• Title/Summary/Keyword: Reliability standard

Search Result 1,693, Processing Time 0.224 seconds

Reliability-based assessment of damaged concrete buildings

  • Sakka, Zafer I.;Assakkaf, Ibrahim A.;Qazweeni, Jamal S.
    • Structural Engineering and Mechanics
    • /
    • v.65 no.6
    • /
    • pp.751-760
    • /
    • 2018
  • Damages in concrete structures due to aging and other factors could be a serious and immense matter. Making the best selection of the most viable and practical repairing and strengthening techniques are relatively difficult tasks using traditional methods of structural analyses. This is due to the fact that the traditional methods used for assessing aging structure are not fully capable when considering the randomness in strength, loads and cost. This paper presents a reliability-based methodology for assessing reinforced concrete members. The methodology of this study is based on probabilistic analysis, using statistics of the random variables in the performance function equations. Principles of reliability updating are used in the assessment process, as new information is taken into account and combined with prior probabilistic models. The methodology can result in a reliability index ${\beta}$ that can be used to assess the structural component by comparing its value with a standard value. In addition, these methods result in partial safety factor values that can be used for the purpose of strengthening the R/C elements of the existing structure. Calculations and computations of the reliability indices and the partial safety factors values are conducted using the First-order Reliability Method and Monte Carlo simulation.

A Study on the Reliability Demonstration for Korea High Speed Train Control System (한국형고속철도 열차제어시스템 하부구성요소 신뢰도입증에 관한 연구)

  • Lee, Jae-Ho;Lee, Kang-Mi;Kim, Young-Kyu;Shin, Duc-Ko
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.732-738
    • /
    • 2006
  • This research provides a scheme for Highly Accelerated Stress Test that is necessary to demonstrate reliability prediction of Korean Rapid Transit Railway Train Control System sub-equipment, which is calculated by a relevant standard for failure rate prediction of electronic products. Although determining failure information generated in the process of trial running by statistic analysis is widely accepted as a measure of confirmation for reliability prediction, this research suggests the modeling for System Life Test determined by accelerating stress factors as a measure of confirmation for reliability prediction of sub-equipment unit that is generated ahead of a trial running in System Life Cycle. Consequently, the research demonstrates sub-equipment unit reliability test, which is based on the model derived from Accelerated Stress Test, according to accuracy level and the number of samples, and conducts an official experiment by making out a reliability test procedure sheet based on test time as well.

Reliability Analysis on the Decision Method of Lateral Flow of Foundation Piles for Abutment (교대 기초말뚝의 측방유동 판정식에 관한 신뢰성 해석)

  • Ahn, Jong-Pil;Kim, Gyu-Deok;Kim, Il-Goo;Choi, Jin-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1090-1097
    • /
    • 2008
  • This study conducted the decision method of lateral flow in abutment structures founded on the soft soils and the reliability analysis on the foundation pile for abutment. On the basis of the results, this study proposed the reliability design model. Reliability analysis was conducted by applying second moment method, point estimation method, and expected total cost minimization to lateral movement index, lateral movement decision index, modified lateral movement decision index, and circular failure safety factor for the decision criteria of lateral flow. The reliability index by analysis method had a similar tendency each other. Point estimation method was found as a practical method in the aspect of convenience because it could conduct the analysis only by mean and standard deviation as well as the partial derivative on random variables was not necessary. Optimum reliability index and optimum safety according to increasing in failure factors and load ratio were analyzed and loads and resistance factors of the design criteria of optimum reliability were estimated. It presented rational design model which can consider construction level and stability and economical efficiency overall.

