• Title/Summary/Keyword: Reliability assessment

Search Result 2,331, Processing Time 0.034 seconds

Risk Assessment for a Bridge System Based upon Response Surface Method Compared with System Reliability (체계신뢰성 평가와 비교한 응답면기법에 의한 교량시스템의 위험성평가)

  • Cho, Tae-Jun;Moon, Jae-Woo;Kim, Jong-Tae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.295-300
    • /
    • 2007
  • Probabilistic Risk Assessment considering statistically random variables is performed for the preliminary design of a Arch Bridge. Component reliabilities of girders have been evaluated using the response surfaces of the design variables at the selected critical sections based on the maximum shear and negative moment locations. Response Surface Method (RSM) is successfully applied for reliability analyses for this relatively small probability of failure of the complex structure, which is hard to be obtained by Monte-Carlo Simulations or by First Order Second Moment Method that can not easily calculate the derivative terms of implicit limit state functions. For the analysis of system reliability, parallel resistance system composed of girders is changed into parallel series connection system. The upper and lower probabilities of failure for the structural system have been evaluated and compared with the suggested prediction method for the combination of failure modes. The suggested prediction method for the combination of failure modes reveals the unexpected combinations of element failures in significant]y reduced time and efforts compared with the previous permutation method or system reliability analysis method.

  • PDF

Development and Validation of the New Version of Spirituality Assessment Scale (영성 측정도구 개발과 평가)

  • Ko, Il-Sun;Choi, Soyoung;Kim, Jin Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.1
    • /
    • pp.132-146
    • /
    • 2020
  • Purpose: The purpose of this study was to develop a new version of Spirituality Assessment Scale (N-SAS) and verify its reliability and validity. Methods: The total of 59 preliminary items for the N-SAS were selected through a literature review, two rounds of experts' content validation, cognitive interviews, and pre-tests. Verification of its reliability and validity was divided into two phases. In Phase I, questionnaires were collected from 219 adults. Reliability was tested using Cronbach's alpha, validity with item analysis, and exploratory factor analysis. In Phase II, questionnaires developed based on the results of Phase I were collected from 225 adults. Reliability was tested using Cronbach's alpha, validity with confirmatory factor analysis, and criterion validity. Results: The final version of the N-SAS comprised two dimensions (vertical and horizontal), four domains (relationship with God; meaning of life and self-integration; self-transcendence; and relationship with others, neighborhoods, and nature), and 44 items were identified. Total Cronbach's α was .97; those of each subscale ranged from .79 to .98. N-SAS scores were positively correlated with the scores of Howden's Spiritual Assessment Scale (r=.81, p<.001). Conclusion: Findings suggest that the N-SAS can be used to measure spirituality in adults. The use of N-SAS is expected to facilitate perceiving patient's spiritual needs and providing spiritual care.

The Validity and Reliability of a Korean Version of the Diabetes Self-Care Barriers Assessment Scale for Older Adults with Type 2 Diabetes (제2형 당뇨노인을 대상으로 한 당뇨 자가관리 방해요인 사정도구(DSCB-OA) 한국어 버전의 타당도와 신뢰도 검증)

  • Chang, Sun-Ju;Kang, Kyung-Ja
    • Journal of muscle and joint health
    • /
    • v.17 no.2
    • /
    • pp.183-191
    • /
    • 2010
  • Purpose: The purpose of this study was to test the validity and reliability of the Diabetes Self-Care Barriers Assessment Scaler for Older Adults (DSCB-OA) in Korean older adults with type 2 diabetes. Method: To develop Korean version DSCB-OA used translation and back-translation method. Then, Korean version DSCB-OA was analyzed using data of 278 older adults with type 2 diabetes. Cronbach's alpha coefficient, item to total correlation and test-retest reliability was used for the reliability test, and factor analysis was used for the construct validity. Results: Cronabach's alpha of the DSCB-OA was.77, and item to total correlation coefficient ranged from -.13 to.56. The results of factor analysis showed DSCB-OA consisted of four factors(diet, exercise, blood sugar test, treatment) which explained 62.8% of total variance. Conclusion: The Diabetes Self-Care Barriers Assessment Scaler for Older Adults (DSCB-OA) was confirmed helpful tool for Korean older adults with type 2 diabetes.

