• Title/Summary/Keyword: Removal device

Search Result 413, Processing Time 0.027 seconds

Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties (여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가)

  • Kim, Tae-Gyun;Cho, Kang-Woo;Song, Kyung-Guen;Yoon, Min-Hyuk;Ahn, Kyu-Hong;Hong, Sung-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.483-490
    • /
    • 2009
  • The aims of this study were to evaluate the removal efficiency for various pollutants in urban storm runoff by a filtration device, and to determine design parameters depending on filter media properties. Appropriate selection of filter media will affect the size and life time of the filtration device. Sets of column tests were performed in order to evaluate the removal efficiency by perlite and a synthetic resin. An investigation of surface properties including CEC (cation exchange capacity) and zeta-potential suggested that the perlite had a superior adsorption capability for cationic pollutants. TCODcr and turbidity were analyzed to investigate the removal characteristic of particulate pollutant. In both columns, the particles in the collected storm runoff was almost completely capture with a small EBCT (empty bed contact time) of 2.5 minutes. Complete clogging at the EBCT of 2.5 minutes occurred after 630 minutes in the perlite column and 810 minutes in the resin column. The removal efficiency of TCODcr and turbidity at the EBCT of 2.5 minutes decreased to below 70% due to an wall effect. The removal efficiency for dissolved pollutant (SCODcr) was negligible due to the insufficient contact time for adsorption. The removal of heavy metals (Cu, Zn, Pb) was mostly ascribed to the filtration of particles containing metals, since the relationship between CEC and the removal efficiency was not apparent. The result of this study would be valuable for the application of filtration device to control of urban storm runoff.

Evaluation of removal performance of a novel two-stage cylinder type cyclone against water and oil droplets (2단 실린더형 싸이클론의 물 및 오일 액적 제거 성능 분석 연구)

  • Kim, Sumin;Kim, Hak-Joon;Kim, Myungjoon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.119-125
    • /
    • 2017
  • A novel two stage cylindrical cyclone was developed for a 3 phase separator in shale oil production industry. The cyclone performance was compared with a cone type cyclone and multi cyclone at the same experimental condition using water and oil mists generated by a humidifier and atomizer at the flow rate 1 to $2m^3/min$. The removal efficiency of total suspended water droplets by the novel cyclone, calculated using inlet and outlet concentrations measured by an optical particle counter, was 99% which is higher than 90% of oil droplet removal efficiency at $2m^3/min$. It might be due to the evaporation of small water droplets during the tests. The water and oil droplet removal performance of the novel cyclone based on the quality factor which is a function of pressure drop and removal efficiency was the highest among three cyclones. The results indicate that the cyclone could be an economical device to remove water and oil mists from shale gas generation processes where a huge three phase separator is commonly used.

Clinical Expenience with Copper T 380A Intrauterine Contraceptive Device (자궁내피임장치 카파티 380A에 관한 임상적 고찰)

  • Bai, Byoung-Choo;Whang, Young-Whan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.2
    • /
    • pp.221-226
    • /
    • 1994
  • Copper T 380A intrauterine devices were inserted to nine thousand and nine hundred twenty women by 51 KAVS-member physicians since January 1, 1993 through December 31, 1993. This study was undertaken for the clinical analysis on a total of 9,920 women wearing Copper T 380A to grasp the effectivness as well as the expulsion rate due to a various side effects. The following features were the results of the study: 1. During the twelve months period, from January 1993 to December 1993, the largest number of IUD insertion per one physician is 740 cases and the smallest number 60 cases, the mean 195 cases. 2. After insertion of Copper T 380A, a total of 117 cases were removed the IUD;81 cases(0.8%) were due to extensive bleeding and 36 cases(O.36%) were due to pain. The pregnancy failure rate represented comparatively lower rate, 0.08% (8 cases) and the expulsion rate was 0.06%(6 cases). 3. The removal rate of Copper T 380A was different by physicians. The highest removal rate for bleeding was 3.13% and 13 physicians(25.5%) did not experience any bleeding cases. 4. For the removal rate for pain, 30 physicians(58.8%) did not experience any removal of IUD due to pain while 21 physicians(41.2%) removed IUD due to pain: 17 physiciansC33.4 %) had 0.1-1.5% of removal rate and 4 physiciansC7.0%) had 1.6-2.1% of removal rate. 5. A total of 43 physicians(84.3 %) did not experience any pregnancy failure case while 8 (15.7%) physicians was experienced pregnancy failure rate. Four physicians(7.8%) had 0.1-0.5% of pregnancy failure rate and 4 physicians had 0.6-1.0% of pregnancy failure rate. 6. Expulsion rate showed comparatively lower, 0.06% in this study. A total of 45 physicians (88.2%) did not experience any expulsion cases while 6 physicians(11.7%) had expulsion rate with the highest expulsion rate of 2.0%.

