• Title/Summary/Keyword: Replica restoration

Search Result 23, Processing Time 0.04 seconds

A technique for fabricating abutment replica with hot melt adhesive material to minimize residual cement in implant restoration: a case report (임플란트 보철 합착 시 잔여 시멘트 최소화를 위해 열가소성 접착제를 이용한 복제 지대주 제작 방법: 증례보고)

  • Seo, Chi-Won;Han, A-Reum;Seo, Jae-Min;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.240-245
    • /
    • 2016
  • Removal of excess cement is important to prevent biological complication in cementation of implant restoration with subgingival margin. It can be difficult to completely remove excess cement. Several techniques have been introduced to minimize excess cement using abutment replica. In this case report, a simple method for making abutment replica with hot melt adhesive material in dental office was described. This technique is simple and effective because it can be used for pre-fabricated or custom abutment without additional laboratory procedure. In addition, it can minimize excess cement after cementation of implant restoration.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis

  • Mai, Hang-Nga;Lee, Kyeong Eun;Lee, Kyu-Bok;Jeong, Seung-Mi;Lee, Seok-Jae;Lee, Cheong-Hee;An, Seo-Young;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.358-363
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.

A Study on Replica Restoration Methods through Scientific Analysis of Seongju Lee Family's Portraits (성주 이씨가(家) 초상화의 과학적 분석을 통한 모사복원방안 연구)

  • Jeong, Ji-Youn;Lee, Jang-Jon;Han, Min-su
    • Journal of Conservation Science
    • /
    • v.38 no.3
    • /
    • pp.201-216
    • /
    • 2022
  • Materials and techniques used for two portraits (Jo-nyeon Lee and S ung-in Lee) of the Lee family from Seongju enshrined in Seongsan temple were scientifically analyzed, and based on the data, an optimal replica restoration method was designed. According to the expression technique investigation, both portraits were expressed mainly in line drawing, but there were differences in shoes, pupils, the color expression of flesh, overpainting, and traces of reinforcement. Pigment analysis revealed that a mixture of cinnabar and minium, organic pigment, azurite, malachite, lead white, and yellow pigment were used in common. In the case of Sung-in Lee's portrait, seokganju and atacamite were also used. In addition, comparison with the contemporaneous portraits of gentry showed that the portrait style at the time was found in the two portraits, but the singularity was modified differently there. Based on the scientific analysis, it was decided to replicate the old color restoration for Jo-nyeon Lee's portrait while for Sung-in Lee's portrait, it was decided to replicate the phenomenon. Detailed coloring techniques were presented by supplementing the expression techniques that are difficult to confirm visually using scientific data. In addition, by measuring the chromaticity of representative positions in the portrait for each color and presenting the color reference value calculated as the average value, the current color of the artifact can be replicated and restored based on the objective data as much as possible.

Digital Restoration of Missing Parts and Production of Three-dimensional Printed Replicas the Stone Buddhas in Four Directions in Hwajeon-ri, Yesan, Korea (예산 화전리 석조사면불상의 결손부 디지털 복원 및 3차원 프린팅 복제모형 제작)

  • Lee Seungjun;Jo Younghoon;Kim Jiho;Cho Hyosik
    • Conservation Science in Museum
    • /
    • v.29
    • /
    • pp.99-110
    • /
    • 2023
  • The stone fragments that are missing from the stone cultural heritage have limited use beyond being directly fitted to identify their original position, as they are relatively heavy and bulky, and there is the further risk of secondary physical damage during manual work. Therefore, in this study, morphological relationships between the missing parts and the stone fragments were identified through digital restoration, and a three-dimensional (3D) printed replica was created for use at the exhibition for Stone Buddhas in Four Directions in Hwajeon-ri, Yesan, where 72 stone fragments had been excavated together. First, for the digital restoration, stone fragments of similar shapes were selected after the coordinates of the 3D scanning model were aligned in virtual space. In addition, the stone fragments were printed using a 3D printer to check whether they were physically related to the missing parts. Thus, the original positions of a total of nine stone fragments were identified. To utilize these research results in the exhibition, a 1:1 replica of the Stone Buddhas in Four Directions was produced using 3D printing technology, and the nine stone fragments were also restored to their original positions. The digital technology used in this study is of great importance in that it not only made up for the limitations of the direct manual method but also suggested the possibility of expanding its application to the fields of documentation, restoration, and replication of similar cultural heritage.

