• Title/Summary/Keyword: Reliability growth

Search Result 819, Processing Time 0.03 seconds

Securing Operation Margin Capacity as Coordination Control among the Power Compensation Equipments (전력보상설비의 상호 협조제어에 따른 운영여유용량의 확보)

  • Lee, Sang-Deok;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1011-1016
    • /
    • 2010
  • It is an important issue to electric power system operations that it can reliably supply large-capacity power to consumption area as due to increasing power demand growth. For this purpose, The FACTS equipment based on Power IT technology with the existing mechanical compensators has been applied to power system. Therefore we suggest on this paper that a plan for coordination control of multiple power compensation equipment in order to increase the utilization of each facility and secure operation margin capacity. As the result of simulation, it is possible to cope actively with a suddenly changed power system. This helps greatly for the voltage stability and supply reliability in a suddenly changed power system.

Application of Effective Asset Management for Power Generation (발전설비를 위한 효과적인 자산관리기법 적용)

  • Lee, Sung-Hun;Kim, Hyeon-Il;Chang, Jeong-Ho;Lee, Kwang-Ho;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.163_164
    • /
    • 2009
  • Today, the power utilities is setting on the slow load growth and the aging of power equipment, then could spend the efforts on the stability of system performance. The asset management is separated by three parts of essential elements : management, engineering and information. The corporate of these parts should be practiced that seek to balance. Asset management is great way to fulfill the economic investment and the stability of system performance. This paper presents the application of effective asset management considering the economic evaluation for reasonable investment, technical evaluation for accurate control management and reliability evaluation for stability of operation.

  • PDF

Effect analysis of thermal-mechanical behavior on fatigue crack of flip-chip electronic package (플립 칩 전자 패키지의 피로 균열이 미치는 열적 기계적 거동 분석)

  • Park, Jin-Hyoung;Lee, Soon-Bok
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1673-1678
    • /
    • 2007
  • The use of flip-chip type electronic package offers numerous advantages such as reduced thickness, improved environmental compatibility, and downed cost. Despite numerous benefits, flip-chip type packages bare several reliability problems. The most critical issue among them is their electrical performance deterioration upon consecutive thermal cycles attributed to gradual delamination growth through chip and adhesive film interface induced by CTE mismatch driven shear and peel stresses. The electronic package in use is heated continuously by itself. When the crack at a weak site of the electronic package occurs, thermal deformationon the chip side is changed. Therefore, we can measure these micro deformations by using Moire interferometry and find out the crack length.

  • PDF

Analysis of Deperming Performance According to Deperming Protocol Transform of Vessel Model (함정모델의 탈자프로토콜 변화에 따른 탈자성능 분석)

  • Kim, Jong-Wang;Kim, Ji-Ho;Park, Hyun-Soo;Jung, Hyun-Ju;Lee, Hyang-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1693-1699
    • /
    • 2011
  • In this paper, for magnetic silence technology of naval vessel, is to make lab deperm system and to evaluate the deperm capacity of naval vessel regarding deperm protocol. Initial permanent magnetic field of naval vessel is magnetized before deperm, having the magnetic field of the same size, to evaluate the deperm capacity regarding a variety of deperm protocol for experimental reliability growth. Current dead time effect of deperm protocol is measured at the different initial current, which are 8A, 6A and 4A respectively. Furthermore, the experiment under the same condition except changing duty cycle into 50% is carried out. As a result, it is possible to compare the six different experiment outcomes. The result shows that the experiment with dead time improve the deperm capacity more than 48.51 percent comparing to the case without dead time.

J-R Curve Evaluation According to the Crack Length Measurement Techniques Under Reverse Cyclic Loading (역사이클하중하에서의 균열길이 측정법에 따른 파괴저항곡선의 평가)

  • 원종일;우흥식;석창성
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.96-101
    • /
    • 1998
  • J-R curve tests were performed on 1T compact specimens of SA516 Gr. 70 carbon steels under reverse cyclic loading. A Direct-Current Potential Drop (DCPD) method, one of the nondestructive techniques to detect flaw of structure, is being increasingly used for monitoring crack initiation and stable crack growth in typical fracture mechanics specimens for J-R testing. In many aspects this method is simpler than the unloading compliance method. The objective of this paper is to evaluate the J-R Curve according to the crack length measurement techniques under reverse cyclic loading. In order to prove the reliability and repeatability of the DCPD method, the crack length measured by using DCPD method was compared to one determined from unloading compliance. Consequently, this DCPD method correlated well with J-R curves and crack extension measurements determined from unloading compliance method.

