• Title/Summary/Keyword: Repeatability coefficient

Search Result 73, Processing Time 0.028 seconds

Repeatability of a Multi-segment Foot Model with a 15-Marker Set in Normal Children

  • Kim, Eo Jin;Shin, Hyuk Soo;Lee, Jae Hee;Kyung, Min Gyu;Yoo, Hyo Jeong;Yoo, Won Joon;Lee, Dong Yeon
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.484-490
    • /
    • 2018
  • Background: The use of three-dimensional multi-segment foot models (3D MFMs) is increasing since they have superior ability to illustrate the effect of foot and ankle pathologies on intersegmental motion of the foot compared to single-segment foot model gait analysis. However, validation of the repeatability of the 3D MFMs is important for their clinical use. Although many MFMs have been validated in normal adults, research on MFM repeatability in children is lacking. The purpose of this study is to validate the intrasession, intersession, and interrater repeatability of an MFM with a 15-marker set (DuPont foot model) in healthy children. Methods: The study included 20 feet of 20 healthy children (10 boys and 10 girls). We divided the participants into two groups of 10 each. One group was tested by the same operator in each test (intersession analysis), while the other group was tested by a different operator in each test (interrater analysis). The multiple correlation coefficient (CMC) and intraclass correlation coefficient (ICC) were calculated to assess repeatability. The difference between the two sessions of each group was assessed at each time point of gait cycle. Results: The intrasession CMC and ICC values of all parameters showed excellent or very good repeatability. The intersession CMC of many parameters showed good or better repeatability. Interrater CMC and ICC values were generally lower for all parameters than intrasession and intersession. The mean gaps of all parameters were generally similar to those of the previous study. Conclusions: We demonstrated that 3D MFM using a 15-marker set had high intrasession, intersession, and interrater repeatability in the assessment of foot motion in healthy children but recommend some caution in interpreting the hindfoot parameters.

A Preliminary Study on the Repeatability of Facial Feature Variables Used in the Sasang Constitutional Diagnosis (체질진단에 활용되는 안면 특징 변수들의 반복성에 대한 예비 연구)

  • Roh, Min-Yeong;Kim, Jong-Yeol;Do, Jun-Hyeong
    • Journal of Sasang Constitutional Medicine
    • /
    • v.29 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • Objectives Facial features can be utilized as an indicator of Korean medical diagnosis. They are often measured by using the diagnostic device for an objective diagnosis. Accordingly, it is necessary to verify the reliability of the features which are obtained from the device for the accurate diagnosis. In this study, we attempt to evaluate the repeatability of facial feature variables using the Sasang Constitutional Analysis Tool(SCAT) for the Sasang Constitutional face diagnosis. Methods Facial pictures of two subjects were taken 24 times respectively for two days according to a standard guideline. In order to evaluate the repeatability, the coefficient of variation was calculated for the facial features extracted from frontal and profile images. Results The coefficient of variation was less than 10% in most of the facial features except the upper lip, trichion, and chins related features. Conclusions It was confirmed that the coefficient of variation was small in most of the features which enables the objective and reliable analysis of face. However, some features showed the low reliability because the location of facial landmarks related to them is ambiguous. In order to solve the problem, a clear basis for the location discussion is required.

Sex differences in repeatability of measurement for hamstring strength during maximal voluntary contractions (최대 수의적 수축 동안 뒤넙다리근 근력 반복성의 남녀 차이)

  • Lim, Woo Taek
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.1
    • /
    • pp.9-17
    • /
    • 2020
  • Background: This study aimed to examine the repeatability of hamstring strength during maximal voluntary contractions (MVCs) and to examine the sex difference. Design: Quasi-experiment design. Methods: The study recruited 23 healthy young individuals as participants. Hamstring flexibility was measured before and after MVCs by active knee extension test. Five trials of MVCs were performed, and hip extension forces were measured using a strain gauge during MVCs. Repeatability was confirmed by intraclass correlation coefficient (ICC) and coefficient of variation, and the difference between male and female participants was confirmed by independent samples t-test. Results: The forces measured during MVCs were significantly different between men and women over five trials. We observed the minimum and maximum force production at the first and fifth trial of MVCs in both men and women. Excellent to moderate reliability of the hamstring strength during MVCs was found in men (ICC range, 0.70-0.98) and women (ICC range, 0.66-0.90). There was no significant difference in hamstring flexibility between men and women. Conclusion: In clinical settings, we recommend excluding the first trial of MVCs in both men and women. Additionally, performing at least three trials of MVCs would be useful to improve the reliability of the baseline measures in women.

Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation

  • Moon, Byeong-Yeon;Park, Sun-Young;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.418-424
    • /
    • 2012
  • The purpose of this study was to assess repeatability and reliability of a new phoria test as compared to established phoria tests and to assess the possibility of mobile or online testing using the auto-flashed presentation. Near dissociated phoria was measured using the von Graefe method, the Howell card test, the modified Thorington test, and a new dichromatic card test (Red-Blue Phoria card test; RBP card test) on 109 subjects. The inter-examiner difference and test-retest difference were calculated. With the auto-flashed presentation of the RBP card test, near dissociated phoria was measured and the intraclass correlation coefficient and test-retest repeatability was assessed on 26 subjects. The variation in inter-examiner repeatability was the smallest for the modified Thorington test (+3.1/-2.6). The RBP card test was +3.0/-3.1, the Howell card test was +3.5/-2.7, and the von Graefe test was +6.2/-6.0. The variation in test-retest repeatability was the smallest for the RBP card test (+0.4/-1.4). The modified Thorington test was +1.3/-1.3, the Howell card test was +1.27/-1.45, and the von Graefe test was +1.59/-2.20. The ICC was 0.919 for the auto-flashed presentation of the RBP card test. The RBP card test is considered a highly repeatable method clinically and can be made a useful application for testing in mobile or online.

A Study on the Repeatability of Fabric Drape (직물 드레이프 재현성에 관한 연구)

  • Jeong, Young-Jin;Min, Byung-Ghyl;Lee, Joon-Seok
    • Fashion & Textile Research Journal
    • /
    • v.1 no.1
    • /
    • pp.50-55
    • /
    • 1999
  • The repeatability of fabric drape was studied. Two methods for draping were used and the relation between node distributions was investigated using statistical analysis. With this, the relationship between node distribution and fabric mechanical properties was studied. The repeated measurements showed that there was no evidence that fabric has intrinsic node number and the mechanical properties influence on the number of nodes.

  • PDF

Repeatability of the Measurement of Electrical Taste Detection Thresholds in Healthy Young Females

  • Hee Noh;Yeong-Gwan Im;Byung-Gook Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.4
    • /
    • pp.144-151
    • /
    • 2023
  • Purpose: The aim of this study was to assess the repeatability of the electrical measurement of taste detection on different dates and in different sessions in healthy young females. Methods: The sites of electrical stimulation were the tip of the tongue, the posterolateral border of the tongue and the soft palate on the right side unilaterally. The measurements were repeated over three consecutive days, three sessions per day and three times for each session in seventeen healthy females. The repeatability of the measurement was assessed by the intraclass correlation coefficient (ICC). Results: In the dB unit, the ICC of the tip of the tongue and the soft palate was good (61.03 and 66.03, respectively); however, the lateral border of the tongue was a little lower (58.07). In the ㎂ unit, all three test sites had poor ICC. Variability was more significantly associated with the subject factor than with other factors such as trials, sessions and days in dB and ㎂ units. Conclusions: Electrogustometry, which measures electrical taste detection thresholds in the dB unit, is repeatable and acceptable for clinical use in assessing taste function in healthy young females.

A Clinical Study on the Repeatability and Reproducibility of Portable Ryodoraku Device (포터블 양도락의 반복성.재현성에 대한 임상 연구)

  • Lee, Ji In;Ko, Seong Cheol;Song, Ho Sueb
    • Journal of Acupuncture Research
    • /
    • v.30 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the repeatability and reproducibility of the Ryodoraku acupuncture device. For such device to be accepted as a good apparatus for clinical diagnosis, the score it provides should be stable no matter who measure it or when it is measured, assuming all other conditions equal. Materials and Methods : Three oriental medical doctors who were well trained and fully aware of the usage of the Ryodoraku acupuncture device examined ten randomly selected patients three times. Each doctor measured the Ryodoraku scores three times from each of the 10 selected patients. Three doctors were involved in this experiment to investigate the reproducibility and each of them measured the Ryodoraku scores three times from each patient to investigate the repeatability. Data was analyzed with Friedman test, Spearman correlation test, and intra-class correlation coefficient(ICC) in SPSS ver. 18. Results : 1. The Friedman test showed that there is no statistically significant difference between the 1st, 2nd and 3rd Ryodoraku scores measured by the same examiner. It indicates that the Ryodoraku acupuncture device provides the repeatability. 2. Spearman correlation test confirmed the results obtained by the Fiedman test by showing that there exists a strong positive correlation between the three Ryodoraku scores measured by the same examiner. 3. A very high ICC among the three examiner assured that the Ryodoraku acupuncture device achieves the reproducibility. Conclusions : The Ryodoraku acupuncture device achieves the repeatability and reproducibility. However, we still recommend that a doctor trained to a certain level use the Device to carry out the diagnosis. Also, to improve the device in terms of Reproducibility even more, it should be considered to provide a manual for the exact usage.

