• Title/Summary/Keyword: Removing Stress

Search Result 132, Processing Time 0.027 seconds

Nondestructive Evaluation of Fatigue Damage (피로손상과 비파괴평가)

  • Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • In order to determine the mode I stress intensity factor ($K_I$) by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a paramagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effects of the magnetic flux and the demagnetization on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. The change in potential drop was linearly decreased with increasing the tensile load and was caused by the change in conductivity near the crack tip. The reason of decreasing the change in potential drop with increasing the tensile load was that the increase of the conductivity near the crack tip due to the tensile load caused the decreases of the resistance and internal inductance of the specimen. The relationship between the change in potential drop and the change in $K_I$ was not affected by demagnetization and was independent of the crack length.

  • PDF

A Novel Multi-Level Type Energy Recovery Sustaining Driver for AC Plasma Display Panel (새로운 AC PDP용 멀티레벨 에너지 회수회로)

  • Hong, Soon-Chang;Jung, Woo-Chong;Kang, Kyoung-Woo;Yoo, Jong-Gul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.71-78
    • /
    • 2005
  • This paper proposes a novel multi-level energy recovery sustaining driver for AC PDP(Plasma Display Panel), which solves the problems of the conventional multi-level sustaining driver. While the conventional circuit improves the voltage md current stress of the switching elements in Weber circuit not only there are parasitic resonant currents between resonant inductors and parasitic capacitance and hard switching, but also the changing period between 0 and sustain voltage is too long. Comparing the proposed circuit with the conventional circuit, the number of components are reduced and the parasitic resonant currents in resonant inductors are eliminated Moreover the hard switching problem is solved by using CIM(Current Injection Method) and the operating frequency will be high as much as possible by removing Vs/2 sustain period. And the circuit operations of the proposed circuit are analyzed for each mode and the validity is verified by the simulations using PSpice program.

Scavenging Effects of Hydroxycinnamic acids on Paraquat Induced Hepatotoxicity (II) (Paraquat 유도 간독성에 대한 Hydroxycinnamic acid계 화합물의 독성 경감 효과 (II))

  • 최병기;오은정
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.3
    • /
    • pp.87-93
    • /
    • 1999
  • Antioxidative and scavenging effects were investigated by using two hyaroxycinnamic acids (caffeetannins). such as caffeic acid and chlorogenic acid, on oxidative stress and hepatotoxicity that induced by paraquat. The results are summerized as follows: 1. To assess radical scavenging ability, reduction concentration (IC$\sub$50/) of 1.1 diphenyl-2-dipicrylhydrazine (DPPH) were measured. IC$\sub$50/ values of caffeic acid and chlorogenic acid were 29.7 ${\pm}$0.6 ${\mu}$M and 26.0${\pm}$0.5 ${\mu}$M respectively. Their radical scavenging activities showed concentration-dependent manner. 2. In H$_2$O$_2$-induced hemolysis assay to rat blood, caffeic acid and chlorogenic acid led to different effects, whose hemolysis inhibition ratios at 100 ${\mu}$M were 45.2${\pm}$7.1% and 11.6${\pm}$3.1% respectively 3. In hypoxanthine-xanthine oxidase system producing superoxide anion, caffeic acid and chlorogenic acid showed different inhibitory activities of xanthine oxidase showing 36.8${\pm}$4.3% and 5.4${\pm}$2.3% respectively. 4. To microsomal NADPH dependent cytochrome p-450 reductase in rat liver, paraquat consumed NADPH at a dose-dependent manner from 0 to 1 ${\mu}$M paraquat concentration. Caffeic acid and chlorogenic acid blocked NADPH consumption rates at concentration-dependent manner and inhibition ratios at 100 ${\mu}$M were 67.6% and 59.2% respectively. 5. Administration (30mg/kg, iv) of paraquat to rats caused the marked elevation of glutamic oxaloacetic transaminase (GOT), glutamic pyruvic transaminase (GPT), lactate dehydrogenase (LDH), alkaline phosphatase (ALP) and lipid peroxides (LPO) in the serum and lipid peroxides in the microsome as compared to the control group. Serum GOT, GPT, LDH, ALP and LPO and liver microsomal LPO were reduced significantly by caffeic acid (50mg/kg), chlorogenic acid (25mg/kg) and silymarin (150 mg/kg) as compared to the paraquat group. From these results, caffeic acid and chlorogenic acid exerted their antioxidative agents by removing reactive oxygen substance (ROS) and scavenging effects by inhibiting ROS generating enzyme. As a general, two hydroxyeinnamic acids showed the useful compounds for scavenger and reducer on the paraquat induced hepatotoxicity.

