• Title/Summary/Keyword: Reliability standard

Search Result 1,685, Processing Time 0.024 seconds

A Measure for Travel Time Reliability (통행시간 신뢰성 지표 개발 및 산정에 관한 연구)

  • Chang, Justin Su-Eun;Kang, Ji-Hye;Lee, Seung-Jun
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.5
    • /
    • pp.217-226
    • /
    • 2008
  • The term, travel-time reliability, refers to variations in journey time that travelers cannot predict. The purpose of this paper is to suggest a standard way to measure travel time reliability. A modified buffer time indicator is proposed. The index is represented by the difference between planned and actual travel times based on lognormal type travel time distribution. Using this framework, a constant function for railways and a negative parabola function for roads are discussed. The model developed is applied to the real data of Korean road and rail usages to empirically verify the methodology proposed. In this process, the unit value of travel time reliability for each group is estimated. The result of this research is expected to be helpful of conducting more cautious economic feasibility studies of transport.

Actual Condition and Reliability Monitoring of Material Safety Data Sheets for the Organic Solvents (일부 유기용제의 물질안전보건자료의 실태와 신뢰성 조사)

  • 정규혁;김경례;김대현;오기석;유일재
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.85-91
    • /
    • 2001
  • The regulation of Material safety data sheets(MSDS) was required for the chemicals in use in the workplace from July 1976. Under the provisions of the workplace hazardous materials information system, employers in Korea must be provided with accurate and comprehensive MSDS. To examine the reliability of MSDS for organic solvents, 63 organic solvents and MSDS were collected from the workplace of 39 companies located in Kyonggi province. Manufacture\`s MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. 38 solvents were able to analyze their composition by gas chromatography-mass selective detector(GC-MSD). Among them, 28 solvents were incorrect in their composition and contents. In some case, health hazardous or carcinogenic chemicals which were not included in the MSDS were detected from samples. As a result of evaluating whether the MSDS correspond to the regulation required by Industrial Safety and Health Act (ISHA), the information in the MSDS including hazard classification, occupational exposure level, toxicity, regulatory information were incorrectly provided, and some MSDS did not disclose carcinogenic in their MSDS, and some MSDS were not written in the standard format. From this survey, continuous monitoring and promoting correct MSDS, and analyzing the components of the solvents were required to endure the reliability of MSDS for organic solvents.

  • PDF

A Level II reliability approach to rock slope stability (암반사면 안정성에 대한 Level II 신뢰성 해석 연구)

  • Park, Hyuck-Jin;Kim, Jong-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.319-326
    • /
    • 2004
  • Uncertainty is inevitably involved in rock slope engineering since the rock masses are formed by natural process and subsequently the geotechnical characteristics of rock masses cannot be exactly obtained. Therefore the reliability analysis method has been suggested to deal properly with uncertainty. The reliability analysis method can be divided into level I, II and III on the basis of the approach for consideration of random variable and probability density function of reliability function. The level II approach, which is focused in this study, assumes the probability density function of random variables as normal distribution and evaluates the probability of failure with statistical moments such as mean and standard deviation. This method has the advantage that can be used the problem which the Monte Carlo simulation approach cannot be applied since the complete information on the random variables are not available. In this study, the analysis results of level II reliability approach compared with the analysis results of level III approach to verify the appropriateness of the level II approach. In addition, the results are compared with the results of the deterministic analysis.

