• 제목/요약/키워드: Remote Leakage Sensing

검색결과 16건 처리시간 0.024초

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

원격 상수도관망 누수감지 시스템에 관한 연구 (A Study on a Remote Leakage Sensing System in Waterworks Network)

  • 강병모;홍인식
    • 정보처리학회논문지D
    • /
    • 제11D권6호
    • /
    • pp.1311-1318
    • /
    • 2004
  • 인구증가와 발전으로 도시 집중화 현상에 따라 수도의 수요증가가 가속화되는 상태이다. 특히 물 부족현상 및 수질악화로 인한 수원확보도 어려워지고 있는 실정이다. 누수로 인한 막대한 손실을 줄이고자 컴퓨터와 인터넷을 이용하여 누수가 발생할 경우, 누수 여부를 판단하고 중앙 모니터링 센터에서 관리할 수 있는 시스템이 필요하다. 본 논문에서는 누수감지관과 TDR을 이용한 원격 상수도관망 누수 감지 시스템을 제안하였다. 유효성을 입증하기 위해 300mm 3-레이어 강관으로 파이로트 시스템을 구축하여 시뮬레이션 하였다.

원격탐사, 전기탐사, 전자기탐사 및 시추공영상의 융합적 분석을 통한 서산지역 방조제 누수구역 판별 (Investigation of Water Leakage in Seosan A-Region Sea Wall using Integrated Analysis of Remote Sensing, Electrical Resistivity Survey, Electromagnetic Survey, and Borehole Survey)

  • 홍성인;이동익;백광현;유영철;임국묵;유재형
    • 자원환경지질
    • /
    • 제46권2호
    • /
    • pp.105-121
    • /
    • 2013
  • 본 연구에서는 원격탐사, 전기비저항탐사, 전기전도도탐사(전자기탐사), 시추공 영상촬영법을 융합하여 효과적인 제방의 안정성 및 누수 평가 방법을 서산 A지구 방조제에 적용하여 제시하였다. Landsat ETM+열적외선 밴드를 사용하여 방조제 부근에서 다른 온도의 해수와 담수가 혼합되는 양상을 통해 누수의 존재, 규모 및 기간을 유추하였다. 전기비저항탐사를 방조제를 따라 실시하여 평균비저항 값 83.197 ${\Omega}$-m이하를 보이는 이상대의 수평적 수직적 분포를 확인하였다. 간조와 만조 시의 전기전도도 값의 분석을 통해 배경치의 영향을 최소화한 수평적 이상대 분포를 확인하였다. 시추공영상촬영을 통해 파쇄대의 수직적 분포양상과 기존 탐사법의 정확도를 확인하였다. 그 결과 전체 제방의 연장 중 41.7%에서 세 수평적 이상대 탐사법의 중첩구간이 확인되었으며, 시추공에서 확인된 수직적 파쇄양상을 고려할 때 누수구간이 제방단면의 중심부를 따라 상당부분 수평적으로 연장이 되어 방대한 양의 누수가 존재할 가능성이 높을 것으로 사료된다. 네 탐사법의 융합적 접근은 각 탐사방법이 가지고 있는 장점을 부각하고 단점을 보완하여 수평적 및 수직적인 누수구간과 기간의 확인 및 판별이 가능하고, 시추공에서 확인된 수직적 파쇄양상의 수평적 연장성을 예측하는데 높은 신뢰도를 보인다 할 수 있다.

Application of a NDI Method Using Magneto-Optical Film for Micro-Cracks

  • Jaekyoo Lim;Lee, Hyoungno;Lee, Jinyi;Tetsuo Shoji
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.591-598
    • /
    • 2002
  • Leakage magnetic flux is occurred in the cracked area of magnetized specimens, and also it changes the magnetic domain area of the magneto-optical film positioned on the specimen. It causes the change of the optical permeability of the magnetic domain on the crack area. So crack images can be obtained easily using this principle. On the other hand, utilizing a laser in this method makes possible to perform a remote sensing by detecting the light intensity contrast between cracked area and normal area. This paper shows the application of non-destructive inspection system taking advantage of magneto-optical method for micro-cracks and presents examples applied to the several types of specimens having fatigue cracks and fabricated cracks using this method. Also the authors prove the possibility of this method as a remote sensing system under the oscillation load considering application to real fields.

