• Title/Summary/Keyword: Reliability standard

Search Result 1,685, Processing Time 0.027 seconds

Reliability analysis of strip footing under rainfall using KL-FORM

  • Fei, Suozhu;Tan, Xiaohui;Gong, Wenping;Dong, Xiaole;Zha, Fusheng;Xu, Long
    • Geomechanics and Engineering
    • /
    • v.24 no.2
    • /
    • pp.167-178
    • /
    • 2021
  • Spatial variability is an inherent uncertainty of soil properties. Current reliability analyses generally incorporate random field theory and Monte Carlo simulation (MCS) when dealing with spatial variability, in which the computational efficiency is a significant challenge. This paper proposes a KL-FORM algorithm to improve the computational efficiency. In the proposed KL-FORM, Karhunen-Loeve (KL) expansion is used for discretizing random fields, and first-order reliability method (FORM) is employed for reliability analysis. The KL expansion and FORM can be used in conjunction, through adopting independent standard normal variables in the discretization of KL expansion as the basic variables in the FORM. To illustrate the effectiveness of this KL-FORM, it is applied to a case study of a strip footing in spatially variable unsaturated soil under rainfall, in which the bearing capacity of the footing is computed by numerical simulation. This case study shows that the KL-FORM is accurate and efficient. The parametric analyses suggest that ignoring the spatial variability of the soil may lead to an underestimation of the reliability index of the footing.

Evaluation of alveolar crest bone loss via premolar bitewing radiographs: presentation of a new method

  • Safi, Yaser;Kadkhodazadeh, Mahdi;Safai, Pooria;Esmaeelinejad, Mohammad;Shamloo, Nafiseh
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.222-226
    • /
    • 2014
  • Purpose: This study aimed to assess the interdental bone level in premolar bitewing radiographs while retracting the cheeks. Methods: Seventy-two horizontal bone defects were created on dried mandibles and maxillae. The distance from the bone level to the cement-enamel junction of premolars was detected by a modified digital caliper (considered the gold standard). The reliability of all radiographs was assessed by intraclass correlation coefficient (ICC), and the validity was compared to the gold standard using the analysis of variance test. P-values less than 0.05 were considered statistically significant. Results: This study showed that the reliability of radiographs without a cheek simulator and with 0.16 second exposure time was significantly higher than that of the two other groups (ICC=0.96 compared to 0.93 and 0.88, respectively). The results from the radiographs without a cheek simulator and with 0.16 second exposure time were more similar to the gold standard measures than those of the two other groups, although the difference was not statistically significant. Conclusions: Retracting the buccal soft tissue plays an important role in increasing the accuracy of radiographs in detecting the interdental alveolar bone level and produces more accurate results than increasing the exposure time, although it does not have a significant role in reliability of results.

A Study about Reliability of Sasang Constitutional Voice Diagnosis according to Operator Presence (전문조작원 유무에 따른 사상체질 음성진단의 신뢰성 분석)

  • Park, Hyun Jun;Kim, Jong-Yeol;Jang, Jun-Su
    • Journal of Sasang Constitutional Medicine
    • /
    • v.28 no.4
    • /
    • pp.309-319
    • /
    • 2016
  • Objectives This study was aimed to analyze the reliability of vocal features and probabilities for being in Sasang constitutional types calculated from Sasang constitutional voice diagnosis system according to operator presence. Methods We acquired 96 voice recordings from one male and one female for 4 days. For the first 2 days, the subjects recorded their voice by themselves. For the last 2 days, they recorded according to the instruction of an operator following the standard operating procedure. We analyze the standard deviations of vocal features, probabilities for being three constitutional types, Tae-Eum (TE), So-Yang (SY), and So-Eum (SE) Results In the case of the female, coefficients of variations of the voice variables and the probabilities for being each constitutional type were all within 20%. In the case of the male, coefficients of variations were all within 20% except one variable. Even if there was no instruction from the operator, standard deviations of the probability did not increase for both genders. When recorded without the operator, for male, the probability for being SE decreased by 3.2%. For female, the probability for being TE increased by 5.438%, and that of SE decreased by 3.057%, and that of SY decreased by 2.394%. Conclusions When recorded without operators, for men, there was a significant difference in the probability for being SE. And for women, there were significant differences in the probabilities for all constitutional types.

