• Title/Summary/Keyword: Remaining tooth

Search Result 177, Processing Time 0.024 seconds

A COMPARATIVE STUDY OF PRESERVING ABILITY OF HUMAN PERIODONTAL LIGAMENT CELLS STORED IN DIFFERENT STORAGE MEDIA (수종의 저장용액에서 치주인대세포의 생존율 비교)

  • Choi, Won-Kyung;Choi, Hyung-Jun;Choi, Byung-Jai;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.427-436
    • /
    • 1999
  • Preservation of the remaining periodontal ligament cells on an avulsed tooth is very important to the successful outcome of replantation. HBSS is recommended as the most suitable storage medium for the avulsed tooth that cannot be replanted immediately. But their availability near the site of an accident is doubtful. The purpose of this in vitro study was to compare periodontal ligament cells stored in different storage media obtained easily on the spot. Human periodontal ligament cells were collected from the premolar teeth extracted for orthodontic treatment. Cells were cultured in ${\alpha}-MEM$ culture medium containing 20% FBS, at $37^{\circ}C$ 100% humidity, in a 5% $CO_2$ incubator. Cells were cultured in 96 well culture plate, $5{\times}10^4$ cells per well with ${\alpha}-MEM$ and incubated for 24 hours. After discarding the medium, those cells were cultured in ${\alpha}-MEM$ contained with 10% FBS, pasteurized milk, sterilized saline, unstimulated saliva and bench-dried state at $25^{\circ}C$ room temperature for 30, 60, 90, 120, 180 minutes respectively. And then each group was measured using MTT assay. The results were as follows. 1. Between the group of each time, there was statistically significant difference. Periodontal ligament cells viability was highest in pasteurized milk and was reduced stepwisely in sterilized saline, unstimulated saliva and bench-dried state(p<0.05). 2. between the time of each group, there was statistically significant difference(p<0.05) but was no statistically significant difference at 90-120 minutes in pasteurized milk and at 60-90 minutes and 120-180 minutes in sterilized saline(p>0.05). In conclusion, HBSS as storage medium of an avulsed tooth is not practical on the spot. Insteadily pasteurized milk can be recommended to maintain the periodontal ligament cells viability.

  • PDF

A Comparative study of roughness of enamel surface to various interdental enamel stripping methods in vitro (치간 법랑질 삭제방법에 따른 치아표면 거칠기에 관한 비교연구)

  • Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.483-490
    • /
    • 1999
  • Interdental enamel stripping is an usual method for correction of abnormal tooth shape and tooth size discrepancy which is one of the etiologic factors of malocclusion. Clinically it Is useful to correct the minor crowding in anterior teeth and posterior occlusion during finishing stage of orthodontic treatment. But this procedure has risks such as irreversible tooth reduction and remaining roughness of enamel surface can accumulate plaque which can evoke periodontal problem. Even if various methods were introduced to minimize the enamel surface roughness, their evaluation was limited in morphologic differences by scanning electronic microscope(SEM). The purpose of this study was to compare the various interdental enamel stripping method by SEM and to quantify the difference of surface roughness by use of Surfcorder SEF-30D(Kosaka Lab. Ltd.) which can measure the roughness of surface. The stripping methods were divided into mechanical and mechanical-chemical method. Air-rotor stripping and separating strip were used for mechanical stripping and $37\%$ phosphoric acid was used for chemical stripping. The enamel surface roughness after mechanical or mechanical-chemical stripping of interproximal surfaces of premolars which were extracted for orthodontic purpose were measured and compared by means of SEM and $Surfcorder^{\circledR}$, the results were as follows. 1. Enamel surface of primary treated by coarse diamond bur and separating strip groups showed highest value of roughness. 2. To compare the primary treated groups between mechanical and mechanical-chemical method, the latter group showed lower value of roughness remarkably. 3. Mechanical stripping groups which were treated both coarse and fine instrument showed lower value of roughness as much as non treated group. 4. The use of Pumice for final polishing did not show significantly smoothening the stripped enamel surface any more.