Estimated groundwater recharge including water pipes leakage in Kumagaya City

  • Saito, Keisuke;Ogawa, Susumu;Takamura, Hiroki;Yashiro, Yusuke
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.735-737
    • /
    • 2003
  • The drying up of seepage in Kumagaya City was caused by the increase of impermeable area with urbanization. The project of rain fall infiltration facilities has been planned for improvement of a hydrological cycle in Kumagaya City. With GIS and remote sensing, the most suitable arrangement for the rainfall infiltration inlets was examined. Distribution maps for infiltration, evapotranspiration and groundwater recharge at each town in Kumagaya City was designed from the land cover classification map with hydrological analysis. In these distribution maps, influence of the leak from drinking water and sewage networks was counted to the hydrological cycle.

  • PDF

저항성 누설전류 검출방식을 이용한 보안등 전기설비 원격점검 시스템 개발 (Development of Guard Lamp Remote Inspecion System Using Resistive Leakage Current Detecting)

  • 최명일;유재근;전정채;배석명
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.81-89
    • /
    • 2009
  • 본 논문에서는 일반용 전기설비 중에서 전기안전관리의 사각지대로 분류되는 보안등 전기설비를 대상으로 전기 안전요소들을 계측하고 원격 모니터링할 수 있는 보안등 원격점검시스템을 개발하였다. 단말기에서 계측하는 누설 전류는 위상차 측정법을 이용한 저항성분 누설전류($I_{gr}$) 측정 알고리즘을 이용하였으며, 계측데이터 전송을 위한 중 계기와 MMI에서 모니터링할 수 있는 시스템을 제작하였으며, 저항성 누설전류($I_{gr}$)검출 알고리즘의 타당성을 확인하기 위해 실험실 기반의 성능시험으로 저항성 누설전류($I_{gr}$)를 측정하였다.

보안등 전거설비의 Igr 누설전류 검출 및 원격감시장치 개발 (Development of Remote Supervision System for Guam Lamps by Way of Leakage Current(Igr) Detection Method)

  • 최명일;김영석;김종민;방선배
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.75-80
    • /
    • 2010
  • 본 논문에서는 일반용 전기설비 중에서 전기안전관리의 사각지대로 분류되는 보안등 전기설비를 대상으로 전기안전요소들을 계측하고 원격 모니터링 할 수 있는 보안등 원격점검시스템을 개발하였다. 단말기에서 센싱하는 누설전류는 위상차 측정법을 이용한 저항성분 누설전류(Igr) 측정 알고리즘을 이용하였으며, 계측데이터 전송을 위한 중계기와 MMI에서 모니터링 할 수 있는 시스템을 제작하였으며, Igr 누설전류 검출 알고리즘의 타당성을 확인하기 위해 실험실 기반의 성능시험으로 누설전류의 안정도를 확인하였다.

초분광 영상의 표적신호 분리에 의한 Matched Filter의 표적물질 탐지 성능 향상 연구 (Study on Improving Hyperspectral Target Detection by Target Signal Exclusion in Matched Filtering)