  • PDF

Novel Hierarchical Test Architecture for SOC Test Methodology Using IEEE Test Standards

  • Han, Dong-Kwan;Lee, Yong;Kang, Sung-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.293-296
    • /
    • 2012
  • SOC test methodology in ultra deep submicron (UDSM) technology with reasonable test time and cost has begun to satisfy high quality and reliability of the product. A novel hierarchical test architecture using IEEE standard 1149.1, 1149.7 and 1500 compliant facilities is proposed for the purpose of supporting flexible test environment to ensure SOC test methodology. Each embedded core in a system-on- a-chip (SOC) is controlled by test access ports (TAP) and TAP controller of IEEE standard 1149.1 as well as tested using IEEE standard 1500. An SOC device including TAPed cores is hierarchically organized by IEEE standard 1149.7 in wafer and chip level. As a result, it is possible to select/deselect all cores embedded in an SOC flexibly and reduce test cost dramatically using star scan topology.

Evaluation of Pull-out Performance of Torsion Control Expansion Anchor According to Drill Bit Diameter (드릴비트 직경에 따른 비틀림 제어 확장 앵커의 인발성능 평가)

  • Kyoung-Hun Chae;Tae-Wo Park;Moo-Won Hur;Yeong-Seung An;Ju-Yeon Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.64-70
    • /
    • 2023
  • In this study, reliability tests of torsion control expansion anchors according to drill bit diameters were performed. The standard deviation and coefficient of variation of the anchor were reviewed through the tests for each variable, and the results were compared and evaluated with the standard test results. As a result of the reliability test of the M12 and M16 anchors with 1.04 times the drill bit diameter, they were within 20% of the ultimate tensile load permissible standard coefficient of variation. It was found that the pulling-out performance of the anchor installed in the large hole was sufficiently secured. However, it was found to be about 253% and 210% of the design strength, indicating that the pulling performance of the anchor installed in 1.04 times the drill bit diameter was sufficiently secured. As a result of the reliability test of the M12 and M16 anchors with 1.02 times the drill bit diameter, the value of the coefficient of variation of the ultimate tensile load limit was within 20%, which satisfies the test standard. It was shown to be about 136% and 168% of the design strength, indicating that the pulling-out performance of the anchor installed in 1.02 times the drill bit diameter is sufficiently secured.

Reliability of the Joint Neutral Position and Measurement Methods of the Ankle Joint Complex Range of Motion (발목관절 복합체의 가동범위 측정을 위한 중립위치와 측정방법의 신뢰도)

  • Hong, Wan-Sung;Kim, Gi-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.4
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: To determine the correct measurement methods of the ankle joint complex range of motion for measuring the neutral position and evaluate the rater reliability. In addition, the impact of training on the rater reliability was also assessed. Methods: The subjects were eleven healthy women, who were evaluated by two physical therapists and one physical therapist recorded the results of the study. Standard goniometer was used as the measurement tool. The ankle and subtalar joint neutral position and the active range of motion of the ankle and subtalar joint were measured. Intra-rater reliability and inter-rater reliability measures were analyzed with intraclass correlation coefficients. Results: Intra-rater reliability and inter-rater reliability ranged from high to medium for the neutral position of the ankle joint complex. Intra-rater reliability for dorsiflexion and plantarflexion measurements was medium, while the inter-rater reliability was high. The range of motion of the subtalar joint was measured, and the intra-rater reliability and inter-rater reliability were low and medium, respectively Also, the intra-rater reliability was increased with formal training of the measurement techniques. Intra-rater reliability was reduced in case the raters had not undertaken the training. Conclusion: In summary, the results obtained with the measurement tools and joint measurement of position, indicate the consistency of repeated measurements made by the same observers. Under the same circumstances along with repetition of the same measurement technique during training caused an increase in the rater reliability of formally trained raters.

Development of Certified Reference Materials for Specific Surface Area (비표면적 인증표준물질 개발)

  • Choi, Byung Il;Kim, Jong Chul;Kim, Taeyoung;Nham, Hyunsoo;Kwon, Su Yong
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.74-84
    • /
    • 2005
  • Understandings of adsorption characteristic of interface are very important in several advanced materials processes, related to NT and BT technology. Volumetric gas adsorption method, suitable for absolute measurements, is regarded as the standardized measurement technique for specific surface area. In order to verify the reliability of commercial equipments, certified reference materials (called CRM) of specific surface area are developed and evaluated its uncertainty factors by standard equipment which has traceability to SI units. Specific surface areas of developed materials are $10.72{\pm}0.46m^2g^{-1}$ for silicon nitride powders and $149.50{\pm}3.44m^2g^{-1}$ for alumina. These disseminations of CRMs would result in improved reliability chains in industrial processes, and lead eventually to contribution to productivity improvement, quality management, safety evaluation, and possibly to new material development.

