• 제목/요약/키워드: Repair material and method

검색결과 350건 처리시간 0.024초

콘크리트 균열보수부의 내피로성능에 관한 연구 (A study on the fatigue performance of repaired concrete structure.)

  • 권용주;강동수;김규용;박성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.535-538
    • /
    • 2005
  • The problem of the crack which occures from the reinforced concrete structure. could be caused by the complexed factors. When the crack happen, it caused fatal blemish to manage and maintain the structure such as structural problem, licking, spalling, viewing Even though they study and work hard to solve this kind of problem in the world, there are no countermeasure for perfect prevention of crack. After the crack checked out, a method of repair-reinforcement has been sutdied and operated actively. In this experiment, studied durability of repair material. Experiment wave and durability of epoxy and urethane's were shown good result, and micro cement's durability displayed result that is not good. Result of a repeat tired experiment displayed result that micro cement is bad.

  • PDF

1세이하의 총폐정맥 환류이상증의 완전교정 (Repair of Total Anomalous Pulmonary Venous Return in Infant)

  • 홍유선;박영환;임상현;조범구;노환규
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1004-1008
    • /
    • 1999
  • Background: Total anomalous pulmonary venous return is a relatively rare disease which has a very high mortality(80% within a year) if not properly corrected surgically. Material and Method: Twenty-six infants with total anomalous pulmonary venous return underwent repair between May, 1991 and February, 1996. Result: There were 19 boys and 7 girls. The mean age at operation was 2.6 months(range: 5 day to 11 month) and the mean body weight was 4.3kg(range:2.8 to 6.7 kg). Preoperative stabilization included ventilator for 5 patients and inotropic support for 6 patients. There were 6 hospital mortalities. Significant risk factors of operative mortality were preoperative ventilator care(p<0.03) and preoperative inotropic support(p<0.05). Age, body weight at operation, pulmonary venous obstruction, high pulmonary arterial pressure, spurasystemic right ventricular pressure or emergency operation did not affected the operative outcome. Postperative pulmonary venous obstruction occurred in three patients 2 or 3 months later, among them one patient was reoperated. The actuarial survival was 76% at 40 months. Conclusion: Although early mortality was high, repair of total anomalous pulmonary venous return should be attempted in early life, but the patients receiving ventilator care or inotropic support need special attention.

  • PDF

Rapid Repair of Severely Damaged RC Columns with Different Damage Conditions: An Experimental Study

  • He, Ruili;Sneed, Lesley H.;Belarbi, Abdeldjelil
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권1호
    • /
    • pp.35-50
    • /
    • 2013
  • Rapid and effective repair methods are desired to enable quick reopening of damaged bridges after an earthquake occurs, especially for those bridges that are critical for emergency response and other essential functions. This paper presents results of tests conducted as a proof-of-concept in the effectiveness of a proposed method using externally bonded carbon fiber reinforced polymer (CFRP) composites to rapidly repair severely damaged RC columns with different damage conditions. The experimental work included five large-scale severely damaged square RC columns with the same geometry and material properties but with different damage conditions due to different loading combinations of bending, shear, and torsion in the previous tests. Over a three-day period, each column was repaired and retested under the same loading combination as the corresponding original column. Quickset repair mortar was used to replace the removed loose concrete. Without any treatment to damaged reinforcing bars, longitudinal and transverse CFRP sheets were externally bonded to the prepared surface to restore the column strength. Measured data were analyzed to investigate the performance of the repaired columns compared to the corresponding original column responses. It was concluded that the technique can be successful for severely damaged columns with damage to the concrete and transverse reinforcement. For severely damaged columns with damaged longitudinal reinforcement, the technique was found to be successful if the damaged longitudinal reinforcement is able to provide tensile resistance, or if the damage is located at a section where longitudinal CFRP strength can be developed.

티타늄 금속을 활용한 수열온도 예측용 간이측정장치 개발에 관한 기초적 연구 (A Fundamental Study on Development Hydrothermal Temperature Measuring Tools Using Titanium)

  • 심상락;류동우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.199-200
    • /
    • 2016
  • Accurate fire diagnoses are needed to properly repair and strengthen buildings affected by fire. The current diagnosis method of fire takes time and is ineffective. In previous research, Melting point temperature of each sequence to grasp easily the temperature of the concrete up to 200 ~ 600 ℃ was to estimate the temperature by utilizing a different sequence representing material.But In the form of conventional hydrothermal temperature prediction simple measuring device, it is difficult in the future buried in application to the construction site, there is a problem of damage when concrete pouring, and only the extension of life measured by the zinc has a problem does not distinguish between 400 ℃ and 500 ℃. Therefore this study is conducted by utilizing a titanium metal changes the color depending on the temperature to check for the applicability of the simple apparatus for measuring the temperature prediction sequence.

