• Title/Summary/Keyword: Reliability standard

Search Result 1,714, Processing Time 0.033 seconds

Standardization to ensure Interoperability and Reliability of Campus Microgrid (캠퍼스 마이크로그리드의 상호운용성 및 신뢰성 확보를 위한 표준화)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.277-282
    • /
    • 2020
  • The construction of medium-and large-sized microgrid systems by unit area, which is being promoted worldwide, is being developed and expanded in the form of efficient operation of electric grids and independent operation in preparation for power emergencies. Therefore, for the development of the domestic electricity industry, it is urgent to analyze the current status and technology of relevant international standardization, and to make international standardization of domestic standard (draft) on the matters that need to be enacted and newly established. Campus microgrid implements smart grid element technologies such as Integrated Energy Management System(EMS), Distributed Power(DG), Energy Storage System(ESS), Demand Response(DR), and Electric Vehicle(EV) in a university campus. As a system that reduces energy use and improves energy use efficiency and energy independence, standardization is established to secure interoperability and reliability of such systems.

Reliability and Validity of an Iranian Version of the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire for Patients with Multiple Myeloma: the EORTC QLQ-MY20

  • Ahmadzadeh, Ahmad;Yekaninejad, Mir Saeed;Saffari, Mohsen;Pakpour, Amir H;Aaronson, Neil K
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.255-259
    • /
    • 2016
  • Background: Reliable and validated instruments are needed in order to study the quality of life in myeloma patients. This study aimed to translate and explore the psychometric properties of the European Organisation for Research and Treatment of Cancer (EORTC) myeloma module (QLQ-MY20) in Iranian patients. Materials and Methods: Two hundred and fifteen patients with multiple myeloma (MM) were recruited from Imam Khomeini Hospital, Tehran. A standard forward-backward translation procedure was implemented. Participating patients were asked to complete the EORTC QLQ-C30 and the QLQ-MY20 three times, at study entry, after two weeks, and again after three months. Data were tested for the range of measurement, internal consistency, test-retest reliability, known group comparison, responsiveness and factor structure. Results: Mean age of the patients was 60.7 years. No floor and ceiling effects were seen for the QLQ-MY20. Cronbach's ${\alpha}$ was greater than 0.80 for all three multi-item scales (ranging from 0.82 to 0.93). All four scales had test-retest reliability of 0.85 or greater. Results of the confirmatory factor analysis that the hypothesized 3-scale measurement model of the QLQ-MY20. Moreover, the Persian version for the QLQ-MY20 differentiated between subgroups of the patients in terms of beta-2 microglobulin, fracture and performance status. The responsiveness of the QLQ-MY20 to change over time was confirmed within 3 months. Conclusions: the results of our study indicate that our Iranian version of the QLQ-MY20 is a feasible, reliable and valid questionnaire for assessing the condition-specific quality of life of patients with MM.

Health-related Quality of Life in Women with Breast Cancer: a Literature-based Review of Psychometric Properties of Breast Cancer-specific Measures

  • Niu, Hui-Yan;Niu, Chun-Ying;Wang, Jia-He;Zhang, Yi;He, Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3533-3536
    • /
    • 2014
  • Background: Breast cancer is one of the most common cancers in women in the world. Health-related quality of life (HRQL) at treatment endpoint in cancer clinical trials is widely considered to be increasingly important. The aim of this review was to provide a literature-based assessment of the validity, reliability and responsiveness of breast cancer-specific HRQL instruments in women breast cancer patients. Materials and Methods: The databases consulted were Medline, PubMed, and Embase. The inclusion criteria required studies to: (1) involve use of HRQL measures; (2) cover women with breast cancer under standard treatment (surgery, radiation therapy, chemotherapy, hormone therapy, and targeted therapy); (3) involve the validity, reliability, or responsiveness of HRQL; (4) deal with validation of breast cancer-specific HRQL instruments. Results: A total of 16 studies were identified through the literature search that met the 4 inclusion criteria. Some seven instruments were assessed among these 16 studies: EORTC QLQ-BR23, FACT-B, FACT-ES, HFRDIS, LSQ-32, QLICP-BR, and SLDS-BC. EORTC QLQ-BR23, FACT-B, LSQ-32, QLICP-BR, and SLDS-BC are more general breast cancer-specific HRQL instruments. FACT-EB is the endocrine subscale combined with FACT-B in order to measure the side effects and putative benefits of hormonal treatment administered in breast cancer patients. HFRDIS is the HRQL measure focusing on hot flash concerns. Conclusions: This paper provides an overall understanding on the currently available breast cancer-specific HRQL instruments in women breast cancer patients.