  • PDF

Reliability of Scapular Winging Measurement Using a Scapulometer (익상견갑의 평가를 위한 "Scapulometer"의 신뢰도 연구)

  • Weon, Jong-Hyuek;Choi, Houng-Sik;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2010
  • This study was undertaken to develop the scapulometer, a measuring tool for scapular winging, and to determine the reliability of scapulometer. Thirty subjects with scapular winging greater than 2 cm participated in this study. Two examiners measured scapular winging using the scapulometer. Standardized measurement position of each subject was as follows: neutral position of shoulder and wrist, $90^{\circ}$ flexion of elbow, and cuff weight of 5% and 10% of body weight (BW) to neutral wrist. The interrater and intrarater reliability were calculated with an intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and standard error of measurement (SEM) at 5% BW and 10% BW. The level of scapular winging was tested between 5% BW and 10% BW with a paired t-test. The interrater reliability was shown to be high at 5% BW (ICC(2,k)=.955, 95% CI=.900~.979, SEM=.07) and at 10% BW (ICC(2,k)=.968, 95% CI=.930~.985, SEM=.06). The intrarater reliability was shown to be high at 5% BW (ICC(2,k)=.921, 95% CI=.842~.961, SEM=.09) and at 10% BW (ICC(2,k)=.906, 95% CI=.813~.954, SEM=.10). The level of scapular winging was significantly different between 5% BW and 10% BW. Conclusively, it is demonstrated that the scapulometer is an objective and qualitative measurement tool for scapular winging.

ESTIMATION OF RELIABILITY IN A MULTICOMPONENT STRESS-STRENGTH MODEL IN WEIBULL CASE

  • Kim, Jae J.;Kang, Eun M.
    • Journal of Korean Society for Quality Management
    • /
    • v.9 no.1
    • /
    • pp.3-11
    • /
    • 1981
  • A stress-strength model is formulated for s of k systems consisting of identical components. We consider minimum variance unbiased (MVU) estimation of system reliability for data consisting of a random sample from the stress distribution and one from the strength distribution when the two distirubtions are Weibull with unknown scale parameters and same known shape parameter. The asymptotic distribution of MVU estimate of system reliability in the model is obtained by using the standard asymptotic properties of the maximum likelihood estimate of system reliability and establishing their equivalence. Uniformly most accurate unbiased confidence intervals are also obtained for system reliability. Empirical comparison of the two estimates for small samples is studies by Monte Carlo simulation.

  • PDF

A Study on the Team Sharing Spirit Model, Team Effectiveness, Team Cohesion, Team Reliability, and Turnover Intension among Hospital Nurses (병원 간호사의 팀 공유정신, 팀 효과성, 팀 응집력, 팀 신뢰도, 이직의도에 관한 연구)

  • Lee, Jieun;Kong, Jeonghyeon;Lee, Haerang
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.121-131
    • /
    • 2020
  • Purpose : This study was conducted to confirm the correlation between team sharing spirit, team effectiveness, team cohesion, team reliability, and turnover intention of hospital nurses and to identify the influence factors affecting the turnover intention of hospital nurses. Methods : The sample for this study consisted of 200 nurses from four general hospitals of less than 500 beds located in J city. Data were analyzed using frequency, percentage, mean, standard deviation, t-test, ANOVA, Scheffe' test, Pearson Correlation and Hierarchical Multiple Regression. Results : Factors influencing nurse turnover intentions included satisfaction with nursing position (β=.274), team reliability (β=-.250), satisfaction with department (β=-.178), and career (β=.149) in order, and these influence factors accounted for 32.1 % of nurses' turnover intentions. Conclusion : Based on the results of the study, it is necessary to consider ways to reduce the turnover intention of nurses by devising strategies to increase the factors of satisfaction with nursing positions, team reliability, and satisfaction with department by making good use of the resources of the medical institution. It is suggested to conduct repeated studies of nurses working in various clinical sites and further studies applying various outcome variables in the future.

