• Title/Summary/Keyword: Removal device

Search Result 413, Processing Time 0.024 seconds

Development of a precision machining process for the outer cylinder of vacuum roll for film transfer (필름 이송을 위한 진공 롤 외통의 정밀가공 공정개발)

  • Eui-Jung Kim;Ho-Sang Lee
    • Design & Manufacturing
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2024
  • Unlike the roll-to-roll process that uses a steel roll and a nip roll, a vacuum roll can hold and transfer a thin film using a single roll. To precisely manufacture a vacuum roll, a thin outer cylinder must be machined, which is assembled on the outside of the roll and contacts the film via vacuum pressure. In this study, the effects of jaw width and chucking force on the deformation of the outer cylinder during the turning process were investigated using analysis, and a precision machining and burr removal process was developed. The deformation of the outer cylinder decreased almost linearly with increasing jaw width and increased with higher chucking force and larger cylinder diameter. Additionally, the deflection due to the weight of the outer cylinder was approximately three times greater than that caused by film tension. For the machined outer cylinder, a burr removal experiment was conducted, and concentricity and cylindricity were measured. Using a device that removes burrs by rotating a wheel connected to the main shaft at high speed, it was found that burrs generated on the inner diameter could be removed very efficiently. On the vacuum side, the concentricity errors of the inner and outer diameters were 0.015 mm and 0.014 mm, respectively, and on the opposite side, they were 0.006 mm and 0.010 mm, respectively. Additionally, the measurement of Total Indicator Runout (TIR) according to the angle showed that the maximum cylindricity of the outer and inner diameters was 0.02 mm and 0.025 mm, respectively. Finally, through burr-height measurement at the hole boundary, it was found that the heights were within 0.05 mm.

The Effects of Occupational Therapy Intervention Using Fully Immersive Virtual Reality Device on Upper Extremity Function of Patients With Chronic Stoke: Case Study (완전 몰입형 가상현실 기기를 이용한 작업치료 중재가 만성 뇌졸중 환자의 상지기능에 미치는 영향: 사례연구)

  • Han, Soul;Yoo, Eun-Young
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.2
    • /
    • pp.17-27
    • /
    • 2018
  • Objective : The purpose of this study was to investigate the effect of occupational therapy intervention using a fully immersive virtual reality device on the upper extremity function of patients with chronic stroke. Methods : This study used a single subject (ABA) design. The study subjects was a chronic stroke patient with left lateral deviation. Four baseline periods, 12 intervention periods, and 4 baseline regression periods were performed for a total of 20 sessions for 10 weeks. OT intervention with a fully immersive virtual reality device was used every 30 minutes. BBT and WMFT evaluations were performed at each session and the results were displayed in a line graph. Results : The patient's upper limb function has improved. During baseline recurrence, efficacy of treatment was confirmed after removal of intervention, but no significant changes were observed. Conclusion : It has been found that OT intervention with a fully immersive virtual reality device for upper limb function in chronic stroke patients is an effective intervention. However, the effectiveness of maintaining treatment is not important, so we need to develop an easy-to-use home intervention program.

Updates of Nursing Practice Guideline for Intravenous Infusion (정맥주입요법 간호실무지침 개정)