An Experimental Study on Slamming Phenomenon by Forced Impact (강제 입수에 의한 슬래밍 현상에 관한 실험적 연구)

  • Nahm, Jong-Ou;Kang, Hyo-Dong;Chung, Jang-Young;Kwon, Sun-Hong;Choi, Han-Suk
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.1 s.74
    • /
    • pp.40-44
    • /
    • 2007
  • This paper presents the experimental results on slamming phenomenon. The air pressure cylinder was used to ensure repeatability of the impact. The results showed that the adopted experimental technique was excellent in terms of repeatability, compared to that of the free drop tests. The pressure time histories, magnitude of peak pressure and the behavior of jetspray were obtained. The flat specimen was tested for various incident angles. To estimate the incident speed of the specimen, a high-speed camera was used. The high-speed camera was also a useful tool in understanding the behavior.

Development and Evaluation of Repeatability of the Integrated Constitutional Diagnosis System (통합 체질진단 시스템 개발 및 반복성 평가)

  • Jeon, Young-Ju;Kim, Jang-Woong;Kim, Jae-Uk;Bae, Jang-Han;Kim, Jong-Yeol;Kim, Keun-Ho
    • Journal of Sasang Constitutional Medicine
    • /
    • v.24 no.3
    • /
    • pp.34-41
    • /
    • 2012
  • Objectives In this study, we developed a mock-up of the system for Sasang Constitutional (SC) diagnosis. This system consists of 5 devices which are the face analyzer, the voice analyzer, the skin analyzer, the pulse analyzer, and the computer-based questionnaire. Our goal is to evaluate the repeatability of the system. Methods Each device is capable of classifying SC types. The classification probability of the integrated system for the SC types was obtained by summing the probability from each device. For evaluating the repeatability of the system, we collected data for 5 subjects, and repeated the measurement three times for each individual. The average and standard deviation were used for calculating the Coefficient of Variation. Results The results showed that the repeatability of the classification probability of the integrated system is about 8%, which implies the system is repeatable. Conclusions To increase usability of this system, it is desirable for the system to offer information on health condition of the user. The integrated constitutional diagnosis system will be upgraded to complement the convenience and to develop the diagnostic algorithm for the user's health condition.

PERFORMANCE TEST FOR A PDS MICRODENSITOMETER MODEL 1010GMS

  • Hong, S.S.;Paek, W.G.;Lee, S.G.
    • Journal of The Korean Astronomical Society
    • /
    • v.25 no.1
    • /
    • pp.23-46
    • /
    • 1992
  • The electrical, mechanical and optical capabilities have been tested of the microdensitometer PDS 1010GMS at the Korea Astronomy Observatory. The highest stage of scan speed 255 csu (conventional speed unit) is measured to be 47 mm/s. At this speed the position is displaced by $4{\mu}m$ to the direction of scanning and the density is underestimated by $0.4{\sim}0.7D$. Standard deviation in the measured density is proportional to $A^{-0.46}$, where A is the area of scan aperture. The accuracy of position repeatability is ${\pm}1{\mu}m$, and that of density repeatability is ${\pm}(0.003{\sim}0.03)D$. Callier coefficient is determined to be 1.37; the semispecular density is directly proportional to the diffuse density up to 3.5D. Because the logarithmic amplifier has a finite response time, the densities measured at high scan speeds are underestimated to the degree that speeds higher than 200 csu are inadequate for making an accurate astronomical photometry. After power is on, an about 5 hour period of warming is required to stabilize the system electrically and mechanically as well. On the basis of this performance test, we have determined the followings as the optimum scan parameters for the astronomical photometry: For the scan aperture $10\;\sim\;20{\mu}m$ is optimal, and for the scan speed. $20\;{\sim}\;50$ csu is appropriate. These parameter values are chosen in such a way that they may keep the density repeatability within ${\pm}0.01D$, the position displacement under $1{\mu}m$, and the density underestimation below 0.1D even in high density regions.

  • PDF