• Title/Summary/Keyword: Repeatability coefficient

Search Result 73, Processing Time 0.033 seconds

A Study on the Morphological Analysis of Sperm (정자의 형태학적 특성 분석에 관한 연구)

  • Paick, Jae-Seung;Jeon, Seong-Soo;Kim, Soo-Woong;Yi, Won-Jin;Park, Kwang-Suk
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.2
    • /
    • pp.153-165
    • /
    • 1997
  • In male reproducible health, fertility and IVF (in-vitro fertilization), semen analysis has been most important. Semen analysis can be divided into concentration, motional and morphological analysis of sperm. The existing method which was developed earlier to analyze semen concentrated on the sperm motility analysis. To provide more useful and precise solutions for clinical problems such as infertility, semen analysis must include sperm morphological analysis. But the traditional tools for semen analysis are subjective, imprecise, inaccurate, difficult to standardize, and difficult to reproduce. Therefore, with the help of development of microcomputers and image processing techniques, we developed a new sperm morphology analyzer to overcome these problems. In this study the agreement on percent normal morphology was studied between different observers and a computerized sperm morphology analyzer on a slide-by-slide basis using strict criteria. Slides from 30 different patients from the SNUH andrology laboratory were selected randomly. Microscopic fields and sperm cells were chosen randomly and percent normal morphology was recorded. The ability of sperm morphology analyzer to repeat the same reading for normal and abnormal cells was studied. The results showed that there was no significant bias between two experienced observers. The limits of agreement were 4.1%${\sim}$-3.8%. The Pearson correlation coefficient between readers was 0.79. Between the manual and sperm morphology analyzer, the same findings were reported. In this experiments the slides were stained by two different methods, PAP and Diff-Quik staining methods. The limits of agreement were 7.2%${\sim}$-5.7% and 6.0%${\sim}$-6.3%, respectively. The Pearson correlation coefficients ware 0.76 and 0.91, respectively. The limits of agreement was tighter below 20% normal forms. In the experiments of repeatability, 52 cells stained by PAP and Diff-Quik staining methods were analyzed three times in succession. Estimating pairwise agreement, the kappa statistic for the pairs were 0.76, 0.81, 0.86, and 0.75, 0.88, 0.88 respectively. In this study it was shown that there was good agreement between manual and computerized assessment of normal and abnormal cells. The repeatability and agreement per slide of computerized sperm morphology analyzer was excellent. The computer's ability to classify normal morphology per slide is promising. Based on results obtained, this system can be of clinical value both in andrology laboratories and IVF units.

  • PDF

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor (토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가)

  • Jung, Chang Jin;Jo, Jung Hee;Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

Wind Tunnel Test for the Propeller Performance of the High Altitude UAV (고고도 무인기용 프로펠러 성능특성 풍동시험)

  • Cho, Teahwan;Kim, Yangwon;Park, Donghun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.189-196
    • /
    • 2018
  • Propeller performance measurement system for high altitude UAV was designed and applied to the wind tunnel test for 2 propeller models with a diameter around 1 m. Mechanical power of the propeller was directly measured by using the torque sensor installed on the rotating axis. The thrust of whole operation body including the propeller was measured by thrust road cell. The guide rail system was suggested to reduce the weight influence of operation body on the thrust road cell. The influence of each measured variables on the aerodynamic coefficients was studied with the repeatability and uncertainty analysis. This analysis result shows that the accuracies of the road cell and the wind velocity were major factors for the thrust coefficient. Propeller performance with typical RPM was measured with various wind speeds and the test results was summarized by performance coefficients for 5 different RPM.

Study on Calibration Methods of Discharge Coefficient of Sonic Nozzles using Constant Volume Flow Meter

  • Jeong, Wan-Seop;Sin, Jin-Hyeon;Gang, Sang-Baek;Park, Gyeong-Am;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.17-17
    • /
    • 2010
  • This paper address technical issues in calibrating discharge coefficients of sonic nozzles used to measure the volume flow rate of low vacuum dry pumps. The first challenging issue comes from the technical limit that their calibration results available from the flow measurement standard laboratories do not fully cover the low vacuum measurement range although the use of sonic nozzles for precision measurement of gas flow has been well established in NMIs. The second is to make an ultra low flow sonic nozzlesufficient to measure the throughput range of 0.01 mbar-l/s. Those small-sized sonic nozzles do not only achieve the noble stability and repeatability of gas flow but also minimize effects of the fluctuation of down stream pressures for the measurement of the volume flow rate of vacuum pumps. These distinctive properties of sonic nozzles are exploited to measure the pumping speed of low vacuum dry pumps widely used in the vacuum-related academic and industrial sectors. Sonic nozzles have been standard devices for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two small-sized sonic nozzles of diameter 0.03 mm and 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter (CVFM) readily set up in the Vacuum center of KRISS was used to calibrate the discharge coefficients of the machined nozzles. The calibration results were shown to determine them within the 3% measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process. Both calibrated sonic nozzles are demonstrated to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of low vacuum dry pumps in the semiconductor and flat display processes.