  • PDF

Reducing the Falling Accident due to the Removal of Safety Fence from Gondola (곤돌라 안전난간 제거 등으로 인한 추락재해 감소방안)

  • Byun, Hyung Shik;Rhim, Jong kuk;Yang, Won Beak
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.2
    • /
    • pp.9-14
    • /
    • 2019
  • Gondola is widely used as a construction facility to perform external finishing work without using scaffolding at a construction site. However, since 2000, there have been 17 deaths from now so these risks associated with work can not be ignored. Therefore, it is expected that it will contribute greatly to prevent related disasters if introducing necessary measures to prevent repeated related disasters and installing additional safety devices. In order to eliminate the risk factor according to the operation of the gondola, it is necessary for the operator to use it to use it while the examination of each product is completed, and to use the over load Dangerous arbitrary measures such as arbitrary operation of the prevention device, removal of the safety fence for convenience of work, installation of the wire rope installed in the air, falling out of the wire rope and falling to the ground Do not perform such sealing measures so that any operation of the overload prevention device can not be done so as not to take such arbitrary measures, or wire the power supply wire to the safety fence so as not to delete the safety fence. Then, when the safety fence is removed, so that it does not become a gondola operation, or when replacing the wire rope in the air, to prevent the wire rope from coming off, Additional measures such as installing falling down prevention device may be necessary.

Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process (접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가)

  • Jaemin Woo;Dongjun Kim;Jihun Shin;Gihong Min;Chaekwan Lee;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.78-88
    • /
    • 2023
  • Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.

A Study on the Color Proofing CMS Development for the KOREA Offset Printing Industry (한국 오프셋 인쇄산업에 적합한 CMS 개발에 관한 연구)

  • Song, Kyung-Chul;Kang, Sang-Hoon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.25 no.1
    • /
    • pp.121-133
    • /
    • 2007
  • The CMS(color management system) software was to enable consistent color reproduction from original to reproduction. The CMS was to create RGB monitor and printer characterization profiles and then use the profiles for device independent color transformation. The implemented CMM(color management module) used the CIELAB color space for the profile connection. Various monitor characterization model was evaluated for proper color transformation. To construct output device profile, SLI(sequential linear interpolation) method was used for the color conversion from CMYK device color to device independent CIELAB color space and tetrahedral interpolation method was used for backward transformation. UCR(under color removal) based black generation algorithm was used to construct CIELAB to CMYK LUT(lookup table). When transforming the CIE Lab colour space to CMYK, it was possible to involve the gray revision method regularized in the brightness into colour transformation process and optimize the colour transformation by black generation method based on UCR technique. For soft copy colour proofing, evaluating several monitor specialism methods showed that LUT algorithm was useful. And it was possible to simplify colour gamut mapping by constructing both the look-up table and the colour gamut mapping algorithm to a reference table.

  • PDF

Development of Auto-Control Power Supply of ELID Electrolysis Speed for Metal-Bonded Grinding Wheel (금속결합제 연삭 숫돌의 ELID 전해속도 자동 조절장치 개발)

  • Shin, Gun-Hwi;Kwak, Tae-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.899-904
    • /
    • 2016
  • ELID grinding is an excellent technique for the mirror grinding of the variety of the advanced metallic or nonmetallic materials. The focus of this study is the development of an automatic-control electrolysis-speed device for the automation of the ELID-grinding process. For the development of the automatic-control electrolysis-speed device, analysis experiments regarding the ELID cycle and oxide-layer removal and creation were conducted according to a truing and dressing process. Also, a comparative experiment was conducted to confirm the variance of the electrolysis speed in accordance with changes of the voltage. The experiment results for the developed automatic-control electrolysis-speed device show that the developed device could control the electrolysis speed according to voltage changes through the use of the data that are monitored during the ELID-grinding process.