  • Gu, Mee Ock;Cho, Yong Ae;Eun, Young;Jung, Ihn Sook;Kim, Hyun Lim;Yoon, Hee Sook;Kim, Eun Hyun;Yoon, Ji Hyun;Chang, Hee Kyung
    • Journal of Korean Clinical Nursing Research
    • /
    • v.23 no.3
    • /
    • pp.361-375
    • /
    • 2017
  • Purpose: This study was conducted to update the existing nursing practice guideline for intravenous infusion guidelines according to the evidence-based practice guideline in South Korea. Methods: Guideline update process was performed using 22 steps according to the manuals developed by NICE and SIGN. Results: Updated nursing practice guidelines for the intravenous infusion were consisted of 23 domains and 322 recommendations. The number of recommendations in each domain were 4 for general instruction, 12 for vascular access device selection, 20 for site selection, 9 for insertion, 54 for stabilization, 21 for maintaining patency, 4 for blood sampling, 33 for exchange and removal, 28 for add-on device selection, 28, 72 for infusion related complications, 56 for infusion therapies, 7 for education, and 2 for documentation and report. There were 15.9% of A, 30.2% of B, 53.9% of C in terms of grade recommendations. A total of 178 (51.6%) recommendations were newly developed and 24 previous recommendations have been deleted. Conclusion: Updated nursing practice guideline for intravenous infusion was expected to be an evidence-based practice guideline for intravenous infusion in South Korea. This guideline is suggested to be disseminated to clinical nursing settings nationwide to improve the efficiency of intravenous infusion practice.

A Study on the Emission Characteristics of Mercury in Municipal and Industrial Waste Incinerators (폐기물소각시설의 수은배출특성 연구)

  • Seok Kwangseol;Hong Jihyung;Lee Sukjo;Lee Daegyun;Kim Daigon;Park Jihyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.205-213
    • /
    • 2004
  • The emission characteristics of mercury in waste incinerators were investigated to get basic data for the policy development on the emission reduction of mercury (Hg). For the study several important factors were analysed from 4 incinerators such as mercury concentration, emission factors and removal rate for control devices. The results are listed below. Mercury concentrations in the flue gas were 0.39~5.96 $\mu\textrm{g}$/S㎥ in MWI and 2.5~8.8 $\mu\textrm{g}$/S㎥ in IWI. The distributions of gaseous and particulate mercury in flue gas were above 99% and below 1 %, respectively. Therefore, in order to remove mercury effectively, it is important to control the gaseous mercury. Mercury concentrations in fly ash collected from control device were found as 16.2~35.6 mg/kg- ash in FF of MWI. Also mercury concentrations at the front and back point of control device of MWI were 33.45~62.65 $\mu\textrm{g}$/S㎥ and 0.88~3.49 $\mu\textrm{g}$/S㎥, respectively. Emission factors were estimated as 3.67~11.67 mg/ton in FF, 2.6~24.5 mg/ton in MWI with SNCR, SDR and FF, 54.9~192.7 mg/ton in IWI with Cyclone and FF. Emissions from Municipal Waste Incinerator were found both in minimum and maximum ranges. Annual mercury emissions emitted from MWI was estimated as 20.0 kg (6.0~33.9 kg).

Effects of Days Open on the Subsequent Reproductive Performance Following to CIDR-Based Estrus Synchronization in Lactating Dairy Cows

  • Kang, Hyun-Gu;Kim, Ill-Hwa
    • Journal of Embryo Transfer
    • /
    • v.26 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to evaluate the effects of days open on subsequent reproductive performance following to estrus synchronization in the 114 lactating dairy cows. The animals were divided into two groups according to the time of estrus synchronization; viz, ${\leq}$ 85 days, and > 85 days postpartum, respectively. The estrus synchronization protocol consisted of insertion of a controlled internal drug release (CIDR) device containing 1.9 g progesterone with an injection of 250 ${\mu}g$ gonadorelin (Day 0), an injection of $PGF_2{\alpha}$ and removal of the device on Day 7, an injection of 250 ${\mu}g$ GnRH on Day 9, and TAI 17 h later. Pregnancy diagnosis was determined at 30 to 60 days after TAI using both ultrasonography and rectal palpation. The body condition score (BCS) gradually increased over the postpartum period. In estrus synchronized cows until 85 days, conception rate on first service, number of service per conception, interval from estrus synchronization to conception, and interval from calving to conception were not significantly different among two farms (P>0.05). In estrus synchronized cows after 85 days postpartum, conception rate on first service, number of service per conception and interval from calving to conception were significantly different ($P{\leq}0.05$) between herds A and B (26.8 vs 50.0%; $2.1{\pm}1.35$ vs $1.37{\pm}0.54$ times, $237.3{\pm}97.8$ vs $164.7{\pm}69.3$ days, respectively). In estrus synchronized cows after 85 days postpartum interval from estrus synchronization to conception was greater (P<0.01) in herd B than in herd A ($63.6{\pm}57.4$ vs $26.1{\pm}24.9$). These results indicate that the time of estrus synchronization for maximized the reproductive performance is before 85 days postpartum and feeding and management is important factor for high reproductive performance.