  • PDF

탄소섬유시트를 활용한 터널의 보수.보강 (The Repair and Reinforcement of Tummel using The Carbon Fiber Sheet)

  • 권영진;전형기;이병훈;최롱;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.526-531
    • /
    • 1996
  • Most of existing tunnels in Korea have structural and material defects, such as lack of the thickness in the crown and presence of an opening behind thie lining as a result of its construction. In Japan, it is said that carbon fiver sheet is very attractive for the upgrading damaged tunnel due to its good tensile strength, handability and resistance to corrosion. This report is the summary of the applicability of continous carbon fiber sheet for a repair and reiforcement of existing tummel located in Masan. It is the aim of this study to analyze the site data related to consturcion method used carbon fiber sheet.

  • PDF

FRP 이음방식에 따른 구조강도 특성에 관한 연구 (A Study on the Strength Characteristics of the FRP Bonding Method)

  • 김경우;강대곤;백명기;박재학
    • 해양환경안전학회지
    • /
    • 제21권6호
    • /
    • pp.778-783
    • /
    • 2015
  • 본 연구는 해상에서의 안전사고의 경감과 국민의 생명을 보호하기 위한 목적으로 자체 연구를 수행하여 FRP의 수리공법인 Butt Joint, Lap Joint, V-Scarf Joint(12t, 16t, 20t), X-Scarf Joint(12t 16t, 20t)의 인장강도와 굽힘강도를 통해 이음방식에 따른 구조강도 특성을 실험하였다. 이음 방법에 따른 인장강도와 굽힘강도의 시험편을 종합 분석한 결과, 인장강도의 강도와 굽힘강도의 그래프 패턴은 비슷한 양상으로 증가와 감소를 하였으며, 인장강도와 굽힘강도 모두 X-Scarf-Butt Joint-V-Scarf-Lap Joint 순으로 강도가 우수하였다. 인장강도는 강도특성이 가장 우수한 X-Scarf라 하더라도 Basic Material의 57% 수준의 강도를 나타내었고 굽힘강도는 X-Scarf가 Basic Material의 77% 수준의 강도를 나타내었다. 종합적으로 Over-Lay 구분을 포함하여 X-Scarf 12t 이음이 인장강도, 굽힘강도 특성이 우수하였으며 Lap Joint가 가장 좋지 않았다. Scarf 이음시 Taper 길이에 따른 강도의 차이는 V-Scarf 이음은 Taper의 길이가 가장 큰 20t가 인장강도, 굽힘강도 특성이 우수한 반면 X-Scarf 이음은 Taper의 길이가 가장 짧은 12t가 인장강도, 굽힘강도 특성이 우수하여 상반되는 결과를 나타내었다. 선박에는 많은 Stress가 작용하여 시험편만을 가지고 실험한 본 연구와 직접적인 비교는 힘들지만, 재료의 가장 기본 특성을 인장강도와 굽힘강도 시험을 통해 확인할 수 있다. FRP 국부적인 수리 방법인 Butt Joint, Lap Joint, V-Scarf, X-Scarf 4가지의 이음방법에 따른 시험값과 모재 대비 감소되는 비율을 제시하였고 추가적으로 V-Scarf와 X-Scarf의 Taper 길이별 특성을 12t, 16t, 20t로 구분한 결과값을 제시함으로써 수리 현장에서의 위치별 특성에 맞는 수리 방법의 응용이 가능하도록 하였다.

복합재료 보강재로 보수되어진 균열을 가진 두꺼운 평판의 피로균열 성장에 관한 연구 (A Study on Fatigue Crack Growth of Composite Patching Repaired on Cracked Thick Plate)

  • 정기현;양원호;고명훈
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.2070-2077
    • /
    • 2001
  • An experimental investigation of the effect of composite patching repair was conducted to characterize the fatigue crack growth behavior in thick A16061-T6 (6mm) panels with single bonded patch by fiber reinforced composite patch. Four patch lengths and no patch plate were examined. An analytical procedure, involving three-dimensional finite element method having three layers to model cracked aluminum plate, epoxy by adhesive and composite Patch, is calculated the stress intensity factors. From the calculated stress intensity factors, the fatigue crack growth rates are obtained. At the single patching type, different fatigue crack growth ratios through the palate thickness were investigated by using the experimental and analytical results. The results demonstrated that there was a definite variation in fatigue life depending on the size of composite patch. While crack reached the patch end, retardation of crack growth was also revealed in the bonded repair.

