• Title/Summary/Keyword: Repair technique

Search Result 680, Processing Time 0.02 seconds

Change of Proximal Descending Aortic False Lumen after Conventional Repair of Acute Type I Dissection: Is It Always Unfavorable?

  • Kim, Sue Hyun;Kim, Jun Sung;Shin, Yoon Cheol;Kim, Dong Jung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.48 no.4
    • /
    • pp.238-245
    • /
    • 2015
  • Background: Some patients show favorable changes in the descending aortic false lumen after conventional repair of acute type A dissection, although the incidence of favorable changes has been reported to be low. We aimed to investigate the incidence of positive postoperative changes in the false lumen and the factors associated with positive outcomes. Methods: In 63 patients who underwent surgery for type A acute dissection as well as serial computed tomography (CT) scanning, morphological parameters were compared between the preoperative, early postoperative (mean interval, 5.4 days), and late CT scans (mean interval, 31.0 months) at three levels of the descending thoracic aorta. Results: In the early postoperative CT images, complete false lumen thrombosis and/or true lumen expansion at the proximal descending aorta was observed in 46% of the patients. In the late images, complete thrombosis or resolution of the proximal descending false lumen occurred in 42.9% of the patients. Multivariate analysis found that juxta-anastomotic false lumen thrombosis was predictive of favorable early changes, which were in turn predictive of continuing later improvement. Conclusion: Even after conventional repair without inserting a frozen elephant trunk, the proximal descending aortic false lumen showed positive remodeling in a substantial number of patients. We believe that the long-term prognosis of type A dissection can be improved by refining surgical technique, and particularly by avoiding large intimal tears at the anastomosis site during the initial repair.

Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics

  • Carrabba, Michele;Vichi, Alessandro;Louca, Chris;Ferrari, Marco
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.257-264
    • /
    • 2017
  • PURPOSE. To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS. A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher's Exact Test was applied to the failure analysis data. RESULTS. The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION. The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.

Arthroscopic Repair of Anterior Root Injury in Lateral Meniscus Using Suture Anchor - Case Report and Technical Note - (Suture anchor를 이용한 외측 반월판 연골 전방 뿌리 파열의 관절경적 치료 -증례 및 술기 보고-)

  • Kim, Do-Young;Yoo, Yon-Sik;Lee, Sang-Soo;Jeong, Un-Seob;Seo, Eun-Min;Park, Seung-Jae
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.41-45
    • /
    • 2011
  • As awareness of root tear of meniscus have been increased, it became necessary to have an intensive repair. Posterior horn tear, especially for a lot of repair methods and the results have been reported recently. The report of the anterior root tear has yet to be found. We recently encountered a patient with an iatrogenic meniscal subluxation caused by past experienced partial menisectomy for discoid meniscus. Thus, we repots the technique and clinical results of arthroscopic repair of subluxated lateral meniscus anterior root tear using suture anchor.

  • PDF

Clinical Outcomes of Arthroscopic Rotator Cuff Repair Using Poly Lactic-co-glycolic Acid Plus β-tricalcium Phosphate Biocomposite Suture Anchors

  • Chung, Seok Won;Oh, Kyung-Soo;Kang, Sung Jin;Yoon, Jong Pil;Kim, Joon Yub
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.22-29
    • /
    • 2018
  • Background: This study is performed to evaluate anchor-related outcomes and complications after arthroscopic rotator cuff repair using 30% ${\beta}$-tricalcium phosphate (${\beta}$-TCP) with 70% poly lactic-co-glycolic acid (PLGA) biocomposite suture anchors. Methods: A total of 78 patients (mean age, $61.3{\pm}6.9years$) who underwent arthroscopic medium-to-large full-thickness rotator cuff tear repair were enrolled. The technique employed 30% ${\beta}$-TCP with 70% PLGA biocomposite suture anchors at the medial row (38 patients, Healix $BR^{TM}$ anchor [Healix group]; 40 patients, Fixone anchor B [Fixone group]). The radiologic outcomes (including perianchor cyst formation or bone substitution) and anatomical outcomes of the healing failure rate were evaluated using magnetic resonance imaging at least 6 months after surgery, the pain visual analogue scale at 3, 6 months, and final follow-up visit, and American Shoulder and Elbow Surgeons scores at least 1 year postoperatively. Anchor-related complications were also evaluated. Results: The perianchor cyst formation incidence was similar for both groups (60.5%, Healix group; 60.0%, Fixone group; p=0.967), although severe perianchor cyst incidence was slightly lower in the Fixone group (15.0%) than in the Healix group (21.1%). There was no occurrence of anchor absorption and bone substitution. No differences were observed in the healing failure rate (13.2%, Healix group; 15.0%, Fixone group; p=0.815) and functional outcome between groups (all p>0.05). Anchor breakage occurred in 5 patients (2 Healix anchors and 3 Fixone anchors); however, there were no major anchor-related complications in either group. Conclusions: No differences were observed in the clinical outcomes of the Healix and Fixone groups, neither were there any accompanying major anchor-related complications.