Cyberspace Coordinate Create for Augmented Reality (증강현실을 위한 가상 공간좌표 생성)

  • Ban, KyeongJin;Ryu, NamHoon;Kim, KyeongOk;Han, JeaJung;Kim, EungKon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.765-769
    • /
    • 2009
  • The Augmented Reality of existing for the interaction which the object and background is smooth used the data glove or marker. It is inconvenient to a use and it occurs the result of immersion feeling decrease. Immersion it will wind from Augmented Reality and the hazard which it strengthens the removal of the additional entry device which stands is necessary. It recognizes the space coordinates which is accurate even from the condition where the hazard marker which will reach does not attach in necessity. Immersion feeling improvement from Augmented Reality wearing the hazard additional entry device it proposes the space coordinate creation technique of the virtuality description below for a interaction without from the present paper. The method which is proposed the image which it acquires the object of virtuality reflected at 2D space and the characteristic line about under extracting the space coordinate which reflects about under calculating it reflected. The application is possible in markerless Augmented Reality and the mobile Augmented Reality.

  • PDF

Brace Compression for Treatment of Pectus Carinatum

  • Jung, Joonho;Chung, Sang Ho;Cho, Jin Kyoung;Park, Soo-Jin;Choi, Ho;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.45 no.6
    • /
    • pp.396-400
    • /
    • 2012
  • Background: Surgery has been the classical treatment of pectus carinatum (PC), though compressive orthotic braces have shown successful results in recent years. We propose a non-operative approach using a lightweight, patient-controlled dynamic chest-bracing device. Materials and Methods: Eighteen patients with PC were treated between July 2008 and June 2009. The treatment involved fitting of the brace, which was worn for at least 20 hours per day for 6 months. Their degree of satisfaction (1, no correction; 4, remarkable correction) was measured at 12 months after the initiation of the treatment. Results: Thirteen (72.2%) patients completed the treatment (mean time, $4.9{\pm}1.4$ months). In patients who completed the treatment, the mean overall satisfaction score was $3.73{\pm}0.39$. The mean satisfaction score was 4, and there was no recurrence of pectus carinatum in patients who underwent the treatment for at least 6 months. Minimal recurrence of pectus carinatum after removal of the compressive brace occurred in 5 (38.5%) patients who stopped wearing the compressive brace at 4 months. Conclusion: Compressive bracing results in a significant improvement in PC appearance in patients with an immature skeleton. However, patient compliance and diligent follow-up appear to be paramount for the success of this method of treatment. We currently offer this approach as a first-line treatment for PC.

Multi-Modal User Distance Estimation System based on Mobile Device (모바일 디바이스 기반의 멀티 모달 사용자 거리 추정 시스템)

  • Oh, Byung-Hun;Hong, Kwang-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • This paper present the multi-modal user distance estimation system using mono camera and mono microphone basically equipped with a mobile device. In case of a distance estimation method using an image, we is estimated a distance of the user through the skin color region extraction step, a noise removal step, the face and eyes region detection step. On the other hand, in case of a distance estimation method using speech, we calculates the absolute difference between the value of the sample of speech input. The largest peak value of the calculated difference value is selected and samples before and after the peak are specified as the ROI(Region of Interest). The samples specified perform FFT(Fast Fourier Transform) and calculate the magnitude of the frequency domain. Magnitude obtained is compared with the distance model to calculate the likelihood. We is estimated user distance by adding with weights in the sorted value. The result of an experiment using the multi-modal method shows more improved measurement value than that of single modality.

