• 제목/요약/키워드: Reliability standard

검색결과 1,685건 처리시간 0.03초

뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구 (Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke)

  • 박일우;임원빈;박규남;이충휘
    • 한국전문물리치료학회지
    • /
    • 제21권1호
    • /
    • pp.1-12
    • /
    • 2014
  • The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

지진하중을 받는 사장교의 확률유한요소해석 및 신뢰성해석 (The Stochastic Finite Element Analysis and Reliability Analysis of the Cable Stayed Bridge Subjected to Earthquake Load)

  • 신재철;한성호
    • 한국전산구조공학회논문집
    • /
    • 제18권1호
    • /
    • pp.29-42
    • /
    • 2005
  • 구조물에 포함되어 있는 불확실성에 의한 영향은 논리적으로 구조물의 안전도 해석에 활용할 수 있는 신뢰성 평가방법에 의해 안전성 검토를 수행하는 것이 합리적일 것이다. 따라서 본 연구에서는 지진하중을 받는 사장교 구조물을 대상으로 확률유한요소법을 기존의 신뢰성이론에 적합하도록 정식화하여 구조물의 동적응답해석 및 신뢰성해석을 보다 효율적으로 수행할 수 있는 프로그램을 작성하였다. 이를 바탕으로 하여 확률변수에 따른 변위, 부재력 및 케이블긴장력 등에 대한 평균, 표준편차 및 변동계수 등을 검토함으로써 동적응답특성을 정량적으로 분석하였다. 또한 신뢰성지수 및 파괴확률을 검토하여 사장교 구조물의 안전성을 평가하였다.

골관절염영향측정척도(AIMS-SF)의 타당도 및 신뢰도 - 일부 슬관절 골관절염 환자를 대상으로 - (Validity and Reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in Knee Osteoarthritis Patients)

  • 이승주;남태호
    • The Journal of Korean Physical Therapy
    • /
    • 제19권5호
    • /
    • pp.29-41
    • /
    • 2007
  • Purpose: The aim of this study was to examine the validity and reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in patients with knee osteoarthritis(OA). Methods: The sample consisted of 62 patients who had received physical therapy at the physical therapy units of the Andong Medical Center, Sungso Hospital, Ahn Orthopedic Surgery Clinic, and St. Luke Clinic in Andong city in June 2006. Questionnaire on the AIMS-SF was recruited by 5 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency(Cronbach's alpha coefficient: ${\alpha}$), item-discriminant validity, Pearson's relation coefficient. To explore construct validity we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. Results: 62 OA patients's an average $age{\pm}standard$ deviation was $53.8{\pm}14.4$ years (range: $40{\sim}81$ yr). The internal consistency reliability of 11 items, as estimated by Cronbach's ${\alpha}$ coefficient, was high ranging $0.60{\sim}0.78$ (except for 0.40 for mobility level and -0.48 for mood). The internal consistency reliability of item-each scale was also high $0.82{\sim}0.93$ (except for 0.48 for mood). Of 11 items, the item-discriminant validity on 6 items was high (${\alpha}$ coefficient range: $0.11{\sim}0.25$), however, others (0.57 for tension level, 0.48 for arthritis pain, 0.41 for walking and bending, and 0.40 for work) were a little low. The construct validity by factor analysis was a little low. Conclusion: In conclusion, the results reported here confirm the validity and reliability of the AIMS-SF in patients with OA of the knee. The Collection of information on health status using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.

  • PDF

아동용 교우관계문제검사의 개발과 타당화 (Development and Validation of Inventory of Peer Relation Problems for Elementary School Children)

  • 정혜원
    • 초등상담연구
    • /
    • 제7권1호
    • /
    • pp.37-66
    • /
    • 2008
  • This study has been carried out with the aims of developing a comprehensive inventory of peer relation problems, which is based on the Korean Inventory of Interpersonal Problems Circumplex scales (KIIP-C). It also aims to examine reliability and validity of the inventory, and provide a preliminary norms. For the current study, inventory items were culled from the following sources: the Korean Inventory of Interpersonal Problems Circumplex scales (KIIP-C), various current scales dealing with peer relations of children, and a survey of children's peer relation problems. The preliminary items for each scale were administered to 220 fourth through sixth graders. The resulting skewness of distribution, kurtosis, mean and standard deviation, item-total correlation, internal consistency, and meanings of the items were comprehensively considered in selecting the final 64 items. In order to check on reliability, internal consistency, convergence and discrimination reliability of the final items and scales, the data were collected from 1,046 fourth through sixth graders currently attending four elementary schools. The study results can be summarized as follows. Internal consistency of the inventory of peer relation problems showed the range between .70-.94 (median value of .75), split-half reliability between .67-.83 (median value of .75), and test-retest reliability between .69-.88 (median value of .81). Inter-correlation of 8 scale scores and factor analysis results of individual ipsative scores showed that the circumplex property of inventory of peer relation problems is appropriate. Regarding correlations between various existing indices and scales related to peer relation problems, both convergence reliability and discrimination reliability were found to be fair. When the scale scores for the inventory of peer relation problems compared according to the factors of gender and grade, the primary effects of gender and grade were statistically meaningful whereas effects of interaction between gender and grade were not. This study can be considered meaningful in that it constructed an inventory for a comprehensive evaluation of peer relation problems specific for children and provided preliminary norms.