  • PDF

Fabrication of Titanium alloy by Electromagnetic Continuous Casting (EMCC) Method for Medical Applications (전자기 연속 주조법을 이용한 의료용 타이타늄 합금 제작에 관한 연구)

  • Choi, Su-Ji;Lee, Hyun-Jae;Baek, Su-Hyun;Hyun, Soong-Keun;Jung, Hyun-Do;Moon, Byung-Moon
    • Journal of Korea Foundry Society
    • /
    • v.38 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • Electromagnetic continuous casting (EMCC) was used to fabricate Ti-6Al-4V alloys with properties suitable for medical applications. Ti-6Al-4V alloy ingots fabricated by EMCC were subjected to heat treatment, such as residual stress removing (RRS), furnace cooling after solution treatment (ST-FC) and water-cooling after solution treatment (ST-WC), in order to obtain characteristics suitable for the standard. After component analysis, the microstructure and mechanical properties (tensile strength and elongation) were evaluated by ICP, gas analysis, OM, SEM, a Rockwell hardness tester and universal testing machine. The Ti-6Al-4V alloy ingot fabricated by EMCC was fabricated without segregation, and the lamellar structure was observed in the RRS and ST-FC specimens. The ST-WC specimen showed only martensite structure. As a result of evaluating the mechanical properties based on the microstructure results, we found that the water-cooled heat treatment condition after the solution treatment was most suitable for the Ti-6Al-4V ELI standard.

The Fabrication of Four-Terminal Poly-Si TFTs with Buried Channel (Buried Channel 4단자 Poly-Si TFTs 제작)

  • Jeong, Sang-Hun;Park, Cheol-Min;Yu, Jun-Seok;Choe, Hyeong-Bae;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.761-767
    • /
    • 1999
  • Poly-Si TFTs(polycrystalline silicon thin film transistors) fabricated on a low cost glass substrate have attracted a considerable amount of attention for pixel elements and peripheral driving circuits in AMLCS(active matrix liquid crystal display). In order to apply poly-Si TFTs for high resolution AMLCD, a high operating frequency and reliable circuit performances are desired. A new poly-Si TFT with CLBT(counter doped lateral body terminal) is proposed and fabricated to suppress kink effects and to improve the device stability. And this proposed device with BC(buried channel) is fabricated to increase ON-current and operating frequency. Although the troublesome LDD structure is not used in the proposed device, a low OFF-current is successfully obtained by removing the minority carrier through the CLBT. We have measured the dynamic properties of the poly-Si TFT device and its circuit. The reliability of the TFTs and their circuits after AC stress are also discussed in our paper. Our experimental results show that the BC enables the device to have high mobility and switching frequency (33MHz at $V_{DD}$ = 15 V). The minority carrier elimination of the CLBT suppresses kink effects and makes for superb dynamic reliability of the CMOS circuit. We have analyzed the mechanism in order to see why the ring oscillators do not operate by analyzing AC stressed device characteristics.