A Study on the Shape of the Portrait of King Taejo Using Digital Restoration (디지털 복원을 통한 태조어진太祖御眞의 형태 고찰)

  • Kwak, Eun Gyung;Sohn, Theo;Yi, Hyeon Ju
    • Journal of Conservation Science
    • /
    • v.32 no.1
    • /
    • pp.51-61
    • /
    • 2016
  • 'Eojin', king's portraits, had been produced during the Joseon dynasty. The portrait of King Taejo, the founder of the Joseon dynasty, remain at National Palace Museum of Korea and Gyeonggijeon portrait hall in Jeonju and Junwonjeon portrait hall in North Korea that has been recorded in original glass plate photo in 1911. Many replica of Eojin have been made since it is important to preserve and protect original one. In this study, the portrait of King Taejo, which is possessed by National Palace Museum of Korea, was researched for making replication standard version of the original form. It was focused on derivations of each artefacts and drawing lines those had been described on the picture including comparison among three portraits of King Taejo. Producing the replication standard version of King Taejo's portrait, the digital restoration techniques by the method of partition area scanning was applied. Accurate and precise detail result that is taken by digital imaging technique gives additional information regarding the relations among three portraits of King Taejo.

A Study on Making a Replica for Restoration of the Stone Lion Statue Excavated from Woljeong Bridge (월정교 출토 사자상 복원을 위한 모본 제작 연구)

  • Lee, Chan Young;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.31 no.2
    • /
    • pp.147-157
    • /
    • 2015
  • TExhibiting replicas of major artifacts is becoming common recently to raise their value and help the public to understand them. In Korea, more attention is paid only to appearance in creating replicas of artifacts. It is required to study reproduction technology minimizing damages to originals and applicable to massive artifacts like sculptures in the situation that replicas and artifact reproduction is increasing. To make a replica of the Stone Lion Statue excavated from Woljeong Bridge, a measured drawing and a cross section are produced based on art historical surveys using 3D scans. A non-contact reproduction method is selected. The strength of the non-contact reproduction method is that the output is detailed. Athough the non-contact method has known to be applicable only to small scale artifacts and require reprocess, it is discovered to be applicable to detailed statues like this lion statue. Therefore, this study may contribute to complement the historic authenticity of the statue as well as to raise its academic value. It also can be utilized as research material of similar artifacts'replicas and restoration.

Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system (CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가)

  • Kim, So-Ri;Kim, Chong-Myeong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

Effect of the speed sintering schedule on the marginal and internal gaps of multi-layered zirconia prothesis (급속소결이 다층 지르코니아 치과보철물의 변연 및 내면 적합도에 미치는 영향)

  • Kim, Se-Yeon;Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.44 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: The purpose of this in vitro study is to evaluate the clinical acceptability of the marginal discrepancies and internal spacing of multi-layered zirconia prothesis by speed sintering. Methods: The two specimen types come from the same manufacturer but differ in the ingredients in layered zirconia and indication, that is anterior and posterior. The designs of both specimens were full contour crowns, and a total of 20 pieces were repeatedly fabricated, 10 for each group. The specimens were divided into two subgroups (n=10) and sintered with various total times (4 hours, 8 hours) at the maximum temperature (1,530℃). The gap between the two groups of multi-layered zirconia prostheses was measured using a silicone replica technique of 2D analysis method. The independent sample t-test was then used to compare and analyze the data obtained from the two groups (α=0.05). Results: The marginal and internal gap was superior in the 8-hour compared to the 4-hour group, and the results exhibited significant differences (p<0.05). All specimens showed that using the speed sintering schedule does not exceed the clinically permitted value of 120 ㎛, meaning zirconia prothesis using the speed sintering was adequate. Conclusion: The sintering condition is shown to affect the marginal and internal gaps of multi-layered zirconia restoration.