Development of measurement scale for Korean scaling fear-1.1 (한국형 스케일링두려움 측정도구 개발(KSF-1.1))

  • Cho, Myung-Sook;Yi, Seung-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.4
    • /
    • pp.675-684
    • /
    • 2012
  • Objectives : The purpose of this study was to develop an instrument for Korean Scaling Fear (KSF)-1.1 in scaling patients. Methods : 402 sample size for scaling patients was studied in Daegu city in July and August of 2011. Mean and standard deviation was calculated in 3 dimensions(FWS: fear while scaling, DDH: distrust on dental hygienist, FAS: fear after scaling). Results : Age of 402 subjects was 36.5 years. In analyzing reliability for item-level, a range of correlation coefficient(${\alpha}$) on item-internal consistency(FWS, DDH, and FAS) was 0.58~0.88(${\alpha}$=0.90), 0.40~0.71(${\alpha}$=0.82), and 0.54~0.63(${\alpha}$=0.82), respectively. Floor(%) and ceiling(%) value on 3 dimensions were also 9.2% and 4.0%, 12.4% and 0.5%, and 17.7% and 1.2%, respectively, therefore, we found statistically high reliability for those(p<0.001). With explanatory factor analysis, this study could generate 3 dimensions(factor 1, eigenvalue 5.41, proportion 0.49; factor 2, eigenvalue 1.50, proportion 0.14; factor 3, eigenvalue 1.04, proportion 0.09) and 11 sub-scales. Also confirmatory factor analysis results showed that the KSF1.1 model was fitted very well in analysis of model fit($x^2$=112.94, df=41, p=0.000; goodness of fit index=0.95; adjusted goodness of fit index=0.92; root mean square residual=0.057). Conclusions : In conclusion, The findings of this study showed that developed reliable and valid instrument for measuring the KSF1.1 in the scaling patients.

A Quantitative Method for Quality Improvement of Information System Audit Evaluation (정보시스템 감리평가 품질 향상을 위한 정량화 방법)

  • Lee, Ki-Young;Kim, Young-Ho;Han, Ki-Joon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.173-184
    • /
    • 2012
  • As a result of the compulsory of information system audit and a rise in audit demand, the quality improvement of information system audit is being emphasized. However, since the current information system audit heavily depends on the auditor's experience, skill, and subjective judgments, it incurs distrust in the objectivity and reliability of audit results from audit interest person. Furthermore, so far research activities aimed at securing the objectivity and reliability of audits have not been adequately carried out. Therefore, this paper presents a quantitative method for information system audit evaluation in order to contribute to the quality improvement of overall information system audit through securing compliance, objectivity, and reliability of information system audit. The quantitative method is largely composed of two sectors, such as evaluation areas and items, scores calculation for evaluation items, and can generally apply the information system audit standard to information system audit evaluation.

Development and Validation of a Practical Instrument for Injury Prevention: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT)

  • Sun, Yi;Arning, Martin;Bochmann, Frank;Borger, Jutta;Heitmann, Thomas
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.140-143
    • /
    • 2018
  • Background: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT) is a practical instrument that is currently used in the German woodworking and metalworking industries to monitor safety conditions at workplaces. The 12-item scoring system has three subscales rating technical, organizational, and personnel-related conditions in a company. Each item has a rating value ranging from 1 to 9, with higher values indicating higher standard of safety conditions. Methods: The reliability of this instrument was evaluated in a cross-sectional survey among 128 companies and its validity among 30,514 companies. The inter-rater reliability of the instrument was examined independently and simultaneously by two well-trained safety engineers. Agreement between the double ratings was quantified by the intraclass correlation coefficient and absolute agreement of the rating values. The content validity of the OSH-MAT was evaluated by quantifying the association between OSH-MAT values and 5-year average injury rates by Poisson regression analysis adjusted for the size of the companies and industrial sectors. The construct validity of OSH-MAT was examined by principle component factor analysis. Results: Our analysis indicated good to very good inter-rater reliability (intraclass correlation coefficient = 0.64-0.74) of OSH-MAT values with an absolute agreement of between 72% and 81%. Factor analysis identified three component subscales that met exactly the structure theory of this instrument. The Poisson regression analysis demonstrated a statistically significant exposure-response relationship between OSH-MAT values and the 5-year average injury rates. Conclusion: These analyses indicate that OSH-MAT is a valid and reliable instrument that can be used effectively to monitor safety conditions at workplaces.

Proposal and Evaluation of Metrics for Measurement of Documents Reliability (개발산출물의 신뢰성 측정을 위한 메트릭의 제안과 평가)

  • Nam, Ki-Hyun;Han, Pan-Am;Yang, Hae-Sool
    • The KIPS Transactions:PartD
    • /
    • v.8D no.3
    • /
    • pp.247-256
    • /
    • 2001
  • Software is developing toward having more large scale and many functions day by day. Also, user’s requirements level for software is being high, especially, requirements for software quality is being high continuously. Methods which can satisfy such User’s requirements is being studied in various viewpoint. First of all, study about quality evaluation system and methodology is energetically in progress in viewpoint to improve quality of software by feed-back software quality evaluation result to developers. In this paper, we define metrics according to a system and developed quality measurement tables according to internal characteristics system of quality characteristics, subcharacteritics, internal characteristics for reliability between quality characteristics of international standard, ISO/IEC 9126 about software quality. And we propose evaluation results about development products using internal characteristics.