The Effect of Exercise Using Grasping on Shoulder Muscle Activity and Muscle Thickness of Patients with Rotator Cuff Repair

  • Choi, Eun-Young;Choi, Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.52-58
    • /
    • 2016
  • Purpose: This study intended to mediate shoulder exercise using grasping and investigate examine how its effects on affects activities of the shoulder surrounding muscles of the shoulder and thickness of shoulder muscle to suggest effective exercise for patients with rotator cuff repair to return to daily life. Methods: This study has been done targeteding male patients more than 6 weeks after having En-masse Suture Bridge Technique as rotator cuff repair of the right shoulder, aged 40 to 55 in a medical institution located in Jeollanam-do. Experimental group I (n=15) was selected for a conducting common exercise therapy program and Experimental group II (n=15) was selected for an conducting exercise therapy program using grasping. %RVC was measured by surface electromyography and muscle thickness was measured by ultrasound before mediation to for analysisze of before and after results within group and between groups. Results: In comparison of change of %RVC, Tthere were meaningful differences in only posterior deltoid and infraspinatus in comparing a change of %RVC within experimental group I (p<0.001),. and Tthere were meaningful differences in both supraspinatus and infraspinatus in muscle thickness within experimental group I (p<0.001). In comparison of change of %RVC, Tthere were meaningful differences in anterior deltoid, posterior deltoid and infraspinatus in comparing a change of %RVC within experimental group II (p<0.05)(p<0.01) (p<0.001), and there were meaningful differences in both supraspinatus and infraspinatus in muscle thickness within experimental group II (p<0.001). In comparison of change of %RVC between groups, Tthere was a meaningful difference in only posterior deltoid in comparing a change of %RVC between groups (p<0.001). Conclusion: We found that exercise therapy using grasping has a positive effect on shoulder stability muscles such as supraspinatus muscle and infraspinatus muscle and activity of deltoid muscle.

Early and Delayed Postoperative Rehabilitation after Arthroscopic Rotator Cuff Repair: A Comparative Study of Clinical Outcomes

  • Choi, Sungwook;Seo, Kyu Bum;Shim, Seungjae;Shin, Ju Yeon;Kang, Hyunseong
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.4
    • /
    • pp.190-194
    • /
    • 2019
  • Background: The duration of immobilization after arthroscopic rotator cuff repair and the optimal time to commence rehabilitation are still the subject of ongoing debates. This study was undertaken to evaluate the functional outcome and rotator cuff healing status after arthroscopic rotator cuff repair by comparing early and delayed rehabilitation. Methods: Totally, 76 patients with small, medium, and large sized rotator cuff tears underwent arthroscopic repair using the suturebridge technique. In early rehabilitation group, 38 patients commenced passive range of motion at postoperative day 2 whereas 38 patients assigned to the delayed rehabilitation group commenced passive range of motion at postoperative week 3. At the end of the study period, clinical and functional evaluations (Constant score, the University of California, Los Angeles [UCLA] shoulder score) were carried out, subsequent to measuring the range of motion, visual analogue scale for pain, and isokinetic dynamometer test. Rotator cuff healing was confirmed by magnetic resonance imaging at least 6 months after surgery. Results: No significant difference was obtained in range of motion and visual analogue scale between both groups. Functional outcomes showed similar improvements in the Constant score (early: 67.0-88.0; delayed: 66.9-91.0; p<0.001) and the UCLA shoulder score (early: 20.3-32.3; delayed: 20.4-32.4; p<0.001). Furthermore, rotator cuff healing showed no significant differences between the groups (range, 6-15 months; average, 10.4 months). Conclusions: Delayed passive rehabilitation does not bring about superior outcomes. Therefore, early rehabilitation would be useful to help patients resume their daily lives.

Development of Crack Monitoring System for Self-healing Repair Mortar Surface Using Image Processing Technique (이미지 처리 기법을 이용한 자기치유 보수 모르타르 시공표면의 균열 모니터링 시스템 개발)

  • Oh, Sang-Hyuk;Moon, Dae-Jung;Lee, Kwang-Myong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.359-366
    • /
    • 2021
  • In this study, It was developed an monitoring cracks system based on image processing techniques in order to measure cracks, which are major damages in concrete, and to convert them into a database. The crack monitoring system consists of crack image captured equipment and a crack detection and analysis software. This system provides objective and quantitative data by replacing the conventional visual inspection. The crack detection algorithm w as verified through an indoor test using virtual cracks, and the amount of crack detection and crack width change was monitored by applying it to the self-healing repair mortar construction site. In the case of the crack width detected through image analysis, the maximum difference from the actual crack width was 0.0334mm. It was possible to detect microcracks of 0.1mm or less, and the effect of crack healing over time of the self-healing repair mortar was confirmed trough the field test.