  • PDF

Shear bond strength of brackets bonded with different self etching primers (Self etching primer를 사용하여 부착된 교정용 브라켓의 전단결합강도의 비교)

  • Yang, Jin-Young;Kim, Min-Ji;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • The purpose of this study was to evaluate the clinical usefulness of 4 self etching primers by measuring the shear bond strength of orthodontic brackets and examining the failure pattern of bracket-tooth interfaces. Methods: Seventy-five, defect-free, premolars were randomly assigned into five groups: control group (37% phosphoric acid + Transbond XT primer) and self etching primer treated groups (Transbond Plus self etching primer, Unifil bond, Clearfil SE bond, and Adhese). The shear bond strength was measured with a universal testing machine and the amount of residual adhesive remaining on the brackets after debonding was assessed by the adhesive remnant index (ARI). Results: The results showed that the groups conditioned with self etching primer had significantly lower shear bond strength than the control group (p < 0.05), although clinically acceptable. However, there were no significant differences in shear bond strength among the self etching primer groups (p > 0.05). Evaluation of the ARI scores indicated there was less resin remnant on the teeth in the groups conditioned with self etching primers, although not statistically significant. Conclusion: The results of this study suggest that all four of the self etching primers have shown acceptable bond strength for clinical use.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

A Retrospective study of the type of patients, the distribution of implant and the survival rate of $Xive^{(R)}$ implant (($Xive^{(R)}$)임플란트 식립시 환자 유형 및 식립부 분포와 생존율에 대한 후향적 연구)

  • Myung, Woo-Chun;Lee, Jung-Seok;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.523-534
    • /
    • 2007
  • This study is an analysis of types of patients and distribution of implant site and survival rate of $Xive^{(R)}$ implant. The following results on patient type, implant distribution and survival rate were compiled from 324 implant cases of 140 patients treated at the periodontal dept. of Yonsei University Hospital and G dental clinic between February 2003 and April 2006. 1. There are no dissimilarities between men and women, with patients in their 30, 40, 50s accounting for 80% of patients and accounted for 82% of implant treatments; the largest share of patients and implant treatments. 2. Mn, posterior area. accounted for 57% of implant treatments followed by Mx. posterior area(29%), Mx, anterior area(8%) and Mn, anterior area(6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 96% and fully edentulous patient accounted for the remaining 4%. 4. The major cause of tooth loss is periodontal disease, followed by dental canes, trauma and congenital missing. 5, The distribution of bone quality for maxillae was 54,2% for type III, followed by 30.8% for type II, 15% for type IV and 0% for type I. As for mandible, the distribution was 63% for type II, followed by 34% for type III, 2,5% for type I and 0,5% for type IV. 6. The distribution of bone quantity for maxillae was 55% for type C, followed by 35% for type B, 8% for type D and 2% for type A. As for mandible, the distribution was 60% for type B, followed by 32% for type C, 7% for type A and 0% for type D. 7. The majority of implants were those of 9.5-13 mm in length(95%) and regular diameter in width(82%). 8. The total survival rate was 98%. The survival rate was 97% in the maxillae region and 99% in the mandible region. 9. The survival rate in type I was 83%, in type II was 99%, in type III was 97% and in type IV was 100%. As for the bone quantity, the survival rate in type A and D(100%) was most, followed by type B(99%) and type C(96%). The results showed that $Xive^{(R)}$ implant could be used satisfactorily compare for the other implant system. But we most to approach carefully in certain extreme condition especially with poor bone quality and quantity.

COMPARATIVE STUDY OF REMOVAL EFFECT ON ARTIFICIAL PLAQUE FROM RBM TREATED IMPLANT (RBM 처리된 임플란트 표면의 인공치태 제거 효과 연구)

  • Park, Jae-Wan;Kook, Min-Suk;Park, Hong-Ju;Shet, Uttom Kumar;Choi, Choong-Ho;Hong, Suk-Jin;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.4
    • /
    • pp.309-320
    • /
    • 2007
  • Purpose: This study was to evaluate the removal effect on artificial plaque from RBM treated implant surfaces that are exposed due to peri-implantitis. Materials and methods: Artificial plaque with Streptococcus mutans and acquired pellicle adhered to RBM treated implant discs. Study materials divided into one control and six test groups. In test groups, physical and chemical methods used to remove plaques. Prophyflex, Professional Mechanical Tooth Cleaning (PMTC) and interdental brush as mechanical treatments and 0.1% Chlorhexidine, Citric acid, HCl tetracycline as a chemical treatment were used. To analyses the study, disc weight was measured for remaining plaque quantities and SEM(Scanning Electronic Microscope) findings was taken for evaluation of surfaces. Results: 1. In weight changes, there was significant difference between each treatment group and the control group (p<0.05). Therefore all treatment methods using this study have good ability for remove plaques. 2. In weight changes, there was no significant difference between mechanical and chemical group, and there were no significant differences between each groups (p>0.05). 3. SEM findings after mechanical treatment disclosed as follows; Prophyflex group looked like sound implant surface, and there were some paste on implant surface at PMTC group, and there were some artificial plaque at interdental brush group. 4. SEM findings after chemical treatment disclosed as follows; there were some dark lesions which were supposed as the product from Streptococcus mutans at Chlorhexidine, Citric acid and HCl tetracycline groups. Conclusion: All six methods using in this study have good ability to remove artificial plaque on RBM treated implant. According to SEM findings, prophyflex is a superior method for removing of dental plaque among test groups.