  • PDF

The Study about the Comparison of Korean-Western Medicine on Hair (모발에 대한 동서의학적 고찰)

  • Jang, In-Wook;Ko, Woo-Shin;Yoon, Hwa-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.4
    • /
    • pp.1-13
    • /
    • 2016
  • Objectives : The purpose of this study is to compare hair and alopecia of Korean Medicine with those of western medicine. Methods : We studied relationships between hair and essense(精), qi(氣), blood(血), five vicera(五臟) and meridians(經絡) through literature review about hair and alopecia. We compared Korean medicine with western medicine on physiology of hair and treatment of alopecia based on the study. Results & Conclusion : 1. Congenital essense(先天之精) is related with genetic factor and acquired essence(後天之精) is connected with nutritional factor. Defending function of Defense qi(衛氣) is related with immune reaction and qi stagnation(氣鬱) is associated with stress reaction. Atrophy of vascular tissues observed in alopecia scalp means deep relationship between blood(血) and alopecia, further deficiency of blood can cause telogen effluvium. 2. Kidney qi(腎氣) is related with inhibiting combination of Androgen receptor and Dihydrotestosterone(DHT) or activating hair growth factior. Pi(脾) is connected with alopecia seborrheica caused by damp-heat(濕熱) and alopecia areata caused by excessive prudence(思慮過度). Heart(心) is associated with atrophy in vascular tissue of scalp and liver(肝) is connected with metabolism. 3. Armpit hair and pubic hair as secondary sex characteristics are realated with Yangming Meridian(陽明經) and beard and hair at crown part where Type II $5{\alpha}$-reductase is activated much are associated with Taiyang Meridian(太陽經). 4. Juglandis Semen pharmacopuncture and Ganoderma lucidum pharmacopucture have better effects on inhibit $5{\alpha}$-reductase than Finasteride. Minoxidil and PRP are similar with promoting blood flow and removing stasis(活血祛瘀). Seven-star needling(七星針) is similar with microneedling. 5. Alopecia can be caused by due to lack of circulation Views we need solution to improve circulation coincide in opinion with Korean Medicine and Western medicine.

Effects of pH and Salinity on the Cultivated Brown Alga Sargassumfulvellum and Associated Animals (갈조류 양식 모자반(Sargassum fulvellum)과 해적생물에 대한 pH와 염분의 효과)

  • Hwang, Eun-Kyeong;Ha, Dong-Soo;Baek, Jae-Min;Wee, Mi-Young;Park, Chan-Sun
    • ALGAE
    • /
    • v.21 no.3
    • /
    • pp.317-321
    • /
    • 2006
  • The effects pH and salinity on the brown alga Sargassum fulvellum were investigated in the context of the removal of two major associated animals, Caprella scaura and Gammaropsis utinomi. Optimum quantum yield (Fv/Fm) of S. fulvellum was also examined in the same experimental conditions as an index of stress. Experiments on pH and salinity tolerances of the two animal species indicated that mortality was more than 80% at extremes of pH (2, 3, 4, 10, 11, 12) and salinity (0, 3.5, 7, 10, 44 psu) after a 5 min treatment. Lethal time (LT50) from pH 2 to pH 4 was less than 90 sec in C. scaura, and less than 70 sec in G. utinomi. From 0 to 10 psu, LT50 was less than 20 sec in C. scaura and less than 60 sec in G. utinomi. The quantum yield of S. fulvellum was not significantly different from controls within the pH range 4~10, and within the salinity range of 7-40 psu. When exposed to pH and salinity conditions outside these ranges, the effect of these factors on the removal of two animal species was higher, but quantum yield was highly reduced. These results indicate that the optimal conditions for removing the animal species without affecting optimum quantum yield were pH 4-10, and salinities 7-10 psu and 44 psu.