Influence of surface treatments and repair materials on the shear bond strength of CAD/CAM provisional restorations

  • Jeong, Ki-Won;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.95-104
    • /
    • 2019
  • PURPOSE. To evaluate the effect of surface treatments and repair materials on the shear bond strength and to measure the fracture toughness of CAD/CAM provisional restoration materials. MATERIALS AND METHODS. Four CAD/CAM (3D printing: Nextdent C&B and ZMD-1000B Temporary, CAD/CAM resin block: Yamahachi PMMA disk and Huge PMMA block) and four conventional (monometacrylate: Jet and Alike, dimetacrylate: Luxatemp and Protemp 4) materials were selected to fabricate disk-shaped specimens and divided into six groups according to surface treatment (n=10). CAD/CAM materials were repaired with Jet or Luxatemp, while conventional materials were repaired with their own materials. The shear bond strength was measured by using universal testing machine. Ten rectangular column-shaped specimens for each material were fabricated to measure the fracture toughness by single edge v notched beam technique. Statistical analysis was performed by one-way ANOVA. RESULTS. The highest shear bond strength of CAD/CAM materials was achieved by SiC paper + sandblasting. It was also accomplished when repairing 3D printing materials with Luxatemp, and repairing CAD/CAM resin blocks with Jet. Yamahachi PMMA disk showed the highest fracture toughness. Nextdent C&B showed the lowest fracture toughness value but no statistically significant difference from Alike and Luxatemp (P>.05). CONCLUSION. In order to successfully repair the CAD/CAM provisional restoration, mechanical surface treatment and appropriate repair material according to the CAD/CAM material type should be selected. The CAD/CAM provisional materials have proper mechanical properties for clinical use as compared to conventional materials.

Usefulness of Inferior Turbinate Bone-Periosteal-Mucosal Composite Free Graft for Cerebrospinal Fluid Leakage (하비갑개 골-골막-점막 복합이식을 이용한 뇌척수액 유출 복원술)

  • Baek, Kwangha;Kim, Jihyung;Moon, Youngmin;Kim, Chang-Hoon;Yoon, Joo-Heon;Cho, Hyung-Ju
    • Journal of Rhinology
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2018
  • Background and Objectives: Endoscopic repair of cerebrospinal fluid (CSF) leak can avoid morbidity of open approaches and has shown a favorable success rate. Free mucosal graft is a good method, and multi-layered repair is more favorable. The inferior turbinate has been commonly utilized for the free mucosal graft, but we newly designed it as a bone-periosteal-mucosal composite graft for multilayered reconstruction. Subjects and Method: Four subjects with a skull base defect were treated with this method. The inferior turbinate was partially resected including the conchal bone and was trimmed according to defect size. Both bony parts and periosteum were preserved on the basolateral side of the mucosa as a composite graft. The graft was applied to the defect site using an overlay technique. Results: All cases were successfully repaired without any complications. Three of them had a defect size greater than 10-12 mm, and the graft stably repaired the CSF leakage. Conclusion: Endoscopic repair of CSF leakage using inferior turbinate composite graft is a simple and easy method and would be favorable for defect sizes greater than 10 mm.

Single -portal Subscapualrs tendon repair

  • Choe, Chang-Hyeok;Kim, Sin-Geun;Jang, Ho-Jin;Chae, Seong-Beom
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.179-179
    • /
    • 2008
  • For a partial tear of the subscapularis tendon, the presenting technique requires only the anterior portal for preparing the footprint and suture management, as well as the subclavian portal for placing the suture anchor and suture hook without inserting a cannula. It provides both a good angle for anchor placement and sufficient space for managing the upper portion of a subscapularis tendon tear. A spinal needle was inserted through the subclavian portal in order to identify the appropriate angle for placing the suture anchor. A 3-mm incision was made for the subclavian portal and a biosuture anchor was placed on the footprint portion of the subscapularis tendon. In order to avoid crowding, each limb of both strands of the biosuture anchor were passed through the tendon- posteromedial side first, and anterolateral side second, using a switching technique with suture hook embedded with no.1 PDS. A suture tie was applied in a reverse sequence (the lateral strand first and the medial strand second) through the anterior cannula using a sliding technique.

  • PDF