• Title/Summary/Keyword: Replica restoration

Search Result 23, Processing Time 0.026 seconds

Influence of final crystallization process on precision of fit of monolithic CAD/CAM-generated restorations by lithium disilicate: A comparative study (리튬 디실리케이트 최종 결정화 과정이 CAD/CAM으로 제조된 수복물의 적합도에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To quantify the effect of the crystallization process on lithium disilicate ceramic crowns that are fabricated using a computer-aided design/computer-aided manufacturing(CAD/CAM) system, and to determine whether they are clinically acceptable by comparing values before and after the crystallization process. Methods: The maxillary first molar was selected as the abutment for the experiments. Ten working models were prepared. Marginal and internal gap of 4 groups of lithium disilicate crowns(n=10) fabricated with conventional method. Comparison was performed using the silicone replica technique and 3D superimposition analysis. The marginal and internal gaps of the restoration were measured before and after the crystallization process of this prosthesis. The average value of each part(the average of values measured before and after the crystallization) was statistically analyzed using paired t-test(α=0.05). Results: The results from the second phase of this research, which compared the average value of the gap between the marginal and internal fits of the lithium disilicate single crown before and after the crystallization process, indicated that the marginal gap was larger and the internal gap was smaller after the crystallization process, and this difference was statistically significant (P<0.05) in all the parts evaluated. Conclusion: While the shrinkage that occurs during crystallization does affect the marginal and internal fit of the prosthesis, it cannot be concluded to be a major effect because the resultant distortion was within the clinically acceptable range.

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

  • Lee, Wan-Sun;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are $171.6\;(97.4){\mu}m$ for the crown manufactured by the milling system and 149.1 (65.9) and $91.1\;(36.4){\mu}m$, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

Restoration and Scientific Analysis of Casting Bronze Type in Joseon Dynasty (조선왕실 주조 청동활자의 복원과 과학적 분석)

  • Yun, Yong-Hyun;Cho, Nam-Chul;Lee, Seung-Cheol
    • Journal of Conservation Science
    • /
    • v.25 no.2
    • /
    • pp.207-217
    • /
    • 2009
  • After replicating 10 bronze types such as Gyemija, Gyeongjaja, Eulhaeja, etc. before the Imjin war, we studied the change of microstructure from each casting process, method, and alloy ratio by Gyechukja replicated from "Donggukyeojiseungnam". We selected the average of compositions of Eulhaeja in the National Museum of Korea as the standard(Cu 86.7%, Sn: 9.7%, Pb: 2.3%) of bronze types, so we decided on the alloy's composition of Cu 87%, Sn 15%, Pb 8% added to 5% Sn and Pb contents because of evaporating the Sn and the Pb. Before replicating major metal types, we made master-alloy first, melting it again, and then replicated metal types. The composition of the 1'st replicated Gyechukja showed the range of Cu 85.81~87.63%, Sn 9.27~10.51%, Pb 3.05~3.19%. The 2'nd replicated Gyechukja made using the branch metal left after casting the 1st replica. The 2nd replicated Gyechukja showed the composition range of Cu 87.21~88.09%, Sn 9.06~9.36%, Pb 2.80~3.05%. This result decreases a little contents of Sn and Pb as compared with metal types of the 1st replica. However, it's almost the same as the Eulhaeja's average composition ratio in the National Museum of Korea. As a result of observing the microstructure of restored Gyechukja, it showed the dendrite structure of the typical casting structure and the segregation of Pb. There is no big difference of microstructure between the 1st and the 2nd restored metal types, even though the 2nd restored types partially decreases the eutectoid region in comparison with the 1st types. The systematic and scientific restoration experiment of metal types using Joseon period will be showed the casting method and alloy ratio, and this will be of great help to the study of restoration metal types in the future.

