• Title/Summary/Keyword: Reliability standard

Search Result 1,693, Processing Time 0.025 seconds

A Study on the Reliability Improvement for Assurance Pressure of Tank Gun Barrel (전차 포신의 보증압력 신뢰성 향상 연구)

  • Kim, Sung Hoon;Park, Young Min;Noh, Sang Wan;Jun, Sang Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.115-122
    • /
    • 2020
  • This study aimed to improve the reliability of the assurance pressure of a gun barrel due to the difference between the US Standard and Korean Standard. In addition, the reliability was found to differ according to the maximum pressure of the Ammunition, so restrictions are expected. During the development of the new bullet, the maximum pressure of the bullet was approximately 3,000 psi higher than the assurance pressure of the gun barrel. To solve this problem, the reliability of the cannon was analyzed when the assurance pressure of the gun barrel increased. First of all, the technical data from overseas were reviewed to check for cases of increased assurance pressure, and tests were performed to determine if it could withstand high pressure through a verification firing test. Finally, the simulation analyzed the stability of the recoil buffer. The study found no abnormal results in all items, suggesting that an increase in the assurance pressure for a gun barrel was possible. This study is expected to be used as basic data for future reliability studies of similar equipment.

The inter-rater absolute reliability and validity of the Figure-of-8 Walk test in patients with chronic stroke (만성 뇌졸중 환자 8자 모양 경로 보행 검사의 측정자간·절대적 신뢰도와 타당도)

  • Park, Chang-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.467-474
    • /
    • 2017
  • To investigate the intra-rater absolute reliabilities and validity of the Figure of-Eight Walk test (F8WT) in patients with chronic stroke. A total of 36 subjects with chronic stroke participated in this study. The inter-rater reliability of F8WT was calculated using intra-class correlation coefficients($ICC_{2,1}$). Moreover, we used the standard error measurement (SEM) and the small real difference (SRD) to examine the absolute reliability indices. The validity was demonstrated by a spearman correlation of F8WT with Postural Assessment Scale for Storke(PASS) and Trunk Impairment Scale(TIS). The inter-rater reliability of F8WT was excellent; ICC2,1=0.95(0.91~0.97), acceptable SEM=1.02, and SRD=2.82. F8WT were also found to be significantly associated with PASS(r=-0.82) and TIS(r=-0.85). Therefore, F8WT is a reliable measurement tool and is correlated well with stroke-impairments, such as postural and trunk control. F8WT will be a useful tool in evaluating the walking performance of subjects with chronic stroke.

Reliability Evaluation of the Estimation of Suspended Sediment Dispersion (부유사 확산예측 모형의 신뢰도 평가에 관한 연구)

  • Tac, Dae-Ho;Chung, Younjin;Jun, Eun-Ju;Yang, Joon-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.890-898
    • /
    • 2022
  • Dispersion of suspended sediment, caused by coastal and marine development, is a key item in assessing marine environmental impact as it adversely affects marine life by increasing the level of turbidity and decreasing the amount of sunlight in seawater. However, its estimation has not been reliable because of the absence of a standard for the data measurement and divergent approaches to the impact assessment. In this study, we examined the estimation models from 58 Marine Environmental Impact Statements (MEISs, 2012-2014) to identify the gaps in the assessment and devise ways of improving the estimation. We developed four index items-grid system; unit load, particle size, and settling velocit-to evaluate their reliability in the estimation. The mean reliability score of each index was overall low-25 for grid system, 60 for unit load, 34 for particle size, and 17 for settling velocity. To ensure high reliability, it is important to develop a standard guideline that defines precise measurement of suspended sediment for unit load and settling velocity by particle size, followed by a grid system with compatible size for modelling. This can improve the estimation and thus underlie coherent impact assessment of suspended sediment dispersion on marine environment.

IOT-based SMEs producing standardized information system model analysis and design (IOT기반 중소기업 생산정보화시스템 표준화 모델 분석 및 설계)

  • Yoon, Kyungbae;Chang, Younghyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.2 no.1
    • /
    • pp.87-91
    • /
    • 2016
  • This study is to develop a standard model in order to establish IOT production information system and to analyze the effect. Professional IT industry and SMEs that want to build a production information system can be applied to standard models to build the system more effectively. It provides ease of construction and reliability for IOT production information system with removing irrational elements, product quality and reducing production cost. In addition, it can be applied to standardize management of raw materials supply and demand aggregation processes of production and constructed a system more effectively using standard module.

An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film (EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.79-83
    • /
    • 2018
  • An accurate method to measure shielding effectiveness(SE) of EMI spray coating film is presented. After high frequency simulating, Circular coaxial standard test fixture is fabricated. A sample of EMI spray coating film was fabricated for insertion into a circular coaxial standard test fixture. The measuring instrument used an Agilent 8722ES vector network analyzer for the SE measurement. The exact SE of copper and silver mixed spray coating sample was measured by the composition of the measuring instrument and the measuring sample. The SE of copper sample was measured at 70 dB and the SE of copper and silver mixed spray coating sample was measured at 60 dB. As a result of the measurement, the reliability of the circular coaxial standard test fixture was confirmed.

An Open Standard-based Terrain Tile Production Chain for Geo-referenced Simulation

  • Yoo, Byoung-Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.497-506
    • /
    • 2008
  • The needs for digital models of real environment such as 3D terrain or cyber city model are increasing. Most of applications related with modeling and simulation require virtual environment constructed from geospatial information of real world in order to guarantee reliability and accuracy of the simulation. The most fundamental data for building virtual environment, terrain elevation and orthogonal imagery is acquired from optical sensor of satellite or airplane. Providing interoperable and reusable digital model is important to promote practical application of high-resolution satellite imagery. This paper presents the new research regarding representation of geospatial information, especially for 3D shape and appearance of virtual terrain. and describe framework for constructing real-time 3D model of large terrain based on high-resolution satellite imagery. It provides infrastructure of 3D simulation with geographical context. Web architecture, XML language and open protocols to build a standard based 3D terrain are presented. Details of standard-based approach for providing infrastructure of real-time 3D simulation using high-resolution satellite imagery are also presented. This work would facilitate interchange and interoperability across diverse systems and be usable by governments, industry scientists and general public.