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

Reliability of rehabilitative ultrasound imaging for measuring the gluteus maximus muscle at rest and during contraction

  • Jeong, Ju-Ri;Lee, Su-Jin;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of rehabilitative ultrasound imaging (RUSI) for measurement of muscle thickness with changes in angles of the gluteus maximus (GM) at rest and during contraction. Design: Cross-sectional study. Methods: Twenty-two healthy men volunteered for this study. GM muscle images were obtained in the resting position and during prone hip extension with knee flexion at hip abduction angles of $0^{\circ}$ and $30^{\circ}$, respectively. Two examiners randomly measured the thickness of the GM twice in three different positions. The first position was a comfortable prone position. The second position was prone hip extension with knee flexion (PHEKF) to $90^{\circ}$. The third position was achieved by hanging a 1-kg weight on the ankle of the lifted leg during PHEKF with the angle of the lifted leg the same as the second position. Intra-class correlation coefficients (ICCs), standard error measurements, and minimal detectable changes were used to estimate reliability. Results: The intra-rater reliability ICCs (95% confidence interval) of the GM were >0.870, indicating good reliability. Inter-rater reliability ICCs ranged from 0.668 to 0.913. The reliability of measurements of muscle thickness at each position was similar to the reliability of the angle change. Differences in muscle thickness and ratios for each position with $0^{\circ}$ and $30^{\circ}$ of hip abduction were not statistically significant. Conclusions: In the present study, the intra-rater reliability of muscle thickness measurements of the GM was good, and the inter-rater reliability was moderate to good. Reliable RUSI measurements of wide and large muscles, such as the GM muscle at rest and during contraction, are feasible. Further investigation is required to establish the reproducibility of the protocols presented in this study.

Reliability Study for Upgrade of Diagnosis System of Oriental Medicine DSOM(r) S.1.1 (한방진단설문지 DSOM (r) S.1.1의 Upgrade를 위한 신뢰도 연구)

  • Lee, In-Seon;Kim, Jong-Won;Chi, Gyoo-Yong;Lee, Yong-Tae;Kim, Kyu-Kon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.1
    • /
    • pp.88-97
    • /
    • 2012
  • DSOM(Diagnosis System of Oriental Medicine), questionnaire for oriental medical(medicine) diagnosis is an online survey system containing 152 questions for female, 149 questions for male that asking the basic symtoms of 16 pathogenic factors(病機). The result of DSOM denotes reliability according to the level of major symptoms of each pathogenic factor. Standard level of reliability is equal to all 16 pathogenic factor basically except phlegm(痰). In case of phlegm(痰) we give different weight depending on whether the factor includes gray color under the orbit(痰飮氣) or not. To examine reliability of DSOM, statistical analysis has been done to the data of felmale 10101, male 1564 except for bad responses and stored between 1st April 2000 to 3rd June 2011. Based on the study, the conclusions were as follows. Reliability of DSOM. For female, all pathogenic factors showed over 85% confidence level except for phlegm 82.6%. For male, all pathogenic factors showed more than 90% confidence level except two factors, phlegm(痰) indicates 87.% and damp(濕) indicates 89.8%. HH rates among pathogenic factors were more than 50 points. For female, HH rates of other 14 pathogenic factors were all over 80% except for heat(熱) 78.2% and insufficiency of Yang(陽虛) 75.3%. For male HH rates of all pathogenic factors were more than 80% except HH rates of heat 78.2% and damp 77.8%. Research based on a degree of satisfaction of reliability derived from pathogenic factors with scores of HH results in for all 16 pathogenic factors showed over 85% of relatively high level of satisfaction for both sexes whose reliability standard come under 5~4 points. Comparing appearance frequency of pathogenic factors for both sexes. Male only displays higer than female in heat(熱). Whereas female were higher than male for other 15 pathogenic factors and the difference was biggest in heart(心) and least in insufficiency of Yin(陰虛). Comparing appearance frequency order of pathogenic factors for both sexes. Female outdistanced male in blood stasis(血瘀) coldness(寒) blood-deficiency(血虛) phlegm(痰), while male outdistance female in heat(熱) insufficiency of Yin(陰虛) deficiency of qi(氣虛). Male had lower average of each pathogenic factors than female except heat(熱) as well as deficiency of qi(氣虛).

