• 제목/요약/키워드: Renewable Energy Systems

검색결과 901건 처리시간 0.025초

가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구 (An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System)

  • 공형진;강성재;윤경식;임효재
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

침출수 순환형 음식물류 폐기물 혐기성 소화공법에 대한 초기 특성 파악 (Preliminary Evaluation of Leachate Recirculation Anaerobic Digestion System to treat Source Separated Food Waste)

  • 이병희;이제승
    • 유기물자원화
    • /
    • 제21권4호
    • /
    • pp.50-61
    • /
    • 2013
  • 교내 식당에서 분리 수거된 음식물류 폐기물에서 재생 에너지인 메탄가스를 생산하기 위해 혐기성 소화시스템에 대한 연구가 수행되었다. 1차 실험에서 침출수 인발/반송도 없고 혼합도 없는, 침출수 인발/반송은 없고 혼합이 있는, 침출수 인발/반송은 있고 혼합이 없는, 그리고 침출수 인발/반송은 있고 혼합이 있는 4개의 혐기성 시스템에서 침출수 인발/반송은 있고 혼합이 없는 시스템에서 가스발생이 가장 많은 것으로 나타났다. 반응조 혼합이 없고 침출수 인발/반송이 수행되는 시스템에서는 침출수의 반응조 내 침출수 유출속도가 빠른 경우에 혐기성 반응이 활발히 일어난 것으로 관찰되었다. 가스수집기 무게가 1kg이고 음식물류 폐기물 C/N비가 10이상이 되는 경우 혐기성 반응조의 가스가 소모되어 가스수집기에 부압이 걸리는 것이 관찰되었는데, 이에 대한 원인을 밝히는 것이 음식물류 폐기물에서 재생에너지를 회수하는데 필수적이다.

우드칩 반탄화와 부생가스의 특성 분석 (The Characterization of Woodchip Torrefaction and Byproduct Gas)

  • 강구;왕용;홍성구
    • 한국농공학회논문집
    • /
    • 제56권6호
    • /
    • pp.55-62
    • /
    • 2014
  • Torrefaction is considered as a promising pre-treatment for thermochemical utilization of biomass. Torrefaction temperature and time are the critical operation parameters. In this study, investigated were the effects of reaction temperature and time on product composition of torrefaction. scanning electron microscope (SEM) images and thermo gravimetric analyzer (TGA) results were also compared for the effects of the operating parameters. SEM images showed that the pores were observed at the temperature of $250^{\circ}C$ for 30 minutes. Rapid decreases in weight were observed the temperature between 200 and$400^{\circ}C$. Higher heating value of the torrefied biomass was over 5,000 kcal/kg at the temperature of $250^{\circ}C$ for 45 minutes. Energy density, which is defined as the ratio of the energy yield over the mass yield was 1.36 at the temperature of $250^{\circ}C$ for 45 minutes. The energy density was higher up to 1.6 at the temperature of $280^{\circ}C$, which indicates greater loss in mass. The major components of the gas produced in the torrefaction were $CO_2$ and CO, with traces of methane. The total amount of gas was 31.54 l/kg and the calorific value of the gas was $1,164.4Kcal/Nm^3$ at the temperature of $250^{\circ}C$ for 30 minute reaction time. Based on the results of this study, the temperature of effective torrefaction is about $250^{\circ}C$ for 30 to 45 minutes of reaction time. Considering the heating value, it is desirable to utilize the gas for efficient process of torrefaction.

리튬이차전지의 과충전에 의한 열폭주 현상의 이해 (Understanding Thermal Runaway Phenomena in Overcharged Lithium-Ion Batteries)

  • 이민서;유지선;강경신;이재승;봉성율
    • 전기화학회지
    • /
    • 제27권2호
    • /
    • pp.55-72
    • /
    • 2024
  • 이차전지는 우리 생활에 있어 지구온난화에 따른 화석연료의 대체원으로서 전기차 및 에너지저장장치(Energy storage system, ESS) 등 필수불가결한 신재생에너지원으로 활용하고 있다. 그러나, 과방전, 고속충방전, 단락 등 여러 원인에 따른 이차전지 내 열폭주 현상으로 인해 배터리 화재 및 폭발에 대한 사건사례들이 보고되고 있으며, 각각의 원인에 적합한 해결책을 찾기 위해 많은 노력을 기울이고 있다. 특히, 과충전 과정에서 원인으로 추정되는 사례들이 지속적으로 보고되고 있으므로, 본 총설에서는 과충전 과정에서 발생할 수 있는 이차전지의 화학적 반응들을 살펴보고, 이를 점검 및 예방하기 위한 위험조사방법에 대해서 이야기하고자 한다.