Effect of Information Quality of Standard Menu on User's Satisfaction and Performance in ERP System of Contract Foodservice Management Company (위탁급식 전문업체의 ERP 시스템에서 표준메뉴 정보품질이 사용자 만족도 및 업무성과에 미치는 영향)

  • Kim, Hyeon-A;Yang, Il-Seon;Kim, Jang-Mi
    • Journal of the Korean Dietetic Association
    • /
    • v.11 no.2
    • /
    • pp.170-178
    • /
    • 2005
  • The purposes of this study were 1) to analyze the effect of the information quality of standard menu system of ERP on the user’s satisfaction 2) to analyze the effect of the information quality of standard menu system of ERP on the user’s performance. The questionnaires were distributed to 260 end users(dietitians, foodservice management managers) in charge of managing the institutional foodservice such as the office(government agencies, factories), schools(universities, middle and high school) and hospitals which were managed by contract foodservice management company “C” in Seoul and Kyunggi. The surveys were performed from July 26 to July 30, 2004. Two hundred and fifty questionnaires were responded(response rate : 96.2%). The statistical analysis was conducted by using SPSS Win(11.5). And the descriptive analysis, factor analysis, reliability test, pearson correlation and simple regression analysis were performed. The results showed that the information quality of standard menu system of ERP have a significant positive effect on the user’s satisfaction(p<0.001) and user’s performance(p<0.001). When constructing standard menu system on ERP in the contract foodservice management company, the information quality of standard menu system of ERP should be guaranteed in order to satisfy the end-user and to improve the user’s performance.

  • PDF

Development of a Femur Neck Bone Mineral Density Measuring Device for Accurate Examination

  • Han, Man-Seok;Seo, Sun-youl;Kim, Yong-Kyun;Jeon, Min-Cheol;Lee, Hyun-kuk;Yoo, Se-Jong
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.298-302
    • /
    • 2016
  • In bone density examinations, a change in the measured BMD occurs owing to the differences between the measured areas. To address this problem, we aimed to develop a new auxiliary device that could be rotated by $15^{\circ}$ by fixing the ankle to the distal femur neck. Dual energy X-ray absorptiometry (DXA) of BMD examinations were performed once a year, but 10 patients were examined over three sessions to analyze the area for measuring the femur neck BMD. The goal of this test was to determine the device's reliability, and the results were expressed in terms of the standard deviation of measurements. After performing bone density measurements using the new auxiliary device on 10 normal patients, with three measurements for each patient, the obtained standard deviation was 0.03. The standard deviation of the measured BMD was 0.19 when using the currently existing auxiliary device, while the standard deviation of the measured BMD was 0.03 when using the new auxiliary device. By using the new auxiliary device, the standard deviation could be reduced by ~80%. Accurate rotation of the femur neck was possible in all examinations, and the standard deviation of BMD measurements could be reduced by up to 80% compared with the measurements performed using the currently existing auxiliary device. We hope that this advantageous new design can be used as a standard auxiliary device for measuring the femur neck BMD.

Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner (CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가)

  • Kim, Sa-Hak;Kim, Jae-Hong;Kim, Chong-Kyen
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.673-678
    • /
    • 2015
  • The purpose of this study was to evaluate the reliability and accuracy of linear measurements in digital models compared to master model. A master model (ANKA-4; Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Four linear measurements were recorded between landmarks, directly on the master model and the digital models by a single examiner. Measurements were made with a digital caliper from manual model and with the software from the virtual models. The t-test for paired samples and intraclass correlation coefficient (ICC) were used for statistical analysis. The measurement of two methods showed good reliability. The mean differences between master and digital model were 0.06~0.12 mm. These in vitro studies show that accuracy and reliability of the digital impression is similar to that of the gold standard. Therefore digital impression was also considered to be a acceptable for placement clinically.

Capabilities of stochastic response surface method and response surface method in reliability analysis

  • Jiang, Shui-Hua;Li, Dian-Qing;Zhou, Chuang-Bing;Zhang, Li-Min
    • Structural Engineering and Mechanics
    • /
    • v.49 no.1
    • /
    • pp.111-128
    • /
    • 2014
  • The stochastic response surface method (SRSM) and the response surface method (RSM) are often used for structural reliability analysis, especially for reliability problems with implicit performance functions. This paper aims to compare these two methods in terms of fitting the performance function, accuracy and efficiency in estimating probability of failure as well as statistical moments of system output response. The computational procedures of two response surface methods are briefly introduced first. Then their capabilities are demonstrated and compared in detail through two examples. The results indicate that the probability of failure mainly reflects the accuracy of the response surface function (RSF) fitting the performance function in the vicinity of the design point, while the statistical moments of system output response reflect the accuracy of the RSF fitting the performance function in the entire space. In addition, the performance function can be well fitted by the SRSM with an optimal order polynomial chaos expansion both in the entire physical and in the independent standard normal spaces. However, it can be only well fitted by the RSM in the vicinity of the design point. For reliability problems involving random variables with approximate normal distributions, such as normal, lognormal, and Gumbel Max distributions, both the probability of failure and statistical moments of system output response can be accurately estimated by the SRSM, whereas the RSM can only produce the probability of failure with a reasonable accuracy.