  • PDF

Survey & Analysis for the Calculation on the Industrial Customer Interruption Costs (산업용 수용가의 정전비용 산출을 위한 조사 분석(I))

  • Nam, K.Y.;Choi, S.B.;Ryoo, H.S.;Jeong, S.H.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.122-124
    • /
    • 2003
  • In recent, the various electric & electronic machines are newly developed everyday and the electricity supply system & environment on the process from generation to consumption of electricity also is being changed. In other words, both supplier and consumer of electricity are required to be responsible for their interruption costs. So, it is very important and meaningful work for evaluating the interruption costs in quantitative. Additionally, since the restructuring of electric industry is on going in world wide, after restructuring, most of all electric utilities and consumer have to consider the supply reliability and quality as a important element of the calculating the related costs and contract because it takes costs to keep the supply reliability and quality highly. Especially, the interruption or the supply reliability will have influence on the bilateral contract between supplier and customer as a key point to determine the once in competitive electric market. Therefore, it has very important moaning to calculate the interruption costs in the present that it is prepared to open the competitive electric market. In this paper, international standards, i.e. IEC, IEEE, are applied to the analysis on the interruption costs used in the questionnaires which are newly designed including short duration interruption by the authors instead of traditional interruption criteria. Firstly, using the questionnaires, the authors got related data from industries according to the standard industry classification which are being used in electric utility and other national statistics in Korea. However, analysis results are hard to say typical value because of the not so many samples. So, the authors are going to survey and focus on not all kinds of industry but a few kinds of them that their facilities are effected or stop by short duration interruptions, so there are large economical damages. Finally, the authors hope to find the reliable and meaningful model in interruption costs of industrial customer.

  • PDF

A Study on Types of Behavior and Satisfaction Level on the Information on Internet Fashion Web Sites (패션웹사이트 이용실태와 정보만족도에 관한 연구)

  • 신수연;김희수
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.8
    • /
    • pp.1500-1511
    • /
    • 2001
  • The purpose of this study were (1) to analyze the current fashion web-sites on the internet, which were increasing rapidly in number, (2) to find out the users purchase experiences of fashion products at internet shopping malls and satisfaction level on the information provided by the fashion sites. The questionnaire was administered to 332 women & men and data were analyzed by frequency, mean, standard deviation, factor analysis, reliability analysis, ANOVA and t-test. The results of this study were as follows. The factors on the satisfaction of information fashion web-sites categorized as 5 areas: Economy$.$Convenience, Aesthetics $.$Recreation, Variety $.$Interests, Up-to dateness $.$Specialization, and Reliability$.$ Precision. On the factor of Economy$.$Convenience, the users who had more frequent access and who were in their 20’s expressed the higher level satisfaction. On the factor of Aesthetics$.$Recreation, the users who had longer periods of time of use, who had lower level of internet shopping mall involvement, and students appeared to be more satisfied. On the factor of Variety$.$Interests, the users marking higher level of satisfaction were those who had higher frequency of uses, who had shorter period of time of use, who had lower level of internet shopping mall involvement and were students. On the factor of Up-to-dateness$.$Specialization, higher level of satisfaction was shown among the users who had shorter period of time of use, who had higher frequency of uses, who were in their 20’s and who were students. There was no significant differences according to Reliability & Precision factor.

  • PDF

Reliability and Validity of the Femorotibial Mechanical Axis Angle in Primary Total Knee Arthroplasty: Navigation versus Weight Bearing or Supine Whole Leg Radiographs

  • Kim, Seong Hwan;Park, Yong-Beom;Song, Min-Ku;Lim, Jung-Won;Lee, Han-Jun
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.326-333
    • /
    • 2018
  • Purpose: To evaluate the reliability and validity of the femorotibial mechanical axis angle from radiographs in the weight bearing (WB) and supine positions compared with navigation-measured values. Materials and Methods: Sixty-eight cases of navigation-assisted total knee arthroplasty (TKA) were included. The pre- and postoperative whole leg radiographs (WLRs) in WB and supine positions were compared with the initial and final navigation values. Results: The mean mechanical axis angle from the preoperative WBWLR and navigation were not statistically different (p=0.079) and were correlated strongly with each other (intraclass correlation [ICC], 0.818). However, on postoperative measurements, although the WBWLR and navigation values were not different (p=0.098), they were not correlated with each other (ICC, 0.093). The standard error of measurement was $1.8^{\circ}{\pm}3.6^{\circ}$ for the preoperative WBWLR and $2.5^{\circ}{\pm}4.8^{\circ}$ for the postoperative WBWLR. The validity that was determined by the Bland-Altman plot was not acceptable for both pre- and postoperative measurements. Conclusions: The preoperative WBWLR could provide accurate but not precise measurement value of the femorotibial mechanical axis angle for navigation-assisted TKA, and postoperative measurements in navigation were not comparable with radiographic measurements. The lack of agreement was found between the radiographic and navigation measurements of the coronal alignment regardless of pre- or postoperative evaluation although the accuracy was found acceptable. Level of Evidence : Level 4.