저탄소 에너지 전환을 위한 2030년 최적전력구성비: 노후 원전 단계적 폐쇄와 INDC를 고려한 시나리오 (The Optimal Energy Mix in South Korea's Electricity Sector for Low Carbon Energy Transition in 2030: In Consideration of INDC and Sequential Shutdown of Decrepit Nuclear Power Plants)

  • 김동윤;황민섭
    • 환경영향평가
    • /
    • 제26권6호
    • /
    • pp.479-494
    • /
    • 2017
  • 후쿠시마 사태 이후 형성된 원전에 대한 부정적인 여론은 몇몇 국가에서 '탈원전'이라는 정책으로 표출됐다. 한국도 문재인 정부가 들어서면서 원전의 비중을 단계적으로 낮추는 에너지 정책 전환 계획을 발표했다. 이로써 기후변화와 에너지 안보라는 두 가지 문제를 동시에 해결할 주요 에너지원으로 꼽혔던 원전 사용에 제한이 발생했다. 이 연구는 원전의 단계적 폐쇄를 주요 내용으로 하는 에너지 정책 전환 이행과 기후변화체제라는 상황 속에서 2016년부터 2030년까지 한국의 최적전력구성비를 찾는 것이 목적이다. 최적전력구성비는 시간당 전력수요와 INDC를 최소비용으로 만족하는 구성비를 의미한다. 이 연구에서는 선형계획법을 통해 에너지 정책 전환을 이행하는 시나리오와 원전을 2017년 수준으로 유지하는 시나리오로 나누어 비용을 비교분석했다. 그 결과 두 시나리오 모두 풍력은 2018년부터 꾸준히 증가하는 반면 태양광은 2021년부터 경제성을 갖춰 발전량이 대폭 늘어났다. 한편 총 비용은 에너지 전환 시나리오가 약 56조원으로 원전 유지 시나리오에 비해 약 5.5조원 더 비싼 것으로 나타났다.

건물 에너지 시뮬레이션을 이용한 반밀폐형 온실의 동적 에너지 부하 예측 및 수소연료전지 3중 열병합 시스템 적정 용량 산정 (Optimal Capacity Determination of Hydrogen Fuel Cell Technology Based Trigeneration System And Prediction of Semi-closed Greenhouse Dynamic Energy Loads Using Building Energy Simulation)

  • 이승헌;김락우;김찬민;석희웅;윤성욱
    • 생물환경조절학회지
    • /
    • 제32권3호
    • /
    • pp.181-189
    • /
    • 2023
  • 수소는 다양한 신재생에너지 중 환경친화적인 에너지로 각광받고 있지만 농업에 적용된 사례는 드물다. 본 연구는 수소연료전지 삼중 열병합 시스템을 온실에 적용하여 에너지를 절약하고 온실가스를 줄이고자 한다. 이 시스템은 배출된 열을 회수하면서 수소로부터 난방, 냉각 및 전기를 생산할 수 있다. 수소 연료 전지 삼중 열 병합 시스템을 온실에 적용하기 위해서는 온실의 냉난방 부하 분석이 필요하다. 이를 위해서는 온실의 형태, 냉난방 시스템, 작물 등을 고려해야 한다. 따라서 본 연구에서는 건물 에너지 시뮬레이션(BES)을 활용하여 냉난방 부하를 추정하고자 한다. 전주지역의 토마토를 재배하는 반밀폐형 온실을 대상으로 2012년부터 2021년까지의 기상데이터를 수집하여 분석했다. 온실 설계도를 참고하여 피복재와 골조를 모델화하여 작물 에너지와 토양 에너지 교환을 실시했다. 건물 에너지 시뮬레이션의 유효성을 검증하기 위해 작물의 유무에 의한 분석, 정적 에너지 및 동적 에너지 분석을 실시했다. 또한 월별 최대 냉난방 부하 분석에 의해 평균 최대 난방 용량 449,578kJ·h-1, 냉방 용량 431,187kJ·h-1이 산정되었다.

폐스팀을 이용한 가역 고체산화물 연료전지의 기술적 경제적 해석 (Techno-Economic Analysis of Reversible Solid Oxide Fuel Cell System Couple with Waste Steam)

  • 잡반티엔;이영덕;김영상;안국영
    • 한국수소및신에너지학회논문집
    • /
    • 제30권1호
    • /
    • pp.21-28
    • /
    • 2019
  • Reversible solid oxide fuel cell (ReSOC) system was integrated with waste steam for electrical energy storage in distributed energy storage application. Waste steam was utilized as external heat in SOEC mode for higher hydrogen production efficiency. Three system configurations were analyzed to evaluate techno-economic performance. The first system is a simple configuration to minimize the cost of balance of plant. The second system is the more complicated configuration with heat recovery steam generator (HRSG). The third system is featured with HRSG and fuel recirculation by blower. Lumped models were used for system performance analyses. The ReSOC stack was characterized by applying area specific resistance value at fixed operating pressure and temperature. In economical assessment, the levelized costs of energy storage (LCOS) were calculated for three system configurations based on capital investment. The system lifetime was assumed 20 years with ReSOC stack replaced every 5 years, inflation rate of 2%, and capacity factor of 80%. The results showed that the exergy round-trip efficiency of system 1, 2, 3 were 47.9%, 48.8%, and 52.8% respectively. The high round-trip efficiency of third system compared to others is attributed to the remarkable reduction in steam requirement and hydrogen compression power owning to fuel recirculation. The result from economic calculation showed that the LCOS values of system 1, 2, 3 were 3.46 ¢/kWh, 3.43 ¢/kWh, and 3.14 ¢/kWh, respectively. Even though the systems 2 and 3 have expensive HRSG, they showed higher round-trip efficiencies and significant reduction in boiler and hydrogen compressor cost.

