• Title/Summary/Keyword: Repeatability coefficient

Search Result 73, Processing Time 0.032 seconds

Optimization of Ascorbic Acid Extraction from Rugosa Rose (Rosa rugosa Thunb.) Fruit Using Response Surface Methodology and Validation of the Analytical Method

  • UM, Min;KIM, Ji-Woo;LEE, Jae-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.364-375
    • /
    • 2020
  • In this study, ultrasound-assisted extraction was performed to extract ascorbic acid from rugosa rose (Rosa rugosa Thunb.) fruit. The optimal conditions were investigated by response surface methodology, using two variable including reaction time (16-44 min) and temperature (16-44℃). The ascorbic acid extraction was sensitive to the reaction time rather than the reaction temperature, and the optimal conditions for ascorbic acid extraction were 25℃ and 30 min. Ascorbic acid and gallic acid in the rugosa rose fruit extract were completely separated by HPLC, with a resolution factor of over 1.5 between the two. The correlation coefficient of the ascorbic acid was 0.999 in a linearity test for 50-150 ㎍/mL concentration of extract. The limit of detection and limit of quantification values were 0.16 ㎍/mL and 29.89 ㎍/mL, respectively. The relative standard deviations (RSD) for repeatability and reproducibility were determined, and each RSD showed good precision at less than 5% (N=6).

A Study on Slamming Impact Pressure (슬래밍 충격 압력에 대한 연구)

  • Park, Jun-Soo;Oh, Seung-Hoon;Kwon, Sun-Hong;Chung, Jang-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.67-73
    • /
    • 2009
  • This study presents the results of a slamming experiment using a pneumatic cylinder. The employment of the pneumatic cylinder showed a relatively good repeatability when the results were compared with those of other slamming devices. The experiment was done for various incident angles. An air pocket was believed to cause a reduction in the magnitude of the impact pressure with an incident angle of $0^{\circ}$ for the water entry. A high speed camera was used in an attempt to locate the time of the contact between the bottom of the specimen and the free surface. It seemed that the maximum pressure occurred before the water contacted the bottom of the specimen.

Fabrication and Analysis of Characteristics of PRT using High-fine Laser Trimming Technology (고정밀 레이저 가공 기술을 이용한 PRT 제작 및 특성 분석)

  • 노상수;서정환;정귀상;김광호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.46-52
    • /
    • 2003
  • In this paper, we fabricated PRT(platinum resistance thermometers) with the trimming technology using high fine laser system. U. V.(wavelength: 355nm) laser was mainly used for adjusting Pt thin films resistors to 100Ω at 0$^{\circ}C$. Internationally, the accepted A-class tolerance of temperature sensor is ${\pm}$0.06Ω at 0$^{\circ}C$. according to DIN EN 60751. The width of trimmed lines was about 10$\mu\textrm{m}$ and the best trimming conditions of Pt thin films were power : 37mW, frequency : 200Hz and bite size:1.5$\mu\textrm{m}$. And 96 resistors, fabricated by photolithography and etching process, have 79∼90Ω and 91∼102Ω as the proportion of 45.7% and 57.3%, respectively. As result of sitting Pt thin films resistors to the target value(109.73Ω at 25$^{\circ}C$), 82.3% of all resistors had the tolerance within ${\pm}$0.03Ω and the others(17.7%) were within ${\pm}$0.06Ω of A-class tolerance. The PRTs which wore fabricated in this research had excellent characteristics as follows; high accuracy, international standard TCR(temperature coefficient of resistance) value, long-term stability, wide temperature range, good linearity and repeatability, rapid response time, etc.

Performance Characteristic of the β-Human Chorionic Gonadotropin Assay on the Access 2 for Its Use in Doping Control

  • Kang, Min-Jung;Lee, Hye-Im;Shin, Sang-Mi;Yoo, Hye-Hyun;Kwon, Oh-Seung;Jin, Chang-Bae;Chung, Bong-Chul
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2889-2892
    • /
    • 2010
  • The objective of this study was to validate performance characteristics of the Access 2 (Beckman coulter) system for hCG assays for use as a confirmation test for doping control. The Access 2 assay was linear up to 500 IU/L. The correlation coefficient was higher than 0.999, and the sensitivity of the linearity was 0.82. There were no false positive or false negative cases. LOD was 0.59 IU/L. The method was robust when performed by different people. Repeatability and reproducibility were below 7%. We compared reproducibility and recoveries of Access 2 and Elecsys 2010. Access 2 demonstrated higher reproducibility than Elecsys 2010. Recoveries (accuracy) of Access 2 were between 85 and 105%. Recoveries for Elecsys 2010 were between 91 and 104%.

ELISA Validation for anti-PA Antibody Titer Measurements (항-보호항원 항체의 역가 측정을 위한 효소면역측정법 밸리데이션)

  • Kim, Yu-Gene
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.478-485
    • /
    • 2010
  • The vaccine is biological pretreatment that improves immunity to a particular disease. We can get immunity from producing antibody with injection antigen which has ability to defense against the disease. The ELISA is the most widely used method to measure antibody titer. We have developed and performed validation of ELISA according to the guideline of KFDA and ICH. In this paper, we have verified ELISA method is an excellent method to measure the titer of anti-PA antibody. We have constructed recombinant protective antigen among anthrax toxins and used as antigen of ELISA. In this validation, we have evaluated precision (repeatability, interlaboratory precision), specificity, linearity(range) and LOD, which are validation articles suggested by guideline. Inter-person precision was replaced with inter-laboratory precision. From the results, we have confirmed high precision in all experiments with CV under 20%.