  • 김광은
    • 대한원격탐사학회지
    • /
    • 제31권5호
    • /
    • pp.433-440
    • /
    • 2015
  • 본 연구에서는 초분광영상을 이용한 표적탐지에 있어 배경 신호 특징에 포함되는 표적 신호가 탐지성능에 미치는 영향을 살펴보고, 분광각을 기준으로 표적과 유사한 분광반사 특성을 가지는 화소들을 배경 특징화 과정에서 제외함으로써 표적탐지 성능을 향상시킬 수 있는 방법을 제안하였다. 초분광 표적탐지를 위해 가장 흔히 이용되는 matched Filter와 adaptive cosine estimator 기법에 대해 실제 항공 초분광영상 자료와 여기에 인공표적을 삽입하여 생성한 모의 자료를 이용한 실험 결과, 배경 특징화를 위한 공분산행렬 계산 시 표적 스펙트럼과 유사도가 높은 표적 유사화소들을 제외함으로써 탐지 성능이 크게 향상될 수 있음이 확인되었다. 분광각외에 다양한 유사도 판정 기준들에 대한 적용성 연구와 함께, 제외되는 표적 유사화소들의 양이 최적으로 결정될 수 있는 방법에 대한 추가 연구가 이루어진다면 사용이 간편하고 성능이 우수한 초분광 표적탐지 기법으로 활용될 수 있을 것으로 기대된다.

화학사고 피해저감을 위한 GIS 연계 복합시뮬레이션 프로토타입 개발에 관한 연구 (A Study on the Development of GIS-based Complex Simulation Prototype for Reducing the Damage of Chemical Accidents)

  • 김은별;오주연;이태욱;오원규;김현주;임동연
    • 대한원격탐사학회지
    • /
    • 제36권5_4호
    • /
    • pp.1255-1266
    • /
    • 2020
  • 본 연구에서는 화학사고에 따른 인명피해 저감을 위해서 신속하고 정확한 화학물질 확산 범위 예측을 위한 복합시뮬레이션 프로토타입을 개발하였다. 복합시뮬레이션은 화학물질의 누출 특성을 고려하고자 근거리 확산과정에서 누출 운동량을 고려하였다. 원거리 확산과정에서는 사고지점 주변의 기상 및 지형정보를 이용하여 획일적으로 제시되었던 기존 모델의 바람 분포를 개선하여 실제와 유사한 바람장을 구현하였다. 개선된 근·원거리 확산과정에 따라 최종적으로 피해확산 범위는 기존의 모델에 비해서 정밀한 분포를 나타냈다. 본 연구에서 개발된 복합시뮬레이션의 시간대별 피해 범위 예측 결과 통해서 화학사고 발생 후 주민 대피 및 복귀 등 정책적 의사결정의 지원시스템으로서 활용도가 높을 것으로 기대된다.

GIS를 활용한 고속도로 염화수소 가스 누출 시나리오 기반 리스크 평가 (Risk Assessment Based on Highway Hydrogen Chloride Gas Leakage Scenario Using GIS)

  • 김구윤;이재준;윤홍식
    • 대한원격탐사학회지
    • /
    • 제37권3호
    • /
    • pp.591-601
    • /
    • 2021
  • 국내의 화학 산업이 지속적으로 발전이 이루어짐에 따라 화학물질의 취급량과 운송량은 매년 증가하고 있다. 우리나라 도로 화물운송은 90%이상을 차지하고 있으며, 화학물질 운송도 대부분 도로를 통해 이루어지고 있다. 이러한 화학물질 운송차량들은 사고가 발생하게 되면 대형사고로 이어질 수 있다. 운송차량은 1차 피해인 교통사고뿐만 아니라 2차 피해인 환경 피해 요인들인 수질오염, 토양오염 등을 발생시킬 가능성이 높다. 본 연구는 반포IC와 서초IC 구간을 연구지역으로 설정하여 염화수소 가스 누출에 대한 시나리오를 작성하여, ALOHA 프로그램을 사용하여 예측거리를 측정하고 거리에 따라 염화수소 가스가 도달한 시간을 분석하였다. 또한 GIS를 이용해 시간별로 발생한 피해 영역에 대해서 인구밀도를 이용한 리스크 평가를 수행하였다. 이를 통해 피해 영역에 대해서 예방·대응 방안의 필요성을 제시하였다.