A Study on sub 0.1$\mu\textrm{m}$ ULSI Device Quality Using Novel Titanium Silicide Formation Process & STI (새로운 티타늅 실리사이드 형성공정과 STI를 이용한 서브 0,1$\mu\textrm{m}$ ULSI급 소자의 특성연구)

  • Eom, Geum-Yong;O, Hwan-Sul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.1-7
    • /
    • 2002
  • Deep sub-micron bulk CMOS circuits require gate electrode materials such as metal silicide and titanium silicide for gate oxides. Many authors have conducted research to improve the quality of the sub-micron gate oxide. However, few have reported on the electrical quality and reliability of an ultra-thin gate. In this paper, we will recommend a novel shallow trench isolation structure and a two-step TiS $i_2$ formation process to improve the corner metal oxide semiconductor field-effect transistor (MOSFET) for sub-0.1${\mu}{\textrm}{m}$ VLSI devices. Differently from using normal LOCOS technology, deep sub-micron CMOS devices using the novel shallow trench isolation (STI) technology have unique "inverse narrow-channel effects" when the channel width of the device is scaled down. The titanium silicide process has problems because fluorine contamination caused by the gate sidewall etching inhibits the silicide reaction and accelerates agglomeration. To resolve these Problems, we developed a novel two-step deposited silicide process. The key point of this process is the deposition and subsequent removal of titanium before the titanium silicide process. It was found by using focused ion beam transmission electron microscopy that the STI structure improved the narrow channel effect and reduced the junction leakage current and threshold voltage at the edge of the channel. In terms of transistor characteristics, we also obtained a low gate voltage variation and a low trap density, saturation current, some more to be large transconductance at the channel for sub-0.1${\mu}{\textrm}{m}$ VLSI devices.

Timed Artificial Insemination or Embryo Transfer using CIDR, Estradiol Benzoate and Prostaglandin $F_{2{\alpha}}$ for the Rebreeding of Korean Native Donor Cattle

  • Son, Dong-Soo;Choe, Chang-Yong;Cho, Sang-Rae;Choi, Sun-Ho;Kim, Hyun-Jong;Lee, Je-In;Kim, Ill-Hwa
    • Journal of Embryo Transfer
    • /
    • v.23 no.2
    • /
    • pp.81-86
    • /
    • 2008
  • This study compared the pregnancy rates of Korean native donor cattle after either a timed artificial insemination (TAI) or embryo transfer (TET) following the synchronization of ovulation using a controlled internal drug release (CIDR) device together with estradiol benzoate (EB) and prostaglandin $F_{2{\alpha}}$ ($PGF_{2{\alpha}}$). Fifty five cows and 8 heifers which had been previously used for embryo production were assigned to two treatments: (1) Thirty-two cattle received a CIDR device and 2 mg EB (Day 0), 25 mg $PGF_{2{\alpha}}$ injection at the time of CIDR removal on Day 7, and 1 mg EB injection on Day 8. All of the cattle received a TAI 30 h (Day 9) after the second EB injection (TAI group). (2) Thirty-one cattle received the same hormonal treatments as in the TAI group. The cattle with corpus luteum (CL) received a TET on Day 16 using frozen-thawed embryos (TET group). Ultrasonographic observations demonstrated that the proportion of cattle with synchronized ovulation on Day 10 and the concomitant formation of new CL on Day 13 did not differ between groups (p>0.05); the overall mean rates were 65.1 and 73.0%, respectively. The conception and pregnancy rates did not differ (p>0.05) between the TAI (12.5% and 12.5%) and TET groups (13.0% and 9.7%), respectively. We conclude that the pregnancy rate following TAI or TET in Korean native donor cattle was poor, which might be due in part to a poor synchrony of ovulation and concomitant CL formation.