Temperature sensor without reference resistor by indium tin oxide and molybdenum (인듐틴옥사이드와 몰리브데늄을 이용한 외부 기준 저항이 필요 없는 온도센서)

  • Jeon, Ho-Sik;Bae, Byung-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.483-489
    • /
    • 2010
  • Display quality depends on panel temperatures. To compensate it, temperature sensor was integrated on the panel. The conventional temperature sensor integrated on the panel needs external reference resistor. Since the resistance of external resistor can vary according to the variation of the environment temperature, the conventional temperature sensor can make error in temperature sensing. The environmental temperatures can change by the back light unit, driving circuits or chips. In this paper, we proposed a integrated temperature sensor on display panel which does not need external reference resister. Instead of external reference resistor, we used two materials which have different temperature coefficient in resistivity. They are connected serially and the output voltage was measured at the point of connection with the applied voltage to both ends. The proposed sensor was fabricated with indium tin oxide(ITO), and Mo metal electrode temperature sensor which were connected serially. We verified the temperature senor by the measurements of sensitivity, lineality, hysteresis, repeatability, stability, and accuracy.

Establishment of HPLC-UV Analysis Method Validation for Simultaneous Analysis of Standard Compounds of Oplopanax elatus Nakai Stem (HPLC-UV를 이용한 땃두릅나무 줄기의 지표 성분 동시 분석법 확립)

  • Yoo, Nam Ho;Kwon, Yongsoo;Kim, Myong Jo
    • Korean Journal of Pharmacognosy
    • /
    • v.50 no.2
    • /
    • pp.133-140
    • /
    • 2019
  • In our previous study, we found uracil, adenosine, protocatechuic acid, syringin (eleutheroside B) and scoparone (6, 7-dimethoxycoumarin) in the Oplopanax elatus Nakai Stem. High-performance liquid chromatography (HPLC) -UV was used to quality and quantify the internal marker compounds in the O. elatus extract after validation of method with linearity, limit of detection (LOD), limit of quantitation (LOQ), accuracy and precision. The specificity assessment visually confirmed that the substance was detected without the introduction of other substances. The established method showed high linearity of the calibration curve and coefficient of correlation ($R^2$) of over the 0.999. HPLC was reported as five standard compounds equivalent using the following linear equation based on the calibration curve. The accuracy of measurement was 84.34 ~ 119.74% and the relative standard deviation (RSD) value was 0.28 ~ 1.60%. In addition, our established method showed high repeatability. The RSD value was 1.10 ~ 6.81%. So, we found the amount of the internal marker compounds in the O. elatus extract. These results demonstrated that can be used to quality evaluation of the O. elatus.

A new merging-zone flow injection system for the quantification of ferrous and ferric ions in aqueous solution and sludge of wastewater

  • Farhood, Ahmed Saleh;Taha, Dakhil Nassir
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.218-227
    • /
    • 2022
  • A simple and fast throughput flow injection (FI) system with a merging-zone technique was designed to determine ferrous and ferric in an aqueous solution. The method is based on the direct reaction of ferrous with a Bathophenanthroline reagent (Bphen) in acidic media. The forming red complex absorbs light at 533 nm. All conditions of the flow injection system were investigated. The analytical curve of ferrous was linear in the range of 0.07 to 4 mg/L with an r2 value of 0.9968. The detection and quantification limits were 0.02 and 0.04 mg/L, respectively. The molar absorptivity and Sandell's sensitivity were 4.0577 × 106 L/mol cm and 25 × 10-5 ㎍/cm2, respectively. The homemade valve was low-cost with high repeatability (n = 7) at an RSD of 1.26 % and zero dead volume. The values of the dispersion coefficient were 2.318, 2.022, and 1.636 for the concentrations of 0.2, 1, and 3 mg/L, respectively. The analysis throughput of the designed flow injection unit was 57 sample per hour.

Performance Evaluation of Domestic Prototype Dose Area Product Meter SFT-1 (국산 프로토타입 면적선량계 SFT-1의 성능평가)

  • Lee, Ho-Sun;Han, Seong-Gyu;Roh, Young-Hoon;Lim, Hyun-Jong;Kim, Jung-Min;Kim, Jong-Uk;Chae, Hyun-Sik;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.435-441
    • /
    • 2016
  • The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R&BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatability coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria.

Development of Analytical Methods of Hyperoside from Rosa canina L. (Rosa canina L. 중 hyperoside의 시험법 개발 연구)

  • Oh, Jae Myoung;Lee, Hwa Jung;Bahn, Kyeong Nyeo;Seo, Il Won;Lee, Young Joo;Lee, Jin Hee;Park, Ji Min;Kang, Tae Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.173-177
    • /
    • 2015
  • Rosa canina L. is health functional food materials that can help to temporarily relieve symptoms of arthritis. This study has been conducted to develop and validate analytical methods for hyperoside of Rosa canina L.. Methods based on HPLC with ultraviolet detection (UVD) were established through instrumental analytical conditions, and the examination of data, such as domestic and foreign reliable methods and journals. HPLC UVD analysis using Capcell Pak $C_{18}$ MG II column at 353 nm was determined on test through the column, mobile phase. The validation has been performed on the method to determine linearity, accuracy, limits of quantification (LOQ) and repeatability for hyperoside. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.999, and the LOQ was $0.393{\mu}g/mL$. Relative standard deviation (RSD) values of data from repeatability precision was between 0.6 and 2.6%. Recovery rate test at hyperoside scored between 98 and 99%. These results indicate that the established HPLC method is very useful for the determination of hyperoside in Rosa canina L. to develop a health functional material.