A Research on the Epidermic disease of Abdominal Impulse etc. in SangHanMyungRiSokLon (상한명리속론(傷寒明理續論).동기(動氣)외 8증(證)에 대한 연구(硏究))

  • Shin, Je-Sung;Sheen, Yeong-Il
    • Journal of Korean Medical classics
    • /
    • v.19 no.2 s.33
    • /
    • pp.248-265
    • /
    • 2006
  • Impulse of ki refers to palpitation around the navel, it is mostly caused by impairment of yang due to erroneous sweating, deficiency of the spleen yang. Behcet's syndrome caused by prolonged damp-heat and pathogenic germs. Its symptoms are characterized by conjunctival congestion, blue canthus and ulceration of the oral cavity, restlessness all the time, etc. It is advisable to follow the therapeutic principles of clearing away heat and drying damp, detoxicating and sterilizing. Lily disease is one of the emotional disease. It caused by yin deficiency of the heart and lung, found in mental depression or convalescence after a critical disease. Its symptoms are characterized by restlessness, reticence, insomnia, failure to walk, poor appetite, a subjective hot or cold, bitter taste and dark urine. It is advisable to follow the therapeutic principle of nourishing yin to clear away heat. Cholera refers to the disease marked by sudden severe vomiting and diarrhea, and colic of the heart and the abdomen. It is mostly caused by deficiency of the ki in the middle-energizer, emotional stress, etc. It is characterized by such symptoms as sudden severe vomiting and diarrhea, restlessness, etc. It is advisable to follow the therapeutic principles of warming yang and removing toxic substances, and strengthening the spleen and stomach. Heat invasion of blood chamber due to affection of the exterior pathogens, pathogenic heat invading the blood in deficiency and fighting with the blood. Its symptoms are marked by fever, feeling of the fullness, etc. There are deficiency of blood, hot blood and stasis of blood. The different therapeutic treatment should be taken according to different types thereof.

  • PDF

The Integrity Verification of Tube-end Sleeve by ECT (와전류탐상검사에 의한 튜브엔드 슬리브 건전성 검증)

  • Kim, Su Jin;Kwon, Kyung Joo;Suk, Dong Hwa;Park, Ki Tae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.20-24
    • /
    • 2015
  • Steam generator(S/G) tubes in pressurized water reactor (PWR's) are subject to several types of degradation. This degradation includes denting, pitting, intergranular attack(IGA), intergranular stress corrosion cracking(IGSCC), fatigue, fretting and wear. Degradation can be derived from either the primary side(inside) or the secondary side(outside) of the tube. Recent issue for tube degradation in domestic steam generator is the tube end cracking on seal weld region. The seal weld region at the tube end and tube itself is regarded as a pressure boundary between the primary side and the secondary side. One of the Westinghouse Model-F S/G has experienced tube end cracking and its number of plugging approximately becomes to the operating limit up to 5% due to tube end cracking which was reported as SAI/MAI(single/multiple axial indication) or SCI/MCI(Single/multiple circumferential indication) from the results of eddy current testing. Eddy current mock-up test was carried out to determine the origin of cracking whether it is from weld zone area or parent tube. This result was helpful to analyze crack location on ECT data. Correct action on this problem was the installation of tube-end sleeve. Last year, after removing 340 installed plugs from tubes, selected 269 tubes took tube-end sleeve installation. Tube-end sleeve brought pressure boundary from parent tube to installed sleeve tube. Tube-end sleeve has the benefit of reducing outage period and increasing more revenue than replacing S/G. This paper is provided to assist interest parties in effectively understanding this issue.

Loading Effect on ACPD of a Crack in Paramagnetic Material (균열을 가진 상자성체의 교류전위차에 미치는 하중의 영향)

  • Lee, Jeong-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In order to determine the mode I stress intensity factor ($K_I$) by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a paramagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effects of the magnetic flux and the demagnetization on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. The change in potential drop was linearly decreased with increasing the tensile load and was caused by the change in conductivity near the crack tip. The reason of decreasing the change in potential drop with increasing the tensile load was that the increase of the conductivity near the crack tip due to the tensile load caused the decreases of the resistance and internal inductance of the specimen The relationship between the change in potential drop and the change in $K_I$ was not affected by demagnetization and was independent of the crack length.

  • PDF