• Title/Summary/Keyword: Repair of defect

Search Result 592, Processing Time 0.023 seconds

Surgical Repair of Secundum Type Atrial Septal Defects Using Extracorporeal Circulation in 48 Patients (심방중격 결손증의 외과적 완전교정 48례 보고)

  • 서경필
    • Journal of Chest Surgery
    • /
    • v.10 no.2
    • /
    • pp.268-273
    • /
    • 1977
  • During the period from March, 1963, to November, 1977, forty-eight patients with secundum type atrial septal defects have undergone surgical repair using cardiopulmonary bypass with a pump oxygenator at the Seoul National University Hospital. Twenty-six [55 percent] of the patients were females and Twenty-two [45 percent] were males. The patients varied in age from 3 years to 51 years. We have divided secundum defects into three types. These are: 1] the high defect; 2] Ovale type defect; and 3] low defect including the defect in the area of the coronary sinus. An ovale type defect was present in forty-one cases [85 percent]. Partial anomalous pulmonary venous connections were present in two patients in the high defect group. All of the forty-eight patients had had right heart catheterization before operation. The pulmonary to systemic flow ratio [Qp/Qs] was determined in our 38 patients. The Qp/Qs was less than 1.5/1 in only five of the 38 patients. Among the 33 patients with moderate and severe left-to-right shunts [Qp/Qs 1.6-3.5/1], the systolic pulmonary artery pressures. ranged from 30 to 80 mm Hg. Large left-to-right shunts [Qp/Qs>3.6/1] were present in 13 patients. The postoperative complications occurred in 13 patients [27. 1 percent]. Postoperative wound infections were the most frequent complications being present in 6 patients [12.5%]. Forty-six of the patients with secundum atrial septal defects survived surgical repair of their defects. Thus the hospital mortality of surgery was 4.2 percent. The causes of death in the early postoperative period were: 1] low cardiac output syndrome related to severe pulmonary hypertension in one case; and 2] postoperative several bleeding in one case.

  • PDF

Surgical Outcomes of Congenital Atrial Septal Defect Using da VinciTM Surgical Robot System

  • Kim, Ji Eon;Jung, Sung-Ho;Kim, Gwan Sic;Kim, Joon Bum;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.93-97
    • /
    • 2013
  • Background: Minimally invasive cardiac surgery has emerged as an alternative to conventional open surgery. This report reviews our experience with atrial septal defect using the da VinciTM surgical robot system. Materials and Methods: This retrospective study included 50 consecutive patients who underwent atrial septal defect repair using the da VinciTM surgical robot system between October 2007 and May 2011. Among these, 13 patients (26%) were approached through a totally endoscopic approach and the others by mini-thoracotomy. Nineteen patients had concomitant procedures including tricuspid annuloplasty (n=10), mitral valvuloplasty (n=9), and maze procedure (n=4). The mean follow-up duration was $16.9{\pm}10.4$ months. Results: No remnant interatrial shunt was detected by intraoperative or postoperative echocardiography. The atrial septal defects were mainly repaired by Gore-Tex patch closure (80%). There was no operative mortality or serious surgical complications. The aortic cross clamping time and cardiopulmonary bypass time were $74.1{\pm}32.2$ and $157.6{\pm}49.7$ minutes, respectively. The postoperative hospital stay was $5.5{\pm}3.3$ days. Conclusion: The atrial septal defect repair with concomitant procedures like mitral valve repair or tricuspid valve repair using the da VinciTM system is a feasible method. In addition, in selected patients, complete port access can be helpful for better cosmetic results and less musculoskeletal injury.

Gluteus Maximus Muscle Flap in Tongue in Groove and Wrap Around Pattern for Refractory CSF Leakage in Extradural Cyst Patient

  • Park, Kyong Chan;Lee, Jun Ho;Shim, Jae Jun;Lee, Hyun Ju;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.365-368
    • /
    • 2022
  • Spinal extradural arachnoid cyst (SEAC) is a rare disease and has surgical challenges because of the critical surrounding anatomy. We describe the rare case of a 58-year-old woman who underwent extradural cyst total excision with dural repair and presented with refractory cerebrospinal fluid (CSF) leakage even though two consecutive surgeries including dural defect re-repair and lumbar-peritoneal shunt were performed. The authors covered the sacral defect using bilateral gluteus maximus muscle flap in tongue in groove and wrap around pattern for protection of visible sacral nerve roots and blockage of CSF leakage point. With the flap coverage, the disappearance of cyst and fluid collection was confirmed in the postoperative radiological finding, and the clinical symptoms were significantly improved. By protecting the sacral nerve roots and covering the base of sacral defect, we can minimize the risk of complication and resolve the refractory fluid collection. Our results suggest that the gluteus muscle flap can be a safe and effective option for sacral defect and CSF leakage in extradural cyst or other conditions.

Basic Research on Evaluation of Defect Repair Period of Finishing Works in Apartment Houses according to Performance Data (실적자료에 의한 공동주택 마감공사의 하자보수기간의 적절성 평가 기초연구)

  • Kim, Dae-gil;Lee, Ung-Kyun;Seo, Deok-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.245-246
    • /
    • 2015
  • Cases of lawsuit and conflict are increasing because of defects in apartments in use after the completion of construction. Further, with changes in the consciousness of residents and in the social environment, many residents are showing interest in defect-related lawsuits. However, the term of warranty liability defined in the current law is not practically appropriate, and the verification of the determination of the term of warranty liability is insufficient. Against this background, this research aims to evaluate the appropriateness of defect repair periods by examining the actual defect condition of the finishing work among the various defects related to apartments. Collected performance data are analyzed by statistical techniques by considering the defect occurrence rate per construction type and the construction year of the finishing work in apartment construction. The analysis results will be used as basic data for evaluating the appropriateness of the standards for the term finishing works warranty liability.