  • PDF

스마트 의류의 사용환경 내구성 시험에 대한 국제 표준화 현황과 제품의 신뢰성 향상 및 품질 관리를 위한 향후 과제 (Current Status of International Standardization for Durability Test Methods in Smart Clothing and Future Challenges in Enhancing Product Reliability and Quality Control)

  • 김시연;임가영;김수경;이정현
    • 한국의류산업학회지
    • /
    • 제25권3호
    • /
    • pp.398-408
    • /
    • 2023
  • Smart clothing products can experience a decrease in performance and reliability due to various mechanical, biological, and chemical stress factors that occur throughout their life cycle. These issues can hinder consumer acceptance of the products. This study aims to enhance the reliability of smart clothing and facilitate quality control by analyzing and identifying the current status of international standardization for smart clothing and electronic textiles (e-textiles). The focus of this analysis was on the durability test methods in the use environment. Furthermore, similar standards published by different standardization organizations for durability tests were compared in depth. The study showed that a total of 27 international standards have been developed or are currently under development. The current standardization efforts mainly aim to develop functionality and durability test methods for smart clothing and e-textile products. A detailed comparison was made between two international standards (IEC 63023-204-1:2023 and AATCC TM210:2019) specifically in relation to the washing durability test method and the electrical resistance measurement standards (BS EN 16812:2016 vs AATCC EP13-2021), before and after the environmental exposure tests. Based on this comparison, several suggestions have been made and discussed for the future revision of these international standards.

신뢰성 개념을 이용한 포장의 평균수명 및 신뢰도 예측 (Estimation of Mean Life and Reliability of Highway Pavement Based on Reliability Theory)

  • 도명식
    • 대한토목학회논문집
    • /
    • 제30권5D호
    • /
    • pp.497-504
    • /
    • 2010
  • 본 연구에서는 최근 10년간의 수원과 의정부지역의 국도 포장구간의 수명 데이터를 기반으로 신뢰성 개념을 도입하여 포장 수명의 고장확률, 신뢰도, 평균 수명 등의 정보를 산정하는 방안을 제시하였다. 모수적 추론 방법인 최우추정법과 확률지를 이용하여 최적 수명분포형태가 대수정규분포임을 확인하였으며, 본 연구에서 제안한 대수정규수명분포에 의해 추정된 누적 고장확률이 실제 관측값과 차이가 거의 없음도 확인하였다. 나아가 추정된 모수를 기반으로 신설 포장과 덧씌우기 포장의 하중별 평균 수명을 산정한 결과, 각각 6.5년~7.9년과 7.3년~9.1년으로 추정되었으며 상대적으로 덧씌우기 구간의 평균수명이 더 길게 추정되었다. 본 연구에서 제안한 신뢰성 개념을 이용한 분석 방법은 포장관리 및 유지보수 데이터가 축적되어감에 따라 비교적 용이하게 계속 보완이 가능하며 보다 정확한 포장수명에 대한 신뢰도 값에 접근해 갈 수 있을 것으로 기대된다.

