• Title/Summary/Keyword: Reliability standard

Search Result 1,714, Processing Time 0.032 seconds

Development of Control Software for KOREA Standard EMU (도시철도차량용 국내 표준모델의 주제어 S/W 개발(1))

  • 안태기;한성호;온정근;백종현;박현준
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.259-266
    • /
    • 1999
  • This paper is intended to provide a method to design control software for the TCMS, train control and monitoring system. The TCMS with this control software will be applied KOREA Standard EMU. The control software is designed by SCADE Case tool to concern safety and reliability. The function for the EMU is implemented in software easily programmed, using a functional block, graphic programming language. The control software has modular design and each module is tested with SCADE simulator. This time we focus a door control module, present a design method and a simulation method for that module.

  • PDF

Fault Current Calculation and Coordination by IEC Standards (IEC 표준에 의한 고장전류 계산과 보호협조)

  • Son, Seok-Geum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

Quality Testing Model of Mobile RFID Middleware (모바일 RFID 미들웨어 품질 평가 모델)

  • Jung, Hye-Jung
    • The Journal of Information Technology
    • /
    • v.10 no.4
    • /
    • pp.85-93
    • /
    • 2007
  • RFID applied in many area. I think that RFID enlarge for our life more and more. The application technology of RFID change the Mobile RFID using mobile phone and PDF etc. I think, Mobile RFID enlarge application technology gradually. In this paper, we propose the quality measurement metrics for mobile RFID middleware. I propose the quality testing model for interoperability and security of mobile RFID middleware. We examine the international standard for mobile RFID and software testing. In this paper, I proposed the evaluation model of mobile RFID middleware on the basis of international standard ISO/IEC 9126-2 and ISO/IEC 25000 series.

  • PDF

IN VIVO H-MRS QUANTIFICATION OF BRAIN METABOLITES USING WATER AS AN INTERNAL STANDARD

  • Lee, Jung-Woo;Choe, Bo-Young;Baik, Hyun-Man;Chung, Sung-Taek;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.79-79
    • /
    • 2002
  • Purpose: The reliability of absolute quantification of average metabolite concentrations in the human brain in vivo by H-MRS using the fully relaxed water signal as an internal standard was evaluated in a number of in vitro as well as in vivo measurements. Method: The experiments were performed on 3T MEDINUS MAGNUM MR-scanner using a STEAM sequence.

  • PDF

Development of Control Software for KOREA Standard EMU (도시철도차량용 국내 표준모델의 주제어 S/W 개발(3))

  • 안태기;한성호;이수길;이관섭;김원경;최규형
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.360-367
    • /
    • 2000
  • This paper is intended to provide a method to design control software for the TCMS, train control and monitoring system. The TCMS with this control software will be applied KOREA Standard EMU. The control software is designed by SCADE Case tool to concern safety and reliability. The function for the EMU is implemented in software easily programmed, using a functional block, graphic programming language. The control software has modular design and each module is tested with SCADE simulator. This time we focus a Driving control module, including brake control module, and present a design method and a simulation method for that module.

  • PDF

Development of a Sliding-Plug Entrance Door System for Urban Electric Transit Unit to Reduce Inside Noise Level (전동차 소음저감을 위한 슬라이딩플러그 출입문 개발)

  • 서승일;임영호;신동국
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.2
    • /
    • pp.112-117
    • /
    • 2002
  • Reduction of noise level in the cabin of urban transit unit is an important issue to enhance the comfortability of passengers. It is made clear that a cause of increased noise level in cabin is the imperfect airtightness of entrance doors. In this study, the sliding-plug door system is developed to reduce the noise level of cabins by securing the airtightness of entrance door. The sliding-plug door system is composed of air-driven engine, swing arms, guide rails, guide rollers and locking devices. It is economical owing to using the previous door engine system. It is also adequate for the platform system of our subway station. It was tested to prove the reliability of system and was applied to standard urban transit unit. The effectiveness of noise reduction in cabin resulting form the sliding-plug door system was confirmed by test results.

A Study on Structural Analysis of Butterfly Valve Components by Pressure Testing of the Industrial Standard (산업용 표준의 압력시험 방법에 의한 버터플라이 밸브 구성품의 구조해석에 관한 연구)

  • Shin, Myung-Seob;Yoon, Joon-Yong;Park, In-Won;Lee, Seoung-Hwan;Park, Han-Yung;Jung, Seung-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.5-9
    • /
    • 2011
  • Butterfly valves are widely used in current industry to control the fluid flow. They are used for both on-off and throttling applications involving large flows at relatively low pressure-drop especially in large size pipelines. In this study, we carried out the structure analysis of the butterfly valve components according to pressure testing of the industrial standard. the numerical simulation was performed by using ANSYS Workbench. The reliability of valve is evaluated under the investigation of the strain rate, the leak test and the durability of the valve.

Characteristics of Programming on Analog Memory Cell Fabricated in a 0.35$\mu{m}$Single Poly Standard CMOS Process (0.35$\mu{m}$ 싱글폴리 표준 CMOS 공정에서 제작된 아날로그 메모리 셀의 프로그래밍 특성)

  • 채용웅;정동진
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.425-432
    • /
    • 2004
  • In this paper, we introduce the analog memory fabricated in a 0.35${\mu}{\textrm}{m}$ single poly standard CMOS process. We measured the programming characteristics of the analog memory cell such as linearity, reliability etc. Finally, we found that the characteristics of the programming of the cell depend on the magnitude and the width of the programming pulse, and that the accuracy of the programming within 10mV is feasible under the optimal condition. In order to standardize the characteristics of the cell, we have investigated numbers of cells. Thus we have used a program named Labview and a data acquisition board to accumulate the data related to the programming characteristics automatically.

Noninvasive Hematocrit Monitoring Based on Parameter-optimization of a LED Finger Probe

  • Yoon, Gil-Won;Jeon, Kye-Jin
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.107-110
    • /
    • 2005
  • An optical method of measuring hematocrit noninvasively is presented. An LED Light with multiple wavelengths was irradiated on fingernail and transmitted light from the finger was measured to predict hematocrit. A finger probe contained an LED array and detector. Our previous experience showed that prediction accuracy was sensitive to reliability of the finger probe hardware and we optimized the finger probe parameters such as the internal color, detector area and the emission area of a light source based on Design of Experiment. Using the optimized finger probe, we developed a hematocrit monitoring system and tested with 549 persons. For the calibration model with 368 persons, a regression coefficient of 0.74 and a standard deviation of 3.67 and the mean percent error of $8\%$ were obtained. Hematocrits for 181 persons were predicted. We achieved a mean percent error of $8.2\%$ where the regression coefficient was 0.68 and the standard deviation was 3.69.

A Study on the Allowable Deviation for the Measured Level of the Impact Sound Insulation Performance (바닥충격음 차음성능평가에 있어서 측정 레벨의 허용오차에 관한 연구)

  • 장길수;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.222-226
    • /
    • 1997
  • The reproducibility of measured level is a prior condition for the reliable assessment of the sound insulation performance. To review the reproducibility of impact sound level, 20 floors were selected in highrise apartment house, and then impact sound levels of two kinds of typical floors were measured with 10 times in each receiving point. The impact sound insulation class values were derived with a standard tapping machine and bang machine. Inspection of the result showed that smaller scale of the room caused to lower the reproducibility and that the higher values of standard deviation in lower frequency caused to deteriorate the reliability of assesment. Thus to enhance the reproducibility of the impact sound insulation class, greater allowable deviation of measured level is required in lower frequency than in higher one.

  • PDF