  • PDF

ESTIMATION OF RELATION BETWEEN TECHNIQUES OF DYE PENETRATION FOR MICROLEA-KAGE AND SEM EVALUATION FOR MARGINAL ADAPTATION OF THE RESTORATION (수복물의 미세누출도와 변연적합도 측정에 사용되는 방법 사이의 상관 관계 평가)

  • Hwang, Soon-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.337-343
    • /
    • 2006
  • The purpose of this study was to estimate the relation between techniques used for microleakage from dye penetration and for marginal adaptation from SEM evaluation of the restoration. Using high speed #330 bur class V cavities ($4{\times}3{\times}1.5 mm$ around CEJ) were prepared on the buccal surface of 20 extracted human molars. Six dimples as reference points for SEM and dye penetration evaluation were made with 1/2 round bur. Cavity was bulk filled with microhybrid composite resin (Esthet X) and all-in-one adhesive (Xeno III). Teeth were stored in saline solution for one day, after then, they were finished and polished using Sof-Lex system. Fifty percent silver nitrate dye solution was used for the evaluation of microleakage and resin replica was used for marginal adaptation. All of these were done after 1000 times thermocycling between 5 and $55^{\circ}C$. Vertical sections were made through three dimples of restoration to obtain samples for the evaluation of dye penetration and inner marginal adaptation. Outer adaptational estimation was done with an intact restoration before sectioning. Dye penetration was determined in three degrees and percentage of outer and inner leaky margin was estimated from SEM image The data were analysed statistically: Spearman's rho test were used to check relationships between two methods. The result were as follows : 1. There were significant relationships between degree of dye penetration and inner and outer marginal adaptations each (p < 0.01). 2. However, there was no significant relationship between the results or inner and outer marginal adaptation. Within the results of this study, relationship between the percentage of marginal adaptation and microleakage shows significant relationship. However, inner and outer marginal adaptation did not show any significant relationship mutually.

In vitro evaluation methods on adaptation of fixed dental prosthesis (고정성 보철물의 적합도에 대한 실험적 평가방법)

  • Lee, Hyunho;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.63-70
    • /
    • 2017
  • Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.

Analysis of Cow Hide Glue Binder in Traditional Dancheong by Enzyme-linked Immunosorbent Assay

  • Yu, Jia;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.4
    • /
    • pp.363-372
    • /
    • 2019
  • Animal glue has been used as a binder in Dancheong since the Joseon dynasty. Binders play an important role in determining the physical characteristics of a painting layer. The analysis of binders can be used to identify the materials and techniques used in traditional Dancheong. Binders can be investigated using physicochemical component analyses methods such as gas chromatography/mass spectrometry, pyrolysis-gas chromatography/mass spectrometry, and fourier transform infrared spectroscopy, but the detection characteristics vary depending on the degradation properties of the pigment and binder. Therefore, cross-validation using a combination of physicochemical analysis and enzyme immunoassay is used to increase the reliability of the results. In this study, we present an enzyme-linked immunosorbent assay (ELISA) as an example of an enzyme immunoassay as a method for analyzing animal glue, a traditional binder used in Korea. The applicability of ELISA was tested using commercial animal glue, in addition to animal glue produced using a variety of extraction conditions. The animal glue was analyzed in a Noerok-additionally coated-replica sample to evaluate the possibility of analyzing the animal glue in a paint layer mixed with pigment. Based on the results, we performed an assay on the use of animal glue in the Dancheong sample of the temples of the Joseon dynasty, that are estimated to have been built in the 17th century.

Evaluation of the marginal and internal fit of lithium disilicate crowns fabricated by different scanning methods (다른 스캐닝 방법으로 제작된 리튬 디실리케이트 단관의 변연 및 내면 적합도 평가)

  • Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.75-81
    • /
    • 2014
  • Purpose: This study was to compare adaptations of lithium disilicate CAD/CAM crowns fabricated with different scanning systems. Methods: This study selected the mandibular right first molar as an abutment for experiments and produced 10 working models. Lithium disilicate crowns appropriate for each abutment were produced by using a CEREC$^{(R)}$ CAD/CAM system. The independent t-test was then used to compare and analyze the data obtained from the two groups(${\alpha}$=0.05). Results: Mean(SD) adaptation were $86.93(22.82){\mu}m$ for the InS group, $88.42(26.77){\mu}m$ for the ExS group. They were no statistically significant differences between groups for adaptation(p>0.05). Conclusion: Within the limitations of this study, the results suggest that the accuracy of all investigated optical scanner were satisfactory for clinical use. Further assessment and improvement of the lithium disilicate ceramic for the fabrication of FPDs is evidently still required.