Studies on the Standardization of pH Measurement System (pH 측정 시스템의 표준화에 관한 연구)

  • Lee, Hwa Shim;Kim, Myung Soo;Kim, Jin Bok;Oh, Sang Hyup
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.432-442
    • /
    • 1998
  • Since the definition of pH, $pH=-Ioga_H$ is based on a single ion activity, pH values can not be determined with measurement itself, but require an approximation method. They are derived from EMF measurement of a liquid junction free cell using hydrogen and Ag/AgCl electrodes. Primary standard materials with certified pH values can be obtained with this approximation method. Standard buffer solutions are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values can be obtained with this approximation method. Standard buffer solution are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values of sample solutions. To certify the pH values, we have established the system for the primary standard measurement and certified the pH of buffer solutions in the range of 1.6∼12.5 pH unit within uncertainty of ${\pm}0.005$ pH unit.

  • PDF

Suggestion of Standard Process in Developing Questionnaire of Pattern Identification (한의 변증 설문지 개발 표준프로세스 제안)

  • Jang, Eunsu;Lee, Eun Jung;Yun, YongGi;Park, Yang Chun;Jung, In Chul
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.190-200
    • /
    • 2016
  • The aim of this study was to suggest the standard process in developing Questionnaire of Pattern Identification (QPI). The process in developing QPI was researched from validated and developed questionnaire and the standard process in developing QPI was suggested through review of the experts in research, statistics and clinics. Check list was also provided. The number of QPI reviewed in this research was 17(4 in disease in Korea Medicine, 5 in Pathological symptoms, 6 in Sasang constitutional Diagnosis, and 2 in etc), The standard process in developing QPI consisted of 11 phage and 33 check lists. 1) Composition of Research Member(3check lists), 2)Set up of the Aim(5), 3) Review for advanced research(3), 4) Finding an Important Index(3), 5) Review of item selection(4), 6) Developing the questions using items(5), 7) Developing Draft of Questionnaire(2), 8) 1st Survey of Reliability and Validity(2), 9) Revision and Correction of Item(1), 10) 2st Survey of Reliability and Validity(2), 11) Completion and Application(3). This study suggests the standard process in developing QPI for the first time in Korea. This following step may help A new QPI development.

A study on standardization through the analysis of the survey on the use of fishery sea anchor (어업용 씨앵커의 사용실태 분석을 통한 표준화 연구)

  • KIM, Namgu;KIM, Hyung-Seok;LEE, Yoo-Won;RYU, Kyung-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.1
    • /
    • pp.10-18
    • /
    • 2022
  • Fishery sea anchor is widely used for many fishing vessels. However, standardization of the dimension and terminology of the fishery sea anchor has not been achieved, reducing the reliability of the performance and safety of the fishery sea anchor. Therefore, this study researches the reality of usage of fishery sea anchor and then attempts to suggest the development direction of the standard draft as basic data. As a result of the survey on the reality of usage show that various terms were used for each part of the fishery sea anchor (including the incorrect form of non-standard words derived from Japanese) and that the production of this product in the fishery sea anchor market was concentrated on one specific manufacturer. In addition, the main specifications of the fishery sea anchor are set and manufactured based on conventional experience without standards. In the field, there was no standardized drawing for fishery sea anchor and users had low awareness of the main specifications of fishery sea anchor. Therefore, this study suggested the following regarding the fishery sea anchor: standard terms for each part including Korean and English names and standard drawing of sea anchor. It is hoped that this study will contribute to research for the standardization of fishery sea anchor, which will increase in reliability and lead to increased interest in standardization in the fishery field.