• Title/Summary/Keyword: Removal device

Search Result 413, Processing Time 0.033 seconds

Surgical Resection of Cardiac Hemangiosarcoma Using Articulated Surgical Stapler in a Dog

  • Woo-Jin Kim;Kyung-Min Kim;Won-Jong Lee;Chang-Hwan Moon;Hae-Beom Lee;Seong-Mok Jeong;Dae-Hyun Kim
    • Journal of Veterinary Clinics
    • /
    • v.41 no.1
    • /
    • pp.37-42
    • /
    • 2024
  • This case report discusses the successful surgical resection of cardiac hemangiosarcoma in a dog using an articulated surgical stapler. Cardiac tumors, particularly hemangiosarcomas, have a poor prognosis. Recommended treatment involves surgical removal of the primary tumor, along with chemotherapy. However, the use of staples for cardiac tumor resection has not yet been extensively documented in the veterinary literature. A 10-year-old dachshund with pericardial effusion underwent surgery to remove a right atrial mass. An articulated linear cutting stapler was used for tumor resection. The patient experienced chylothorax as a complication but recovered well. However, the patient later developed respiratory symptoms and died, most likely due to aspiration pneumonia. The surgical stapler provided stability, convenience, and a shorter surgical time during tumor resection. Surgical resection combined with chemotherapy improves the survival of dogs with cardiac hemangiosarcoma. The stability and adjustability of the stapling device make it advantageous for cardiac tumor resection. Although complications, such as chylothorax, can arise, appropriate management can lead to positive outcomes. This case report demonstrates the feasibility and safety of using an articulated surgical stapler for cardiac tumor resection in dogs. Insights from this case can guide future research and clinical practice.

Gamma/neutron classification with SiPM CLYC detectors using frequency-domain analysis for embedded real-time applications

  • Ivan Rene Morales;Maria Liz Crespo;Mladen Bogovac;Andres Cicuttin;Kalliopi Kanaki;Sergio Carrato
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.745-752
    • /
    • 2024
  • A method for gamma/neutron event classification based on frequency-domain analysis for mixed radiation environments is proposed. In contrast to the traditional charge comparison method for pulse-shape discrimination, which requires baseline removal and pulse alignment, our method does not need any preprocessing of the digitized data, apart from removing saturated traces in sporadic pile-up scenarios. It also features the identification of neutron events in the detector's full energy range with a single device, from thermal neutrons to fast neutrons, including low-energy pulses, and still provides a superior figure-of-merit for classification. The proposed frequency-domain analysis consists of computing the fast Fourier transform of a triggered trace and integrating it through a simplified version of the transform magnitude components that distinguish the neutron features from those of the gamma photons. Owing to this simplification, the proposed method may be easily ported to a real-time embedded deployment based on Field-Programmable Gate Arrays or Digital Signal Processors. We target an off-the-shelf detector based on a small CLYC (Cs2LiYCl6:Ce) crystal coupled to a silicon photomultiplier with an integrated bias and preamplifier, aiming at lightweight embedded mixed radiation monitors and dosimeter applications.

Physical Seed Treatment Techniques for Germination Enrichment and Seed Sterilization (발아증진 및 소독을 위한 물리적 방법을 이용한 종자처리 기술)

  • Si-Yong Kang
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.199-207
    • /
    • 2023
  • Since seeds can be directly used as food resources as well as for crop cultivation or preservation of genetic resources, it is essential to develop high-quality seed processing technology to increase agricultural productivity. Seed treatment means processing technologies of seeds through physical or chemical treatment processes from after harvesting seeds to before sowing of seeds to improve germination and growth rate, durability, and immunity, etc. Since chemical seed treatment technology using pesticides or plant growth regulators has problems of environmental pollution and human toxicity, it is desired to develop an alternative technology. As a physical seed treatment method, various technologies such as ionizing radiation, plasma, microwave, and magnetic field are being developed, and some of them are being used practically. In this paper, I will summarize the mechanism of seed priming and disinfection, and the advantages and disadvantages of application, focusing on these physical seed treatment methods. Low dose or moderate intensity ionizing radiation, microwave, low-temperature plasma, and magnetic field treatments often promoted seed germination and seedling growth. However, effective removal of direct seed pathogens at these treatment intensities appears to be difficult. And it has been shown that relatively high-dose electron beam treatment using low-energy electron beams kills microorganisms on the seed surface and hull layer while not damaging the inner tissue of the seed, and is also effectively used for seed treatment on a commercial scale. In order to put the physical seed treatment technology to practical use in Korea, it is necessary to develop an economical scale treatment device along with the development of individual treatment technology to each crop.