  • PDF

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF

The Quantitative HPLC-PDA Method for Recombinant Interferon Alpha Analysis (유전자재조합 인터페론 알파의 HPLC-PDA에 의한 함량분석)

  • Kim, Gi-Hyun;Park, Ji-Eun;Paek, Seung-Kwan;Kim, Choon-Mi;Hong, Seung-Hwa;Lee, Hwa-Joung;Sohn, Yeo-Won
    • YAKHAK HOEJI
    • /
    • v.53 no.3
    • /
    • pp.101-106
    • /
    • 2009
  • Recombinant interferon alpha-2a is an active formula for the treatment of various cancer cells like malignant melanoma and a variety of virus infection diseases like acute or chronic hepatitis. The bioassay system based on the measurement of virus inhibitory activity by interferon has been used for interferon analysis with low repeatability. Here, we developed the HPLC assay to measure reproducibly interferon alpha-2a protein content which is replaceable to the reported bioassay. This method separated interferon alpha-2a from its oxidized forms and human serum albumin used as excipients. The regression coefficient using interferon alpha-2a EP CRS is more than 0.9 in the range from 5 ${\mu}g/ml$ to 200 ${\mu}g/ml$. The recovery result in the range from 15 ${\mu}g/ml$ to 60 ${\mu}g/ml$ is $97{\sim}104%$ and the precision is $0.2{\sim}1.7%$. The interferon alpha contents of 5 products are about 30 ${\mu}g/ml$.

Measurements of Thermal Expansion Coefficients in GRP Pipe (GRP 복합관의 열팽창계수 측정)

  • Oh, Jin-Oh;Yoon, Sung-Ho
    • Composites Research
    • /
    • v.25 no.1
    • /
    • pp.26-30
    • /
    • 2012
  • This study was focused on the measurement of thermal expansion coefficients for GRP pipe through strain gage circuits. First of all, thermal expansion coefficients of aluminum beam were measured to examine the validity of the suggested method by using various types of strain gage circuits. Thermal expansion coefficients of GRP pipes along axial and hoop directions were measured to investigate the effect of the location of strain gages, number of repeated measurements, and strain gage types with different thermal expansion coefficients on the thermal strains and the repeatability of measured results. According to the results, thermal expansion coefficients of GRP pipes along hoop direction were lower than those along axial direction due to the constraint effect of reinforced glass fibers on thermal strains along hoop direction. As measurements were repeated, thermal expansion coefficients of GRP pipes were slightly increased, but the degree of increase became smaller. Finally, the same thermal expansion coefficients were obtained irrespective of different types of strain gages with different thermal expansion coefficients if thermal strains of strain gages were compensated by using reference compensation specimen.

Analysis of Geosmin and 2-MIB in Water by Stir Bar Sorptive Extraction (SBSE) and GC/MS (교반막대추출법(SBSE)과 GC/MS를 이용한 수중의 Geosmin과 2-MIB의 분석)

  • Lee, Hwa-Ja;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.64-69
    • /
    • 2009
  • Musty and earth odors caused by geosmin and 2-MIB are the major complaints from the drinking water consumers. Therefore, early detection of geosmin and 2-MIB is the key to prevent off-flavor occurrence. In this study, a rapid method using stir bar sorptive extraction (SBSE) in combination with the GC/MS was investigated to analyze geosmin and 2-MIB in water. The SBSE method, a solventless extraction technique, was optimized and then applied to the analysis of geosmin and 2-MIB in water. The SBSE technique was found to be a simple and fast procedure that allows many samples to be extracted simultaneously using very small volume (10~20 mL). In addition, the SBSE method offered high recovery and good linear regression coefficient for the geosmin and 2-MIB. The good repeatability of this method can be deduced from the low RSD (7.2~7.6%) at 10 ng/L for geosmin and 2-MIB. The limit of detection was determined 1~2 ng/L and the limit of quantitation was 3~6 ng/L. Above all, the SBSE method proved to be a very practical technique for the analysis of geosmin and 2-MIB in water.

Genetic characterization and population structure of six brown layer pure lines using microsatellite markers

  • Karsli, Taki;Balcioglu, Murat Soner
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.1
    • /
    • pp.49-57
    • /
    • 2019
  • Objective: The first stage in both breeding and programs for the conservation of genetic resources are the identification of genetic diversity in the relevant population. The aim of the present study is to identify genetic diversity of six brown layer pure chicken lines (Rhode Island Red [RIRI, RIRII], Barred Rock [BARI, BARII], Columbian Rock [COL], and line 54 [L-54]) with microsatellite markers. Furthermore, the study aims to employ its findings to discuss the possibilities for the conservation and sustainable use of these lines that have been bred as closed populations for a long time. Methods: In the present study, a total number of 180 samples belonging to RIRI (n = 30), RIRII (n = 30), BARI (n = 30), BARII (n = 30), L-54 (n = 30), and COL (n = 30) lines were genotyped using 22 microsatellite loci. Microsatellite markers are extremely useful tools in the identification of genetic diversity since they are distributed throughout the eukaryotic genome in multitudes, demonstrate co-dominant inheritance and they feature a high rate of polymorphism and repeatability. Results: In this study, we found all loci to be polymorphic and identified the average number of alleles per locus to be in the range between 4.41 (BARI) and 5.45 (RIRI); the observed heterozygosity to be in the range between 0.31 (RIRII) and 0.50 (BARII); and $F_{IS}$ (inbreeding coefficient) values in the range between 0.16 (L-54) and 0.46 (RIRII). The $F_{IS}$ values obtained in this context points out to a deviation from Hardy-Weinberg equilibrium due to heterozygote deficiency in six different populations. The Neighbour-Joining tree, Factorial Correspondence Analysis and STRUCTURE clustering analyzes showed that six brown layer lines were separated according to their genetic origins. Conclusion: The results obtained from the study indicate a medium level of genetic diversity, high level inbreeding in chicken lines and high level genetic differentiation between chicken lines.