Remote Nozzle Blocking Device of RCS Pipe during Mid-Loop Operation in Nuclear Power Plants

  • Kang, Ki-Sig;Lee, Se-Yub;Chi, Ham-Chung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.571-576
    • /
    • 1996
  • Currently most nuclear power plants(NPPs) are adopted the mid-loop operation to minimize the overhaul period and save the operating cost. For mid-loop operation it is essential to install nozzle dam between RCS pipe and steam generator(SG). Because SG remains more highly contaminated with radioactive material than any other parts of the NPPs, the repairmen are very reluctant to carry out installing nozzle dam inside the SG. Until now, unfortunately, it appears that no practically applicable device was developed to provide the longstanding demand. Also the accidents have been reported by licenser event report during this operation mode due to loss of residual heat removal(RHR). The purpose of this paper is to conduct remotely blocking and disintegration of nozzle of a SG which has the highest radiation exposure during the maintenance in NPPs. The remote nozzle blocking device of a SG includes three bladders, hubs, air controller provisions to supply and contact air pressure into the bladders. This remote nozzle block device will give the larger operation margin to prevent the loss of RHR and minimize the radiation exposure dose to the repairman and shorten the overhaul periods.

  • PDF

Simple and Cost-Effective Method for Edge Bead Removal by Using a Taping Method

  • Park, Hyeoung Woo;Kim, H.J.;Roh, Ji Hyoung;Choi, Jong-Kyun;Cha, Kyoung-Rae
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1473-1478
    • /
    • 2018
  • In this study, we have developed a simple and cost-effective method to prevent edge bead formation by covering the edge of a chip-level substrate with heat-resistant tape during patterning using SU-8. Edge beads are a fundamental problem in photoresists and are particularly notable in high-viscosity fluids and thick coatings. Edge beads can give rise to an air gap between the substrate and the patterning mask during UV exposure, which results in non-uniform patterns. Furthermore, the sample may break since the edge bead is in contact with the mask. In particular, the SU-8 coating thickness of the chip-level substrates used in MEMS or BioMEMS may not be properly controlled because of the presence of edge beads. The proposed method to solve the edge bead problem can be easily and economically utilized without the need for a special device or chemicals. This method is simple and prevents edge bead formation on the sample substrate. Despite the small loss in the taping area, the uniformity of the SU-8 coating is improved from 50.9% to 5.6%.

The Removal of Algae and Phosphorus in Eutrophic Waters Using Various Filter Media (몇 가지 여재를 이용한 부영양수 내의 조류 및 인 제거효과)

  • Park, Chae-Hong;Park, Myung-Hwan;Choi, Dong-Ho;Lee, Joon-Heon;Lee, Myung-Hoon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.1
    • /
    • pp.102-109
    • /
    • 2012
  • In this study, the four different filter media (sponge, volcanic stone, activated carbon and magnesium hydroxide) were tested for the removal of algae and phosphorus in the two eutrophic water samples (natural water and artificial algal culture with BG-11 medium). These filter media were used in the column device as single or combined applications. The effect of the $Mg(OH)_2$ on phosphorus removal was examined using different particle sizes (<2 mm and >2 mm) and concentrations (0, 10, 50 and 100 g $L^{-1}$) of magnesium hydroxide. The removal efficiency of phosphate by magnesium hydroxide was increased with longer experimental time and higher concentration. However, there was no significant difference in the degree of phosphorus removal between any two particle sizes (1 mg P $L^{-1}$: F=0.109, P=0.685; 10 mg P $L^{-1}$: F=1.542, P=0.355). Among the four media, activated carbon showed the most potent effect on the removal of both algae and phosphorus. The highest removal efficiency of algae and phosphorus was obtained by combining four columns of each filter medium. Interestingly, integration of four filter columns showed higher removal efficiency than activated carbon alone. The highest removal efficiency by integrated filter columns seemed to be caused by a synergistic effect of combined activated carbon and magnesium hydroxide.