The Correlation between Critical Micelle Concentration/Surface of Contact Lens Care Solutions Tension and Their Cleaning Efficacy (콘택트렌즈 관리용액의 미셀임계농도 및 표면장력과 세척력 간의 상관관계)

  • Byun, Hyun Young;Sung, Hyung Kyung;Moon, Joon Sik;Lee, A Young;Kwon, Se Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • Purpose: The present study was aimed to figure out the correlation amongst the evaluation methods for critical micelle concentration, surface tension and protein cleaning efficacy to evaluate cleaning efficacy of contact lens care products. Methods: The critical micelle concentration of surfactants and the actual concentration of surfactants in contact lens care solutions were investigated by employing references published and related information. Surface tension of contact lens care solutions was measured by surface tension device at $25{\pm}1^{\circ}C$, and contact lenses made of lotrafilcon A, comfilcon A and balafilcon A were washed with contact lens care solutions after the incubation in artificial tears for 14 days and their cleaning efficacy was compared. Results: Among the 22 contact lens care products, 9 products provided the label of the concentration of surfactant, and 7 products showed higher concentration of surfactant than the critical micelle concentration reported in references. As a result of measuring surface tension, the surface tension of lens care products for soft contact lens was generally lower than other care products. When examined the removal effect of protein deposited on lens surface, it was known that the care products having lower surface tension showed higher protein removal efficiency. Conclusions: The surface tension is low when surfactant concentration in contact lens care solutions is high, and the removal effect of protein deposited is accordingly increased with the decrease of surface tension. Thus, these indicate the correlation amongst the evaluation methods for cleaning efficacy.

The Effects of Operational and Mechanical Factors on the Performance of Rice-Husk Furnace (왕겨연소기(燃燒機)의 성능(性能)에 영향(影響)을 마치는 설계(設計) 및 작동인자(作動因子)에 관(關)한 연구(硏究))

  • Park, Seung Je;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.39-48
    • /
    • 1983
  • This study was performed to obtain the basic data which could be used for the modification of the manual center-burner-type rice-husk furnace into a small scale automatic type for the multi-purpose use in the farm. For this purpose, first, the utilization feasibility of the rice-husk furnace in the farm was analyzed briefly in aspects of available amount of rice-husk for the fuel, annual operation time and replaceble amount of residential heating energy with rice-husk in the farm. For the experiment a prototype furnace geared with an automatic feeding device was fabricated, and feed rate, mold size and chimney height were changed to investigate the combustion efficiency of rice-husk and thermal efficiency of the furnace. Also, optimum and limiting operational factors were observed in each treatments. The results obtained are summarized as follows. 1. If the rice-husk is intensively used for residential heating in the farm for winter season, on an average 51 percent of the total heating energy can be replaced with the rice-husk. Therefore, development of a small scale automatic rice-husk furnace was recognized to be feasible. 2. The operational condition depending on husk-feed rates was very important factor for successive steady burning operation of the given furnace. When the feed-rate was 1.5 kg/hr, the top of the burning zone should be kept at the position about 55 cm from the bottom of the combustion chamber with the periodic removal of ash (termed as steady state position), which was 18 cm above the mold waist. When the feed rates were 2.4 kg/hr and 3.0 kg/hr, the steady state position was at about 4 cm above the mold waist. 3. The mold size affected inflow rate of air into the furnace and consequently CO content in the exhaust gas. The relatively bigger mold gave positive effect on the air-inflow rate. 4. When the husk-feed rates were 1.5 kg/hr, 2.4 kg/hr, 3.0 kg/hr, the combustion efficiencies of the rice-husk were 98.5%, 97.4% and 95.0%, the thermal efficiencies of the furnace were 93.4%, 93.2% and 87.6%, and CO content in the exhaust gas were 1.21%, 1.03%, and 2.43%, respectively. The air-inflow rates were decreased with the increase of feed rates. When the amount of excess air was 30-40%, the CO content in the exhaust gas was at the minimum level. 5. When the chimney height was lowered from 260 cm to 96 cm, the air-inflow rate was slightly decreased, but the average temperature in the combustion chamber, CO content in the exhaust gas and combustion and thermal efficiencies were not changed significantly. 6. The incidental problems associated with the protytype furnace were accumulation of the ash inside the mold, accumulation of the cinder between the outer-drum of the furnace and the combustion chamber wall, and accumulation of the cinder in the chimney.