Evaluation of marginal fit of monolithic zirconia restoration by digital impression (디지털 방식을 이용하여 제작한 전부 지르코니아 수복물의 변연 적합도 평가)

  • Yun, Mi-Jung;Kim, So-Yeun;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.56 no.7
    • /
    • pp.366-374
    • /
    • 2018
  • Purpose : The purpose of this study was to compare the marginal fit of monolithic zirconia restorations fabricated form the conventional and the digital impression technique. Materials and methods : Ten patients were restored with monolithic zirconia restorations fabricated from the digital and the conventional impression technique. Before definitive insertion, silicone replicas were produced from all twenty crowns. The silicone replicas were cut in three sections; each section was evaluated at two points. The measurement was carried out by using a measuring microscope (Olympus BX 51) and I-Solution. Data from the silicone replica scores were analyzed by Shapiro-Wilk test for normal distribution and the t-test for equality of two population's mean. All tests were performed with ${\alpha}-level$ of 0.05. Results : The average marginal gaps of monolithic zirconia restorations were $133.81{\pm}36.46{\mu}m$ for the conventional impression technique, $90.07{\pm}9.47{\mu}m$ for the digital impression technique. No statistical differences were found between the two impression techniques Conclusion : Both prostheses presented clinically acceptable results with comparing the marginal fit.

  • PDF

INTERFACIAL MORPHOLOGY BETWEEN DENTIN AND ADHESIVES ACCORDING TO TREATMENT OF DENTIN SURFACE OF CERVICAL ABRASION LESION (치경부 마모병소의 상아질 표면처리 방식에 따른 상아질과 접착제 간의 계면 양상)

  • Lee, Yong-Hee;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.51-63
    • /
    • 2001
  • In order to know the effect of dentin bonding agents on the restoration of cervical abrasion, Scotchbond Multipurpose Single Bond and Clearfil Liner Bond 2 were used in 51 teeth with abrasion lesion and normal teeth. The surface structure and dentinal tubules of acid etched dentin and resin replica were examined using scanning electron microscopy. The interfacial morphology between dentin and adhesives was investigated by confocal laser scanning microscopy. Following results were obtained. 1. The hybrid layer and resin tag of the dentin showing cross-sectional surface of dentinal tubules are thicker and longer than those of dentin showing oblique surface of dentinal tubules. 2. The sclerotic cast was frequently observed in dentinal tubule, and the cast looked like cuboidal or rhomboidal-shaped crystals clumped from outer side to inner side. 3. The formation of hybrid layer and resin tag was the most prominent in Scotchbond Multipurpose group, whereas Clearfil Liner Bond 2 group showed very poor formation. The formation of hybrid layer and resin tag in Single Bond group was less than Scotchbond Multipurpose group.

  • PDF

An Evaluation Validity of the Silicone Replica Technique at Measurement on Fit of Fixed Dental Prostheses (고정성 보철물의 적합도 측정 시 사용하는 실리콘 복제본 기술의 정확도 평가)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.566-571
    • /
    • 2012
  • Marginal and internal fit are very important factor for the clinical long-term success of fixed dental prostheses (FDPs). A variety of methods have been applied to the measuring marginal and internal fit of FDPs. The purpose of this study was to compare the marginal and internal fit of 2 different measuring methods silicone replica technique [SRT] and die cutting technique (DCT). SRT, the space between die and FDPs were filled with light-body silicone, then stabilized by medium-body silicone. DCT, the FDPs were cemented on definitive dies and embedded into epoxy. The silicone replicas and epoxies were sectioned mesio-distal and measured 4 locations (margin, rounded chamfer, axial, occlusal) and using a digital microscope at a magnification $\times$160. For the SRT the mean${\pm}$SDs fit (${\mu}m$) recorded were: margin $88.7{\pm}22.2$, rounded chamfer $90.6{\pm}25.0$, axial wall $61.5{\pm}21.8$, occlusal $134.9{\pm}30.8$. For the DCT the mean${\pm}$SDs fit (${\mu}m$) recorded were: margin $85.3{\pm}18.0$, rounded chamfer $85.4{\pm}24.7$, axial wall $62.0{\pm}21.3$, occlusal $131.7{\pm}30.5$. The mean${\pm}$SDs size (${\mu}m$) of SRT margin was $88.7{\pm}22.2$ and of DCT margin was $85.3{\pm}18.0$. There were no statistically significant difference (p<0.05) of the four parts between SRT and DCT. It is considered an appropriate case to use SRT at fit of FDPs.