Reliability and Validity of the Postural Balance Application Program Using the Movement Accelerometer Principles in Healthy Young Adults

  • Park, Seong-Doo;Kim, Ji-Seon;Kim, Suhn-Yeop
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.52-59
    • /
    • 2013
  • The purpose of this study was to determine the reliability and validity of the postural balance program which uses the movement accelerating field principles of posture balance training and evaluation equipment and smartphone movement accelerometer program (SMAP) in healthy young adults. A total of 34 people were appointed as the subject among the healthy young adults. By using Biodex stability system (BSS) and SMAP on the subject, the posture balance capability was evaluated. For the test-retest reliability, SMAP showed the intra-class correlation (ICC: .62~.91) and standard error measurement (SEM: .01~.08). BSS showed the moderate to high reliability of ICC (.88~.93) and SEM (.02~.20). In the reliability of inter-rater, ICC (.59~.73) as to SMAP, showed the reliability of moderate in eyes open stability all (EOSA), eyes open stability anterior posterior (EOSAP), eyes open stability medial lateral (EOSML) and eyes open dinamic all (EODA), eyes open danamic anterior posterior (EODAP), and eyes open danamic medial lateral (EODML). However, ICC showed reliability which was as low as .59 less than in other movements. In addition, BSS showed the reliability of high as ICC (.70~.75). It showed reliability which was as low as ICC (.59 less than) in other movements. In correlation to the balance by attitudes between SMAP and BSS, EOSML (r=.62), EODA (r=.75), EODML (r=.72), ECDAP (r=.64), and ECDML (r=.69) shown differ significantly (p<.05). However, the correlation noted in other movements did not differ significantly. Therefore, SMAP and BSS can be usefully used in the posture balance assessment of the static and dynamic condition with eyes opened and closed.

Reliability and validity of rasterstereography measurement for spinal alignment in healthy subjects

  • Yi, Yoon-Sil;Yoo, Seul-Ki;Lee, Da-Gam;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • Objective: The Back Mapper is one type of Rasterstereography and it can be used in the clinic without radiation exposure. The purpose of our study was to prove the reliability and validity of the Back Mapper and to compare it with the Spinal Mouse, which is an assessment tool for spinal curvatures using a wheeled mouse, and the Cobb angle by X-ray. Design: Cross-sectional study. Methods: Twenty healthy adults participated in the test to investigate for the inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with assessment devices for scoliosis such as the Back Mapper, Spinal Mouse and Cobb's angle. Data was analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement for reliability and correlation analysis for validity. Results: Intra-rater reliability of the Back Mapper was good (Cronbach's ${\alpha}$=0.821-0.984, ICC=0.696-0.969) except for assessing the lordotic angle. Inter-rater reliability was good (Cronbach's ${\alpha}$=0.870-0.958, ICC=0.770-0.919) in assessment for trunk imbalance, rotation of scapulae, thoracic angle, lumbar angle, and kyphotic angle. The kyphotic angle in the Spinal Mouse had a significant correlation icompared with the Back Mapper (r=0.510, p<0.05), and the Cobb's angle from an X-ray had a significant correlation with trunk inclination (r=0.532, p<0.05). Conclusions: These findings provide good intra-reliability of the Back Mapper in healthy subjects, but the Back Mapper requires more experienced practice to have good inter-reliability. Also, the variables of the Back Mapper does not seem as appropriate compared with the Cobb angle by X-ray.

HIERARCHICAL ERROR ESTIMATORS FOR LOWEST-ORDER MIXED FINITE ELEMENT METHODS

  • Kim, Kwang-Yeon
    • Korean Journal of Mathematics
    • /
    • v.22 no.3
    • /
    • pp.429-441
    • /
    • 2014
  • In this work we study two a posteriori error estimators of hierarchical type for lowest-order mixed finite element methods. One estimator is computed by solving a global defect problem based on the splitting of the lowest-order Brezzi-Douglas-Marini space, and the other estimator is locally computable by applying the standard localization to the first estimator. We establish the reliability and efficiency of both estimators by comparing them with the standard residual estimator. In addition, it is shown that the error estimator based on the global defect problem is asymptotically exact under suitable conditions.

Plastic Displays Made by Standard ${\alpha}$-Si TFT Technology

  • Battersby, Steve;Ian, French
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1546-1549
    • /
    • 2006
  • We have developed $EPLaR^{TM}$, a new way of making flexible electrophoretic displays. The TFTs have the same good performance, reliability and mature manufacturing processes as TFTs used in LCD monitors and LCD-TVs. We are working with partners to show that plastic displays can be made in existing TFT-LCD factories alongside glass LCDS. In this talk we describe the EPLaR process and show results for TFT arrays on plastic made in a factory by standard ${\alpha}$-Si TFT processing.

  • PDF