  • PDF

Treatment of Class II Furcation Involvements in Humans with Bioabsorbable Guided Tissue Regeneration Barriers (2급 치근분지부 병소에서의 생분해성 차폐막의 효과)

  • Lee, Hak-Churl;Han, Seoung-Min;Seol, Yang-Jo;Lee, Chul-Woo;Um, Heung-Sik;Chang, Beom-Suk;Chung, Chong-Pyoung;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.539-553
    • /
    • 1999
  • The purpose of this 6-months study was to compare the clinical and radiographic outcomes following guided tissue regeneration treating human mandibular Class II furcation defects with a bioabsorbable BioMesh barrier(test treatment) or a nonabsorbable ePTFE barrier(control treatment). Fourteen defects in 14 patients(mean age 44 years) were treated with BioMesh barriers and ten defects in 10 patients(mean age 48 years) with ePTFE barriers. After initial therapy, a GTR procedure was done. Following flap elevation, root planing, and removal of granulation tissue, each device was adjusted to cover the furcation defect. The flaps were repositioned and sutured to complete coverage of the barriers. A second surgical procedure was performed at control sites after 4 to 6 weeks to remove the nonresorbable barrier. Radiographic and clinical examinations(plaque index, gingival index, tooth mobility, gingival margin position, pocket depth, clinical attachment level) were carried out under standardized conditions immediately before and 6 months after surgery. Furthermore, digital subtraction radiography was carried out. All areas healed uneventfully. Surgical treatment resulted in clinically and statistically equivalent changes when comparisons were made between test and control treatments. Changes in plaque index were 0.7 for test and 0.4 for control treatments; changes in gingival index were 0.9 and 0.5. In both group gingival margin position and pocket depth reduction was 1.0mm and 3.0mm; clinical attachment level gain was 1.9mm. There were no changes in tooth mobility and the bone in radiographic evaluation. No significant(p${\leq }$0.05) difference between the two membranes could be detected with regard to plaque index, gingival index, gingival margin position, pocket depth, and clinical attachment level. In conclusion, a bioabsorbable BioMesh membrane is effective in human mandibular Class II furcation defects and a longer period study is needed to fully evaluate the outcomes.

  • PDF

The surface kinetic properties of $ZrO_2$ Thin Films in dry etching by Inductively Coupled Plasma

  • Yang-Xue, Yang-Xue;Kim, Hwan-Jun;Kim, Dong-Pyo;Um, Doo-Seung;Woo, Jong-Chang;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.105-105
    • /
    • 2009
  • $ZrO_2$ is one of the most attractive high dielectric constant (high-k) materials. As integrated circuit device dimensions continue to be scaled down, high-k materials have been studied more to resolve the problems for replacing the EY31conventional $SiO_2$. $ZrO_2$ has many favorable properties as a high dielectric constant (k= 20~25), wide band gap (5~7 eV) as well as a close thermal expansion coefficient with Si that results in good thermal stability of the $ZrO_2/Si$ structure. In order to get fine-line patterns, plasma etching has been studied more in the fabrication of ultra large-scale integrated circuits. The relation between the etch characteristics of high-k dielectric materials and plasma properties is required to be studied more to match standard processing procedure with low damaged removal process. Due to the easy control of ion energy and flux, low ownership and simple structure of the inductively coupled plasma (ICP), we chose it for high-density plasma in our study. And the $BCl_3$ included in the gas due to the effective extraction of oxygen in the form of $BCl_xO_y$ compound In this study, the surface kinetic properties of $ZrO_2$ thin film was investigated in function of Ch addition to $BCl_3/Ar$ gas mixture ratio, RF power and DC-bias power based on substrate temperature. The figure 1 showed the etch rate of $ZrO_2$ thin film as function of gas mixing ratio of $Cl_2/BCl_3/Ar$ dependent on temperature. The chemical state of film was investigated using x-ray photoelectron spectroscopy (XPS). The characteristics of the plasma were estimated using optical emission spectroscopy (OES). Auger electron spectroscopy (AES) was used for elemental analysis of etched surface.

  • PDF

Enhancement of Coagulation and Flocculation Efficiencies by Ultrasonic Chemical Spray Nozzle I (초음파 약품분사노즐을 이용한 응집효율 향상 I)

  • Kim, Jin-Kook;Cho, Soon-Haing;Ha, Dong-Yun;Koh, Jae-Seok;Kim, Yong-Hyun;Choi, Seung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • To establish low-cost and high efficiency water treatment process, feasibility of applying ultrasonic spray nozzle for chemical injection was evaluated. Ultrasonic spray nozzle was manufactured using piezoelectric ceramics. Treatment efficiencies of contaminants by ultrasonic spray nozzle were compared with conventional chemical mixing such as back-mixing. It was found out that the rate of chemical diffusion rate by ultrasonic spray nozzle was faster than by back-mixing method. Removal efficiencies of various contaminants, such as turbidity, organics and microorganism by ultrasonic spray nozzle were also higher than by back-mixing method. By adapting ultrasonic spray nozzle in coagulant injection process, it can be prevented that the decline of treatment efficiency by coagulant overdose. The amount of coagulant can be reduced by applying ultrasonic spray nozzle in water treatment. Along with these advantages chemical mixing chamber is not required if ultrasonic spray nozzle is adapted. From these results, it can be concluded that chemical injection by ultrasonic spray nozzle is an economical and highly efficient device for coagulant mixing.