복합제품시스템 추격을 위한 특허 기반 부상기술 탐색: 가스터빈 사례를 중심으로 (Exploration of emerging technologies based on patent analysis in complex product systems for catch-up: the case of gas turbine)

  • 곽기호;박주형
    • 지식경영연구
    • /
    • 제17권2호
    • /
    • pp.27-50
    • /
    • 2016
  • Korean manufacturing industry have recently faced the catch-up of China in the mass commodity product, such as automotive, display, and smart phone in terms of market as well as technology. Accordingly, discussion on the importance of achieving catch-up in complex product systems (CoPS) has been increasing as a new innovation engine for the industry. In order to achieve successful catch-up of CoPS, we explored emerging technologies of CoPS, which are featured by the characteristics of radical novelty, relatively fast growth and self-sustaining, through the study of emerging technologies of gas turbine for power generation. We found that emerging technologies of the gas turbine are technologies for combustion nozzle and composition of electrical machine for increasing power efficiency, washing technology for particulate matter, cast and material processing technology for enhancing durability from fatigue, cooling technologies from extremely high temperature, interconnection operation technology between renewable energy and the gas turbine for flexibility in power generation, and big data technology for remote monitoring and diagnosis of the gas turbine. We also found that those emerging technologies resulted in technological progress of the gas turbine by converging with other conventional technologies in the gas turbine. It indicates that emerging technologies in CoPS can be appeared on various technological knowledge fields and have complementary relationship with conventional technologies for technology progress of CoPS. It also implies that latecomers need to pursue integrated learning that includes emerging technologies as well as conventional technologies rather than independent learning related to emerging technologies for successful catch-up of CoPS. Our findings provide an important initial theoretical ground for investigating the emerging technologies and their characteristics in CoPS as well as recognizing knowledge management strategy for successful catch-up of latecomers. Our findings also contribute to the policy development of the CoPS from the perspective of innovation strategy and knowledge management.

지능형 풍력발전 기계적 요소 고장진단 시스템 개발 (Development of intelligent fault diagnostic system for mechanical element of wind power generator)

  • 문대선;김성호
    • 한국지능시스템학회논문지
    • /
    • 제24권1호
    • /
    • pp.78-83
    • /
    • 2014
  • 최근 신재생 에너지원으로서의 선두주자인 풍력발전은 다수의 풍력발전 회사들로 하여금 모니터링 및 고장진단 시스템의 개발을 가속화시키고 있다. 이러한 모니터링 및 진단시스템은 조기의 고장검출을 통해 고장이 발생되었을 경우 발생되는 고가의 수리비용을 미연에 방지할 수 있게 한다. 일반적으로 풍력발전과 관련된 고장진단 시스템은 진동신호 및 신호분석기법에 기반하고 있다. 이에 본 연구에서는 풍력발전 시스템에서 자주 발생되고 있는 질량 불평형 및 축 정렬 불량 등과 같은 기계적인 고장을 효율적으로 진단할 수 있는 시스템을 제안하고자 한다. 본 연구에서 제안된 지능화된 고장진단 알고리즘은 인공신경망기법과 웨이블렛 변환을 이용한 것으로 (주)가온솔루션에서 개발한 풍력발전용 기계적 고장발생 장치에 적용 실험을 통해 제안된 진단기법의 유용성을 확인하고자 하였다.

Optimal Harmonic Stepped Waveform Technique for Solar Fed Cascaded Multilevel Inverter

  • Alexander, S.Albert;Thathan, Manigandan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.261-270
    • /
    • 2015
  • In this paper, the Optimal Harmonic Stepped Waveform (OHSW) method is proposed in order to eliminate the selective harmonic orders available at the output of cascaded multilevel inverter (CMLI) fed by solar photovoltaic (SPV). This technique is used to solve the harmonic elimination equations based on stepped waveform analysis in order to obtain the optimal switching angles which in turn reduce the Total Harmonic Distortion (THD). The OHSW method considers the output voltage waveform as four equal symmetries in each half cycle. In the proposed method, a solar fed fifteen level cascaded multilevel is considered where the magnitude of six numbers of harmonic orders is reduced. A programmable pulse generator is developed to carry the switching angles directly to the semiconductor switches obtained as a result of OHSW analysis. Simulations are carried out in MATLAB/Simulink in which a separate model is developed for solar photovoltaic which serves as the input for cascaded multilevel inverter. A 3kWp solar plant with multilevel inverter system is implemented in hardware to show the effectiveness of the proposed system. Based on the observation the OHSW method provides the reduced THD thereby improving power quality in renewable energy applications.