EFFECTS OF VARIOUS ETCHING TIMES ON DEPTH OF ETCH AND SHEAR BOND STRENGTH OF AN ORTHODONTIC RESIN TO BOVINE ENAMEL (부식시간이 소의 법랑질 부식깊이와 교정용 레진의 전단결합강도에 미치는 영향)

  • Kim, Jeong-Hoon;Lee, Ki-Soo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.23 no.1 s.40
    • /
    • pp.75-88
    • /
    • 1993
  • Recent reports indicate that shorter etching times than 60 seconds can be adopted without affecting the bond strength and clinical disadvantages. The purpose of this in vitro study was to compare the shear bone strength and to measure depth of etch at different etching time length. One hundred and eight extracted bovine lower central incisors were embedded each in a tooth cup with cold-cure acrylic resin. The facial surfaces of the teeth were ground wet with 600-, 800-, 1000-, and 1200-grit Sic papers, and finally polished with a water slurry of extrafine silicon carbide powder, washed with tap water, and dried with hot air. Nine groups of nine prepared teeth were etched with a commercial($38\%$ phosphoric acid solution) for 0, 5, 10, 15, 20, 30, 60, 90, and 120 seconds, respectively, rinsed with tap water, and dried with hot air. One conditioned teeth from every group was selected randomly for the scanning electron microscopic examination, and the remaining eight teeth of the groups were used for measuring the push shear bond strength after bonding brackets and immensing them in the $36.5^{\circ}C$ water for 24 hours. Another nine groups of three teeth were used for measuring the depth of etch and surface roughness with a surface profilometer. after pieces of adhesive tape of 3mm inner diameter positioned on the ground enamel surfaces, and etched with the above mentioned. The data obtained form the above expeiments were analysed statistically with one way ANOVA and Dunkan's multiple range test with the $95\%$ confidence level. The results and conclusion of the study were as follows; 1. The results of shear bond strength for the given experimental etching times were not statistically different, but showed the tendency of decreasing shear bone strength after over 60 seconds etching times. 2. On the scanning election microscopic examination, it was observed that the morphological patterns of etched enamel surface for 5 to 20 seconds were similar and consitent, and those for 30 to 120 seconds showed increasing over-etched patterns depending on the length of etching times. 3. The depth of etch was increased almost proportionally by the length of etching times, but it was not associated with the shear bond strength. 4. The surface roughness increased depending on the length of etching times, but it was not associated with the shear bond strength. 5. This experiment indicated that proper etching time with $38\%$ phosphoric acid solution is in the range of 5 to 30 seconds.

  • PDF

A COMPARATIVE ANALYSIS OF CLASS II DIVISION 1 TREATMENTS : ADOLESCENTS CONTRASTED WITH ADULTS (성장기 아동과 성인에서의 II급 1류 부정교합치료양상에 관한 두부방사선 계측학적 비교연구)

  • Kang, Bo-Seon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.247-261
    • /
    • 1995
  • The purpose of this study was to quantitate differences in the nature of the correction of Angle's Class II div 1 malocclusion dependent on the patient's age at the time of treatment. The sample consisted of 27 female patients in the adolescent group with a mean initial records age of 11.8 years and 25 female patients in the adult group with a mean starting age of 21.1 yrs. Lateral cephalometric head films were taken before and after orthodontic treatment with four bicuspid extraction. The results were obtained as follows. 1. None of maxillary skeletal parameters exhibited a significantly different in treatment change between adolescents and adults. But, in mandibular skeletal measurements, there were significant differences between two groups. (P<0.05) 2. Measures of vertical dimension in the adults remained unchanged during treatment, reflecting the effective absence of growth. 3. The steepness of occlusal plane in the adults changed significantly.(P<0.05) In contrast, the adolescents displayed stability of the occlusal plane. 4. According to the Johnston analysis, there was a significant difference in the total molar correction between two groups.(P<0.05) 5. According to the Johnston analysis, differential mandibular growth in the adolescents contrubuted $63\%$ of the total molar correction, with orthodontic tooth movement accounting for the remaining $37\%$. In the adults, dental movement comprised $99\%$ of the correction.