EFFECTS OF PTERYGOMAXILLARY SEPARATION ON SKELETAL AND DENTAL CHANGES FOLLOWING SURGICALLY-ASSISTED RAPID MAXILLARY EXPANSION (외과적 급속상악확장술시 익돌상악 접합부의 분리 유무에 따른 치열궁 변화)

  • Han, In-Ho;An, Jin-Suk;Gu, Hong;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.4
    • /
    • pp.320-328
    • /
    • 2006
  • Purpose: The aim of this study was to evaluate the effects of pterygomaxillary separation on dimensional changes of dental arch following surgically-assisted rapid maxillary expansion (SARME). Patients and Methods: Eighteen adults who had been treated by SARME for transverse maxillary deficiency from May 2000 to August 2005 were evaluated. Thirteen patients (Group 1) were treated with subtotal Le Fort I osteotomy including pterygomaxillary separation and anterior midpalatal osteotomy. The same operation was performed in five patients (Group 2) except pterygomaxillary separation. Dental study casts were taken before operation and after removal of expansion device. And then, skeletal and dental parameters were measured pre- and post-operatively. Results: 1. Changes of mean interdental width 1) In group 1, mean maxillary interdental width was increased 70%($47{\sim}99%$), 95%($84{\sim}115%$), and 77%($57{\sim}94%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 2) In group 2, mean maxillary interdental width was increased 77%($59{\sim}100%$), 78%($45{\sim}107%$), and 86%($57{\sim}116%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 3) There was a statistical difference between the change of interdental width of group 1 and group 2 at first premolar(p<0.05). 2. Changes of mean interalveolar width 1) In group 1, mean maxillary alveolar bone width was increased 66%($42{\sim}84%$), 74%($42{\sim}104%$), and 57%($31{\sim}78%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 2) In Group 2, mean maxillary alveolar bone width was increased 73%($55{\sim}98%$), 67%($36{\sim}89%$), and 59%($48{\sim}73%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 3) There were no statistical differences between group 1 and group 2 at each teeth area. Conclusion: These results suggest that SARME without pterygomaxillary separation may allow the relatively equal expansion at both anterior and posterior teeth area and most amounts of maxillary interdental expansions were acquired with the expansion of the maxilla by SARME.

Efficacy of sonic-powered toothbrushes for plaque removal in patients with peri-implant mucositis

  • Lee, Jungwon;Lim, Jong Heun;Lee, Jungeun;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Ku, Young;Lee, Yong-Moo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.56-61
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the effectiveness of powered toothbrushes for plaque control in patients with peri-implant mucositis, in comparison with manual toothbrushes. Methods: This randomized, prospective, controlled, clinical parallel study compared the efficacy of manual and powered toothbrushes for plaque control in implant restorations. Patients with bleeding on probing, no residual pocket depth (as indicated by a pocket probing depth ${\geq}5mm$), and no radiological peri-implant bone loss were eligible for this study. Patients were requested to complete a questionnaire describing their oral hygiene habits. The duration and frequency of tooth brushing were recorded by subjects in order to assess their compliance. Clinical parameters, including the modified plaque index (mPI), the modified sulcus bleeding index (mSBI), and clinical photographs (buccal and lingual views) were recorded at baseline and at one-month and two-month follow-up visits. Results: Statistically significant differences between patients who used manual toothbrushes and those who used powered toothbrushes were found regarding the frequency of tooth brushing per day and the duration of brushing at one-month and two-month follow-up visits, while no statistically significant differences were found relating to other oral hygiene habits. A statistically significant difference in patient compliance for tooth brushing was found at one month, while no difference was found at two months. Statistically significant decreases in the mPI and the mSBI were observed in both groups from baseline to the one- and two-month follow-ups. The overall reduction of these parameters was not significantly different between the two groups, except for mPI reduction between baseline and one month of follow-up. Conclusions: Sonic-powered toothbrushes may be a useful device for plaque control in patients with peri-implant mucositis.