Electrodeposited Tin Properties & Their Effect on Component Finish Reliability

  • Fusco Phil;Schetty Rob
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2004년도 ISMP Pb-free solders and the PCB technologies related to Pb-free solders
    • /
    • pp.201-209
    • /
    • 2004
  • As the European Community's Directive on the Restriction of Hazardous Substances in Electrical and Electronic Equipment banning lead (Pb) in electronics products will take effect on July 1, 2006, most electronics manufacturers will be commencing with volume production of Pb-free components by the middle of 2004. Electrodeposited pure tin finishes on electronic components are a leading contender to replace the industry standard tin-lead. Commensurate with this shift will be a somewhat steep learning curve as manufacturers adapt a variety of equipment and processes to contend with the issues surrounding this critical, industry-wide material conversion. Since the electrodeposited finish directly influences the critical reliability characteristics of the component itself, the nature of the Pb-free component finish must be well characterized and understood. Only through a thorough examination of the attributes of the electroplated tin deposit can critical decisions be made regarding component finish reliability. This paper investigates the properties of electrodeposited tin that may have an effect on component reliability, namely, grain structure (size and shape), oxide formation, tin whisker formation, and solderability. Data will be presented from laboratory and production settings, with the objective being to enable manufacturers to draw their own conclusions regarding previously established perceptions and misconceptions about electrodeposited tin properties.

  • PDF

다수준 실험계획법을 이용한 비정규 분포의 신뢰도 계산 방법 (Reliability Analysis for Nonnormal Distributions Using Multi-Level DOE)

  • 최현석;이상훈;곽병만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.840-845
    • /
    • 2004
  • The reliability analysis for nonnormal distributions using the three level DOE(design of experiments) method was developed by Seo and Kwak in 2002. Although this method estimates only up to the first four moments(mean, standard deviation, skewness, and kurtosis) of the system response function, the result and the type of probability distribution determined by using the Pearson system are shown very good. However the accuracy is low in case of nonlinear performance function and sometimes, the level calculated is outside of the region in which the random variable is defined. In this article we suggest a modified three level DOE method to overcome these weaknesses and to obtain optimum choice for 3 levels and weights to handle nonnormal distributions. Furthermore we extend it to finding the optimum choice for 5 levels and weights to increase the accuracy in case of nonlinear performance function. A systematic procedure for reliability analysis is then proposed by using the Pearson system.

  • PDF

가정간호에 대한 돌봄만족도 측정도구 개발 - Watson의 돌봄개념을 중심으로 - (Development of the Tool for Measuring the Care Satisfaction of Home Health Nursing based on Watson's Theory of Human Caring)

  • 전연숙;강경아
    • 한국보건간호학회지
    • /
    • 제28권1호
    • /
    • pp.57-70
    • /
    • 2014
  • Purpose: This study is a methodological research study for development of a tool for measurement of care satisfaction of home health nursing in patients who have received care through home health nursing and to test the validity and reliability of the tool. Method: Based on Watson's theory of caring and its constituent factors, the literature related to home health nursing was reviewed, and the standard of home health nursing was compared and analyzed. For verification of the validation and reliability of the final tool which has been developed, data were collected from 166 people who were receiving home health nursing care. Result: According to results of analysis of the factors based on Kaiser and scree test, 10 factors with an eigenvalue greater than 1.0 were extracted, and they explained 72.26% of the total variance. In addition, the factor loadings of 56 questions were greater than .30. For verification of reliability, Cronbach's alpha for all 56 items was .98 and Guttman split half reliability coefficient was .90. Conclusion: This tool based on Watson's theory of caring contributed to development and application of the nursing theory through verification of the theory.

Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion

  • Yoon, Tae-Lim
    • The Journal of Korean Physical Therapy
    • /
    • 제29권3호
    • /
    • pp.145-151
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the validity and reliability of the measurement of shoulder joint motions using an inertial measurement unit (IMU). Methods: For this study, 33 participants (32 females and 1 male) were recruited. The subjects were passively positioned with the shoulder placed at specific angles using a goniometer (shoulder flexion $0^{\circ}-170^{\circ}$, abduction $0^{\circ}-170^{\circ}$, external rotation $0^{\circ}-90^{\circ}$, and internal rotation $0^{\circ}-60^{\circ}$ angles). Kinematic data on the shoulder joints were simultaneously obtained using IMU three-dimensional (3D) angular measurement (MyoMotion) and photographic measurement. Test-retest reliability and concurrent validity were examined. Results: The MyoMotion system provided good to very good relative reliability with small standard error of measurement (SEM) and minimal detectable change (MDC) values from all three planes. It also presented acceptable validity, except for some of shoulder flexion, shoulder external rotation, and shoulder abduction. There was a trend for the shoulder joint measurements to be underestimated using the IMU 3D angular measurement system compared to the goniometer and photo methods in all planes. Conclusion: The IMU 3D angular measurement provided a reliable measurement and presented acceptable validity. However, it showed relatively low accuracy in some shoulder positions. Therefore, using the MyoMotion measurement system to assess shoulder joint angles would be recommended only with careful consideration and supervision in all situations.