• 제목/요약/키워드: Renewable Energy Systems

검색결과 904건 처리시간 0.113초

암반 대수층에서 개방형 지열 시스템의 개발 및 적용 (Development of a Groundwater Source Heat Pump in a Fractured Rock Aquifer)

  • 심병완;김성균;최한나;이수형;하규철;김용철
    • 신재생에너지
    • /
    • 제17권3호
    • /
    • pp.32-41
    • /
    • 2021
  • A groundwater source heat pump (GWHP) was developed in this study by adapting a borehole heat exchanger with closed-loop and open-loop systems in a new building. In the pilot test building, the air-conditioning on the second floor was designed to employ a closed-loop system and that on the third floor had an open-loop system. The GWHP design is based on the feasibility of groundwater resources at the installation site. For the hydrogeological survey of the study site, pumping and injection tests were conducted, and the feasibility of GWHP installation was evaluated based on the air-conditioning load demand of the building. The site was found to be satisfactory for the design capacity of the thermal load and water quality. In addition, the effect of groundwater movement on the performance of the closed-loop system was tested under three different operational scenarios of groundwater pumping. The performance of the system was sustainable with groundwater flow but declined without appropriate groundwater flow. From long-term observations of the operation, the aquifer temperature change was less than 2℃ at the observation well and 5℃ at the injection well with respect to the initial groundwater temperature. This pilot study is expected to be of guidance for developing GWHPs at fractured rock aquifers.

A new lightweight network based on MobileNetV3

  • Zhao, Liquan;Wang, Leilei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권1호
    • /
    • pp.1-15
    • /
    • 2022
  • The MobileNetV3 is specially designed for mobile devices with limited memory and computing power. To reduce the network parameters and improve the network inference speed, a new lightweight network is proposed based on MobileNetV3. Firstly, to reduce the computation of residual blocks, a partial residual structure is designed by dividing the input feature maps into two parts. The designed partial residual structure is used to replace the residual block in MobileNetV3. Secondly, a dual-path feature extraction structure is designed to further reduce the computation of MobileNetV3. Different convolution kernel sizes are used in the two paths to extract feature maps with different sizes. Besides, a transition layer is also designed for fusing features to reduce the influence of the new structure on accuracy. The CIFAR-100 dataset and Image Net dataset are used to test the performance of the proposed partial residual structure. The ResNet based on the proposed partial residual structure has smaller parameters and FLOPs than the original ResNet. The performance of improved MobileNetV3 is tested on CIFAR-10, CIFAR-100 and ImageNet image classification task dataset. Comparing MobileNetV3, GhostNet and MobileNetV2, the improved MobileNetV3 has smaller parameters and FLOPs. Besides, the improved MobileNetV3 is also tested on CPU and Raspberry Pi. It is faster than other networks

하이브리드 발전 시스템을 적용한 이동식 하우스 (Transportable House with Hybrid Power Generation System)

  • 박미정;주종율;김응곤
    • 한국전자통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.205-212
    • /
    • 2023
  • 현대사회는 화석연료 등의 사용으로 기후변화로 인한 기상이변이 전 세계가 이례적인 피해가 속출하고, 코로나와 같은 전염병이 인간에게 더욱 생활의 질이 악화되고 있는 실정이다. 온실가스를 줄이고 신재생에너지 사용이 시급한 현실이다. 화석연료의 사용을 줄이고 신재생에너지 사용으로 지구환경 오염을 줄이고자 한다. 본 논문에서는 태양광을 이용해 지능형 CCTV 및 인터넷 WiFi, 냉난방 시스템을 통한 사계절 환경과 안전 및 통신 기능이 가능하고, 스마트폰 앱을 통한 태양광의 생산량과 소비량을 실시간으로 모니터링하여 최적화된 전력관리를 할 수 있는 시스템을 제안한다. 태양광 발전 시스템을 사용할 수 없는 한파, 태풍, 자연재해 등의 계통 정전과 같은 비상시 끊김 없는 디젤 발전을 지원하는 하이브리드 발전시스템을 제안한다.

운전조건이 PEM 수전해 셀의 성능에 미치는 영향 (Influence of Operation Conditions on the Performance of PEM Water Electrolysis)

  • 장상엽;김재동;박진모;소영석
    • 한국가스학회지
    • /
    • 제28권1호
    • /
    • pp.65-72
    • /
    • 2024
  • 재생에너지 자원이 풍부한 제주도에서 수전해 시스템을 활용하여 그린수소를 생산하는 실증단지를 준비 중이며, 수전해 시스템의 장기 운영시 상황을 검토하기 위하여, PEM 수전해 셀을 가속시험평가 하여 수전해 셀의 내구성을 검토하였고, 제주도 풍력기반의 전력패턴을 적용하였을 때 수전해 셀의 내구성을 검토하였다. 가속시험평가 (저전류-고전류 반복 인가)를 800시간 진행한 후, PEM 수전해 셀의 성능이 최대 10%, 운전조건에서 5.5% 감소되었으며, 임피던스 분석결과 PEM 수전해 셀의 Ohmic 저항보다 전극의 분극저항이 크게 증가한 것을 확인할 수 있다. 그리고 제주도의 풍력패턴을 적용하여 내구성평가를 진행한 경우, PEM 수전해 셀의 성능이 최대 1.6%, 운전 조건에서 1% 미만의 성능감소를 보여주었으며, 임피던스 결과 Ohmic 저항 및 전극의 분극저항의 변화가 작은 것을 알 수 있다.