  • PDF

A study on Voltage Sag Detection of Power Quality Compensator (전력품질 보상장치의 순간전압강하에 관한 연구)

  • Lee jae-young;Lee won-sun;Han Woon-Dong;Jeon hee-jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.760-763
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic, and medical devices sensitive to power quality has caused many power quality problems and power supply-and-demand problem. Recently, in power system not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer), UPS, and APF are being studied more and more. Hence, in this paper, Voltage sag detection algorithm for voltage sag corrector is proposed. Also, simple circuit for the experimental voltage sag is Introduced.

  • PDF

Design of Voltage Controller of DVR based on DSP (DSP를 기반으로한 DVR의 전압제어기 구현)

  • Lee won-sun;Kim soo-gon;Lim Byung-Kuk;Jeon hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.566-569
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Recently, in power system, not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer) are being studied more and more. The DVR is a series compensator which can instantaneously compensate a voltage variation in supply side, and is a more effective than a existing UPS(Uninterruptible Power Supply) which can be only used in limited range of loads such as single load. Hence, in this paper, a study of inverter side L-C filter output Voltage for DVR is discussed.

  • PDF

The Best Generation Mix considering CO2 Air Pollution Constraint ($CO_2$ 배출량제약을 고려한 최적전원구성)

  • Lee, Sang-Sik;Tran, TrungTinh;Kwon, Jung-Ji;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.149-151
    • /
    • 2005
  • A new approach considering CO2 air pollution constraints in the long-term generation mix is proposed under uncertain circumstances. A characteristic feature of the presented approach in this paper is what effects give the air pollution constraints in long term best generation mix. Best generation mix problem is formulated by linear programming with fuel and construction cost minimization with load growth, reliability (reserve margin rate) and air pollutionconstraints. The proposed method accommodates the operation of pumped-storage generator. It was assumed in this study that the construction planning of the hydro power plants is given separately from the other generation plans. The effectiveness of the proposed approach is demonstrated by applying to the best generation mix problem of KEPCO-system, which contains nuclear, coal, LNG, oil and pumped-storage hydro plant multi-years.

  • PDF

The development and implementation of airconditioner control system for peak load clipping (하계 피크전력 감소를 위한 냉방기제어시스템 개발 및 적용)

  • 문홍석;조선구;이원빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.783-787
    • /
    • 1996
  • The rapid growth of air conditioning load has become a main reason of peak load increase in summer. In connection with this, we surveyed the load management projects of utilities world wide and their detailed activities. This study is to develop a remote load control system using computer and radio communications. We finished the field-test of this system on August 1995 in Seoul area. During the field-test, the remote load control of air conditioners was proved to be well-timed. Two control modes, group control and all control, are available for the user to select. The transmission reliability of the load control signal was very good and the functions of system hardware as well as the software were excellent. So we confirmed the applicability of the load control system including the pager communication network. In this paper, detailed information on the system functions and experimental results are described.

  • PDF

Development of diagnostic scale for life planning in late Adolescence (청년기 생활설계 진단척도 개발)

  • Choi, Bo-A
    • Journal of Families and Better Life
    • /
    • v.28 no.5
    • /
    • pp.101-111
    • /
    • 2010
  • The purpose of this study was to develop a standardized scale to diagnostic life planning in late adolescence. A preliminary 32 item scale was developed through a literature review & a survey. 896 people responded to an online survey using the preliminary scale. A series of test, such as test-retest, item-to-total correlation, factor analysis and Cronbach' ${\alpha}$ reliability were conducted using the survey data and a scale comprising 31 items was constructed finally. The diagnostic scale for life planning in late Adolescence consisted of seven factors : (1) complete growth minds (2) life- plan (3) variety experiences (4) close relationships (5) management of healthy body (6) practical finance-plans (7) active preparation of future job. The scale is useful as a guideline for managing life of the late Adolescence. And it is helpful to them to make plan for the better life.