerance for quality evaluation for digital color complex image.

Analysis of efficiency of X-ray equipment for medical service (의료용 X-ray 기기의 성능평가)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.426-426
    • /
    • 2009
  • Diagnostic X-ray system is general and basic medical equipment to be used in mostly medical organizations, but being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This paper has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

  • PDF

A Study on the Therapeutic Effects of Occlusal Appliance on Temporomandibular Disorders (측두하악장애환자의 교합안정장치 치료효과에 관한 연구)

  • Seok-Man Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.13 no.1
    • /
    • pp.5-12
    • /
    • 1988
  • The purpose of this study was to evaluate the therapeutic effect of occlusal stabilization splint on the clinical symptoms and the condylar movement in patients with Temporomandibular Disorders(TMD). For the study, 15 TMD patients treated with stabilization splint and followed up were selected. The age of them was from 18 to 65 years and the mean period of treatment was 2.9 months. The author examined signs and symptoms of TMD according to Dr. Friction's evaluation from and recorded the condylar paths with Denar pantronic before and after splint therapy. The obtained results were as follows : 1. On the first visit, 11 patients(73.3%) showed muscle tenderness on palpation and the frequency was lateral pterygoid, masseter, medial pterygoid, temporalis, sternocleidomastoideus in the order named. 2. Occlusal stabilization splint was more effective in pain relief(100%) than in other dysfunction improvement(85.7%) 3. The amount of maximum opening increased from 37.1㎜ to 42.2㎜, but those of protrusion and laterotrusion changed little. 4. Pan. PRI scores decreased from 32.9 to 21.8, which meant improved reproducibility of mandibular border movements, and the group with sever dysfunction category showed more decrease in score than the group with moderate or slight dysfunction category.

  • PDF

Change of Pulmonary Function after Pulmonary Resection (폐절제술후 폐기능 변화에 관한 연구)

  • 김용진
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.517-528
    • /
    • 1985
  • Pulmonary function studies today are generally accepted as an integral part of the evaluation of poor-risk patients who are to have pulmonary surgery. The effect of various pulmonary surgery on lung function was investigated in 54 patients in whom comprehensive lung function test were performed before and between 2 months and 14 months after operation at the Department of Thoracic Surgery, Seoul National University Hospital. According to the result of analysis, the effect of pulmonary resection on forced flow rate was keeping with the change of lung volume, and the preoperative level of ventilatory function plays a major role in determining postoperative loss of functioning lung. Although all measures of expiratory flow [FVC, FEV1, FEFO.2-1.2, MEF50, FEF25-75] have the same percentage of reproducibility, but FEV1 shows most sensitive, reliable linear correlation with the functioning pulmonary tissue loss than other parameters. The linear regression lines derived from the correlation between preoperative [X] and postoperative [Y] FEV1 on various surgical procedures were as follows: 1. Y = 0.57X 0.03. in pneumonectomy group of lung cancer[r=0.84]. 2. Y = 0.56X + 0.33. in lobectomy group of lung cancer[r=0.79]. 3. Y = 0.69X + 0.25. in lobectomy group of pulmonary infection[r=0.91].

  • PDF

Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method (Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC))

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

Development of Collision Tester for Performance Evaluation of Safety Fence in Baseball Stadiums (야구장 안전펜스 성능평가를 위한 충돌시험기 개발)

  • Han, Eui Don;Jang, Woong Ki;Kho, Sun Tak;Kwak, Ho Taek;Seo, Young Ho;Kim, Byeong Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.957-962
    • /
    • 2013
  • This paper presents a performance testing device for safety fences of domestic professional baseball stadiums. Safety fences of professional stadiums have been fabricated and installed without adhering to any safety regulations, safety fences demonstrate critically low safety performances and many outfielders are severely injured every season. In this study, we designed and fabricated a performance testing device for safety fences and investigated its validity and reproducibility. A HIC (head injury criterion) was used for the statistical analysis of colliding data. We found that the optimal expulsion pressure and eliminated the accelerometer by replacing it with a velocity sensor using an estimation of the correlation between the momentum data obtained from velocity sensor and the impulse data from the accelerometer.

Oxygen Permeability Characteristics of the Multi-Cathode Type Dissolved Oxygen Sensor Using the Low Noise Measuring Circuit (저잡음화 계측회로에 의한 다음극형 용존산소센서의 산소투과특성)

  • Rhie, Dong-Hee;Kim, T.J.;Kim, Y.H.;Sung, Yung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.764-766
    • /
    • 1998
  • An evaluation method for oxygen permeable characteristics of the membrane covering to each cathode of multiple cathode - single anode type dissolved oxygen sensor, which has high reproducibility and is capable of measuring multiple components in solutions. For this purpose, a measuring circuit for the multiple cathode type DO sensor was designed to lower the noise signal by adapting a digital LPF to readout the sensor output accurately. Digital LPF is designed by setting up the transfer function to set the cutoff frequency to 10Hz, and the transfer function is programmed by C language, and then the filtering characteristics are evaluated with the simulation and experiments. Using this LPF added measuring circuit for the multiple cathode type DO sensor, we have obtained the calibration factor for each cathode to calibrate the variation of the output signals. The calibration factor was obtained by measuring the sensor output signal followed by oxygen partial pressure, using the same oxygen permeable membrane at each cathode of the multiple cathode type DO sensor.

  • PDF

Small Punch Test for the Evaluation of Thermal Aging Embrittlement of CF8 Duplex Stainless Steel

  • Cheon, Jin-Sik;Kim, In-Sup;Jang, Jae-Gyoo;Kim, Joon-Gu
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.79-84
    • /
    • 1996
  • Small punch test was performed on CF8 duplex stainless steel aged at 370 and 400$^{\circ}C$ up to 5,000 h to evaluate the degree of the thermal aging embrittlement. At room temperature, the SP load-displacement curve was in a similar shape to those of ferritic steels and had a good reproducibility in spite of two-phase structure. The aging heat treatment resulted in a slight increase of the yield strength. As test temperature was lowered, the SP load showed a sudden drop followed by serrations before the SP specimen was fractured, resulting from the cracking of ferrite phase. The extent of thermal embrittlement was assessed in terms of the SP energy. Aging treatment at higher temperature led to a larger shift in the transition temperature and the corresponding change in the fracture mode. The main cause of the degradation was the embrittlement of ferrite phase. Additionally the phase boundary separation profoundly contributed to the degradation of the specimen aged at 400$^{\circ}C$.

  • PDF