Study of Reliability-Based Robust Design Optimization Using Conservative Approximate Meta-Models (보수적 근사모델을 적용한 신뢰성 기반 강건 최적설계 방법)

  • Sim, Hyoung Min;Song, Chang Yong;Lee, Jongsoo;Choi, Ha-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.80-85
    • /
    • 2012
  • The methods of robust design optimization (RDO) and reliability-based robust design optimization (RBRDO) were implemented in the present study. RBRDO is an integrated method that accounts for the design robustness of an objective function and for the reliability of constraints. The objective function in RBRDO is expressed in terms of the mean and standard deviation of an original objective function. Thus, a multi-objective formulation is employed. The regressive approximate models are generated via the moving least squares method (MLSM) and constraint-feasible moving least squares method (CF-MLSM), which make it possible to realize the feasibility regardless of the multimodality/nonlinearity of the constraint function during the approximate optimization processes. The regression model based RBRDO is newly devised and its numerical characteristics are explored using the design of an actively controlled ten bar truss structure.

Photovoltaic Hybrid Systems Reliability and Availability

  • Zahran, Mohamed B.A.
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.145-150
    • /
    • 2003
  • Reliability, availability, and cost have been the major concerns for photovoltaic hybrid systems since their beginning as primary sources for much critical applications like communication units and repeaters. This paper descnbes the performance of two hybrid systems, photovoltaic-battery, wind-turbine coupled with the public-grid (PVBWG) hybrid system and photovoltaic-battery, wind-turbine coupled With the diesel generator (PVBWD) hybrid system The systems are sized to power a typical 300W/48V de telecommunication load continuously throughout the year Such hybrid systems consist of subsystems, which in turn consist of components Failure of anyone of these components may cause failure of the entire system. The reliability and availability basics, and estimation procedure for the two proposals are introduced also in this paper. The PVBWG and PVBWD system configurations are shown with the relevant mean-time-between-faIlure (MTBF) and failure rate (${\lambda}$) of each component. The characteristics equations of the two systems are deduced as a function of operating hours and the percentage of sun and wind availabilities per day. The system probability failure as well as the reliability is estimated based on the fault tree analysis technique. The results show that, by using standard or normal components MTBF, the PVBWG is more reliable and the time of periodic maintenance period is more than one year especially in the rich sites of both sun and wind, but PVBWD competes else Also, in the first five years from the system installation, the system is quit reliable and may not require any maintenance. The results show also, as the sun and wind are available, as the system reliable and available.

Review on Reliability and Validity of Questionnaire of Pattern Identification in Traditional Chinese Medicine -Using China National Knowledge Infrastructure- (중의 변증 설문도구의 신뢰도 및 타당도 고찰 -China National Knowledge Infrastructure를 이용하여-)

  • Yeo, Min Kyung;Dong, Sang Oak;Lee, Young Seop;Jang, Eun Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.246-255
    • /
    • 2015
  • The purpose of this study is to investigate the reliability and validity of the questionnaire of pattern identification (PI) in traditional chinese medicine (TCM), through the systematic review of china national knowledge infrastructure (CNKI) database. We searched the articles related with reliability and validity of the questionnaire of PI and published from January 1994 to December 2013. Seventeen questionnaires were analyzed in this study. The twelve (70.6%) questionnaires were developed on the base of specific disease, and five (29.4%) ones were developed on the base of non-specific disease. Three of PI questionnaires showed low inter-item consistency reliability. Exploratory factor analysis of construct validity, content validity, and criterion validity analysis were commonly used on the assessment of validity, but none of them was analysed at the same study. There was only one questionnaire of the ischemic stroke that examined the sensitivity and specificity of both training and test groups in spite of the absence of a gold standard.

Reliability testing equipment for SF_6 gas load break switch (가스절연부하개폐기의 신뢰성 평가장비)

  • Heo J.C.;Park S.J.;Kang Y.S.;Koh H.S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.560-562
    • /
    • 2004
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability Accordingly, the national standard(RS C0031) was made for the reliability assessment of $SF_6$ gas load break switch and the testing facilities were also set in KERI(Korea Electrotechlology Research Institute). This paper presents the requirements of RS C0031 for reliability assessment of $SF_6$ gas load break switch and synopsis of the accelerated life testing facilities for $SF_6$ gas load break switch.

  • PDF