• Title/Summary/Keyword: Removal capacity

Search Result 1,109, Processing Time 0.03 seconds

A Experimental Study of Electrokinetics and Enhanced Process with Kaolin Specimen Contaminated with Heavy metals (중금속으로 오염된 카올린의 Electrokinetic 처리와 효율증강에 관한 연구)

  • 정방미;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.241-246
    • /
    • 1999
  • In this research, electrokinetic remediation test was experimented with contaminated kaoline specimen at below, above the cation-exchange capacity of the mineral. The changes of the flow in electro-osmosis with open electrodes and current were presented, and lead removal results were evaluated through the extraction test. As a result, it was showed that removal efficiency was 20-30%, 67-87% In the anode As lead transport continues, the lead precipitation within a narrow zone very close to the cathode can go significantly high. This high lead precipitation near the cathode could block the flow path, decrease the conductivity, and thus the electroosmotic flow. The net effect will cause a decrease in the efficiency of electrokinetic processing. Therefore, in this study, citric acid and surfactant solution was used at the cathode as enhancement techniques.

  • PDF

Impact of Current Density, Operating Time and pH of Textile Wastewater Treatment by Electrocoagulation Process

  • Hossain, Md. Milon;Mahmud, Md. Iqbal;Parvez, Md. Shohan;Cho, Haeng Muk
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.157-161
    • /
    • 2013
  • Treatment of textile wastewater by the electrocoagulation (EC) process is being investigated by this experimental study. The objective of this experiment is to observe the efficiency of the EC process in removing chemical oxygen demand (COD) and turbidity. In this experiment an iron electrode is used in the EC process, and different working parameters such as pH, current density and operating time were studied in an attempt to achieve a higher removal capacity. The results show that the maximum COD removal occurred at neutral pH at operating time 30 min. COD and turbidity removal reaches at maximum, with optimum consumption of electrodes, between current density 85-95 $A/m^2$, and only trace amounts of metals were determined in the EC treated effluent.

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.

Equilibrium modeling for adsorption of NO3- from aqueous solution on activated carbon produced from pomegranate peel

  • Rouabeh, I.;Amrani, M.
    • Advances in environmental research
    • /
    • v.1 no.2
    • /
    • pp.143-151
    • /
    • 2012
  • Nitrate removal from aqueous solution was investigated using $ZnCl_2$ and phosphoric acid activated carbon developed from pomegranate peel with particle size 0.4 mm. Potassium nitrate solution was used in batch adsorption experiments for nitrate removal from water. The effects of activated carbon dosage, time of contact, and pH were studied. The equilibrium time was fond to be 45 min. Two theoretical adsorption isotherms namely Langmuir and Freundlich were used to describe the experimental results. The Langmuir fit the isotherm with the theoretical adsorption capacity ($q_t$) was fond 78.125 mg g-1. Adsorption kinetics data were modeled using the pseudo-first, pseudo-second order, and intraparticle diffusion models. The results indicate that the second-order model best describes adsorption kinetic data. Results show activated carbon produced from pomegranate is effective for removal of nitrate from aqueous solution.

Vapor Phase Mercury Removal by Sulfur Impregnated Activated Carbons and Sulfur Impregnation Protocol

  • Lee, Si-Hyun;Cha, Sun-Young;Park, Yeong-Seong
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.37-43
    • /
    • 2001
  • Mercury has been identified as a potential health and environmental hazardous material. Activated carbon adsorption offers promising potential for the control of mercury emissions, and sulfur impregnated (sulfurized) activated carbons has been shown to be an effective sorbent for the removal of vapor phase $Hg{\circ}$ from sources. In this work, vapor phase mercury adsorption by sulfur impregnated activated carbons were investigated. Sulfur impregnated activated carbons were made by variation of impregnation temperature, and the comparison of adsorption characteristics with commercial virgin and sulfurized carbons were made. Factors affecting the adsorption capacity of virgin and sulfurized activated carbons such as pore characteristics, functional groups and sulfur impregnation conditions were discussed. It was found that the sulfur allotropes plays a critical role in adsorption of mercury vapor by sulfurized activated carbons.