횡류형 파워터빈의 최적화 설계에 관한 수치해석 연구 (A Numerical Study on an Optimum Design of a Cross-flow Type Power Turbine (CPT))

  • 하진호;김현철;김철호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3050-3055
    • /
    • 2007
  • A wind turbine is one of the most popular energy conversion systems to generate electricity from the natural renewable energy source and an axial-flow type wind turbine is the most popular system for the electricity generation in the wind farm nowadays. In this study, a cross-flow type turbine has been studied for the application of wind turbine for electricity generation. The target capacity of electric power generation of the model wind turbine developing on the project is 12 volts, 130A/H (about 1.56kW). The important design parameters of the model turbine impeller are the inlet and exit angle of the turbine blade, number of blade, hub/tip ratio and the exit flow angle of the casing. In this study, the radial equilibrium theorem was used to decide the inlet and exit angle of the impller blade and CFD technique was used to have the performance analysis of the designed model power turbine to find out the optimum geometry of the CPT impeller and casing. The designed CPT with 24 impeller blades at ${\alpha}=82^{\circ}$, ${\beta}=40^{\circ}$ of turbine blade angle was estimated to generate 284.6 N.m of indicated torque and 2.14kW of indicated power.

  • PDF

주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구 (A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House)

  • 노철우;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.25-28
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system's capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF

초고온가스원자로 열원 SI 공정을 이용한 원자력수소생산시스템 비용 예비 분석 (Preliminary cost estimation for large-scale nuclear hydrogen production based on SI process)

  • 양경진;최재혁;이기영;이태훈;이경우;김만응
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.723-726
    • /
    • 2009
  • As a preliminary study of cost estimates for nuclear hydrogen systems, the hydrogen production costs of the nuclear energy sources benchmarking GT-MHR are estimated in the necessary input data on a Korean specific basis. G4-ECONS developed by EMWG of GIF in 2008 was appropriately modified to calculate the cost for hydrogen production of SI process with VHTR as a thermal energy source rather than the LUEC. The estimated costs presented in this paper show that hydrogen production by the VHTR could be competitive with current techniques of hydrogen production from fossil fuels if $CO_2$ capture and sequestration is required. Nuclear production of hydrogen would allow large-scale production of hydrogen at economic prices while avoiding the release of $CO_2$. Nuclear production of hydrogen could thus become the enabling technology for the hydrogen economy. The major factors that would affect the cost of hydrogen were also discussed.

  • PDF

Battery SOC(State of Charge)측정을 통한 태양광발전 시스템 운영 방안 연구 (A study on the operating method for Photovoltaic system through the SOC measurement of batteies)

  • 송정용;서유진;권오상;정관철;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper, the new improved method for photovoltaic system was studied available for a lighting load by measuring the state of charge of lead-acid batteries. Photovoltaic systems has been evaluated as one of the most new and renewable energy and especially, the Stand-Alone Photovoltaic system has been used to a street light, a road sign light, an air caution light, an emergency call. Many Stand-Alone PV system are installed by a group. Although the pre-installation cost of PV system is high and it has not been operated due to the absence of optimal management standards. In this paper, it is proposed a new operating method by the measurement of lead-acid battery's SOC with a Ah balancing.

독립형 태양광 조명 시스템의 설계 및 성능 평가 연구 (A study on the design and performance of a stand-alone photovoltaic lighting system)

  • 권오상;서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.1-10
    • /
    • 2004
  • In view of global environmental problems and resource exhaustion, we must develop new energy resources that are abundant and provide substitutes for fossil fuels. Renewable energies, such as solar, are ideal because they are clean, inexhaustible, and available everywhere in the world. Photovoltaic(PV) system, in general, are operated as a stand-alone, grid-tied, or hybrid system. Many of the stand-alone PV systems are installed. Although the pre-installation cost of PV system is high, it poorly has been operated due to the absence of optimal management standards. Therefore a study on the performance of PV system is important for the system design and maintenance. In this paper a photovoltaic lighting system was resigned according to load consumption. Then a PV lighting system which used electrodeless lamp as a load was installed. In order to investigate the system operating characteristics we've added a monitoring system to the PV lighting system. The monitoring system using the LabVIEW program regularly checks the operation of the PV lighting system and records the system data. According to the system data, the stability and availability of the PV lighting system were evaluated.

새로운 탄력적인 생활을 위한 플로팅 주택에 대한 연구 (A Study on the Floating House for New Resilient Living)

  • 문창호
    • 한국주거학회논문집
    • /
    • 제26권5호
    • /
    • pp.97-104
    • /
    • 2015
  • This paper aims to discuss the concept of resilience in floating housing, to investigate the resilient features of floating houses & to review the possibility of floating housing as a new form of resilient living, and to suggest some reference ideas for the planning and design of floating housing projects. Resilient features of the floating house can be summarized as the buoyant characteristics for natural disasters, the easy employment & potential use of renewable and nearly self-sufficient energy systems in locations subject to limited energy sources, the movability, mobility, long life, water recycle system, prefabrication and modular construction with the potential for reduced environmental impact. Additional benefits include the potential for a peaceful and comfortable atmosphere due to direct connections with nature, good relationship with neighbors, a solid social spirit of unity, and sense of security. Considering the resilient features of floating house at a time of serious climate change requires a new paradigm, and floating/amphibious/floatable housing has great possibility as a new form of resilient living.