A dynamic reliability approach to seismic vulnerability analysis of earth dams

  • Hu, Hongqiang;Huang, Yu
    • Geomechanics and Engineering
    • /
    • v.18 no.6
    • /
    • pp.661-668
    • /
    • 2019
  • Seismic vulnerability assessment is a useful tool for rational safety analysis and planning of large and complex structural systems; it can deal with the effects of uncertainties on the performance of significant structural systems. In this study, an efficient dynamic reliability approach, probability density evolution methodology (PDEM), is proposed for seismic vulnerability analysis of earth dams. The PDEM provides the failure probability of different limit states for various levels of ground motion intensity as well as the mean value, standard deviation and probability density function of the performance metric of the earth dam. Combining the seismic reliability with three different performance levels related to the displacement of the earth dam, the seismic fragility curves are constructed without them being limited to a specific functional form. Furthermore, considering the seismic fragility analysis is a significant procedure in the seismic probabilistic risk assessment of structures, the seismic vulnerability results obtained by the dynamic reliability approach are combined with the results of probabilistic seismic hazard and seismic loss analysis to present and address the PDEM-based seismic probabilistic risk assessment framework by a simulated case study of an earth dam.

A Study on the Estimating Burst Pressure Distributions for Reliability Assessment of API 5L X65 Pipes (API 5L X65 배관의 신뢰도 평가를 위한 파열압력 분포 추정에 관한 연구)

  • Kim, Seong-Jun;Kim, Dohyun;Kim, Cheolman;Kim, Woosik
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.4
    • /
    • pp.597-608
    • /
    • 2020
  • Purpose: The purpose of this paper is to present a probability distribution of the burst pressure of API 5L X65 pipes for the reliability assessment of corroded gas pipelines. Methods: Corrosion is a major cause of weakening the residual strength of the pipe. The mean residual strength on the corrosion defect can be obtained using the burst pressure code. However, in order to obtain the pipe reliability, a probability distribution of the burst pressure should be provided. This study is concerned with estimating the burst pressure distribution using Monte Carlo simulation. A response surface method is employed to represent the distribution parameter as a model of the corrosion defect size. Results: The experimental results suggest that the normal or Weibull distribution should be suitable as the probability distribution of the burst pressure. In particular, it was shown that the probability distribution parameters can be well predicted by using the depth and length of the corrosion defect. Conclusion: Given a corrosion defect on the pipe, its corresponding burst pressure distribution can be provided at instant. Subsequently, a reliability assessment of the pipe is conducted as well.

An algorithm for evaluating time-related human reliability using instrumentation cues and procedure cues

  • Kim, Yochan;Kim, Jaewhan;Park, Jinkyun;Choi, Sun Yeong;Kim, Seunghwan;Jung, Wondea;Kim, Hee Eun;Shin, Seung Ki
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.368-375
    • /
    • 2021
  • The performance time of human operators has been recognized as a key aspect of human reliability in socio-complex systems, including nuclear industries. Because of the importance of the time factor, most existing human reliability assessment methods provide ways to quantify human error probabilities (HEPs) that are associated with the performance time. To quantify such kinds of HEPs, it is crucial to rationally predict the length of time required and time available and compare them. However, there have not been detailed guidelines that identify the critical cue presentation time or initial time of human performance, which is important to calculate the time information. In this paper, we introduce a time-related HEP calculation technique with a decision algorithm that determines the critical cue and its timing. The calculation process is presented with the application examples. It is expected that the proposed algorithm will reduce the variability in the time-related reliability assessment and strengthen the scientific evidence of the assessment process. The detailed description is provided in the technical report KAERI/TR-7607/2019.

A Study on the Development of the Core Emotional Assessment Questionnaire (CEAQ) Based on the Seven Emotions (七情) (한의학 칠정(七情)에 기반을 둔 핵심감정평가척도 개발 연구)

  • Lee, Go-Eun;Park, Bo-Young;Moon, Kwang-su;You, Jae-Min;Kang, Hyung-Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.26 no.2
    • /
    • pp.143-160
    • /
    • 2015
  • Objectives: The study purpose was to test the validity and reliability of the core emotional assessment questionnaire based on the seven emotions. Methods: Survey data were from 651 individuals and contained 141 items determined from a previous pilot study. Among the participants, 241 were retested. First, following analysis of the internal consistency reliability of the 141 items, we deleted items with Cronbach-$\alpha$ coefficient below 0.5. We then selected 100 final items after the first factor analysis. Second, the final 100 items were evaluated by internal consistency reliability, test-retest reliability, factor analysis, and correlational analysis. Results: Cronbach-$\alpha$ coefficient for the final 100 items were 0.866~0.956 and the test-retest reliability were above 0.70. The 100 items categorized into 7 factors explained 53.8% of the total variance. Analyzing the correlation of each chiljeong, we had a high positive correlation above 0.70 between sa and bi, bi and u, gong and kyeong. Conclusions: The final 100 items used for the core emotional assessment questionnaire based on the seven emotions showed satisfactory reliability and validity. Thus, it may be an appropriate instrument for measuring Chiljeong in the general population.