  • PDF

Dynamic Response of Reinforced Concrete Beams Following Instantaneous Removal of a Bearing Column

  • Tian, Ying;Su, Youpo
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.1
    • /
    • pp.19-28
    • /
    • 2011
  • This paper documents an experimental study of dynamic response of reinforced concrete beams following instantaneous removal of a bearing column. Four half-scale specimens representing two-span beam bridging across the removed column were tested. The test boundary conditions simulated rotational and longitudinal restraints imposed on a frame beam by the neighboring structural components. The gravity loads were simulated by attaching mass blocks on the beams at three locations. Dynamic loading effects due to sudden removal of a column were simulated by quickly releasing the supporting force at the middle of the specimens. The experimental study investigated the load-carrying capacity of beams restrained longitudinally at the boundaries and dynamic impact on forces. The tests confirmed the extra flexural strength provided by compressive arch action under dynamic loading. The tests also indicated that the dynamic amplification effects on forces were much lower than that assumed in the current design guideline for progressive collapse.

Neutralization and removal of heavy metal ions in Plating wastewater utilizing Oyster Shells (굴껍질을 이용한 도금폐수의 중화 및 중금속 이온 제거)

  • 성낙창;김은호;김정권;김형석
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.81-87
    • /
    • 1996
  • The purpose of this research is to examine the utilization of oyster shells for neutralization and removal of heavy metal ions in plating wastewater, because oyster shells have been known to be very porous, to have high specific surface area and to have alkaline minerals such as calcium and magnesium. The results obtianed from this research showed that oyster shells had a buffer capacity to neutralize an acidic.alkali system in plating wastewater. Generally, it could be showed that the removal efficiencies of heavy metal ions were very influenced by reaction times and oyster shell dosages. In point of ocean waste, if oyster shells substituted for a valuable adsorbent such as actviated carbon, they could look forward to an expected economical effect.

  • PDF

Removal of Alkali Odors using Impregnated ACFs (첨착 ACF를 이용한 염기성 악취물질의 제거)

  • 김기환;김덕기;최봉각;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.92-97
    • /
    • 1998
  • Malodorous gases give discomfort and harm to laborers and residential neighborhoods and therefore, the removing odor materials emitted from plants and industrial facilities is important subject. The main ingredients of alkali odor are $NH_3$ and $CE_3SH$. The adsorption characteristics of odors were studied using four different activated carbon fibers(ACF) and active carbon(AC). Alkali odor was removed by using ACF impregnated with $H_3PO_4$ and $H_2SO_4$ and treated with $HNO_3$ and NaOH. The experimental result showed that ACF has a higher removal efficiency than AC. The adsorption capacity was increased with the impregnation and surface treatment, and $H_2SO_4$ was the best impregnant for the removal of alkali odor.

  • PDF

The Comparison of Disinfection Technologies for Managing Antibiotic Resistance ; Chlrorination, Ozonation and Electron Beam (항생제 내성 제어를 위한 소독 기법간의 비교 ; 염소, 오존 및 전자빔)

  • Oh, Junsik;Kim, Sungpyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.797-803
    • /
    • 2013
  • Recently, a number of countries are now considering the reuse of effluents from wastewater treatment for various water applications. To improve the reuse of wastewater effluent, the development of appropriate micro-pollutant removal technology is necessary. Although several researche have been studied for removing micro-pollutants in water, little study has been conducted for the removal of emerging contaminant such as antibiotic resistant genes (ARGs) by disinfection processes. Therefore, the aim of this study is to compare the capacity of disinfection technologies such as chlorination, ozone, and electron beam, for removing antibiotic resistant bacteria (ARB) and ARGs. Based on this study, better ARG removal can be achieved by ozonation and electron beam. Relatively, high CT values of chlorination or ozonation are needed to remove ARB and ARG compared to conventional pathogens.

A Study on the Absorptive Removal of Magnesium ion and Calcium ion for Corrosion Prevent (부식방지를 위한 마그네슘 및 칼슘 이온의 흡착 제거에 관한 연구)

  • Hong Sung-Uk;An Hyung-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.40-44
    • /
    • 2004
  • To the removal of hardness materials, we've test the absorptive capacity of main material $Mg^{2+},\;Ca^{2+}$ on the using the activated carbon powder saturated in 0.1M Nitrilotriacetic acid by experimental methods. The absorptive properties of $Ca^{2+}\;and\;Mg^{2+}$ were measured with absorbent quantity and contact time., and investigated the physical properties of overall rate constant and adsorption constant adsorption isotherm, and Langmuir and Freundlich constant. In case of k' adsorption rate constants of $Ca^{2+},\;Mg^{2+}$, was 0.00299, 0.00529 by Bhattahary and Venkobachar equation. $k_{aa}$ was 0.00373, 0.00640 according with adsorption rate constants of Lagergren.