  • PDF

Simplified Approach to Repair of Complete Atrioventricular Septal Defect (완전방실중격결손수술의 단순화)

  • 김웅한;김수철;오삼세;정도현;정홍주;김욱성;이창하;정철현;나찬영
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.899-902
    • /
    • 1998
  • Recent advances in understanding the anatomy of complete atrioventricular septal defect have led to alternative methods of repairing these defects. Here we report two cases of complete atrioventricular septal defect repair by direct closure of the ventricular element of the defect. Follow-up for average of 3 months suggests that, when direct closure can be performed, the results can be comparable with those of the standard technique. Our initial success with this approach is encouraging; however, longer follow-up and more experiences are required to establish whether it will be broadly applicable.

  • PDF

Staged Repair of Truncus Arteriosus Associated with Complete Atrioventricular Septal Defect

  • Lim, Mi Hee;Sung, Si Chan;Kim, Hyung Tae;Choi, Kwang Ho;Lee, Hyoung Doo;Kim, Geena
    • Journal of Chest Surgery
    • /
    • v.51 no.5
    • /
    • pp.356-359
    • /
    • 2018
  • We report a case of successful repair of truncus arteriosus (TA) associated with complete atrioventricular septal defect (c-AVSD) using a staged approach. TA associated with c-AVSD is a very rare congenital cardiac anomaly. No report of successful staged repair in South Korea has yet been published. We performed bilateral pulmonary artery banding when the patient was 33 days old, and total correction using an extracardiac conduit was performed at the age of 18 months. The patient recovered uneventfully and is doing well.

Analysis of Problems and Improvement of Inter-layer Joints in Apartment Houses (공동주택 층간이음부의 문제점 분석 및 개선안)

  • Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.200-201
    • /
    • 2021
  • According to the dispute cases filed for claiming the collective defect repair fees, inter-layer concrete joints turned out to be the most frequently disputed item. For this reason, this study selects the inter-layer concrete joints to further analyze the primary causes and details of each dispute case. From the results of this study, three primary causes of the disputes are found, which are 1) the absence of standard specifications for construction quality control and management after construction; 2) the absence of established standards for repair when construction defects are found. In order to prevent construction defects in inter-layer concrete joints, this study provides three suggestions including 1) the current standard specifications for inter-layer concrete joints should be further specified by the Ministry of Land, Infrastructure and Transport; 2) a construction defect should be judged according to the compliance to the standard specifications; and 3) a clear and institutional protocol needs to be established for defect repair in cases that new public apartment houses have been judged to have defects.

  • PDF

The Clamshell Incision for the Complete Repair in Pulmonary Atresia with Ventricular Septal Defect, and Major Aortopulmonary Collaterals (주대동맥폐동맥간 부행혈관이 동반된 폐동맥 형성부전 환아에서의 Clamshell 절개를 통한 완전교정술 -1례 보고-)

  • 차대원;박표원;전태국;강이석;이흥재
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.823-826
    • /
    • 1999
  • A 6-month old girl who had pulmonary atresia with ventricular septal defect and major aortopulmonary collaterals underwent one-stage complete repair with unifocalization through a bilateral thoracosternotomy(clamshell incision). There were no serious postoperative compli cations, and the postoperative echocardio-graphy showed no residual ventricular septal defect or significant pulmonary artery stenosis. In this condition, great surgical variability exists regarding the sources of pulmonary blood flow. Recent clinical work has focused on a one-stage complete repair. The potential advantages of the clamshell incision are apparent in terms of mediastinal approach, postoperative results, and safety.

  • PDF

Nuss Operation with Simultaneous Intracardiac Repair -A case report- (선천성 심기형에 동반된 누두흉에서 동시에 시행안 심기형 교정 및 Nuss 수술 -1예 보고-)

  • 허재학;장지민;김욱성;장우익;정철현
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.536-538
    • /
    • 2004
  • There are still some controversies regarding one stage repair of pectus deformity with congenital heart disease due to probable complications after extensive resection of deformed cartilages. We performed Nuss operation with simul-taneous intracardiac repair in 8 year old patient with pectus excavatum and partial atrioventricular septal defect. The result of operation was satisfactory without prolongation of operation time, bleeding or instability of chest wall.

Treatment of Massive Defect in Achilles Tendon with Tendon Allograft: A Case Report (동종 건을 이용한 아킬레스건의 광범위 결손의 치료: 증례 보고)

  • Lee, Jung-Woo;Kim, Myung-Jin;Ahn, Jae Hoon;Byun, Chu-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.3
    • /
    • pp.114-117
    • /
    • 2015
  • Deep infection of Achilles tendon is one of the serious complications that occur after open repair of the tendon. It sometimes leads to a very large tendon defect during the course of treatment. We report on a case of massive defect in Achilles tendon, which was successfully treated with Achilles tendon allograft and flexor hallucis longus tendon transfer.