Testing the validity and reliability of an assessment tool for dental hygienists' consideration of patients with mild disabilities (치과위생사의 경증 장애인 환자 진료 고려사항에 대한 지식 측정 도구의 타당도와 신뢰도 검증)

  • Ye-Ji Kim;Hie-Jin Noh;So-Jung Mun;Sun-Young Han
    • Journal of Korean society of Dental Hygiene
    • /
    • v.23 no.1
    • /
    • pp.55-62
    • /
    • 2023
  • Objectives: The purpose of this study was to test the reliability and validity of an assessment tool for dental hygienists' consideration of patients with mild disabilities. Methods: Thirty-seven preliminary questions were compiled through literature review, and thirty-two questions were selected through content validity testing by eight experts. Two hundred and three dental hygienists completed the assessment tool as an online survey. The construct validity, internal consistency, and test-retest reliability of the tool were investigated using the SPSS 26.0 program. The construct validity was assessed using exploratory factor analysis. The internal consistency was assessed using Cronbach's alpha. The intraclass correlation coefficient (ICC) value with 95% confidence intervals was calculated for test-retest reliability. Results: Ten items and four factors were selected through exploratory factor analysis. The internal consistency reliability of the tool was found to be Cronbach's alpha=0.658, and test-retest reliability was found to be ICC=0.812. Conclusions: An assessment tool of care for patients with mild disabilities by dental hygienists is a reliable and valid tool suitable for the job characteristics of dental hygienists. It can be used in clinical practice and research.

Reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch for the assessment of physiological parameters during a simulated fatigue task

  • Anwer, Shahnawaz;Li, Heng;Umer, Waleed;Antwi-Afari, Maxwell Fordjour;Wong, Arnold YL
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.257-264
    • /
    • 2020
  • Objective: To investigate test-retest reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch tools in assessing physiological parameters during a simulated fatigue task. Methods: Ten university students (Mean age, 30.6 ± 1.7 years) participated in this pilot study. Participants were asked to perform a 30-minute of a simulated fatigue task in an experimental setup in a lab. The physiological parameters (e.g., heart rate, heart rate variability, respiratory rate, electrodermal activity, and skin temperature) were measured at baseline and immediately after the fatigue task. An intraclass correlation coefficient (ICC2,1) was used to evaluate the test-retest reliability of each tool in assessing physiological measures. In addition, the responsiveness of each tool to measure changes from baseline to posttest was calculated using a standardized response mean. Results: The Equivital Lifemonitor has shown good to excellent test-retest reliability for the assessment of heart rate (ICC, 0.97), heart rate variability (ICC, 0.86), respiratory rate (ICC, 0.77), and local skin temperature (ICC, 0.76). However, photoplethysmography based wristwatch showed moderate to good test-retest reliability for the assessment of heart rate (ICC, 0.71), heart rate variability (ICC, 0.73), electrodermal activity (ICC, 0.80), and skin temperature (ICC, 0.72). A large standardized response mean (>0.8) indicates that both tools can capture the changes in heart rate, heart rate variability, respiratory rate, skin temperature, and electrodermal activity after a 30-minute of fatigue task. Conclusions: The Equivital Lifemonitor and photoplethysmography based wristwatch devices are reliable in measuring physiological parameters after the fatigue task. Additionally, both devices can capture the fatigue response after a simulated construction task. Future field studies with a larger sample should investigate the sensitivity and validity of these tools in measuring physiological parameters for fatigue assessment at construction sites.

  • PDF

Variation of reliability-based seismic analysis of an electrical cabinet in different NPP location for Korean Peninsula

  • Nahar, Tahmina Tasnim;Rahman, Md Motiur;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.926-939
    • /
    • 2022
  • The area of this study will cover the location-wise seismic response variation of an electrical cabinet in nuclear power point (NPP) based on classical reliability analysis. The location-based seismic ground motion (GM) selection is carried out with the help of probabilistic seismic hazard analysis using PSHRisktool, where the variation of reliability analysis can be understood from the relation between the reliability index and intensity measure. Two different approaches such as the first-order second moment method (FOSM) and Monte Carlo Simulation (MCS) are helped to evaluate and compare the reliability assessment of the cabinet. The cabinet is modeled with material uncertainty utilizing Steel01 as the material model and the fiber section modeling approach is considered to characterize the section's nonlinear reaction behavior. To verify the modal frequency, this study compares the FEM result with recorded data using Least-Squares Complex Exponential (LSCE) method from the impact hammer test. In spite of a few investigations, the main novelty of this study is to introduce the reader to check and compare the seismic reliability assessment variation in different seismic locations and for different earthquake levels. Alongside, the betterment can be found by comparing the result between two considered reliability estimation methods.