보수된 균열을 가진 두꺼운 평판의 피로균열 성장 거동에 관한 실험적 연구 (A Experimental Study on the Fatigue Crack Growth Behavior of Thick Plate with Repaired Crack)

  • 정기현;양원호;김철;성기득
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.292-298
    • /
    • 2001
  • An experimental investigation of the effect of composite patching repair was conducted to characterize the fatigue crack growth behavior in thick A16061-T6 (6mm) panels with single bonded patch by fiber reinforced composite patch. Four patch lengths and no patch plate were examined. An analytical procedure, involving three-dimensional finite element method having three layers to model cracked aluminum plate, epoxy by adhesive and composite patch, is calculated the stress intensity factors. From the calculated stress intensity factors, the fatigue crack growth rates are obtained. At the single patching type, different fatigue crack growth ratios through the plate thickness were investigated by using the experimental and analytical results. The results demonstrated that there was a definite variation in fatigue life depending on the size of composite patch. While crack reached the patch end, retardation of crack growth was also revealed in the bonded repair.

  • PDF

지하 콘크리트 구조물 누수부위에 시공되는 5계열 보수재료의 유실 저항 성능 평가 연구 (A Study on the Performance Evaluation of Water(wash out) Resistance of 5-Type Repair Materials in Water Leakage of Underground Concrete Structures)

  • 김수연;유재용;오상근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.61-68
    • /
    • 2020
  • 본 연구에서는 지하 콘크리트 구조물의 누수 균열에 사용되는 주입형 누수보수재료의 품질관리 방안으로 규격화된 국제표준 ISO TS 16774 「Part 3 Test method for water(wash out) resistance」와 KS F 4935 「점착유연형 고무 아스팔트계 누수보수용 주입형 실링재」를 이용하여 현재 우리나라 누수보수현장에서 사용하고 있는 주입형 누수보수재료 5계열(합성고무계, 시멘트계, 아크릴계, 에폭시계, 우레탄계) 3종류씩, 총 15종류의 보수재료에 대한 지하 콘크리트 구조물이 처한 지하수의 유동성에 관한 유실 대응력의 안정성을 연구·검토하였다. 그 결과, KS F 4935 규격에서 규정하고 있는 "질량 변화율이 -0.1% 이내"의 성능 기준으로 고찰하면 합성고무계 RG-2, 우레탄계의 UG-1을 제외하고 나머지 13Type 보수재료는 다소 지하수의 유동성에 따른 유실 저항력의 안정화 방안 검토가 필요 할 것으로 판단된다. 본 연구 결과는 콘크리트 구조물의 균열 부위에 사용되는 보수재료의 선정에 있어 기본 지표로 사용가능 할 것으로 판단된다. 또한, 추후에 연구 개발 되는 보수재료의 품질 향상에 반영할 수 있는 기준 자료의 활용을 기대할 수 있다.

국내 업무시설 건축 마감재의 수선율 산정 방안에 관한 연구 (A Study on the Estimation Method of the Repair Rates in Finishing Materials of Domestic Office Buildings)

  • 김선남;유현석;김영석
    • 한국건설관리학회논문집
    • /
    • 제16권1호
    • /
    • pp.52-63
    • /
    • 2015
  • 국내 건축물 중 업무시설은 국가 경제발전 및 산업구도의 변화와 더불어 급속도로 보급되기 시작하여 2012년 수도권 기준 소방대상물 현황 31개종 중 공동주택 다음으로 많은 비중을 차지하고 있는 주요 시설물이다. 그러나 2014년 현재 수도권지역 업무시설 중 70% 이상이 사용기간 15년 이상으로 주요 건축 마감재의 노후화와 기능저하가 시작되는 등 수선이 시급한 업무시설이 지속적으로 증가하고 있는 실정이다. 특히, 업무시설은 사옥 또는 임대사무실의 목적으로 활용되고 있어 시설물의 노후화와 기능 저하가 초래될 경우 건축주와 유지관리 주체에게 임대 경쟁력 저하 및 부동산 가치 하락 등의 문제점을 가져올 수 있다. 이와 같은 시설물의 노후화와 기능 저하를 예방하기 위해서는 준공 후 경과연수에 따라 수선율을 기준으로 한 예방적 차원의 계획 수선을 필요로 한다(La et al. 2001). 이러한 수선율을 기준으로 하는 국내의 수선기준들은 그 대상의 범위가 주로 공동주택과 공공기관 시설물에 국한되어 있어 업무시설에 해당 기준을 적용하기에는 한계성이 있으며, 현업에서의 수선계획 수립을 위한 수선율 기준의 적용성 제고를 위해서는 필수적으로 연간단위의 마감재별 수선율 데이터가 요구되고 있는 것으로 조사 분석되었다. 따라서 본 연구의 목적은 6개소 업무시설의 실제 수선이력데이터를 수집 및 분석하여 업무시설을 대상으로 한 건축 마감재의 수선율 산정 모형을 개발하고 사례적용을 통해 도출된 마감재별 연간단위 수선율의 적정성을 검증하는 것이다. 본 연구의 결과물은 업무시설의 건축주 및 유지관리 주체들로 하여금 발생 가능한 돌발적 보수비용과 기회비용의 낭비를 예방케 함으로써 보다 효율적인 유지보수 예산의 계획과 집행을 가능하게 할 수 있을 것으로 기대된다.