  • PDF

Guided Tissue Regeneration Using Barrier Membrane and Osseous Grafts in Surgically Created Furcation Defects in Dogs (성견의 외과적 치근이개부 골결손에 차폐막과 골이식재를 이용한 조직유도재생술시 치유양상)

  • Chung, Eun-Hee;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.967-987
    • /
    • 1996
  • The present study was to evaluate the healing patterns of guided tissue regeneration( GTR) using resorbable $Vicryl^{(R)}$(polyglactin 910) mesh and nonresorbable expanded polytetrafluoroethylene(ePTFE) membrane with or without bone grafting using autogeneous bone and demineralized freeze-dried bone allograft(DFDBA) in the grade II furcation defects. Mucoperiosteal flaps were reflected buccally in the mandibular 2nd, 3rd and 4th premolar areas and furcation defects were created surgically by removing $5{\times}6mm$ alveolar bone in 4 dogs. Root surfaces were thoroughly debrided of periodontal ligament and cementum, and notches were placed on root surface at the most apical bone level. In the right and left mandibular quadrant, each tooth was received $Vicryl^{(R)}$ mesh(ACE Surgical Supply Co., USA) only, $Vicryl^{(R)}$ mesh with DFDBA, $Vicryl^{(R)}$ mesh with autogeneous bone grafts, ePTFE membrane($Core-tex^{(R)}$ membrane, W.L. Gore & Associates Inc., USA) only, ePTFE membrane with DFDBA or ePTFE membrane with autogeneous bone grafts. For the fluorescent microscopic examination, fluorescent agents were injected at 2, 4 and 8 weeks after surgery. Four weeks after surgery, 2 dogs were sacrificed and ePTFE membranes were removed from remaining 2 dogs, which were sacrificed at 12 weeks after surgery. Undecalcified tissues were embedded in methylmethacrylate and $10{\mu}m$ thick sections were cut in a buccolingual direction. These sections were stained with hematoxylin-eosin stain and Masson's trichrome stain, and evaluated by descriptive histology and linear measurements. The results were as follows : 1) $Vicryl^{(R)}$ mesh group showed less connective tissue attachment than ePTFE membrane group. 2) The combination of GTR using $Vicryl^{(R)}$ mesh and osseous grafts resulted in new attachment and new bone formation more than GTR using $Vicryl^{(R)}$ mesh only. 3) GTR using ePTFE membrane, with or without osseous grafts, enhanced periodontal regeneration. 4) Root resorption and dentoalveolar ankylosis were observed in the areas treated with the combination of GTR and DFDBA. It was suggested that the effect of adjunctive bone grafting in GTR procedure depends on the materials and the physical properties of barrier membranes. $Vicryl^{(R)}$ mesh performed a barrier function and the use of adjunctive bone grafting may enhance the periodontal regeneration.

  • PDF

Re-establishment of occlusal plane in a patient with a failed implant prosthesis (실패한 임플란트 보철수복물을 가진 환자의 교합평면 재설정)

  • Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.141-153
    • /
    • 2018
  • A non-physiological occlusal plane caused by continuous tooth loss, occlusal wear, and failure of a prosthesis may result in an unattractive appearance and functional problems, such as reduced masticatory efficiency and occlusal interference. Therefore, when undertaking prosthetic treatment for edentulous patients or patients with a collapsed occlusal plane, it is important to establish an occlusal plane that is compatible with masticatory function. The patient in this case report had undergone restoration of a completely edentulous maxilla using an implant-supported fixed prosthesis. On follow-up examination in the following 6 years, mechanical complications were observed in the existing implant prosthesis, including porcelain chipping, occlusal wear, and screw loosening. Moreover, due to occlusal wear and supraeruption of the opposing anterior teeth, as well as loss of some posterior teeth, the occlusal plane had collapsed. Following diagnosis, the patient underwent full mouth rehabilitation, involving additional implant installation in edentulous sites, recreation of the existing prosthesis, and prosthetic restoration of all remaining teeth.